• Title/Summary/Keyword: Suction pressure

Search Result 686, Processing Time 0.021 seconds

Characteristics of Noise Emission from Wind Turbine According to Methods of Power Regulation (파워 조절 방법에 따른 풍력 터빈의 방사 소음 특성)

  • Cheong, Cheol-Ung;Cheung, Wan-Sup;Shin, Su-Hyun;Chun, Se-Jong;Choi, Yong-Moon;Jung, Sung-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.8 s.113
    • /
    • pp.864-871
    • /
    • 2006
  • In the development of electricity generating wind turbines for wind farm application, only two types have survived as the methods of power regulation; stall regulation and full span pitch control. The main purpose of this paper is to experimentally identify the characteristics of noise emission of wind turbines according to the power regulation types. The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from each of 1.5 MW and 660 kW wind turbines (WT) utilizing the stall regulation and the pitch control for the power regulation, respectively. Apparent sound power level, wind speed dependence, third-octave band levels and tonality are evaluated for both of WTs. It is observed that equivalent continuous sound pressure levels (ECSPL) of the stall control type of WT continue to increase with increasing wind speed whereas those of the pitch control type of WT show less correlation with wind speed. These observed characteristics are believed to be due to the different airflow patterns around the blade between the stall regulation and the pitch control types of WT; the airflow on the suction side of blade in the stall types of WT are separated at the high wind speed. It is also found that the 1.5 MW WT using the stall control emits lower sound power than 660 kW one using the pitch control at wind speeds below 8m/s, whereas sound power of the former becomes higher than that of the latter in the wind speed over 8m/s. This wind-speed dependence of sound power leads to the very different noise omission characteristics of WTs depending on the seasons because the average wind speed in summer is lower than 8m/s whereas that in summer is higher. Based on these experimental observations, it is proposed that, in view of environmental noise regulation, the developer of wind farm should give enough considerations to the choice of power regulation of their WTG based on the weather conditions of potential wind farm locations.

A Numerical Study of the Performance Assessment of Coupled Thermo-Hydro-Mechanical (THM) Processes in Improved Korean Reference Disposal System (KRS+) for High-Level Radioactive Waste (수치해석을 활용한 향상된 한국형 기준 고준위방사성폐기물 처분시스템의 열-수리-역학적 복합거동 성능평가)

  • Kim, Kwang-Il;Lee, Changsoo;Kim, Jin-Seop
    • Tunnel and Underground Space
    • /
    • v.31 no.4
    • /
    • pp.221-242
    • /
    • 2021
  • A numerical study of the performance assesment of coupled thermo-hydro-mechanical (THM) processes in improved Korean reference disposal system (KRS+) for high-level radioactive waste is conducted using TOUGH2-MP/FLAC3D simulator. Decay heat from high-level radioactive waste increases the temperature of the repository, and it decreases as decay heat is reduced. The maximum temperature of the repository is below a maximum temperature criterion of 100℃. Saturation of bentonite buffer adjacent to the canister is initially reduced due to pore water evaporation induced by temperature increase. Bentonite buffer is saturated 250 years after the disposal of high-level radioactive waste by inflow of groundwater from the surrounding rock mass. Initial saturation of rock mass decreases as groundwater in rock mass is moved to bentnonite buffer by suction, but rock mass is saturated after inflow of groundwater from the far-field area. Stress changes at rock mass are compared to the Mohr-Coulomb failure criterion and the spalling strength in order to investigate the potential rock failure by thermal stress and swelling pressure. Additional simulations are conducted with the reduced spacing of deposition holes. The maximum temperature of bentonite buffer exceeds 100℃ as deposition hole spacing is smaller than 5.5 m. However, temperature of about 56.1% volume of bentonite buffer is below 90℃. The methodology of numerical modeling used in this study can be applied to the performance assessment of coupled THM processes for high-level radioactive waste repositories with various input parameters and geological conditions such as site-specific stress models and geothermal gradients.

The Survey of Dentists: Updated Knowledge about Basic Life support and Experiences of Dental Emergency in Korea

  • Cho, Kyoung-Ah;Kim, Hyuk;Lee, Brian Seonghwa;Kwon, Woon-Yong;Kim, Mi-Seon;Seo, Kwang-Suk;Kim, Hyun-Jeong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.14 no.1
    • /
    • pp.17-27
    • /
    • 2014
  • Background: Various medical emergency situations can occur during dental practices. Cardiac arrest is known to comprise approximately 1% of emergency situation. Thus, it is necessary for dentists to be able to perform cardiopulmonary resuscitation (CPR) to increase the chance of saving patient's life in emergency situation. In this paper, we conducted a survey study to evaluate to what extent dentists actually understood CPR practice and if they had experience in handling emergency situations in practice. Method: The survey was done for members of the Korean Dental Society of Anesthesiology (KDSA), who had great interest in CPR and for whom survey-by-mail was convenient. We had selected 472 members of the KDSA with a dental license and whose office address and contact information were appropriate, and sent them a survey questionnaire by mail asking about the degree of their CPR understanding and if they had experience of handling emergency questions before. Statistical analyses -frequency analysis, chi-square test, ANOVA, and so on- were performed by use of IBM SPSS Statistics 19 for each question. Result: Among 472 people, 181 responded (38.4% response rate). Among the respondents were 134 male and 47 female dentists. Their average age was $40.4{\pm}8.4$. In terms of practice type, there were 123 private practitioners (68.0%), 20 professors (11.0%), 16 dentists-in-service (8.8%), 13 residents (specialist training) (7.2%) and 9 military doctors (5%). There were 125 dentists (69.1%) who were specialists or receiving training to be specialist, most of whom were oral surgeon (57, 31.5%) and pediatric dentists (56, 30.9%). There were 153 people (85.0%) who received CPR training before, and 65 of them (35.9%) were receiving regular training. When asked about the ratio of chest pressure vs mouth-to-mouth respiration when conducting CPR, 107 people (59.1%) answered 30:2. However, only 27.1% of them answered correctly for a question regarding CPR stages, C(Circulation)- A(Airway)- B(Breathing)- D(Defibrillation), which was defined in revised 2010 CPR practice guideline. Dentists who had experience of handling emergency situations in their practice were 119 (65.6%). The kinds of emergency situations they experienced were syncope (68, 37.6%), allergic reactions to local anesthetic (44, 24.3%), hyperventilation (43, 23.8%), seizure (25, 13.8%), hypoglycemia (15, 8.3%), breathing difficulty (14, 7.8%), cardiac arrest (11, 6.1%), airway obstruction (6, 3.3%), intake of foreign material and angina pectoris (4, 2.2%), in order of frequency. Most respondents answered that they handled the situation appropriately under the given emergency situation. In terms of emergency equipment they had blood pressure device (70.2%), pulse oximetry (69.6%), Bag-Valve-Mask (56.9%), emergency medicine (41.4%), intubation kit (29.8%), automated external defibrillator (23.2%), suction kit (19.3%) and 12 people (6.6%) did not have any equipment. In terms of confidence in handling emergency situation, with 1-10 point scale, their response was $4.86{\pm}2.41$ points. The average point of those who received regular training was $5.92{\pm}2.20$, while those who did not was $4.29{\pm}2.29$ points (P<0.001) Conclusion: The result showed they had good knowledge of CPR but the information they had was not up-to-date. Also, they were frequently exposed to the risk of emergency situation during their dental practice but the level of confidence in handling the emergency situation was intermediate. Therefore, regular training of CPR to prepare them for handling emergency situation is deemed necessary.

Fabrication and Filtering Test of Nanoparticle-Stabilized Emulsion to be Suitable for Enhanced Oil Recovery (석유증진회수에 적합한 나노 에멀젼의 제조 및 필터링 시험 분석)

  • Son, Han Am;Lee, Keun Ju;Cho, Jang Woo;Im, Kyung Chul;Kim, Jin Woong;Kim, Hyun Tae
    • Economic and Environmental Geology
    • /
    • v.46 no.1
    • /
    • pp.51-61
    • /
    • 2013
  • Researches on the oil recovery enhancement using the nanotechnology has recently been studied in the United States. The previous researches has focused mainly on the flow characteristics of nanoparticles in porous media, and the stability of the nano-emulsion itself. However, the analysis did not deal with the size effects between a nano-emulsion and the pore size which has an important role when nano-emulsion flows in the porous media. In this research, nano-based emulsion was fabricated which is able to be applied for the enhanced oil recovery techniques and its characteristics was analyzed. In addition, in order to identify the characteristics of nano-emulsions flowing through the porous media, the size effect was analysed by filtering test. According to the results, when the emulsion was fabricated, SCA(Silane Coupling Agent) or PVA(Poly Vinyl Alcohol) are added to improve the stability of emulsion. As the ratio of the decane to water increased, the viscosity of emulsion and the droplet size also increased. For the filtering test at the atmospheric conditions, the droplet did not go through the filter; only the separated water from the emulsion was able to be filtered. This phenomenon occurred because the droplet was not able to overcome the capillary pressure. At the filtering test by suction pressure, most of the emulsion was filtered over the filter size of $60{\mu}m$. However, the ratio of filtration was rapidly degraded at less than $45{\mu}m$ filters. This is caused due to deformation and destruction of the droplet by strong shear stress when passing through the pore. The results from the study on the basic characteristic of nano-emulsion and filtering test will be expected to play as the important role for the fabrication of the stable nano-emulsion or the research on the recovery of residual oil in porous media.

Performance Test of a 75-tonf Rocket Engine Turbopump (75톤급 액체로켓엔진용 터보펌프 실매질 성능시험)

  • Jeong, Eunhwan;Kwak, Hyun-Duck;Kim, Dae-Jin;Kim, Jin-Sun;Noh, Jun-Gu;Park, Min-Ju;Park, Pyun-Goo;Bae, Jun-Hwan;Shin, Ju-Hyun;Wang, Seong-Won;Yoon, Suck-Hwan;Lee, Hanggi;Jeon, Seong-Min;Choi, Chang-Ho;Hong, Soon-Sam;Kim, Seong-Lyong;Kim, Seung-Han;Woo, Seong-Phil;Han, Yeong-Min;Kim, Jinhan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.2
    • /
    • pp.86-93
    • /
    • 2016
  • Performance tests of a 75-tonf liquid rocket engine turbopump were conducted. The performance of sub-components - two pumps and a turbine - and their power matching were measured and examined firstly near the design speed under the LN2 and kerosene environment. In the real propellant - LOX and kerosene - environment tests, design and off-design performance of turbopump were fully verified in regime of the rocket engine operation. During the off-design performance tests, turbopump running time was set longer than the engine operating time to verify the pump operability and set the pump inlet pressure close to design NPSHr to investigate pump suction capability in parallel. It has been found that developed-turbopump satisfied all of the engine required performances.

The Study on the Relationship Between the Duration of Chest Vibration prior to Endotracheal Suctioning and the Changes in Oxygen Saturation in Low-Birth-Weight Infants (저체중아에 있어 기관내 흡인전 흉부진동법의 기관과 산소포화 변화간의 관계 연구)

  • Ahn, Young-Mee
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.3
    • /
    • pp.597-607
    • /
    • 1995
  • 1960년대 이후 인공호흡기(mechanical ventilator)의 보급과 최근 의료과학의 발달, 간호의 질적 향상의 결과로 저체중출생아를 포함한 고위험 신생아의 생존율이 높아져왔다. 호흡장애증후군(RDS)은 일차적으로 폐포의 완전한 확장을 위해 필요한 계면활성물질(surfactant)의 부족, 미발달된 심폐기능에 의한 병리적 현상으로 저체중아의 가장 큰 원인이 되어왔다. RDS로 인해 인공호흡기에 의존해 있는 저체중아의 경우 적절한 산소공급과 이를 위한 호흡의 유지는 치료의 가장 큰 핵심이 되며, 이를 위한 기관내 흑은 비인두 흡인 (nasopharyngeal suction)은 신생아 중환자실(NICU)의 가장 중요한 간호행위가 되어왔다. 인공호흡기를 위한 기관삽관은 그 자체가 기도의 성모운동을 방해하고 기침반사를 억제시켜 폐 분비물의 효과적 배출을 억제하며, 특히 저체중아의 경우 조산과 관련하여 미발달된 흥곽운등과 심폐기능은 폐분비물의 이동을 저해하는 요소이다. 따라서 기도내의 분비물의 이동을 효과적으로 하여 흡인 시에 최대한의 효과를 돕기 위해 흥곽 물리요법(chest physiotheraphy : CPT)의 한 형태인 흉곽진동법 (Chest Vibration : CV)가 행해져 왔다. 그러나 저체중아를 위한CV의 임상적 적용은 그 대상의 생리적 특성, CV의 적용부위(site)와 기간(duration)에 대한 과학적 근거 없이 만성감염이나 폐질환을 가진 성인이나 cystic fibrosis환자를 위한 CV protocol을 무분별하게 채택하여 저체중아에게 행하여져 왔다 이에 본 연구자는 저체중아에 대한 CV의 안전성을 평가하고, 이에 기초하여 저체중아에게 바람직한CV의 형태를 알아보고자 본 연구를 시작하였다. 연구설계는 CV의 안전성을 평가하기 위한 실험연구이다. CV의 안전성은 RDS치료의 가장 일차적 목표인 oxygenation변화에 의해 평가될 수 있으므로, 본 실험 연구에서는 Pulse oximeter에 의해 계속적으로 측정된 산소포화 변화(oxygen saturation change)를 측정하였다. 실험대상은 미국동부에 위치한 대학병원의 NICU에 입원하여 RDS와 관련된 호흡장애로 인공호흡기에 의존해 있는 10명의 저체중아였다. 인공호흡기에 의존된 모든 저체중아는 Pulse oximeter와 심폐기능 측정기(cardiopulmonary monitor)에 의해 산소공급과 호흡상태가 계속 측정되고 있었다. 실험대상의 평균 출생시 몸무게는 평균 1,3050gm(SD=580.6)이었고, 임신월령 은 평균 28.6주(SD=3.1)였다. RDS가 그들의 일차적 진단명이었고, 그중 4명은 pneumonia, atelectasis의 합병증을 가지고 있었다. 10명중 6명은 intermittent mandatory ventilation(IMV)의 형태로, 4명은 continuous positive airway pressure(CPAP)의 형태로 인공호흡기에 의존되어 있었고 CV시의 FiO2는 평균 42.3(SD=21.2)였다. CV는 중환아용 소형진동기 (minivibrator)를 이용해 가각 10명 의 간호사에 의해 행하여 졌고, 최소 22초에서 최대 100초 동안 실시되었다. 50%의 간호사는 30초에서 40초간 CV를 실시하였으며, CV의 적용부위도, 전후 흉곽부위, 혹은 병변이 있는 좌 우측, 흑은 양쪽 흉벽 등으로 다양했고, 적용방법도 원형으로 돌려가며(circular motion), 혹은 아래에서 위로, 혹은 아무런 기준없이 간호사의 기호에 따라 다양하게 적용되었다. 산소포화의 변화는 CV가 행해지기 전.후로 5초동안 관찰되었다. 연구의 결과, 산소포화 변화는 비 모수통계(non parametric statistics)의 일종인 Matched Paired Wilcoxon test로 분석 한 결과 CV후에 3%의 감소를 보였다(P<.05). 저체중아에 있어 산소포화의 3%감소는 임상적으로 중요한 의미가 없다고 사료되어지며, 실제 흡인전의 과도호흡에 의해 CV를 행하기 이전의 산소공급수준으로 돌아 왔다. CV실시 기간과 산소포화와의 상관관계는 비 모수통계인 Spearman rho correlation coefficient를 이용하여 분석하였는데, 이 두 변수는 서로 관계가 없는 것으로 나타났다(P>.05) 또한 CV와 흡인 후에 각각의 간호사들에게 CV를 필요로 한 저체중아의 기준, 적용부위, 기간, 방법등에 대한 기준을 물었으나 대상의 특성에 따른 간호사정에 의존하기보다는 간호사 각자의 선호하는 방법이나 습관에 라 행하는 것으로 나타났다. 결론적으로 CV와 산소포화 변화와의 관계, NICU에서 관찰된 CV의 임상적 적용을 기초로 저체중아에게 안전한 CV protocol은 신생아용 소형 진동기를 이용하여, 양쪽 흉곽의 늑골하측 변연 부위(low lateral costal margin)에서 시작하여 흉골 중앙부위 방향으로 30초 동안 진동기를 적용하는 것이 좋은 것으로 나타났다. 이에 CV의 효과를 평가하기 위한 보다 과학적인 접근방법으로, CV와 흡인의 결과인 가래(sputum)에 대한 연구를 제언하는 바이다.

  • PDF