• 제목/요약/키워드: Suction fan

검색결과 63건 처리시간 0.026초

축류형 흡배송 송풍기의 성능에 관한 실험적연구 (A Experimental Study on the Performance of an Axial-Type Suction-Blowing Fan)

  • 최형준;박영하;안국영;조수용
    • 한국유체기계학회 논문집
    • /
    • 제14권4호
    • /
    • pp.19-24
    • /
    • 2011
  • An experimental study was conducted to examine the effectiveness of a suction-blowing fan that could not only remove polluted air by suction but also create the air-curtain by blowing. In order to create the air-curtain, rotors were installed on the surface of the shroud. These blows fresh air into the polluted region. The fresh air is spouted backward 45o on the basis of the axial direction using a double-ducted bellmouth. In the same suction operating condition, the suction region was extended by increasing the blowing velocity. However, the increasing rate of suction region was reduced when the blowing velocity was increased steadily. Thus, an efficient blowing velocity should be determined depending on the suction operating condition. In addition, the blowing requires additional input power. In a fixed suction operating condition, the input power was linearly increased in proportion to the blowing flowrate. When the suction-blowing fan was operated in the same input power as the suction fan, the suction region was increased more than 30% based on the 0.6m/sec velocity.

횡류팬을 적용한 진공청소기 흡입노즐내 유동 소음 저감에 관한 연구 (Reduction of Flow-Induced Noise in Suction Nozzle of a Vacuum Cleaner by Adopting a Cross-Flow Fan)

  • 박이선;손채훈;이성철;오장근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.935-938
    • /
    • 2007
  • In suction nozzle of a vacuum cleaner, where flow-induced noise is generated mainly by flow resistance, several ideas to reduce noise are investigated. To increase fan performance, blade number is optimized and a centrifugal fan is replaced by a cross-flow fan, In addition, gear ratio of fan to drum brush is changed. It is found that fan performance is increased by adopting these methods. Next, the blade height of the fan is decreased to reduce sound pressure level, which causes inevitably decrease in fan performance. Eventually, flow-induced noise is reduced by 6.3 dBA in its overall level with the fan performance maintained.

  • PDF

이중 블레이드 팬이 장착된 진공청소기 흡입 노즐내 유로 유동 소음 및 팬 성능 해석 (Numerical Analysis of Flow-Induced Noise and Fan Performance in Suction Nozzle of a Vacuum Cleaner with a Double-Blade Fan)

  • 박이선;손채훈;이성철;오장근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2632-2637
    • /
    • 2007
  • Rotary performance and flow resistance induced by each element in suction nozzle of a vacuum cleaner with a double-blade rotary fan are investigated numerically and its relation with flow-induced noise and rotary performance is examined. Flow resistance and vorticity in suction nozzle are calculated and it is found that they are closely related with flow-induced noise. Gap between double blades, adoption of cross-flow fan, enlargement of flow inlet area, and optimization of blade number are tested for noise reduction. Finally, the effects of each method are verified experimentally. It is found that several combinations of the proposed methods can be adopted for noise reduction although the degree of reduction is not much.

  • PDF

벼 상온통풍건조시설의 송풍특성 (Airflow Characteristics of Natural Air Drying for Rough Rice)

  • 이효재;김훈;한재웅
    • 한국지역사회생활과학회지
    • /
    • 제24권3호
    • /
    • pp.391-397
    • /
    • 2013
  • This study was conducted to define the characteristics of the fan according to the bed depth of rough rice for the silo used in South Korea. In this study, the characteristics like air flow resistance and air flow rate of the fan were investigated for an independent blowing system with 1 fan and the serial blowing system with 2 fans. In the experiment, the depth of rough rice was determined by 0, 1, 2, 3.2 and 4.5 m for an independent blowing system and the depth of rough rice was 4.5 m for the serial blowing system. The air flow resistances of the blowing fan and the suction fan in an independent blowing system were 55 mmAq and 88 mmAq respectively. In addition, the air flow resistance of the serial blowing system was 61% lower than the blowing fan and 28% lower than the suction fan of the independent blowing system. The air flow rates of the blowing fan and the suction fan in the serial blowing system were 516 $m^3/min$, 570 $m^3/min$, respectively. The former was 22% higher than the blowing fan while the latter was 29% higher than the suction fan in the independence blowing system. In other words, the serial blowing system was superior to the independent blowing system in blowing characteristics because the air flow rate was lower and air flow resistance was higher than the independent blowing system. However, the fan power consumption of the serial blowing system was more than 100% comparing with the independent blowing system.

Crossflow fan에 의한 컴퓨터 케이스 내부의 유동특성에 관한 연구 (A Study on the Flow Characteristics in Computer Case by Crossflow Fan.)

  • 이행남;박길문;정한별
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권5호
    • /
    • pp.730-736
    • /
    • 2008
  • The purpose of this study is to find out a flow characteristics when a crossflow-fan is installed inside the computer case and to provide information about the preliminary data of cooling efficiency of CPU and a flow inside and outside of a computer case. Under the condition of operating the fan inside the experimental duct we changed the position of a installation of the slot, and the experiment measured with PIV and the results are as follows. Under the influence of the crossflow-fan installed to the air discharging side, mean velocity between 35 to 45 on the point 80 of the Slot 0.2.3 of the case increased and it influences discharging the air inside of the computer case. On the left-upper end. which isn't directly influenced by the suction-discharging fan installed inside the PC, a flow occurs caused by vortex due to the Sirocco-Fan and Slot installed on the center of the right side. We can see that a flow distribution increases when the Sirocco-Fan operates and a whirl appears stronger between the slot and the suction fan. It is thought that this phenomenon is influenced by a flow while it is on the way of entering from the suction-fan and going out to the discharging-fan.

축류형 흡입송풍기 설계기술에 관한 연구 (A Study of Design Method of an Axial-Type Suction Fan)

  • 최형준;김창수;조종현;조수용
    • 한국유체기계학회 논문집
    • /
    • 제13권1호
    • /
    • pp.42-51
    • /
    • 2010
  • Many different types of fan have been applying to various industrial fields. Fan design methods are much different depending on the types of fan, operating conditions, and connecting parts at the inlet or exit of the fan etc. In this study, design methods for an axial-type suction fan are studied. This fan discharges the air in the relative static pressure of -285Pa to the atmosphere with the flow rate of $960m^3/min$. For three-dimensional blade design, three different design methods were applied, such as the free vortex method, the exponential method, and the cascade method. In the cascade method, the blade loading along the radial direction was obtained from the lift coefficient which was necessary to obtain the pressure rise on a fan rotor. This method is different from the free vortex and the exponential method which control the strength of the vortex. The fan performance prediction was conducted using the CFD with three different inlet ducts. The best fan performance was obtained when the fan was designed by using the cascade method. The designed fan using the exponential method showed better performance compared to a fan designed using the free vortex method. However, the fan performance was changed depending on the installed inlet ducts. So, an efficient fan can be designed with the adjustment of design variables on the basis of the flow structures within the fan as well as the fan design procedure.

팬이 장착된 진공청소기 흡입 노즐내 유로 유동 소음해석 (Numerical Analysis of Flow-Induced Noise in Suction Nozzle of a Vacuum Cleaner with a Rotary Fan)

  • 박이선;이성철;오장근;손채훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.208-211
    • /
    • 2006
  • Flow resistance induced by each element in suction nozzle of a vacuum cleaner with a rotary fan is investigated numerically and its relation with flow-induced noise is examined. Flow resistance and vorticity in suction nozzle are calculated and it is found that they are closely related with flow-induced noise. From numerical results, it is suggested that reduction of flow resistance effectively increases all-suction performance and decreases sound pressure level of noise generated in the suction nozzle.

  • PDF

다익 홴/스크롤 시스템의 형상변수와 내부 유동장 특성과의 관계 (Some Relations Between the Geometric Parameters and Internal Flow Field Characteristics in Multiblade Fan/Scroll System)

  • 맹주성;유달현;이광호;박인규
    • 대한기계학회논문집B
    • /
    • 제24권9호
    • /
    • pp.1139-1147
    • /
    • 2000
  • This paper describes that the size of inactive zone can be directly applied to design multiblade fan/scroll system. From the experimental studies using a five hole pitot tube and smoke test, it is found that the size of inactive zone has linear relations with the mean velocity of impeller inlet and cut-off angle gives a great influences to the fan efficiency. For the practical design, a function related with geometric parameters(i.e. inner radius, cord length, cut-off clearance and cut-off angle) of fan/scroll system is suggested. By using these formulas, the size and distribution of inactive zone can be predicted without the measurements through the full domain, it can be possible to use them to know the efficiency improvement for new model designed.

렌지후드의 성능개선을 위한 시로코 팬 주위의 유동해석 (PERFORMANCE IMPROVEMENT OF A RANGE HOOD SIROCCO FAN BY CFD FLOW ANALYSIS)

  • 한병윤;박진우;이명수;박형구
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.159-165
    • /
    • 2008
  • A sirocco fan is widely used for discharging pollutants of a kitchen space since it is able to generate a relatively high air flow rate considering its small size and makes less noise than a axial fan or a centrifugal fan. However, it has a problem because its efficiency is low, and power consumption is larger. Performance of a sirocco fan is influenced by various factors such as number of the fan blades, diameter of the fan, geometry of the fan, geometry of its housing, revolution frequency, static pressure condition, and etc. This research investigated the effect on the performance of geometry of the housing. For CFD analysis, we used a commercial code, SC/Tetra, and used a sliding mesh method to give the same condition as an actual state. Verification of the CFD results is done by comparison of experimental data and numerical one about the suction flow rate, and it is confirmed that two results are well consistent. After we changed the shape of housing according to Archimedes' screw, we observed that suction efficiency is improved by 10.7% maximum.

  • PDF

수치해석에 의한 스플리터 부착 원심송풍기 성능특성 연구 (Performance Analysis of a Centrifugal Fan with Splitters)

  • 장춘만;최가람;양상호
    • 대한기계학회논문집B
    • /
    • 제35권10호
    • /
    • pp.1067-1073
    • /
    • 2011
  • 본 연구에서는 생활폐기물 관로이송 설비에 사용되고 있는 원심송풍기의 성능향상을 위해 임펠러날개 압력면과 부압면 측에 스플리터를 각각 설치하고, 스플리터의 코드길이 변화에 따른 성능특성을 삼차원 나비어-스톡스 방정식을 이용한 수치해석으로 분석하였다. 수치해석을 통한 기초연구를 바탕으로 날개 부압면측에서 발생하는 역류현상을 억제할 수 있는 스플리터의 익간설치를 고려하였으며, 주요설계 변수로는 코드길이를 설정하였다. 이를 통해 날개 부압면 측에 설치한 스플리터의 코드길이가 길어질수록 원심송풍기 압력 및 효율특성이 설계유량 조건 뿐만 아니라 유량증가에 따라 향상됨을 알수 있었다. 설계유량 조건에서 스플리터 부착 원심송풍기에 의해 효율 및 압력은 기존대비 각각 4% 및 18% 향상되었다.