• Title/Summary/Keyword: Sun block

Search Result 644, Processing Time 0.023 seconds

The Effect of Developed SCB Liquid Fertilizer on the Growth of Kentucky Bluegrass (성분이 추가된 SCB저농도액비가 켄터키블루그래스의 생육에 미치는 효과)

  • Ham, Suon-Kyu;Kim, Young-Sun;Lim, Hye-Jung
    • Asian Journal of Turfgrass Science
    • /
    • v.25 no.1
    • /
    • pp.73-78
    • /
    • 2011
  • This study was conducted to evaluate the effect of developed SCB (DSCB) liquid fertilizer produced by adding N, P and K at SCB liquid fertilizer on the growth of kentucky bluegrass. Two different N sources used in DSCB were ammonium sulfate (DSCB-A) and urea (DSCB-U), respectively. Fertilizer treatments were designed as follows; non-fertilizer (NF), control (CF; chemical fertilizer), DSCB-A1 ($200\;ml{\cdot}m^{-2}$DSCB-A), OSCB-A2 ($250\;ml{\cdot}m^{-2}$DSCB-A), OSCB-U ($250\;ml{\cdot}m^{-2}$DSCB-U) and CF+SCB (CF+$250\;ml{\cdot}m^{-2}$SCB). Every treatment was arranged in a randomized complete block design with three replications. In kentucky bluegrass, turf color index, chlorophyll index, dry weight and nutrient contents were measured. Results were as follows; It was hardly affected by DSCB and SCB application in investigation of chemical properties of soil. Turf color index and chlorophyll index in DSCB and SCB treatments were increased by 1~2% and 19~24% than NF, respectively and similar to CF. As applied with DSCB and SCB, dry weight of DSCB-U and CF+SCB was increased by 36% and 10% than CF, respectively, but similar to that of OSCB-A1 and DSCB-A2. Evaluated with turf quality and growth, DSCB-U was the best in all treatment and OSCB-A1 the most efficient. These results indicated that applications of OSCB and SCB promoted turf quality and growth of kentucky bluegrass or similar to CF, so that they were expected to replace chemical fertilizers.

The Effects of Bastnasite Nitrate Fertilizer on the Growth of Creeping Bentgrass (질산희토비료가 크리핑벤트그래스의 생육에 미치는 영향)

  • Kim, Young-Sun;Ham, Suon-Kyu;Jeon, Seong-Jin
    • Asian Journal of Turfgrass Science
    • /
    • v.25 no.1
    • /
    • pp.89-93
    • /
    • 2011
  • This study was conducted to evaluate the effects of bastnasite nitrate fertilizer (BNF) on the growth of creeping bentgrass. Fertilizer treatments were designed as follows; non-fertilizer (NF), control (CF; compound fertilizer), RE-l (CF+0.3 $g{\cdot}m^{-2}$BNF), RE-2 (CF+0.5 $g{\cdot}m^{-2}$BNF), RE-3 (CF+1.0 $g{\cdot}m^{-2}$BNF) and RE-4 (0.5 $g{\cdot}m^{-2}$BNF). Every treatment was arranged in a randomized complete block design with three replications. In creeping bentgrass, turf qualities such as turf color index and chlorophyll index, shoot number, clipping dry weight and nutrients of tissue were measured. It was hardly affected by BNF application in investigation of chemical properties of the soil. By applying BNF, turf color index and chlorophyll index in RE-2 were increased 3.9% and 9.2% more than NF. As applied BNF on creeping bentgrass, shoot number was increased 9% in RE-4 more than NF and 22% in RE~2 more than CF. It was increased in N uptake and clipping dry weight of creeping bentgrass by supplying BNF. These results indicated that the BNF application promoted a turf qualities and a growth of creeping bentgrass by advancing N uptake and shoot number.

The Effect of Developed SCB Liquid Fertilizer on the Growth of Creeping Bentgrass (개량 SCB 저농도액비가 크리핑벤트그래스의 생육에 미치는 효과)

  • Ham, Suon-Kyu;Kim, Young-Sun
    • Asian Journal of Turfgrass Science
    • /
    • v.25 no.1
    • /
    • pp.100-105
    • /
    • 2011
  • This study was conducted to evaluate the effect of developed SCB(DSCB) produced by adding N, P and K to SCB liquid fertilizer on the growth of creeping bentgrass. Fertilizer treatments were designed as follows; non-fertilizer (NF), control (CF; chemical fertilizer), 100 DSCB (250 $ml{\cdot}m^{-2}$DSCB), 80DSCB (200 $ml{\cdot}m^{-2}$DSCB) and CF+SCB (CF+250 $ml{\cdot}m^{-2}$SCB). Every treatment was arranged in a randomized complete block design with three replications. In creeping bentgrass, turf color index, chlorophyll index, dry weight, shoot number and nutrient content were measured. The results were as follows; Chemical properties of soil was hardly affected by DSCB and SCB applications. Turf color index and chlorophyll index in DSCB and SCB treatment were increased by 2~3% and 14~19% than those in NF, respectively, and similar to those of CF treatment. As applied to DSCB and SCB, shoot number was increased by 7%, 21%, 36% in 100 DSCB, 80 DSCB and CF+SCB than NF, respectively, and by 19% in CF+SCB than in CF. Supplying DSCB and SCB increased dry weight of creeping bentgrass, compared to CF treatment. Compared with CF, nitrogen and P content in tissue was increased in CF+SCB and in 80DSCB, respectively. These results suggested that applications of DSCB and SCB promoted turf quality and growth of creeping bentgrass by enhancing N and P uptake and shoot number.

Production Yield Enhancement of Mycosporine-like amino acid(MAA)s in Transformed Microalgae Culture by Radiofrequency (형질전환 미세조류의 고주파 처리 배양을 통한 MAA 생산량 증가)

  • Seo, Hyo Hyun;Song, Mi Young;Kulkarni, Atul;Suh, Sung-Suk;Lee, Taek-Kyun;Moh, Sang Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3799-3804
    • /
    • 2014
  • In sea water, microalgae are exposed to a range of critical environmental conditions. Microalgae are protected from UV-A radiation due to the presence of mycosporine like amino acids(MAAs). Owing to the UV-A absorption properties of MAAs, they are used widely as a UV protecting ingredient in cosmetics. Therefore, there is a need to increase the production yield of MAAs. This study investigated the production yield of MAAs in transformed microalgae by radiofrequency(RF) exposure. Initially, the Glut-1 gene was transformed to Chlamydomonas hedleyi microalgae as a glucose transporter. The biomass was enhanced after Glut-1 gene transformation. In addition, the MAAs production yield was increased during large scale production in bioreactors due to the RF treatment. Therefore, purified extracts of MAAs can be used as a sun block material in the cosmetic industrial field.

A simulation study of speech perception enhancement for cochlear implant patients using companding in noisy environment (잡음 환경에서 압신을 이용한 인공 와우 환자의 언어 인지 향상 시뮬레이션 연구)

  • Lee Young-Woo;Ji Yoon-Sang;Lee Jong-Shil;Kim In-Young;Kim Sun-I.;Hong Sung-Hwa;Lee Sang-Min
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.5 s.311
    • /
    • pp.79-87
    • /
    • 2006
  • In this study, we evaluated the performance of a companding strategy as a preprocessing for speech enhancement and noise reduction. The proposed algorithm is based on two tone suppression that is human's hearing characteristics. This algorithm enhances spectral peak of speech signal and reduces background noise, however it has tradeoff characteristics between speech distortion and noise reduction due to limited channel number and nonlinear block. Therefore, we designed two different companding structures that have relative characteristics of noise reduction and speech distortion and found suitable companding structures by difference of individual speech perception ability in noise environment. Thus we proposed speech perception enhancement of cochlear implant user in noise environment with low SNR. The performance of the proposed algorithm was evaluated through 5 normal hearing listeners using noise band simulation. Improvement of speech perception was observed for all subjects and each subject preferred the different type of companding structure.

FINITE ELEMENT ANALYSIS OF CYLINDER TYPE IMPLANT PLACED INTO REGENERATED BONE WITH TYPE IV BONE QUALITY (IV형의 골질로 재생된 골내에 식립된 원통형 임플란트의 유한요소법적 연구)

  • Kim, Byung-Ock;Hong, Kug-Sun;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.331-338
    • /
    • 2004
  • Stress transfer to the surrounding tissues is one of the factors involved in the design of dental implants. Unfortunately, insufficient data are available for stress transfer within the regenerated bone surrounding dental implants. The purpose of this study was to investigate the concentration of stresses within the regenerated bone surrounding the implant using three-dimensional finite element stress analysis method. Stress magnitude and contours within the regenerated bone were calculated. The $3.75{\times}10-mm$ implant (3i, USA) was used for this study and was assumed to be 100% osseointegrated, and was placed in mandibular bone and restored with a cast gold crown. Using ANSYS software revision 6.0, a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The present study used a fine grid model incorporating elements between 165,148 and 253,604 and nodal points between 31,616 and 48,877. This study was simulated loads of 200N at the central fossa (A), at the outside point of the central fossa with resin filling into screw hole (B), and at the buccal cusp (C), in a vertical and $30^{\circ}$ lateral loading, respectively. The results were as follows; 1. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were increased from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, concentrated on the top of the cylindrical collar loading point B and C in vertical loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were increase from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in vertical loading. 2. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were decreased from loading point A to C in lateral loading. Stresses according to the depth of regenerated bone were concentrated on the top of the cylindrical collar in loading point A and B, distributed along the implant evenly in loading point C in lateral loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were decreased from loading point A to C in lateral loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in lateral loading. In summary, these data indicate that both bone quality surrounding the regenerated bone adjacent to implant fixture and load direction applied on the prosthesis could influence concentration of stress within the regenerated bone surrounding the cylindrical type implant fixture.

STUDY ON MUTATION OF RAS GENE IN DMBA INDUCED CARCINOMA OF HAMSTER BUCCAL POUCH (DMBA로 유도된 햄스터 협낭암종에서 ras 유전자 변이에 관한 연구)

  • Song, Sun-Chul;Kim, Kyung-Wook;Lee, Jae-Hoon;Kim, Chang-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.6
    • /
    • pp.581-590
    • /
    • 2000
  • Alterations in the cellular genome affecting the expression or function of genes controlling cell growth and differentiation are considered to be the main cause of cancer. Over 30 oncogenes can be activated by insertional mutagenesis, single point mutations, chromosomal translocations and gene amplification. The ras oncogenes have been detected in $15{\sim}20%$ of human tumors that include some of the most common forms of human neoplasia and are known to acquire their transforming properties by single point mutations in two domains of their coding sequences, most commonly in codons 12 and 61. The ras gene family consists of three functional genes, N-ras, K-ras and H-ras which encode highly similar proteins of 188 or 189 amino acid residues generically known as P21. ras proteins have been shown to bind GTP and GTP, and possess intrinsic GTPase activity. Experimental study was performed to observe the mutational change of the ras gene family and apply the results to the clinical activity. 36 Golden Syrian Hamster each weighing $60{\sim}80g$ were used and painted with 0.5% DMBA by 3 times weekly on the right buccal cheek(experimental side) for 6, 8, 10, 12, 14 and 16 weeks. Left buccal cheek (control side) was treated with mineral oil as the same manner of the right side. The hamsters were sacrificed on the 6, 8, 10, 12, 14 & 16 weeks. Normal and tumor tissues from paraffin block were completely dissected by microdissection and DNA from both tissue were isolated by proteinase K/phenol/chloroform extraction. Segments of the K-ras and H-ras gene were amplified by PCR using the oligonucleotide primers corresponding to the homologous region (codon 12 and 61) of the hamster gene, and then confirmational change of ras genes was observed by SSCP and autosequencing analysis. The results were as follows : 1. Malignant lesion could be found in the experimental side from the experimental six weeks. 2. One hamster among six showed point mutation of the H-ras codon 12($G{\rightarrow}A$ transition) at the experimental 10 and 14 weeks. 3. One of six at 6 weeks, two of six at 8 weeks and one of six at 12 weeks revealed the confirmational change of the H-ras codon 61($A{\rightarrow}T$ transversion). 4. The incidence of point mutation of H-ras codon 12 and 61 were 5.5%(2 of 36) and 11%(4 of 36) respectively. 5. Point mutation of the K-ras could not be seen during the whole experimental period. Form the above results, these findings strongly support the concept that H-ras oncogenes may have the influence of the DMBA induced carcinoma of hamster buccal pouch.

  • PDF

Design of Real-time Vital-Sign Encryption Module for Wearable Personal Healthcare Device (착용형 개인 건강관리 장치를 위한 실시간 생체신호 암호화 모듈의 설계)

  • Kim, Jungchae;Yoo, Sun Kook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.221-231
    • /
    • 2013
  • Exchanging personal health information(PHI) is an essential process of healthcare services using information and communication technology. But the process have the inherent risk of information disclosure, so the PHI should be protected to ensure the reliability of healthcare services. In this paper, we designed encryption module for wearable personal health devices(PHD). A main goal is to guarantee that the real-time encoded and transmitted PHI cannot be allowed to be read, revised and utilized without user's permission. To achieve this, encryption algorithms as DES and 3DES were implemented in modules operating in Telos Rev B(16bit RISC, 8Mhz). And the experiments were performed in order to evaluate the performance of encryption and decryption using vital-sign measured by PHD. As experimental results, an block encryption was measured the followings: DES required 1.802 ms and 3DES required 6.683 ms. Also, we verified the interoperability among heterogeneous devices by testing that the encrypted data in Telos could be decoded in other machines without errors. In conclusion, the encryption module is the method that a PHD user is given the powerful right to decide for authority of accessing his PHI, so it is expected to contribute the trusted healthcare service distribution.

Implementation of the automatic standby power blocking socket outlet having a blocking power threshold per electronic device by the smart machine (스마트 기기에 의해 전자기기별 차단전력문턱치 설정기능이 장착된 자동대기전력 차단콘센트 구현)

  • Oh, Chang-Sun;Park, Chan-Young;Kim, Dong-Hoi;Kim, Gi-Taek
    • Journal of Digital Contents Society
    • /
    • v.15 no.4
    • /
    • pp.481-489
    • /
    • 2014
  • In this paper, the automatic standby power blocking socket outlet to reduce standby power by blocking power threshold is implemented. Where, the standby power means a flowing power when a disused power electronic is plugged into the socket outlet. The proposed socket outlet can cut off the standby power by establishing a proper block power threshold electronic device according to each electronic device because it can monitor the amount of power through the smart machines such as the real-time PC or mobile phone and directly control the blocking power threshold. The software is implemented by using Visual Studio software, code vision and SN8 C studio, and the hardware is embodied in ATmega128, SN8F27E93S, USB to UART, and relay etc. Through the simulation, we find that the standby power of the proposed method is similar to that of the conventional method in case of the cellular phone but the standby power of the proposed method is much less than that of the conventional method in case of the computer, air conditioning, and set-top box. Therefore, it is proved that the proposed socket outlet has a superior performance in terms of the standby power.

EFFECT OF RHPDGF-BB AND RHBMP-2 ON OSSEOINTEGRATION OF TITANIUM IMPLANTS AT PERIIMPLANT BONE DEFECTS GRAFTED WITH HYDROXYAPATITE: MICRO-CT AND HISTOLOGIC ANALYSIS (Hydroxyapatite를 이식한 임플란트 주위 골결손부에서 rhPDGF-BB와 rhBMP-2가 골내 임플란트 osseointegration에 미치는 영향: Micro-CT 분석과 조직학적 평가)

  • Park, Jee-Hyun;Hwang, Sun-Jung;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.461-468
    • /
    • 2009
  • Purpose: Platelet derived growth factor(PDGF)-BB and bone morphogenetic protein(BMP)-2 are well-known representative growth factors. The purposes of this study were to investigate the effect of rhPDGFBB and rhBMP-2 on osseointegration of titanium implants at periimplant bone defects grafted with hydroxyapatite and to evaluate the feasibility of imaging bone structures around screw-type titanium implant with micro-CT. Materials and Methods: The first molar and all premolars in the mandible region of four beagle dogs were extracted. Following a healing period of 4 months, three $8{\times}8{\times}6mm$-sized bony defects were formed and screw-type titanium implants were placed with hydroxyapatite(HA) block and growth factors; Control group, PDGF group and BMP group. Two months post-implantation, the mandible was harvested. Bone volume(BV), bone-to-implant contact(BIC) and bone mineral density(BMD) were analyzed with micro-CT and histology. Results: According to micro-CT analysis, BV and BMD measures of PDGF and BMP group were significantly higher than control group(BV; PDGF group: $p{\fallingdotseq}0.011$, BMP group: $p{\fallingdotseq}0.006$/BMD; PDGF group: $p{\fallingdotseq}0.020$, BMP group: $p{\fallingdotseq}0.011$) and BIC measures of BMP group were significantly higher than PDGF group($p{\fallingdotseq}0.015$). In histologic evaluation, BIC measures of BMP group was significantly higher than PDGF group($p{\fallingdotseq}0.048$). The values of BV in histologic sections were higher than in micro-CT images and the values of BIC in micro-CT images were higher than in histologic sections. Conclusion: The findings of this experimental study indicates that the use of rhPDGF-BB and rhBMP-2 can increase new bone formation in a large bony defect around titanium implant, and rhBMP-2 is more effective than rhPDGF-BB. Micro-CT can be considered useful for assessment as a rapid and nondestructive method for 3-dimensional measurement of bone healing around implants. Further study is necessary, however, to remove metal artifacts around titanium implant and to standardize the method.