• Title/Summary/Keyword: Sulfur Hexafluoride

Search Result 55, Processing Time 0.025 seconds

Theoretical Studies of the Electrical Discharge Characteristics of Sulfur Hexafluoride

  • Radmilovic-Radjenovic, Marija;Radjenovic, Branislav
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.288-294
    • /
    • 2017
  • This paper contains results of the theoretical studies of the electrical breakdown properties in sulfur hexafluoride. Since the strong interaction of high-energy electrons with the polyatomic sulfur hexafluoride molecule causes their rapid deceleration to the lower energy of electron capture and dissociative attachment, the breakdown is only possible at relatively high field strengths. From the breakdown voltage curves, the effective yields that characterize secondary electron productions have been estimated. Values of the effective yields are found to be more consistent if they are derived from the experimentally determined values of the ionization coefficient and the breakdown voltages. In addition, simulations were performed using an one-dimensional Particle-in-cell/Monte Carlo collision code. The obtained simulation results agree well with the available experimental data with an error margin of less than 10% over a wide range of pressures and the gap sizes. The differences between measurements and calculations can be attributed to the differences between simulation and experimental conditions. Simulation results are also compared with the theoretical predictions obtained by using expression that describes linear dependence of the breakdown voltage in sulfur hexafluoride on the pressure and the gap size product.

Atmospheric Sulfur Hexafluoride $(SF_6)$ near the Kwanak Mountain, Seoul (서울 관악산 대기 중의 $SF_6$에 관한 연구)

  • Lee, Junghyun;Kim, Kyung-Ryul
    • Atmosphere
    • /
    • v.18 no.3
    • /
    • pp.225-235
    • /
    • 2008
  • Sulfur hexafluoride ($SF_6$), man-made compound, has been paid attention as a potent greenhouse gas. After Kyoto Pototcol on Climate Change in 1997, nations established the policy aimed at minimizing release of $SF_6$ to atmosphere. We have developed and operated an automatic analytical system for monitoring atmospheric $SF_6$ using gas chromatography with electron capture detector (GC-ECD) and packed separate-column. Here, we report and discuss 4-month record of atmospheric $SF_6$ concentrations monitored at Seoul National University (SNU) pilot station near the Kwanak Mountain, Seoul. Most of observed $SF_6$ concentrations were excessively high compared with Northern Hemisphere (NH) background trend obtained from National Oceanic and Atmospheric Administration (NOAA) Earth System Research Laboratory (ESRL) monitoring stations. And the observed $SF_6$ showed extremely wide variability ranging from 4.6 pptv to $1.1{\times}10^3$ pptv, which may be affected by local sources placed nearby. Simultaneous wind data with $SF_6$ measurements show that relatively high values of $SF_6$ correspond to weak wind as well as southerly. There are many engineering installations to the south of the station. The regional value of the atmospheric $SF_6$ estimated from the data selection by wind conditions is about 6.8 pptv. This value, which is similar to concentrations of urban areas, is higher than NH background concentration.

Experimental Study on the Interference of Water Vapor on the Chemical Ionization of OH by Sulfur Hexafluoride Ion

  • Park, Jong-Ho
    • Mass Spectrometry Letters
    • /
    • v.5 no.4
    • /
    • pp.120-123
    • /
    • 2014
  • The interference of water vapor on the chemical ionization (CI) of hydroxyl radicals (OH) by sulfur hexafluoride ion ($SF_6{^-}$) was investigated using a flow tube system coupled to a high-pressure CI mass spectrometer. Water vapor, which is required to study heterogeneous reactions of OH under real tropospheric conditions, transforms the reagent ion $SF_6{^-}$ into $SF_4O^-$ and $F^-(HF)_n$, resulting in a substantial loss in CI sensitivity. Therefore, under humid conditions, peaks corresponding to OH are drastically diminished, while those corresponding to OH-water complex ions ($[OH(H_2O)_n]^-$) are enhanced. $[OH(H_2O)_3]^-$ was observed as the major OH species. The obsercation of $[OH(H_2O)_n]^-$ by isolating humid conditions to the CI region and preliminary ab initio calculations suggested that $[OH(H_2O)_n]^-$ ions were produced from reactions between OH ions ($OH^-$) and water molecules. An additional helium buffer flow introduced into the CI region reduced loss of the reagent ion and resulted in a partial recovery of OH peak intensities under humid conditions.

A Study on Destruction Potential of Sulfur Hexafluoride (SF6) Using High Ionization Energy (고이온화에너지를 이용한 육불화황 (SF6) 분해가능성 연구)

  • Ryu, Jae-Yong;Kim, Jong-Bum;Choi, Chang-Yong;Lee, Sang-Joon;Kwak, Hee-Sung;Yun, Young-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.4
    • /
    • pp.446-453
    • /
    • 2012
  • Destruction and removal efficiency (DRE) of $SF_6$ was tested with varying degrees of ionization and initial concentrations of $SF_6$. The applied dose of ionization energy varied from 0 to 400 kGy. The initial concentration of $SF_6$ gas also varied from 1,000 ppm to 2,500 ppm. In order to assess the effect of a residence time on DRE (Destruction and Removal Efficiency, %), experiments were also conducted at different irradiation times of 3, 5, 10, 15, and 20 sec, respectively. The DRE of $SF_6$ increased with an increasing amount of dose and current. Regardless of initial concentration of $SF_6$, 90% level of DRE was achieved by applying over 10 mA of electrical current.

A Study on Increase of Sulfur Hexafluoride(SF6) Destruction and Removal Efficiency by Conditioning Agent(H2) (수소첨가에 의한 육불화황(SF6) 분해효율 향상 기초연구)

  • Ryu, Jae-Yong;Kim, Jong-Bum;Choi, Chang-Yong;Jang, Seong-Ho;Lee, Sang-Joon
    • Journal of Environmental Science International
    • /
    • v.21 no.9
    • /
    • pp.1163-1169
    • /
    • 2012
  • Destruction and removal efficiency (DRE) of $SF_6$ was tested with low degrees of ionization. The applied dose of ionization energy varied from 63.70 to 212.34 kGy. The initial concentration and flow rate of $SF_6$ gas were 1,000 ppm and 50L/min, respectively. In order to increase the DRE, injection of conditioning agent ($H_2$) were conducted. The DRE of $SF_6$ increased about 2 times with injection of $H_2$ gas.

Improved sulfur hexafluoride(SF6) gas analysis method for quality management of cryogenic refinement system (극저온 정제시스템의 품질관리를 위한 SF6 가스 분석방법 개선)

  • Lee, Jeong Eun;Cho, Min-ho;Lee, Won Seok
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.37-41
    • /
    • 2022
  • Because sulfur hexafluoride(SF6) is classified as one of the six major greenhouse gases, SF6 handling in power plant such as recovery, purification, and reuse is considered to be important. KEPCO has focused to develop the advanced recovery and purification technology of SF6 reuse. SF6 analysis includes the on-site analyses and on-line analyzer; i.e., (1) on-site analysis has an error rate of ±0.5% and (2) on-line analysis has an error rate of ±0.1%, which is possible to adjust operating conditions and to make the work more conveniently by analyzing SF6 concentration before and after purification step. This paper presents an online analysis method in the SF6 purification and reuse system. In addition, the analysis results and quality guarantees for each section of the analysis system were presented.

Study on the Separation of N2/SF6 Mixture Gas Using Polyimide Hollow Fiber Membrane (폴리이미드 중공사 막을 이용한 N2/SF6 혼합기체 분리에 관한 연구)

  • Kim, Dae-Hoon;Kim, Guang-Lim;Jo, Hang-Dae;Park, Jong-Soo;Lee, Hyung-Keun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.660-667
    • /
    • 2010
  • In this research polyimide, Matrimid 5218, hollow fiber membrane was used to recover sulfur hexafluoride($SF_6$) which is one of the six greenhouse gases from $N_2/SF_6$ mixture gas. Fibers were spun from using dry-wet phase inversion method. The module was manufactured by fabricating fibers after surface coating with silicone elastomer. The scanning electron microscopy(SEM) studies showed that the produced fibers typically had an asymmetric structure; a dense top layer supported by a sponge-like substructure. The developed module had a permeance of 0.78-1.36 GPU for $N_2$ with $N_2/SF_6$ selectivity of 2.44-5.08 at various pressure and temperature. For recovery of $SF_6$, a membrane module and 10 vol.% $SF_6$ from $N_2/SF_6$ mixture gas was used. The effects of various operating condition such as pressure, temperature, and retentate side flow rate were tested. When pressure and temperature were increased and retentate flow rate was decreased, the $SF_6$ purity in recovered gas was increased up to 37.5 vol.% with decreasing recovery ratio. When retentate flow rate was increased pressure and temperature was decreased, the $SF_6$ recovery ratio in retentate side was increased up to 89% with decreasing the $SF_6$ purity in retentate side.

On the Short Term Air Pollution Dispersion Model for the Single Souce -Diffusion Experiment With Tracer Gas- (單一 排出源大氣汚染 短期모델에 관한 硏究 -Tracer Gas에 의한 擴散實驗-)

  • 李鍾範;姜寅求
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.84-96
    • /
    • 1989
  • To evaluate the short term air pollution dispersion model, the diffusion experiment was conducted on the flat terrain near Chuncheon. Sulfur hexafluoride $(SF_6)$ gas was used to determine the horizontal spread of plume $(\sigmay)$ for calculated by CRSTER model. Results show that CRSTER model underestimates $\sigma$y because averaging time adjustment is not applied to calculate the $\sigma$y. The scheme that can estimate the atmospheric stability more accurate than Turner method, was presented.

  • PDF