• 제목/요약/키워드: Summer Power

Search Result 400, Processing Time 0.021 seconds

A Study on the exhaust gas characteristics of the vehicle gasoline according to the ambient temperature (대기온도에 따른 휘발유 자동차의 배출가스 특성에 관한 연구)

  • Lim, Jae-Hyuk;Kim, Ki-Ho;Kim, Sung-Woo;Lee, Min-Ho;Oh, Sang-Gi
    • Journal of Power System Engineering
    • /
    • v.19 no.6
    • /
    • pp.47-53
    • /
    • 2015
  • Korea is the geographic location during the summer, the temperature rising to $35^{\circ}C$ and winter temperature is $-15^{\circ}C$ to reduce the air temperature changes, such as relatively large compared to other countries. This increase or decrease of the harmful exhaust gas discharged from automobile substantially inconvenience a significant impact on the active side of the car engine temperature and exhaust gas reducing device receives a large impact on the atmospheric temperature is regulation to be different. However, domestic vehicle emissions test temperature of $20{\sim}30^{\circ}C$ is it does not reflect this situation the actual test temperature to accurately measure the exhaust gas volume of the vehicle is difficult. In this study, domestic automobile exhaust gas test conditions of a test temperature $20{\sim}30^{\circ}C$ various temperatures, including (35, 25, 0, -7, -15, $-25^{\circ}C$) under the two vehicles (2.0L MPI, 2.4 L GDI) as was discussed with respect to the exhaust gas characteristics of the vehicle according to the ambient temperature gas. As a result, domestic emissions test temperature of $25^{\circ}C$ than average conditions were temperature decreases greenhouse gas emissions and increase overall increased by up to 15 times higher. Air temperature and the engine exhaust gas inconvenience a direct effect on the activation temperature required in the reduction unit is determined to be an increase of emissions and greenhouse gases, and also an increase in the variety of lubricants based lubricating and viscosity reduction, such as the engine oil due to the low temperature of these result It is considered that shows the.

Effects of Sand Supply and Artificial Floods on Periphyton in the Downstream of a Dam (Yangyang Dam, Korea) (모래 공급과 인공 홍수가 양양댐 하류하천의 부착조류에 미치는 영향)

  • Park, Misook;Lee, Jaeyong;Jung, Sungmin;Park, Chang-Keun;Chang, Kun;Kim, Bomchul
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.418-425
    • /
    • 2012
  • Dam construction in a river can change its hydrological pattern and trap sediments, which results in ecological changes in the downstream. It is a common phenomenon in the downstream of dams to have decreased sediment flow and increased periphyton. Artificial floods and sediment application are suggested as mitigation practices in order to simulate natural process of flood; transporting sediment and sloughing periphyton off. In this study the effects of artificial floods on periphyton were examined by applying sand artificially and discharging water from a dam (Yangyang Dam, Korea). The study area has been suffering from turbidity problems caused by shore erosion of the dam. The accumulation of inorganic sediments and increase of periphyton on the river bottom are the major factors of habitat deterioration in the downstream reaches. Artificial flood and artificial addition of sand was performed in summer and the effects were measured. Piles of applied sands were washed off easily by discharge and it enhanced the periphyton sloughing effect. The removal efficiency of periphyton was 50 ~ 80% within the 2 km reach from the dam. In conclusion artificial floods and sand application can be a good mitigation measure for the habitat rehabilitation after a dam construction in streams.

A Study on the Distribution of Summer Water Temperature in Wando Using Time-Series Analysis and Numerical Experiments (시계열 분석 및 수치실험을 통한 완도의 하계 수온분포)

  • Jang, Chan-Il;Jeong, Da-Woon;Kim, Dong-Sun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.2
    • /
    • pp.188-195
    • /
    • 2018
  • Time series analysis was conducted to identify the factors affecting short-term variation of water temperature in Wando. Spectrum analysis showed that air temperature peaks at diurnal period, while water temperature and tide level peak at both semi-diurnal and diurnal periods. Coherence between water temperature and the tide level presented 0.92 at semi-diurnal period. Numerical experiment were carried out to understand the spatio-temporal distribution of water temperature in the study area. Average water temperature difference between maximum ebb and flood was $0.3^{\circ}C$ in spring tide, but $0.13^{\circ}C$ in neap tide. The reason for the large difference in spring tide is that relatively cold water entered with strong tidal currents at flood tide and flowed out at ebb tide. Water temperature on coasts was higher than out at sea. This is because the depth in the coast is shallower than at sea, and water temperature increases rapidly due to solar radiation.

Study on Characteristics Comparison of Unpowered Cooling and Heating Combined Device using Solar Heat (태양열을 이용한 무동력 냉난방 겸용장치의 특성 비교 연구)

  • Lee, Jaehan;Chun, Taekyu;Yang, Youngjoon
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.20-26
    • /
    • 2018
  • As the global warming due to greenhouse effect has become serious problem, it is necessary to introduce the technology, for instance, such as diversity or saving of energy to reduce the use of fossil fuel. The purpose of this study was to investigate the characteristics on materials of absorption plate, unpowered and minimum use of power in cooling and heating combined device. As the results, it was observed that, in case of summer, since temperature of absorption device of solar heat(ADSH) was lower than that of no ADSH, cooling effect was insignificant in case of being not installed cold-reservoir. However, in case of winter, heating effect was certified even though the power was not used. At secondhand, the performance of ADSH with Cu was higher 2 times than that of ADSH with Al.

IoT-based Smart Switchboard Development for Power Supply of Entertainment Devices (엔터테인먼트 장치의 전원 공급을 위한 IoT 기반의 스마트 배전반 개발)

  • Kang, Yun-Jeong;Lee, Kwang-Jae;Choi, Dong-Oun
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.3
    • /
    • pp.311-321
    • /
    • 2021
  • In this study, a smart switchboard for power supply of entertainment devices was developed for the following purposes. First, the heat generated when the high-temperature and humid air inside is cooled by the thermoelectric module is smoothly discharged to the outside of the switchboard, thereby maximizing the cooling effect. So, it is possible to prevent excessive temperature rise inside the switchboard. Various problems such as condensation inside the switchboard can be prevented by controlling the temperature of the switchboard in which a fire occurs due to excessive heat in summer, removing moisture due to the cooling effect, and generating heat instead of cooling in winter. Second, it is a smart switchboard control system that can reduce the salt that may permeate inside the switchboard. Third, the smart switchboard system is an IoT-controlled switchboard that collects environmental data using a variety of sensors and can remotely control devices through a smartphone, and can be easily used in various fields.

A Statistical Assessment of Increasing Tidal Mixing Effects on Water Quality in the Shiwha Coastal Reservoir (시화호 해수유통량 증대에 따른 통계학적 수질 영향 분석)

  • Lee, Bum-Yeon;Lee, Chang-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.6
    • /
    • pp.425-432
    • /
    • 2021
  • A tidal power plant (TPP) has been in operation since the end of 2011 to improve the water quality of Shihwa Coastal Reservoir (SCR). Tidal mixing rate increased 5.6 times after the TPP operation so that in this study, its effects on water quality was assessed through statistical analysis of long-term water quality monitoring data. It was found that the increased tidal mixing contributed to solving the hypoxia problem in the bottom water by preventing the summer stratification. The analysis also showed that the increased tidal mixing had different effects depending on the relative concentration difference for each water quality substances between the SCR and the outside of SCR. The average concentrations of some substances (chemical oxygen demand, total phosphorus, chlorophyll-a) with higher concentrations than the outside of SCR decreased due to the dilution effect, but the other substances (total nitrogen, dissolved inorganic nitrogen, dissolved inorganic phosphorus) with lower concentrations compared to the outside ones increased on the contrary. Factor analysis also showed a consistent result that the first factor accounting for the water quality was changed from the organic-related substances to the nutrient-related substances after the increased tidal mixing. These results imply that the focus of future water quality management needs shifting from the organic substances to the nutrients, particularly dissolved inorganic nutrients. Considering the effect of inflow seawater on the nutrients, the management area should be extended to cover not only SCR but also a certain area outside of SCR.

Performance Evaluation of Ground Source Heat Pump System Utilizing Energy Pile in Apartment (공동주택에서 에너지 파일을 이용한 지열히트펌프 시스템의 성능 분석)

  • Lee, Jin-Uk;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.41-46
    • /
    • 2012
  • In Korea, Apartment houses recently occupy over 80% of all buildings. Ground source system has to be designed to consider feature of apartment house. Most apartment houses use PHC pile to get a bearing power of the soil. Therefore, the purpose of this study is to evaluate performance of ground source heat pump system utilizing energy pile under apartment. Object of experiment is low-energy experiment apartment in Song-do and Energy Pile are applied to 80%, 100% energy reduction model for heat-source. First, performance evaluation of Energy Pile geothermal system was done during summer season. As a result, The COP(coefficient of performance) about geothermal heatpump was approximately 5-6 while cooling. In winter season, Long experiment was performed because it was very important to evaluate ground condition for long time. During heating experiment, Indoor room set temperature was $20^{\circ}C$ and kept constant by heating. Coefficient of performance for heat pump and overall system was calculated. It was 3.5-4.5 for COP and 2.5-3.7 for system COP.

Comparison study of heatable window film using ITO and ATO

  • Park, Eun Mi;Lee, Dong Hoon;Suh, Moon Suhk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.300.2-300.2
    • /
    • 2016
  • Increasing of the demand for energy savings for buildings, thermal barrier films have more attracted. In particular, as heat loss through the windows have been pointed out to major problems in the construction and automobile industries, the research is consistently conducted for improving the thermal blocking performance for windows. The main theory of the technology is reflect the infrared rays to help the cut off the inflow of the solar energy in summer and outflow of the heat from indoors in winter to save the energy on cooling and heating. Furthermore, this is well known for prevent glare, reduces fading caused by harmful ultraviolet radiation and easy to apply on constructed buildings if it made as a film. In addition to these advantages, apply the transparent electrode to eliminate condensation by heating. Generally ITO is used as a transparent electrode, but is has a low stability in environmental factors. In this study, ITO and its alternative, ATO, is deposited by sputtering system and then the characteristic is evaluated each material based thermal barrier thin film. The optical property was measured on wide range of wavelength (200 nm 2500 nm) to know the transparency in visible wavelength and reflectivity in IR wavelength range. The electrical property was judged by sheet resistivity. Finally the changes of the temperature and current of the deposited film was observed while applying a DC power.

  • PDF

Straw to Grain Ratio Equation for Combine Simulation

  • Kim, Sang Hun;Gregory, James M.
    • Journal of Biosystems Engineering
    • /
    • v.40 no.4
    • /
    • pp.314-319
    • /
    • 2015
  • Purpose: The ratio of straw to grain mass as a function of cutting height affects combine efficiency and power consumption and is an important input parameter to combine simulation models. An equation was developed to predict straw to grain ratios for wheat as a function of cutting height. Methods: Two mass functions, one for straw and one for grain, were developed using regression techniques and measured data collected in west Texas during the summer, and used to predict the straw to grain ratio. Results: Three equations were developed to facilitate the simulation of a combine during wheat harvest. Two mass functions, one for straw and one for grain, were also developed; a quadratic equation describes the straw mass with an $R^2$ of 0.992. An S-shaped curve describes the mass function for grain with an $R^2$ of 0.957. An equation for straw to grain ratio of wheat was developed as a function of cutting height. The straw to grain ratio has an $R^2$ value of 0.947. Conclusions: In all cases, the equations had $R^2$ values above 0.94 and were significant at the 99.9 percent probability level (alpha = 0.001). Although all three equations are useful, the grain mass and straw to grain ratio equations will have direct application in combine simulation models.

A Study on the Estimation of CO2 Caused by Reinforcement of Efficiency Standard for Residental Air Conditioners (가정용 에어컨 효율기준 강화에 따른 CO2 산정연구)

  • Baek, Jung-Myoung;Lee, Byung-Ha;Won, Jong-Ryul;Kim, Jung-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.100-108
    • /
    • 2009
  • Due to rapid economic growth, the usage of residential cooling electrical appliances such as air conditioners and refrigerators has increased dramatically for the last decades. In other to reduce its energy consumption, the authorities have applied energy efficiency standards for principal appliances, including air conditioners. and then it can anticipate environmental effects. In this paper, it presents the actual procedure to analyze the effects for the decline in the $CO_2$ emissions and its methodology for the efficiency improvement of the air conditioner that takes a great portion of the summer power uses.