• 제목/요약/키워드: Super High-Resolution

Search Result 225, Processing Time 0.031 seconds

Exploring Image Processing and Image Restoration Techniques

  • Omarov, Batyrkhan Sultanovich;Altayeva, Aigerim Bakatkaliyevna;Cho, Young Im
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.3
    • /
    • pp.172-179
    • /
    • 2015
  • Because of the development of computers and high-technology applications, all devices that we use have become more intelligent. In recent years, security and surveillance systems have become more complicated as well. Before new technologies included video surveillance systems, security cameras were used only for recording events as they occurred, and a human had to analyze the recorded data. Nowadays, computers are used for video analytics, and video surveillance systems have become more autonomous and automated. The types of security cameras have also changed, and the market offers different kinds of cameras with integrated software. Even though there is a variety of hardware, their capabilities leave a lot to be desired. Therefore, this drawback is trying to compensate by dint of computer program solutions. Image processing is a very important part of video surveillance and security systems. Capturing an image exactly as it appears in the real world is difficult if not impossible. There is always noise to deal with. This is caused by the graininess of the emulsion, low resolution of the camera sensors, motion blur caused by movements and drag, focus problems, depth-of-field issues, or the imperfect nature of the camera lens. This paper reviews image processing, pattern recognition, and image digitization techniques, which will be useful in security services, to analyze bio-images, for image restoration, and for object classification.

Construction of Low Cost Tiled Display System with Super High Resolution (초고해상도 저가형 타일드 디스플레이 시스템 구축)

  • Kim, Gi-Beom;Kim, Dae-Hyun;Park, Seong-Won;Kim, Myoung-Jun
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.455-462
    • /
    • 2006
  • 본 논문에서는 저가의 보급형 프로젝터를 사용하고 Programmable GPU 기법중 Pixel Shader 기술을 이용하여 에지블렌딩을 수행하였으며, $7{\times}4$ 개의 프로젝터로 구성된 $6592{\times}2784$ 픽셀의 초고해상도를 가지는 $5.6m{\times}2.4m$ 의 대형 타일드 디스플레이를 구축해 보았다. 또한 타일드 디스플레이용 응용프로그램으로서 타일드 디스플레이 시스템을 마치 하나의 컴퓨터처럼 작동시킬 수 있는 타일드 디스플레이 관리 프로그램을 개발했으며, 이 프로그램은 컴퓨터와 프로젝터 제어, 응용프로그램 실행 및 종료를 담당한다. 그 외에도 일반 컴퓨터에서는 실행이 불가능한 초고해상도의 이미지 및 동영상까지도 볼 수 있는 이미지 뷰어와 동영상 플레이어를 개발하였다. 또한 100 만 폴리곤 이상의 3D 모델을 실시간으로 인터렉션 할 수 있는 3D 뷰어 등을 개발 하였다.

  • PDF

Host galaxy of tidal disruption object, Swift J1644+57

  • Yoon, Yongmin;Im, Myungshin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.70.1-70.1
    • /
    • 2013
  • We present long-term optical to NIR data of the tidal disruption object, Swift J1644+57. The data were obtained with CQUEAN, UKIRT WFCAM observations. We analyze the morphology of the host galaxy of this object and decompose the bulge component using high resolution HST WFC3 images. We conclude that the host galaxy is bulge dominant. We also estimate the multi-band fluxes of the host galaxy through the light curves based on the long-term observational data. We fit the SED models to the multi-band fluxes of the host galaxy and determine its stellar mass. Finally, we estimate the mass of the central super massive black hole which is thought to be the main role of the tidal disruption event. The estimated stellar mass and black hole mass are $10^{9.1}M_{\odot}$, $10^{6.8}M_{\odot}$ respectively. We compare our results to other results that have studied before.

  • PDF

A Comparative Study of the Rainfall Intensity Between Ground Rain Gauge and Weather Radar (지상우량계와 기상레이더 강우강도의 비교연구)

  • Ryu, Chan-Su;Kang, In-Sook;Lim, Jae-Hwan
    • Journal of Integrative Natural Science
    • /
    • v.4 no.3
    • /
    • pp.229-237
    • /
    • 2011
  • Today they use a weather radar with spatially high resolution in predicting rainfall intensity and utilizing the information for super short-range forecast in order to make predictions of such severe meteorological phenomena as heavy rainfall and snow. For a weather radar, they use the Z-R relation between the reflectivity factor(Z) and rainfall intensity(R) by rainfall particles in the atmosphere in order to estimate intensity. Most used among the various Z-R relation is $Z=200R^{1.6}$ applied to stratiform rain. It's also used to estimate basic rainfall intensity of a weather radar run by the weather center. This study set out to compare rainfall intensity between the reflectivity of a weather radar and the ground rainfall of ASOS(Automatic Surface Observation System) by analyzing many different cases of heavy rain, analyze the errors of different weather radars and identify their problems, and investigate their applicability to nowcasting in case of severe weather.

HEVC Intra prediction using SRCNN (SRCNN 을 이용한 HEVC 화면 내 예측 부호화)

  • Kim, Nam Uk;Kang, Jung Won;Lee, Yung Lyul
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2017.11a
    • /
    • pp.110-112
    • /
    • 2017
  • 본 논문에서는 최신의 비디오 코덱 표준인 HEVC(High Efficiency Video Coding)의 화면 내 예측 부호화의 성능 향상을 위하여 SRCNN(Super Resolution Convolutional Neural Networks)을 이용하는 방법을 제안한다. SRCNN 은 비교적 최신 기술인 CNN(Convolutional Neural Network)을 사용하여 이미지를 추가적인 데이터 없이 보간 하여 해상도를 증가시키는 기술이다. HEVC 에서는 화면 내 예측의 잔차신호를 부호화 하기 위해 많은 비트를 소모하는데, 본 논문에서는 이 잔차신호들의 해상도를 낮추어 부호화 되는 비트를 줄이며, 복호화기에서 SRCNN 을 이용하여 원래의 해상도로 복원을 수행하여 압축성능을 향상 시키는 방법에 대하여 제안한다. 제안하는 기술은 HM 16.6 에 구현하였으며, CNN 트레이닝에 Caffe 라이브러리를 사용하였다.

  • PDF

Measurement of Film Thickness by Fringe Intensity Analysis in Point Contact Elastohydrodynamic Lubrication (점접촉 탄성 유체 윤활에서의 띠 무의 강도에 의한 유막 두께 측정)

  • 장시열;최언진
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.103-113
    • /
    • 1999
  • Point contact film thickness in elastohydrodynamic lubrication (EHL) is analyzed by the image processing method for the monochromatic incident light. Interference between the reflected lights both on Cr coating of glass disk and on super finished ball makes circular fringes, which are regarded as film thickness together with numbering of fringe order. In this study, we developed technology to measure the film thickness by analyzing dark and bright intensity waves which results from monochrome green light. Two typical fringe patterns only with intensity values 3re examined for the measurement of point contact EHL film thickness. We expect that this technology will give valuable clue to improve color image processing analysis for high resolution of EHL film thickness with white incident light.

  • PDF

On the route towards Si-based full color LED microdisplays for NTE applications

  • Smirnov, A.;Labunov, V.;Lazarouk, S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.727-731
    • /
    • 2005
  • Design and manufacturing process of a full color LED microdislay fabricated by standard CMOS technology and containing an array of aluminum / nanostructured porous silicon reverse biased light emitting Schottky diodes will be discussed. Being of a solid state construction, this microdisplays are cost-effective, thin and light in weight due to very simple device architecture. Its benefits include also super high resolution, wide viewing angles, fast response time and wide operating temperature range. The advantages of full integration of an LED-array and driving circuitry onto a Si-chip will be also discussed.

  • PDF

Measurements of Evanescent Wave using a Mano-size Optical Probe (나노 사이즈 광프로브에 의한 에버네슨트파의 측정)

  • 최영규
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.1
    • /
    • pp.30-35
    • /
    • 2004
  • We have carried out a basic experiment in order to develope a super high-resolution optical microscope which transcend the limitation of diffraction and the wavelength of lightwave. The image of this scope is composed by measuring the evanescent wave which is localized on the surface of the testing materials. A detecting probe was fabricated with a single mode optical fiber to be sharpened by the chemical etching, and drived by PZT. The standing wave of $0.33\mu\textrm{m}$ wavelength evanescent wave which was generated from the $0.78\mu\textrm{m}$-wavelength semiconductor laser was detected by the $0.5\mu\textrm{m}$-thickness optical fiber probe.

Host galaxy of tidal disruption object, Swift J1644+57

  • Yoon, Yongmin;Im, Myungshin;Lee, Seong-Kook;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.48.2-48.2
    • /
    • 2014
  • We present long-term optical to NIR data of the tidal disruption object, Swift J1644+57. The data were obtained with CQUEAN, UKIRT WFCAM observations. We analyze the morphology of the host galaxy of this object and decompose the bulge component using high resolution HST WFC3 images. We conclude that the host galaxy is bulge dominant. We also estimate the multi-band fluxes of the host galaxy through the light curves based on the long-term observational data. We fit the SED models to the multi-band fluxes of the host galaxy and determine its stellar mass. Finally, we estimate the mass of the central super massive black hole which is responsible for the tidal disruption event. The estimated stellar mass and black hole mass are ${\sim}10^{9.1}M_{\odot}$, ${\sim}10^{6.8}M_{\odot}$, respectively. We compare our results to other previous estimates.

  • PDF

A study on the implementation of Imaging System for Magnetic Resonance Imaging (자기공명전단을 위한 영상화 시스템 구현에 관한 연구)

  • Jin, S.O.;Won, J.I.;Park, Y.H.;Huh, Y.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.597-599
    • /
    • 1998
  • The clinical acceptance of magnetic resonance imaging(MRI) system has been more rapid than that of the other medical image diagnosis system(X-ray, CT, etc) with the advantage of nonhazardous nature, high resolution capability, potential for chemically specified imaging. MRI system is composed of super conducting magnet, gradient fields, rf transceiver, system controller and imaging software technology. In this paper, introducing the principle of magnetic resonance imaging, it proposes the implementation of PC-based MRI system.

  • PDF