• Title/Summary/Keyword: Super P ratio

Search Result 59, Processing Time 0.027 seconds

A Case-Control Study on the Predictors of Neonatal Near-Miss: Implications for Public Health Policy and Practice

  • Johnson, Avita Rose;Sunny, Sobin;Nikitha, Ramola;Thimmaiah, Sulekha;Rao, Suman P.N.
    • Neonatal Medicine
    • /
    • v.28 no.3
    • /
    • pp.124-132
    • /
    • 2021
  • Purpose: Neonatal near miss (NNM) allows for the detection of risk factors associated with serious newborn complications and death, the prevention of which could reduce neonatal mortality. This study was conducted with the objective of identifying predictors for NNM in a tertiary hospital in Bangalore city. Methods: This was an unmatched case-control study involving 120 NNM cases and 120 controls. NNM was determined using Pileggi-Castro's pragmatic and management criteria. Data was collected from in-patient hospital records and interviews of postpartum mothers. Multiple logistic regression of exposure variables was performed to calculate adjusted odds ratio (AOR) with 95% confidence interval (CI). Results: Significant predictors were maternal age ≥30 years (AOR, 5.32; 95% CI, 1.12 to 9.29; P=0.041), inadequate antenatal care (ANC) (AOR, 8.35; 95% CI, 1.98 to 51.12; P=0.032), <3 ultrasound scans during pregnancy (AOR, 12.5; 95% CI, 1.60 to 97.27; P=0.016), maternal anaemia (AOR, 18.96; 95% CI, 3.10 to 116.02; P=0.001), and any one obstetric complication (hypertensive disorder in pregnancy, diabetes in pregnancy, preterm premature rupture of membranes, prolonged labour, obstructed labour, malpresentation) (AOR, 4.34; 95% CI, 1.26 to 14.95; P=0.02). Conclusion: The predictors of NNM identified has important implications for public health policy and practice whose modifications can improve NNM. These include expanding essential ANC package to include ultrasound scans, ensuring World Health Organization recommendations of eight ANC visits, capacity building at all levels of health care to strengthen routine ANC and obstetric care for effective screening, referral and management of obstetric complications.

Growth Properties of Carbon nanowall according to the Reaction Gas Ratio (반응가스 비율에 따른 탄소나노월의 성장특성)

  • Kim, Sung-Yun;Kang, Hyunil;Choi, Won Seok;Joung, Yeun-Ho;Lim, Yonnsik;Yoo, Youngsik;Hwang, Hyun Suk;Song, Woo-Chang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.351-355
    • /
    • 2014
  • Graphite electrodes are used for secondary batteries, fuel cells, and super capacitors. Research is underway to increased the reaction area of graphite electrodes used carbon nanotube (CNT) and porous carbon. CNT is limited to device utilization in order to used a metal catalyst by lack of surface area to improve. In contrast carbon nanowall (CNW) is chemically very stable. So this paper, microwave plasma enhanced chemical vapor deposition (PECVD) system was used to grow carbon nanowall (CNW) on Si substrate with methane ($CH_4$) and hydrogen ($H_2$) gases. To find the growth properties of CNW according to the reaction gas ratio, we have changed the methane to hydrogen gas ratios (4:1, 2:1, 1:2, and 1:4). The vertical and surficial conditions of the grown CNW according to the gas ratios were characterized by a field emission scanning electron microscopy (FE-SEM) and Raman spectroscopy measurements showed structure variations.

Development of a Computer Program for Thermal Sizing of a Copper Bonded Steam Generator (구리밀봉 증기발생기의 열적크기 계산을 위한 프로그램 개발)

  • 김의광;김연식;어재혁;김성오;백병준
    • Journal of Energy Engineering
    • /
    • v.12 no.2
    • /
    • pp.84-92
    • /
    • 2003
  • A one-dimensional thermal-hydraulic analysis computer program is developed for thermal sizing of a copper bonded steam generator. It is assumed that the conduction heat transfer of copper region between the hot side and the cold side tube is one-dimensional and its thermal resistance is derived as a function of a tube pitch. The flow regions of the water/steam side are divided into four regions: subcooled, saturated, film boiling, and super-heated. The number of tube selected ranges from 250 to 3500 and the pitch to tube diameter (P/D) ratios are 1.4, 1.6 and 1.8 for the parametric study calculation. The calculation results showed that when the number of tube was 2500, the length of the heating tube was about 12 m and the outside diameter of the steam generator was about 3 m. If the P/D ratio increases, the thermal resistance of copper component also increases, however the length of the heating tube is not so much increased.

Clinical Effectiveness of Acupuncture in the Treatment of Non-Alcoholic Fatty Liver Disease: A Systematic Review (비알코올성 지방간 질환에 대한 침치료의 효과 : 체계적 고찰)

  • Hyun, Joon;Lee, Joo-bok;Kim, So-yeon;Han, Chang-woo
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.6
    • /
    • pp.1206-1224
    • /
    • 2018
  • Purpose: This systematic review was planned and performed in order to determine the clinical effectiveness of acupuncture for non-alcoholic fatty liver disease (NAFLD). Methods: We searched related randomized controlled trials in several medical online databases, including China National Knowledge Infrastructure (CNKI), Excerpta Medica dataBASE (EMBASE), Public/Publisher MEDLINE (PubMed), Cochrane Central Register of Controlled Trials (CENTRAL), National Digital Science Library (NDSL), and Research Information Sharing Service (RISS). NAFLD related outcomes were extracted from the included trials and meta-analyzed. Results: From the 8 included trials, the values of the following examinations were extracted: liver ultrasonography, liver CT, body fat CT, aspartate transaminase (AST), alanine transaminase (ALT), gamma-glutamyltransferase (GGT), total cholesterol (TC), triglyceride (TG), low density lipoprotein (LDL) cholesterol, high density lipoprotein (HDL) cholesterol, fasting blood sugar (FBS), hosmeostatic model assessment for insulin resistance (HOMA-IR), weight, body mass index (BMI), waist hip ratio (WHR), obesity degree, body fat mass, body fat rate, leptin, malondialdehyde (MDA), and super oxide dismutase (SOD). In the 4 outcomes, cure rate in liver ultrasonography (RR=1.56; 95%CI=1.05~2.31; P=0.03), cure rate in liver CT (RR=2.23; 95%CI=1.33~3.72; P=0.002), TC (MD=-0.78; 95%CI=-1.41~-0.15; P=0.02), and TG (MD=-2.05; 95%CI=-3.88~-0.21; P=0.03), acupuncture was more effective than the control intervention. Conclusions: In this meta-analysis, acupuncture relieved hepatic steatosis, and reduced TC, and TG in NAFLD patients. more well-planned studies are still needed due to the heterogeneity and the considerable methodological flaws in the analyzed trials.

Synthesis of pH-Sensitive Hydrogel Nanoparticles in Supercritical Carbon Dioxide (초임계 이산화탄소를 이용한 pH 감응성 하이드로젤 입자의 합성)

  • Yang, Juseung;Ryu, Won;Lee, Sangmin;Kim, Kyusik;Choi, Moonjae;Lee, Youngmoo;Kim, Bumsang
    • Korean Chemical Engineering Research
    • /
    • v.47 no.4
    • /
    • pp.453-458
    • /
    • 2009
  • Recently, new methods to synthesize and process polymers without toxic organic solvents are needed in order to solve environmental problems. The use of supercritical carbon dioxide as a solvent for the polymer synthesis is attractive since it is non-toxic, non-flammable, naturally abundant, and the product may be easily separated from the solvent. In this study, we developed the method using super critical $CO_2$ to prepare P(MAA-co-EGMA) hydrogel nanoparticles as an intelligent drug delivery carrier. The effects of concentrations of PtBuMA-PEO as a dispersion stabilizer and AIBN as an initiator on the particle synthesis were investigated. When PtBuMA-PEO concentration increased, the particle size decreased. However, there was no significant difference in the particle size according to the AIBN concentration. There was a drastic change of the equilibrium weight swelling ratio of P(MAA-co-EGMA) hydrogel nanoparticles at a pH of around 5, which is the $pK_a$ of PMAA. At a pH below 5, the hydrogels were in a relatively collapsed state but at a pH higher than 5, the hydrogels swelled to a high degree. In release experiments using Rh-B as a model solute, the P(MAA-co-EGMA) hydrogel nanoparticles showed a pH-sensitive release behavior. At low pH(pH 4.0) a small amount of Rh-B was released while at high pH(pH 6.0) a relatively large amount of Rh-B was released from the hydrogels.

Development of OCB mode with impulsive driving scheme for improving moving picture quality

  • Kim, J.L.;Lee, C.H.;Park, S.Y.;Yoo, S.W.;Oh, J.H.;Lee, S.H.;Chai, C.C.;Park, C.W.;Ban, B.S.;Ahn, S.H.;Hong, M.P.;Chung, K.H.;Lim, S.K.;Kim, K.H.;Souk, J.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1049-1052
    • /
    • 2004
  • In general, contrary to the CRTs with impulsive emission, liquid crystal displays have motion artifacts such as blurring. ghost image, decrease of dynamic CR(contrast ratio), and stroboscopic motion due to hold type driving method. In this paper, to improve motion picture quality of LCDs. impulsive driving method of black data insertion was applied to the OCB mode which is well known for its fast LC response time and wide viewing angle properties. Subject evaluation was carried out with CRT, TN, SIPS(Super IPS). and impulsive driving OCB. Moving picture image quality near CRT was obtained in impulsive OCB driving mode

  • PDF

A Novel Iron(III) Selective Membrane Electrode Containing a Tripodal Polycatacholamine as Sensor

  • Bera, Rati Kanta;Sahoo, Suban K;Baral, Minati;Kanungo, B.K.
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.10
    • /
    • pp.3592-3596
    • /
    • 2011
  • A novel poly(vinylchloride)-based membrane sensor using $N^1$,$N^3$,$N^5$-tris(2-(2,3-dihydroxybenzylamino)-ethyl)cyclohexane-1,3,5-tricarboxamide (CYCOENCAT, L) as ionophore has been prepared and explored as $Fe^{3+}$ selective electrode. The membrane electrode composed of ionophore, poly(vinylchloride) and o-nitropheyloctyl ether in the optimum ratio 4:33:63 gave excellent potentiometric response characteristics, and displayed a linear log[$Fe^{3+}$] versus EMF response over a wide concentration range of $1.0{\times}10^{-5}-1.0{\times}10^{-1}$ M with super nernstian slope of 28.0 mV/decade and the detection limit of $8.0{\times}10^{-6}$ M. The proposed ion selective electrode showed fast response time (< 15 s), wide pH range (3.0-7.0), high non-aqueous tolerance (up to 20%) and adequate long life time (120 days). It also exhibited very good selectivity for $Fe^{3+}$ relative to a wide variety of alkali, alkaline earth, transition and heavy metal ions. Further, the analytical applicability of the sensor was tested as an indicator electrode in the potentiometric titration of $Fe^{3+}$ with EDTA.

Simple Synthesis of SiOx by High-Energy Ball Milling as a Promising Anode Material for Li-Ion Batteries

  • Sung Joo, Hong;Seunghoon, Nam
    • Corrosion Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.445-453
    • /
    • 2022
  • SiOx was prepared from a mixture of Si and SiO2 via high-energy ball milling as a negative electrode material for Li-ion batteries. The molar ratio of Si to SiO2 as precursors and the milling time were varied to identify the synthetic condition that could exhibit desirable anode performances. With an appropriate milling time, the material showed a unique microstructure in which amorphous Si nanoparticles were intimately embedded within the SiO2 matrix. The interface between the Si and SiO2 was composed of silicon suboxides with Si oxidation states from 0 to +4 as proven by X-ray photoelectron spectroscopy and electrochemical analysis. With the addition of a conductive carbon (Super P carbon black) as a coating material, the SiOx/C manifested superior specific capacity to a commercial SiOx/C composite without compromising its cycle-life performance. The simple mechanochemical method described in this study will shed light on cost-effective synthesis of high-capacity silicon oxides as promising anode materials.

Echocardiographic Parameters of Pulmonary Atresia with Intact Ventricular Septum(PA/IVS) (심실 중격 결손을 동반하지 않은 폐동맥 폐쇄 환아에서의 심초음파 계측치)

  • Lee, Young Seok;Kim, Yeo Hyang;Hyum, Myung Chul;Lee, Sang Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.5
    • /
    • pp.484-489
    • /
    • 2003
  • Purpose : To understand morphologic and hemodynamic variations in patients with pulmonary atresia with intact ventricular septum(PA/IVS), and to decide the best treatment modalities, we measured right ventricular volume, inflow, and outflow valvular annulus size in these patients and compared them with those of normal newborns. Methods : Eight patients with PA/IVS diagnosed by echocardiography from January to December 2001 were enrolled in this study. Among the total eight patients, five were male and three were female. The mean age of patients was 6.9 days(1-34 days), and the mean body weight was 3,343 gm (2,970-4,000 gm). Ten fullterm newborn infants with sepsis or hyperbilirubinemia without heart disease were enrolled as a control group. Echocardiographic and Doppler studies using Acuson Aspen (7Mh probe) were recorded on super-VHS videotape and later on, with review mode. We measured volumes of right and left ventricles, aortic, pulmonic, mitral and tricuspid valvular annulus sizes using an installed program, and then these parameters were compared with those of the control group. Results : Mean Z-value of tricuspid valvular annulus in PA/IVS was $-3.69{\pm}2.80$(-8.4--0.45), and tricuspid/mitral valvular annulus size ratio $0.68{\pm}0.15$(0.43--0.84). The more the tricuspid/mitral valvular annulus size ratio, the more Z-value of tricuspid valvular annulus(P=0.003, r=0.885). Those patients who underwent pulmonary valvuloplasty(balloon or surgical) had a tendency toward larger volume of the right ventricle, more Z-value of pulmonic and tricuspid valvular annulus, and more tricuspid/mitral valvular annulus size ratio than those patients who underwent a shunt operation. Conclusion : Compared to a measurement of the volume of the right ventricle, measurements of tricuspid/mitral valvular annulus size ratio and Z-value of tricuspid valvular annulus may be easier and better parameters to decide the treatment method and to predict prognosis in PA/IVS patients.

A Study on the Fabrication of p-type poly-Si Thin Film Transistor (TFT) Using Sequential Lateral Solidification(SLS) (SLS 공정을 이용한 p-type poly-Si TFT 제작에 관한 연구)

  • Lee, Yun-Jae;Park, Jeong-Ho;Kim, Dong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.6
    • /
    • pp.229-235
    • /
    • 2002
  • This paper presents the fabrication of polycrystalline thin film transistor(TFT) using sequential lateral solidification(SLS) of amorphous silicon. The fabricated SLS TFT showed high Performance suitable for active matrix liquid crystal display(AMLCD). The SLS process involves (1) a complete melting of selected area via irradiation through a patterned mask, and (2) a precisely controlled pulse translation of the sample with respect to the mask over a distance shorter than the super lateral growth(SLG) distance so that lateral growth extended over a number of iterative steps. The SLS experiment was performed with 550$\AA$ a-Si using 308nm XeCl laser having $2\mu\textrm{m}$ width. Irradiated laser energy density is 310mJ/$\textrm{cm}^2$ and pulse duration time was 25ns. The translation distance was 0.6$\mu$m/pulse, 0.8$\mu$m/pulse respectively. As a result, a directly solidified grain was obtained. Thin film transistors (TFTs) were fabricated on the poly-Si film made by SLS process. The characteristics of fabricated SLS p -type poly-Si TFT device with 2$\mu\textrm{m}$ channel width and 2$\mu\textrm{m}$ channel length showed the mobility of 115.5$\textrm{cm}^2$/V.s, the threshold voltage of -1.78V, subthreshold slope of 0.29V/dec, $I_{off}$ current of 7$\times$10$^{-l4}$A at $V_{DS}$ =-0.1V and $I_{on}$ / $I_{off}$ ratio of 2.4$\times$10$^{7}$ at $V_{DS}$ =-0.1V. As a result, SLS TFT showed superior characteristics to conventional poly-Si TFTs with identical geometry.y.y.y.