• Title/Summary/Keyword: Sun Pipe

Search Result 235, Processing Time 0.028 seconds

A Study on the Ultrasonic Effect for Turbulence Enhancement in the Flow Field of a Coaxial Circular Pipe (동심원관 유동장에서 난류증진을 위한 초음파 영향에 관한 연구)

  • Song, Min-Geun;Koo, Ja-Hoon;Lee, Sang-Bum;Son, Seung-Woo;Ju, Eun-Sun
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.742-747
    • /
    • 2001
  • A study on the ultrasonic effect for turbulence enhancement is carried out in the horizontal flow field of a coaxial circular pipe. A large transparent acryl tank is made to perform several experiments for the above research. The front flow field from jet exit is divided as 4 measuring regions to observe characteristics of the above flow field according to those with and without ultrasonic. An ultrasonic transducer with 2MHz high frequency is used to give them the ultrasonic forcing. Characteristics such as the velocity distribution, the kinetic energy and the turbulence intensity are visualized, observed, examined and considered at Re No. 2000. In results, it is clarified that the ultrasonic increases the turbulence enhancement. And the optimum and harmonious intensity suited to the power of flow is needed to maximize the turbulence enhancement.

  • PDF

Numerical Analysis for Unsteady Thermal Stratified Turbulent Flow in a Horizontal Circular Cylinder

  • Ahn, Jang-Sun;Ko, Yong-Sang;Park, Byeong-Ho;Youm, Hag-Ki;Park, Man-Heung
    • Nuclear Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.405-414
    • /
    • 1996
  • In this paper, the unsteady 2-dimensional turbulent flow model for thermal stratification in a pressurizer surge line of PWR plant is proposed to numerically investigate the heat transfer and flow characteristics. The turbulence model is adapted to the low Reynolds number K-$\varepsilon$ model (Davidson model). The dimensionless governing equations are solved by using the SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm. The results are compared with simulated experimental results of TEMR Test. The time-dependent temperature profiles in the fluid and pipe nil are shown with the thermal stratification occurring in the horizontal section of the pipe. The corresponding thermal stresses are also presented. The numerical result for thermal stratification by the outsurge during heatup operation of PWR shows that the maximum dimensionless temperature difference is about 0.83 between hot and cold sections of pipe well and the maximum thermal stress is calculated about 322MPa at the dimensionless time 28.5 under given conditions.

  • PDF

Desalinization Effect of Subsurface Drainage System with Rice Hull Packing (왕겨충전에 따른 암거의 제염 효과)

  • Lee, Seung-Heon;An, Yeoul;Yoo, Sun-Ho;Jung, Yeong-Sang
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.5
    • /
    • pp.63-69
    • /
    • 2001
  • The main purpose of this study is to seek desalinization effect of subsurface drainage system with rice hull packing in Dae-Ho Reclaimed Land. After 4 years installed sub-surface drainage system, distribution of drained water electric conductivity (ECw) was 4.43~12.78 ds/m. The soil profile showed partial development of the soil structure and compaction of subsoils with increased bulk density. The bulk density of the subsoil was 1.42~1.66 g/cm$^3$, which might limit root growth. The soil color changed near the drainage pipe line. Distribution of soil extract solution ECe and SAR as subsurface drainage pipe position and drainage canal distance showed desalinization effect of subsurface drainage system with rice hull packing as widening effective zone of subsurface drainage pipe.

  • PDF

Study on Laminar Heat Transfer Enhancement by Twisted-Inserts

  • Kwon, Young-Chel;Chang, Keun-Sun;Jeong, Ji-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.36-43
    • /
    • 2001
  • In order to understand the laminar heat transfer enhancement by swirl flow, the effects of heat transfer in a circular pipe with twisted inserts are investigated experimentally. In the present study, a uniform heat flux condition is considered. Laminar heat transfer correlations are developed using least square fit method from surface temperature distributions of an electrically-heated pipe and flow properties. Average Nusselt number correlations with twisted inserts are expressed as a function of swirl parameter, Reynolds number and prand시 number. When the twisted ratio is 6.50, mean Nusselt number and friction factor increase by approximately 500% and 300%, respectively, compared with the values for a pipe without inserts.

  • PDF

Guided-Waves-Based Mortar-Filled Steel Pipe Inspection Using EMAT End Wavelet Transform

  • Na Won-Bae;Kim Jeong-Tae;Ryu Yeon-Sun
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.2 s.69
    • /
    • pp.8-15
    • /
    • 2006
  • Guided-waves-based mortar-filled steel pipe inspection is carried out through using EMAT (Electro magnetic acoustic transducer) and wavelet transform. Possibly existing anomalies such as separation (or void) and inclusion are made in the fabricated mortar-fled steel pipes: these anomalies are infected. Since guided waves have the long range inspection capability, EMAT has its own advantages over the conventional PZT (Piezoelectric zirconate titanate), and wavelet transform gives the multi-resolution on time-frequency domain results, the suggested technique gives an alternative way for inspecting mortar-filled steel pipes, which are popularly used for supporting marine structures such as piers, wharfs, moles, and dolphins. Through this study, it is show that the suggested technique is promising for detecting the amounts of separations and inclusions.

Study on a Multi-pipe Water Hammer Phenomenon by using CFD of Rapid Valve Closing (전산유체해석(CFD)을 이용한 밸브의 급폐쇄에 따른 다중 배관 수격 현상에 관한 연구)

  • Park, No-Suk;Kim, Seong-Su;Kang, Moon-Sun;Choi, Jong-Woong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.479-487
    • /
    • 2013
  • This study was to investigate characteristics for the pressure wave propagation and the maximum pressure near a rapid closure valve which was installed the end of multi piping network. The multi piping network consists of one inlet and three outlet with straight pipes. The diameter of the pipes including the valve was 100 mm, 80 mm, 80 mm respectively. The valve was rapidly closed with the instantaneous time which was 0.023s in the level for the water hammer. For the simulation, the influence of the pipe thickness and deformation due to pressure-wave-propagation was not considered. CFD was conducted under the following condition : the initial pressure was 1bar in the inlet and the mass flow rate was 7.83 kg/s in the outlet(the velocity in the pipe with 100 mm diameter was 1 m/s). As the valve have conditions that were status with and without fluid flow in the pipe after valve closing, the maximum pressure change and the frequency analysis were examined. As the results, the case that was status with fluid flow appeared the higher maximum pressure than another's, the maximum frequency band was about 10 ~ 11 Hz.

Improvement of the CCFL Model of the RELAP5/MOD3.2.2B Code in a Horizontal Pipe

  • Heo, Sun;No, Hee-Cheon;Chang, Kyung-Sung;Ha, Sang-Jun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1999.05a
    • /
    • pp.115-115
    • /
    • 1999
  • To demonstrate the applicability of RELAP5 to the prediction of the onset offlooding in the hot leg at the reflux condensation phase during mid-loop operation, numerical analysis is performed for the counter-current flow in a horizontal pipe with the inclined riser using the RELAP5/MOD3.2.2b code. It is found that the RELAP5, simulating the CCFL phenomena using interfacial friction along with the flow regime map in the horizontal pipe, produces unsatisfactory results. Under the CCFL condition, it is observed that large oscillation exists in the flow rate, void fraction, and etc. and the liquid flow rate is much lower than that predicted by the CCFL model measured in the experiment. The CCFL model of RELAP5 for the vertical volume is extended to the model for the horizontal and inclined volumes. The horizontal volume flow regime map and interfacial friction model coupled to the CCFL model are modified. And a new correlation developed from Kang's experiment is implemented to the CCFL model of RELAP5. With this modified RELAP5, the analysis of CCFL phenomena in the horizontal pipe and hot leg geometry is performed, and produces reasonable results in comparison with experimental data.

  • PDF

Development of Dismantling Techniques for Irradiated HANARO Instrumented Capsule (03M-06U) in IMEF

  • Choo, Yong-Sun;Kim, Do-Sik;Oh, Wan-Ho;Baik, Seung-Je;Yoo, Byung-Ok;Park, Dae-Kyu;Baek, Sang-Ryul;Joo, Ki-Nam
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2005.05a
    • /
    • pp.501-502
    • /
    • 2005
  • During the cut and dismantling process of HANARO irradiated instrumented capsule(03M-06U), a little different phenomenon like a jamming was observed and occurred. So to release jamming between outer pipe and inner thermal media, the outer pipe will be cut piece by piece by capsule cutting machine installed in M2 hot cell until the outer pipe was eliminated or reduced as we could. It is assumed that this kind of problem was occurred following reasons: 1) This capsule has probably a problem during manufacturing process at shop before irradiation. 2) The gap between outer pipe and thermal media is not enough to meet design criteria for thermal expansion during irradiation at HANARO

  • PDF

Design Process of Fixing Pipe in Guide Pipe-Anchor System for Cable-Stayed Bridge (사장교 가이드 파이프 앵커 형식에서의 정착강관 설계절차)

  • Hong, Sung Nam;Park, Sun Kyu;Park, Byung Gun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.212-220
    • /
    • 2011
  • These days, many cable-stayed bridges were constructed in accordance with the trend in Korea. At the moment, construction technology of cable-stayed bridges has been remarkably developed but design technology still relies upon foreign technology very much. The cable anchor system that is one of key technologies of cable-stayed bridge brings powerful cable tension to produce local stress concentration and to disturb stress seriously, so for safety must be designed by a local detailed analysis is required. But without a clear design standard or design theory relying on F.E.M, and engineers don't understand theoretical basic mechanism of cable anchor system. As a result, engineers can be lose their judgement. Accordingly, this study examined theoretical design flow of fixing pipe in guide pipe-anchor system and additional considerations, in accordance with design standards at home and abroad to keep them in order and to suggest supplementary design flow.

The Failure Analysis of Double Pipe for Insulation Used Power Plant by Grooving Corrosion (발전소용 이중보온용 강관의 홈부식(Grooving Corrosion)에 의한 파손 분석)

  • Ham, Jong-Oh;Park, Ki-Duck;Park, Sung-Jin;Sun, Il-Sik
    • Journal of Applied Reliability
    • /
    • v.15 no.3
    • /
    • pp.197-206
    • /
    • 2015
  • Failure analysis of pre-insulated pipe (SPPS 380, 400A) transporting high temperature water ($95{\sim}110^{\circ}C$) for a plant was carried out. The damaged area (${\Phi}5mm$) of pre-insulated pipe was found only on welds. The chemical composition of damaged pipe meets specification of carbon steel pipes for pressure service (KS D 3562). As results of microstructure analysis, crack propagated from outer to inside after pitting corrosion occurred on the outside surface. The non-metallic inclusion existed on the end of crack. And the non-metallic inclusion continuously and linearly formed along with the bond line of welds. Based on SEM-EDS analysis, the nonmetallic inclusions have higher Manganese (Mn) and Oxygen (O) content but sulfur (S) was not detected. As results of water quality analysis, hydrogen ion concentration and minerals like Fe, Mg, Si were in low level. But the content of dissolved oxygen (11.2 ppm) was slightly higher than that of standard. It seems that the cause of damaged pipe is grooving corrosion due to MnO inclusion formed on bond line and corrosion took place nearby welds.