• 제목/요약/키워드: Suction power

검색결과 155건 처리시간 0.025초

다중 노즐을 이용한 중앙 분사형 제트 펌프의 성능에 관한 연구 (A Study on the Characteristics of Jet Pump Having Exteriorly Connected Multi-nozzles)

  • 김명관;권오붕;김형근;이천근
    • 동력기계공학회지
    • /
    • 제4권1호
    • /
    • pp.33-38
    • /
    • 2000
  • The characteristics of center-driver jet pump which have multi-nozzle were studied in this research. Jet nozzles are connected outside of the bend rather than inserted in the bend in order to transport solid materials or fish without any harm. Jet pumps having one nozzle, two nozzles, four nozzles, and sixteen nozzles were tested in this study. The efficiencies and performances of jet pumps were studied for several nozzles shape, for three different mixing chamber shapes, for two suction area shapes. All the efficiency curves for these cases are presented in this paper.

  • PDF

Fault Detection and Diagnosis of the Deaerator Level Control System in Nuclear Power Plants

  • Kim Kyung Youn;Lee Yoon Joon
    • Nuclear Engineering and Technology
    • /
    • 제36권1호
    • /
    • pp.73-82
    • /
    • 2004
  • The deaerator of a power plant is one of feedwater heaters in the secondary system, and it is located above the feedwater pumps. The feedwater pumps take the water from the deaerator storage tank, and the net positive suction head(NSPH) should always be ensured. To secure the sufficient NPSH, the deaerator tank is equipped with the level control system of which level sensors are critical items. And it is necessary to ascertain the sensor state on-line. For this, a model-based fault detection and diagnosis(FDD) is introduced in this study. The dynamic control model is formulated from the relation of input-output flow rates and liquid-level of the deaerator storage tank. Then an adaptive state estimator is designed for the fault detection and diagnosis of sensors. The performance and effectiveness of the proposed FDD scheme are evaluated by applying the operation data of Yonggwang Units 3 & 4.

EDISON CFD를 이용한 100 kW 수평축 조류발전 터빈 주위 유동 해석

  • 오승진;남권우
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제6회(2016년)
    • /
    • pp.15-18
    • /
    • 2016
  • 본 연구는 조류발전 터빈의 블레이드 형상 최적화 해석 시스템 개발에 대한 사전연구의 일환으로 EDISON CFD의 프로펠러 단독성능 S/W와 SNUFOAM ShipMesh Advanced 자동격자생성기를 이용하여 조류발전 터빈 주위 유동장에 대한 수치해석을 수행하였다. TSR 조건 변화에 따라 수치해석을 수행하고 이에 대한 power, total coefficient를 동일한 조건에서 수행된 실험결과와 비교 검증하여 해석자의 신뢰도를 확인하였다. 또한, 블레이드 전체를 모델링한 full body 해석과 하나의 블레이드만을 모델링한 single body 해석 결과를 비교하여 경제적이면서 정도 높은 터빈 성능해석 프로세스를 제안하였다. 조류발전 터빈의 TSR 조건 변화에 따라 낮은 TSR 조건에서는 국부적 와동발생에 의해 $C_P$가 감소하는 것을 확인하였고 설계 TSR에서 가장 좋은 효율을 보임을 확인하였다. 이를 통해 suction side의 압력 분포, 팁 와동의 강도 등 성능개선을 위한 주요한 설계변수를 식별하였다.

  • PDF

내부 열교환기를 이용한 R-1270용 냉동시스템의 성능 분석 (Performance Analysis of R-1270(Propylene) Refrigeration System Using Internal Heat Exchanger)

  • 구학근
    • 동력기계공학회지
    • /
    • 제18권4호
    • /
    • pp.36-42
    • /
    • 2014
  • This paper considers the influence of internal heat exchangers on the efficiency of a refrigerating system using R-1270. These internal heat exchangers(liquid-gas or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as the mass flowrate of R-1270, inner diameter tube and length of internal heat exchanger, to optimal dimensions of the heat exchanger is also analyzed. The main results were summarized as follows : the mass flowrate of R-1270, inner diameter tube and length of internal heat exchanger, and effectiveness have the influences on the cooling capacity, compressor work and RCI(Relative Capacity Index) of this system. With a thorough grasp of it is possible to design the R-1270 compression refrigeration cycle using internal heat exchanger.

차세대 신형원자로의 피동형 안전 주입장치를 위한 프리피스톤 스터링 펌프의 동특성 모델 (Dynamic Modeling of the Free Piston Stirling Pump for the Passive Safety Injection of the Next Generation Nuclear Power Plant)

  • Lee, Jae-Young
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 추계 학술발표회 논문집
    • /
    • pp.149-154
    • /
    • 1999
  • This paper describes a passive safety injection system with free piston Stirling pump working withabundant decay heat in the nuclear reactor during the hypothetical accident. The water column in the tube assembly connected from the hot chamber to the cold chamber in the pump oscillates periodically due to thermal volume changes of non-condensable gas in each chamber. The oscillating pressure in the water column is converted into the pumping power with a suction-and-bleed type valve assembly. In this paper a dynamic model describing the frequency of oscillation and pumping pressure is developed. It was found that the pumping pressure is a function of the temperature difference between the chambers. Also, the frequency oscillation depends on the length of the tube with water column.

  • PDF

VIBRO-ACOUSTIC TROUBLESHOOTING SOLVES 5MW BOILERFEED PUMP TESTRING NOISE & VIBRATION PROBLEMS

  • Gielen, L.;Vandenbroeck, D.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.836-841
    • /
    • 1994
  • This paper describes the global vibro-acoustic troubleshooting approach, used to identify and separate different sources of noise and vibrations on a boilerfeed pump testrig. The pump serves for rotor dynamic research of a EC-funded BRITE-Euram profect. This approach resulted in the identification of local structural flexibilities in the connections between the machinery and the base plate. The relative importance of the modes during normal operation is revealed by comparison with operational deformation shapes. The use of sound intensity mapping allowed to calculate the total sound power and to rank the equipment according to its sound power contribution. High acoustic levels were found and related to the fluid drive and to the piping system. Modification of the piping section resulted in a reduction of noise and vibration levels along the test loop and smooth operation in a wide suction pressure range.

  • PDF

공기압축기 성능향상을 위한 로터 프로파일 설계기술 개발 연구 (Development of rotor profile design technology for improving the screw compressor performance)

  • 김태윤;이재영;이동균;김윤제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.585-592
    • /
    • 2009
  • The performance of screw compressor depends on lots of design parameters of rotor profile, such as length of seal line, wrap angle, blow hole, suction and discharge port size, number of rotor lobe, etc. The optimum rotor profile makes it possible to increase the compression efficiency with low energy consumption, and to minimize the loss of power. In this research, a new rotor profile design and performance analysis are done by computer simulation. It is expected that the volumetric efficiency is improved because the internal leakage is reduced due to the minimization of blow hole and clearance, and the stiffness of rotors is increased due to the reduction of length to diameter ratio. Also, the specific power consumption will be secured for use ranging from low to high operation speed.

  • PDF

Design and Prediction of Three Dimensional Flows in a Low Speed Highly Loaded Axial Flow Fan

  • Liu, Xuejiao;Chen, Liu;Dai, Ren;Yang, Ailing
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권2호
    • /
    • pp.94-104
    • /
    • 2013
  • This paper describes the design to increase the blade loading factor of a low speed axial flow fan from normal 0.42 to highly loaded 0.55. A three-dimensional viscous solver is used to model the flows in the highly-loaded and normal loaded stages over its operation range. At the design point operation the static pressure rise can be increased by 20 percent with a deficit of efficiency by 0.3 percent. In the highly loaded fan stage, the rotor hub flow stalls, and separation vortex extends over the rotor hub region. The backflow, which occurs along the stator hub-suction surface, changes the exit flow from the prescribed axial direction. Results in this paper confirm that the limitation of the two dimensional diffusion does not affect primarily on the fan's performance. Highly loaded fan may have actually better performance than its two dimensional design. Three dimensional designing approaches may lead to better highly loaded fan with controlled rotor hub stall.

Power Assisted Liposuction(PAL)과 병용한 외부 초음파의 효과에 대한 비교 연구 (A Comparative Study of the Effect of External Ultrasound with Power Assisted Liposuction(PAL))

  • 송인수;박준;유영천;양원용;김진영
    • Archives of Plastic Surgery
    • /
    • 제32권4호
    • /
    • pp.496-502
    • /
    • 2005
  • This study was performed to compare the effect of external ultrasound assisted PAL(power assisted liposuction) with that of PAL alone. We performed 17 cases of liposuction from January 2003 to June 2003. For comparing both systems, we treated the right side(study group) with external ultrasound assisted PAL and the left side(control group) with PAL alone. To evaluate the difference in results between two groups, we surveyed three objective and four subjective items. Objectives were categorized as "Reduction rate of postoperative swelling", "Efficiency of suction" and "Histologic finding of aspirated fat tissue". Subjectives were also filed as "Degree of postoperative bruising", "Cannula resistance that operator felt", "Degree of postoperative pain" and "Patient's satisfaction". We assessed by questionnaire three times at 1day, 7 days and 30 days after operation. There were statistically significant differences in two of the subjective items; "Degree of postoperative pain at postoperative 1 day" and "Cannula resistance that operator felt". This study concludes that external ultrasound PAL is more effective high mobility of fat tissue and low tension of surrounding tissue. External ultrasound PAL will be more useful in case of large volume liposuction and revision procedures.

Numerical simulation Analysis of Tip Clearance Flow in a Centrifugal Compressor

  • Zhou, Shuiqing;Wang, Jun;Wang, Chuanghua;Li, Ye
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권1호
    • /
    • pp.28-33
    • /
    • 2014
  • In order to research the relationship between the tip clearance and leakage flow of centrifugal compressor, a high speed centrifugal compressor was investigated by using CFD. A numerical study on the effect of four different rotor tip clearance sizes of centrifugal compressor, which were 0.5times, 1 times, 1.5times and 2.0times of the design tip clearance, was carried out. Efficiency and pressure ratio curves were obtained under different mass flow. The reasons of the clearance vortex and the factors of vortex size were analyzed. The result indicated that with the increase of tip clearance size, the performance of the compressor changed obviously, the performance parameters such as efficiency and pressure ratio tended to decrease obviously. While, the leakage flow does not always lead to leak vortex. The strength of the vortex increased with the tip clearance. The size of leak vortex was affected by the pressure difference between the suction side and the pressure side of blade tip.