• Title/Summary/Keyword: Suction Pressure

Search Result 687, Processing Time 0.029 seconds

Study on the Improvement for Measuring Procedures of Volumetric Pressure Plate Extractor (체적압력판추출기의 측정법 개선에 관한 연구)

  • Yoo, Kun-Sun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4C
    • /
    • pp.185-191
    • /
    • 2010
  • Volumetric pressure plate extractor (VPPE) can be used for measurement of the soil-water characteristic curve in the laboratory using the axis-translation technique. The volume of extracted water from the soil specimen in VPPE can be measured continuously during the test without stoppage of air pressure for the measurements. However, the water volume measurement in VPPE using an air trap, a ballast tube, a burette, and a vacuum device so as to maintain a constant pore-water pressure in the soil specimen, is quite complicated and tedious. In order to improve the measuring problems of VPPE, a modified volumetric pressure plate extractor (MVPPE) was developed and tested on residual soil specimens. In addition, the modified apparatus can measure the volume of the extracted water using both Method A and Method B of ASTM D 6836-02 depending on the range of matric suction. Measuring principles and the improvements of MVPPE and typical results obtained from the tests are discussed in the paper.

A Study on the Performance Characteristic of Common Rail High Pressure Pump (커먼레일 시스템용 고압펌프의 성능 특성에 관한 연구)

  • Lee, Choon-Tae
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.5-10
    • /
    • 2013
  • Diesel engines have the advantages of good fuel efficiency and low emissions. Therefore, car makers have been developed various kinds of diesel engine management system to clean up emissions while improving fuel efficiency. One of them is the common rail system. In the common rail system, diesel fuel is injected into the combustion chamber at ultra high pressures up to 1,800 bar to ensure more complete combustion for cleaner exhaust gas, and highly precise multiple injection reduces NOx emission, combustion noise and vibration. Generally speaking, common rail system consists of booster pump, high pressure pump, common rail, injectors, control valves, and sensors. The high pressure pump receives low pressure fuel from the booster pump and supply high pressure fuel to injectors through the high pressure common injection rail. Therefore, high pressure pump has an important role in common rail system. In this paper, we have investigated the performance of high pressure pump of common rail system.

Analysis on Characteristic of Pressure Fluctuation in Hydraulic Turbine with Guide Vane

  • Shi, FengXia;Yang, JunHu;Wang, XiaoHui
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.3
    • /
    • pp.237-244
    • /
    • 2016
  • An unsteady three-dimensional simulation based on Reynolds time-averaged governing equation and RNG $k-{\varepsilon}$ turbulence model, was presented for pump-as-turbine, the pressure fluctuation characteristic of hydraulic turbine with guide vane was obtained. The results show that the time domains of pressure fluctuation in volute change periodically and have identical cycles. In volute tongue and inlet pressure fluctuations are light, while in dynamic and static coupling interface pressure fluctuations are serious; In impeller blade region the pressure fluctuation of pressure surface are lighter than that of suction surface. The dominant frequencies of pressure fluctuation concentrate in low frequency region, and concentrate within 2 times of the blade passing frequency.

Experimental Study on the Behavior of Stall Cell in an Axial Flow Fan (축류송풍기의 실속셀 거동에 관한 실험적 연구)

  • Shin You Hwan;Kim Kwang Ho;Kang Chang Sik
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.643-646
    • /
    • 2002
  • Experimental study was conducted to reveal the flow mechanism under rotating stall in an axial flow fan. For this study unsteady pressure was measured using high frequency pressure transducers mounted on the casing wall of rotor passage and total pressure fields were measured at the rotor upstream and downstream. The measured pressure signal was analyzed by Wavelet Transform and Double Phase Locked Averaging Technique. From the result of unsteady pressure field of the casing wall, one period of rotating stall was divided into three zones and the flow characteristics on each zone were described in detail. The pressure field was also analyzed in terms of the pressure distribution along pressure side and suction side of blade tip. From the result of total pressure fields at inlet and outlet of the rotor, the useful information on the characteristics of the stall cell in radial direction was provided.

  • PDF

Pressure Variation Characteristics at Trapping Region in Oil Hydraulic Piston Pumps (유압 피스톤 펌프의 폐입 구간에서의 압력 변동 특성)

  • Kwag Jae-ryon;Oh Seok-Hyung;Jung Jae-Youn
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.329-334
    • /
    • 2003
  • Design of pre-compression region(trapping region) of the valve plate is an important element to minimize the pressure fluctuation in a cylinder and in discharge process, and pump noise. In this study, we tried to prove what the characteristics of the oil hydraulic pump would be according to the angle of the trapping region. Three kinds of asymmetrical valve plates were used. As a result, we found that by designing the trapping region, the slope of the pressure rise in the cylinder port from low-pressure suction region to high-pressure discharge region is relaxed and the pressure fluctuation width and the discharge pressure pulsation are reduced. Therefore, because the pump gets smooth pressure fluctuation and low fluid Impact, the pump noise is reduce.

  • PDF

An Experimental Study on Flow in the Nozzle of a Radial Turbine (구심터빈의 노즐 내부 유동에 대한 시험 연구)

  • Kang, Jeong-Seek;Lim, Byeung-Jun;Ahn, Iee-Ki
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.1
    • /
    • pp.35-41
    • /
    • 2010
  • Experimental study on the flow field inside the nozzle for radial turbine was performed. At design point, the pressure is high and the Mach number is low at the pressure side of the nozzle inlet semi-vaneless space as the flow turns through the nozzle vanes. As the flow accelerates through the nozzle passage to the throat the pressure level at the pressure and suction sides becomes similar. The flow continued accelerating from the throat to the inlet of turbine wheel and the pressure field became uniform in the circumferential direction in the vaneless space. In high expansion ratio condition, strong favorable pressure gradient band region occurred just after the throat in the semi-vaneless space in the circumferential direction and the pressure became uniform in the circumferential direction after this band. In low expansion ratio condition, core flow acceleration is dominant after the throat and this non-uniform pressure field reached to the inlet of turbine wheel.

Wall-Suction Assisted Vacuum Sealing for Treatment of Infected Diabetic Foot Ulcer (벽매립형 중앙 흡인장치를 이용한 감염성 당뇨병성 족부 궤양의 밀봉 치료)

  • Bae, Su-Young;Lee, Chang-Wook;Seo, In-Seock
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.26-30
    • /
    • 2004
  • Purpose: The infected diabetic foot patients were reviewed to analyze the result of new dressing methods using a wall-suction instruments. Materials and Methods: Eighteen patients treated with wall-suction assisted vacuum dressing were included. After debridement under local anesthesia, a sponge pad, a drain, and a surgical drape were used to seal the wound. Negative pressure applied by the wall-suction at around 200 mmHg and dressing were repeated in every two to three days. The results of repeated wound cultures, growth of granulation tissues, and CRP level were closely observed on the regular basis. Results: Rapid growth of granulation tissues was noticed around the wound in 16 cases. No organism was obtained in an average 5 days and wound coverage was possible in an average 18 days. The CRP level returned to normal in an average 4 weeks. Two patients with end stage renal disease, who were regularly hemodialised, underwent major amputation. Conclusion: New dressing method has the following advantages: a rapid wound improvement in the patients with infected diabetic foot, less expensive, less painful, impediment of bacterial contamination in the hospital room. However, further study will be needed for the end stage renal disease patients.

  • PDF

The Study of Blister Caused by Cupping Therapy (부항 시술에 의해 형성된 수포에 관한 고찰)

  • Yun, Hye-Yeon;Kwon, Sun-Oh;Kim, Seung-Tae;Park, Hi-Joon;Hahm, Dae-Hyun;Lee, Hye-Jung
    • Korean Journal of Acupuncture
    • /
    • v.28 no.3
    • /
    • pp.141-150
    • /
    • 2011
  • Objectives : The aims of this study were to evaluate a blister caused by cupping. Methods : We searched relevant case reports, survey, and review articles using databases of online bibliography. Results : 1. The fluid in the blister caused by cupping therapy is normal substance by laboratory analysis. The fluid has no signs of infection in the culture, Gram stain, or tissue biopsy 2. In histological finding, the blister caused by cupping therapy is made by dermo-epidermal seperation at subcellular level. Suction blistering was neither inflammatory nor autolysis activation of lysosomal hydrolases. 3. Blistering times directly, related to suction pressure. Suction blister formation time is accelerated in older subjects compared with younger individuals and higher temperature was more susceptable to the blister compared with lower temperature. The flexor aspect of forearm is a easy site for suction blister formation compared with leg and abdominal site. 4. Blister caused by cupping therapy is treated by regular and judicious changes of sterile dressing over several weeks. The vesicles healed well and left no visible scar. Conclusions : Blister caused by cupping therapy is artificially controlled by doctor's therapeutic purpose. Blister is not histologically injurious to health and the blister is a natural concomitant after cupping therapy.

Multi-dimensional wind vibration coefficients under suction for ultra-large cooling towers considering ventilation rates of louvers

  • Ke, S.T.;Du, L.Y.;Ge, Y.J.;Tamura, Y.
    • Structural Engineering and Mechanics
    • /
    • v.66 no.2
    • /
    • pp.273-283
    • /
    • 2018
  • Currently, the dynamic amplification effect of suction is described using the wind vibration coefficient (WVC) of external loads. In other words, it is proposed that the fluctuating characteristics of suction are equivalent to external loads. This is, however, not generally valid. Meanwhile, the effects of the ventilation rate of louver on suction and its WV are considered. To systematically analyze the effects of the ventilation rate of louver on the multi-dimensional WVC of ultra-large cooling towers under suctions, the 210 m ultra-large cooling tower under construction was studied. First, simultaneous rigid pressure measurement wind tunnel tests were executed to obtain the time history of fluctuating wind loads on the external surface and the internal surface of the cooling tower at different ventilation rates (0%, 15%, 30%, and 100%). Based on that, the average values and distributions of fluctuating wind pressures on external and internal surfaces were obtained and compared with each other; a tower/pillar/circular foundation integrated simulation model was developed using the finite element method and complete transient time domain dynamics of external loads and four different suctions of this cooling tower were calculated. Moreover, 1D, 2D, and 3D distributions of WVCs under external loads and suctions at different ventilation rates were obtained and compared with each other. The WVCs of the cooling tower corresponding to four typical response targets (i.e., radial displacement, meridional force, Von Mises stress, and circumferential bending moment) were discussed. Value determination and 2D evaluation of the WVCs of external loads and suctions of this large cooling tower at different ventilation rates were proposed. This study provides references to precise prediction and value determination of WVC of ultra-large cooling towers.

Analysis of an Actual Slope Failure in the Residual Soil by Suction Stress Based Effective Stress (흡수응력에 기반한 유효응력에 의한 실제 잔류토 사면 붕괴의 해석)

  • Oh, Seboong;Lu, Ning;Park, Young Mog;Lee, Junsuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3C
    • /
    • pp.113-120
    • /
    • 2012
  • An actual slope failure was analyzed in residual soils at Jinju. Due to rainfall infiltration, the safety factor decreases in the unsaturated layers, since the effective stress and shear strength decrease. In this study, the effective stress is based on suction stress using soil water retention curve. Unsaturated properties were evaluated on soil water retention curve, hydraulic conductivity and shear strength with samples from the site. After infiltration analysis of unsaturated flow under the actual rainfall, the distribution of pore water pressure could be calculated in the slope layers. In the stress field of finite elements, an elastic analysis calculated total stress distribution in the layers and also shear stresses on the slip surface using elastic model. On the slip surface, suction stress and effective stress evaluated the shear strength. As a result, the factor of safety was calculated due to rainfall, which could simulate the actual slope failure. In particular, it was found that the suction stress increases and both the effective stress and the shear strength decrease simultaneously on the slip surface.