• 제목/요약/키워드: Superheated Temperature

검색결과 66건 처리시간 0.024초

An Investigation of Downcomer Boiling Effects During Reflood Phase Using TRAC-M Code

  • Chon Woo Chong;Lee Jae Hoon;Lee Sang Jong
    • Journal of Mechanical Science and Technology
    • /
    • 제19권5호
    • /
    • pp.1182-1193
    • /
    • 2005
  • The capability of TRAC-M code to predict downcomer boiling effect during reflood phase in postulated PWR LOCA is evaluated using the results of downcomer effective water head and Cylindrical Core Test Facility (CCTF) experiments, which were performed at JAERI. With a full height downcomer simulator, effective water head experiment was carried out to investigate the applicability of the TRAC-M best estimate LOCA code to evaluate the effective water head with superheated wall temperature in downcomer. In order to clarify the effect of the initial superheat of the downcomer wall on the system and the core cooling behaviors during the reflood phase, two sets of analysis were also performed with a CCTF. Results show that TRAC­M code tends to under-predict downcomer effective water head and core differential pressure. However, the code results show a good agreement with the experimental results in downcomer temperature, heat flux and pressure. Finally, both experiment and calculation showed that the downcomer water head with the superheated downcomer wall is lower than that of the saturated wall temperature.

신경회로망을 이용한 증기표의 함수근사 (Function approximation of steam table using the neural networks)

  • 이태환;박진현
    • 한국정보통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.459-466
    • /
    • 2006
  • 열성능 평가를 위한 수치해석에서는 온도, 압력, 건도, 체적, 엔탈피, 엔트로피 등의 열역학적 성질들의 수치값이 필요하다. 그러나 이러한 성질들을 포함하고 있는 증기표를 그대로 사용할 수 없기 때문에, 효과적으로 모델링하여야 한다. 이러한 관점에서 함수근사 특성을 가진 신경회로망을 하나의 대안으로 검토하였다. 신경 회로망은 포화증기 영역과 과열증기 영역에 대해서 따로 구성하였다. 포화증기 영역에 대해서는 하나의 입력으로 7개의 출력을 얻을 수 있도록 하였으며, 각각 10개와 20개의 노드를 가진 은닉층을 구성 하였다. 과열증기 영역에 대해서는 2개의 입력으로 3개의 출력을 얻을 수 있도록 하였으며, 각각 15개와 25개의 노드를 가진 은닉층을 구성하였다. 제안된 모델은 온도, 엔탈피, 엔트로피의 백분율오차가 대부분 ${\pm}0.005%$, 압력이나 비체적의 백분율오차도 대부분 ${\pm}0.025%$ 범위 내로 수렴시킬 수 있었다. 이 성공적인 결과로부터 증기 표를 함수근사하는데 있어서 신경회로망이 아주 강력한 수단이 될 수 있음을 확인할 수 있었다.

과열증기 처리조건에 따른 닭 가슴살의 물리·화학적 및 관능 특성 (The Effect of Superheated Steam Cooking Condition on Physico-Chemical and Sensory Characteristics of Chicken Breast Fillets)

  • 오지혜;윤선;최윤
    • 한국식품조리과학회지
    • /
    • 제30권3호
    • /
    • pp.317-324
    • /
    • 2014
  • 본 연구는 여러 가지 과열증기 처리 조건이 닭 가슴살의 물리화학적 품질 특성과 관능에 미치는 영향을 분석하고, 이를 바탕으로 과열증기를 이용한 닭 가슴살의 최적의 조리 조건을 설정해 보고자 하였다. 일반적으로 많이 사용하는 전기 오븐 구이와 비교했을 때 과열증기 처리군 중 스팀 온도 $330^{\circ}C$에서 8분과 $350^{\circ}C$에서 6분 처리한 군에서 중량 손실률이 적고, 적절한 수분 함량을 나타냈으며, 질감에 있어 경도, 깨짐성은 낮고 탄력성이 높게 나타났고, 관능평가에서도 모든 항목에서 기호도가 높게 평가되었다. 따라서 닭 가슴살 조리에 과열증기 기술을 적용할 경우 일반적인 전기 오븐 구이와 비교했을 때 조리시간을 단축하고 품질과 기호도가 우수한 제품을 생산할 수 있을 것으로 사료된다.

대체 프레온 및 자연 냉매를 이용하는 이원 냉동시스템의 성능 예측 (Prediction on Performance of Cascade Refrigeration System using Alternative Freon and Natural Refrigerants)

  • 김종열;노건상
    • 한국산학기술학회논문지
    • /
    • 제13권4호
    • /
    • pp.1427-1433
    • /
    • 2012
  • 본 연구에서는 이원냉동시스템에서 사용되던 저온용 규제프레온냉매 R13 및 고온용 규제프레온냉매 R503의 대체냉매로서 프레온혼합냉매 및 친환경적 자연냉매를 사용하는 이원냉동시스템의 성능특성을 규명하고자 하였다. 이를 위해 일반적인 이원냉동시스템의 운전범위에서 과냉각도, 과열도, 응축온도, 증발온도, 캐스케이드 열교환기에서의 온도변화를 고려하였다. 고온시스템 및 저온시스템의 작동유체의 종류에 상관없이 이원냉동시스템의 COP는 캐스케이드의 온도영향을 받고 있으며, 또한 과냉각도가 증가할수록 COP는 높아지지만, 과열도의 영향은 크게 받지 않았다. 따라서 본 연구에서 고온용 시스템 및 저온용 시스템의 작동유체로 대체 프레온혼합냉매 및 자연냉매의 냉매조합 중에서 (R23/R290), (R23/R600), (R23/R600a), (R23/R717), (R744/R404A) 냉매를 사용하는 이원냉동시스템의 COP는 저온측에 R23, 고온측에 R22를 사용하는 시스템에 비해 20 ~ 36% 높게 나타났다.

수직관내(垂直管內)를 흘러내리는 액막식(液膜式) 흡수기(吸收器)의 흡수(吸收) 및 열전달특성(熱傳達特性)(제(第)2보(報) 열전달특성(熱傳達特性)) (Characteristics of Absorption and Heat Transfer for Film Falling along a Vertical Inner Tube (2nd. Report, Characteristics of Heat Transfer))

  • 엄기찬;이동호;최국광;카시와기 타카오;서정윤
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.257-264
    • /
    • 1993
  • This is the second report of a three part study on the absorption and heat transfer characteristics of absorber, the correlation of refrigerating capacity and heating capacity. The 2nd report deals with the heat transfer characteristics of a vertical falling film type absorber of inner copper tube. The solute is LiBr-Water solution(60wt%) and the solvent is water vapor. The film Reynoles numbers are varied in the range of 35~130. The states of LiBr solution at the top of absorber are supercooled liquid and superheated liquid. The results are summarized as follows ; Heat transfer results reveal that for the absorption of falling film, the state of LiBr solution appears to be influential in determining the heat transfer. Thus, for the state of supercooled liquid, heat transfer coefficient decreases with increasing the film Reynolds number, but in the condition of superheated liquid, it increases conversely. The mass transfer coefficients that were presented in the 1st.report and heat transfer coefficients of this paper are presented as the dimensionless correlation. The optimum water flowrate which brings about maximum value of heat flux in the film exists, and that increases with increasing the cooling water temperature.

  • PDF

100MW 발전소 개조 보일러의 증기온도 제어 (The Steam Temperature Control of Renovated Boiler in 100MW Power Plant)

  • 임건표;이흥호
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1935-1940
    • /
    • 2011
  • The control logic of steam temperature was redesigned, tested and applied to the power plant after its steam temperature equipments had been revised. This power plant use the ancillary gas gotten in the process of making iron in the steel mill. The boiler of power plant has the superheater and reheater to make the superheated steam. The superheater and reheater have the spray valve to control their temperature. The reheater has the gas bypass damper additionally in this plant. The control logics were redesigned in cascade forms and the initial parameters of control logics were calculated from the several step tests. The final parameters could be obtained through the several repeated tests and the feedforward functions were added by temperature deviation and air flow. The power plant is being commercially-operated normally by improved control logics and It is expected that this improved controls help the efficiency improvement and safe operation of plant.

Study on the Structure Optimization and the Operation Scheme Design of a Double-Tube Once-Through Steam Generator

  • Wei, Xinyu;Wu, Shifa;Wang, Pengfei;Zhao, Fuyu
    • Nuclear Engineering and Technology
    • /
    • 제48권4호
    • /
    • pp.1022-1035
    • /
    • 2016
  • A double-tube once-through steam generator (DOTSG) consisting of an outer straight tube and an inner helical tube is studied in this work. First, the structure of the DOTSG is optimized by considering two different objective functions. The tube length and the total pressure drop are considered as the first and second objective functions, respectively. Because the DOTSG is divided into the subcooled, boiling, and superheated sections according to the different secondary fluid states, the pitches in the three sections are defined as the optimization variables. A multi-objective optimization model is established and solved by particle swarm optimization. The optimization pitch is small in the subcooled region and superheated region, and large in the boiling region. Considering the availability of the optimum structure at power levels below 100% full power, we propose a new operating scheme that can fix the boundaries between the three heat-transfer sections. The operation scheme is proposed on the basis of data for full power, and the operation parameters are calculated at low power level. The primary inlet and outlet temperatures, as well as flow rate and secondary outlet temperature are changed according to the operation procedure.

발전용 보일러 전열 튜브 유로내 온도분포 불균일 개선기법 (The improvement method for power plant boiler temperature nonuniformity of heat transfer tube bank flow path)

  • 정훈;김범신;장석원;안연식;박건복;황정보
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.837-841
    • /
    • 2001
  • Almost all power plant boiler has temperature distribution nonuniformity problem in heat transfer tube flow path. It can cause hot spot damage of superheated or reheated heat transfer section and reduce maintenance schedule when nonuniformity is severe. There are two solutions for improvement temperature nonuniformity. one is change of gas flow distribution of gas path and the other is contorl steam flow in tube bank. Of course, first method is very difficulty to apply but second method is'nt. In this paper, control steam flow is used to solve temperature nonuniformity of power plant boiler.

  • PDF

Superheated Steam과 High Hydrostatic Pressure에 의한 갈비찜의 품질 개선 효과 (Quality Improvement of Galbijjim Using Superheated Steam and High Hydrostatic Pressure)

  • 서상희;김은미;김영붕;조은경;우현정;이민아
    • 한국식품영양과학회지
    • /
    • 제43권9호
    • /
    • pp.1423-1430
    • /
    • 2014
  • 본 연구는 갈비찜 제품의 품질을 개선하고자 SHS와 HPP 기술을 적용한 시료를 냉장온도(5, $10^{\circ}C$)에서 저장하면서 그 품질 변화를 살펴보았다. 기호도 조사를 통해 SHS 조리가 일반 조리에 비해 높은 기호도를 보였으며 특히 다즙성과 조직감(연한 정도)이 향상되는 것을 알 수 있었다. 이것은 조직감 측정 결과와 같은 경향으로 SHS 조리가 일반 조리에 비해 조직이 연해져 부드러운 조직감을 부여하는 것을 알 수 있었다. 또한 지방의 산화반응을 억제하며 총균수의 증가폭도 일반 조리구에 비해 적은 것을 확인할 수 있었으며 SHS-HHP 병행 처리 시 $5^{\circ}C$에서 15일간 저장하여도 검출한계 수준(<1 log CFU/g)으로 검출되었다. 또한 지방 산패도 값인 TBA 또한 SHS-HHP병행 처리군이 일반 조리에 비해 낮은 값을 보여 안전성을 확보할 수 있을 것으로 사료된다. 식육의 신선도를 나타내는 VBN은 간장 양념으로 인해 높은 값을 보였지만 육제품의 특성상 VBN 함량만으로 신선도 정도를 판단하기는 어려울 것으로 사료된다. 이상의 결과로 기존의 갈비찜 제품에 SHS 기술과 HPP 기술의 적용으로 제품의 품질 향상을 통한 기호도 상승과 유통기간 연장효과를 어느 정도 기대할 수 있는 것으로 생각되었다.

공냉식 응축기 관내 응축 열전달에 관한 연구 (A Study on the Condensation Heat Transfer inside Tube of an Air Cooled Condenser)

  • 정형호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권3호
    • /
    • pp.13-19
    • /
    • 2000
  • In the present study, a program for predicting thermal performance of an air cooled condenser is illustrated. Heat transfer equations of single phase and two phase flow are formulated into the form that is convenient to incorporate the local analysis method. The resulting equations are solved by temperature and mass correction methods. Empirical equations for both side fluids are incorporated in the caculation procedures. In order to compare the calculation results, superheat temperature of steam are varied. The tube length of superheated zone, wall temperature, temperature profile along the tube and steam qualities are predicted.

  • PDF