• 제목/요약/키워드: Suction Pressure

검색결과 686건 처리시간 0.031초

가스 터빈 블레이드 팁과 그 주변에서의 열전달 계수 (Heat Transfer Coefficients on a Gas Turbine Blade Tip and Near Tip Regions)

  • 곽재수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.430-435
    • /
    • 2003
  • Detailed heat transfer coefficient distributions on a gas turbine blade tip were measured using a hue-detection base transient liquid crystals technique. The heat transfer coefficients on the shroud and near tip regions of the pressure and suction sides of a blade were also measured. Both plane tip and squealer tip blade were considered. The heat transfer measurements were taken at the three different tip gap clearance of 1.0%, 1.5%, and 2.5% of blade span. Results show the overall heat transfer coefficients on the tip and shroud with squealer tip blade were lower than those with plane tip blade. However, the reductions of heat transfer coefficients near the tip regions of the pressure and suction sides were not remarkable.

  • PDF

이젝터가 부착된 냉동시스템의 성능실험

  • 이원희;김윤조;김민수
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.993-1001
    • /
    • 2001
  • Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out. In this study, a hydrofluorocarbon (HFC) refrigerant R134a is chosen as a working fluid. The condenser and two-evaporators are made as concentric double pipes with counter-flow type heat exchangers. Experiments were performed by changing the inlet and outlet temperatures of secondary fluids entering condenser, high-pressure evaporator and low-pressure evaporator at test conditions keeping a constant compressor speed. When the external conditions (inlet temperatures of secondary fluid entering condenser and one evaporator) are fixed, results show that coefficient of performance (COP) increases as the inlet temperature of the other evaporator rises. It is also shown that the COP decreases as the mass flaw rate ratio of suction fluid to motive fluid increases. The COP of dual-evaporator refrigeration system with an ejector is superior to that of a single-evaporator vapor compression system by 3 to 6%.

  • PDF

Experimental Study on the Performance of Refrigeration System with an Ejector

  • Lee, Won-Hee;Kim, Yoon-Jo;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권4호
    • /
    • pp.201-210
    • /
    • 2002
  • Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out. In this study, a hydrofluorocarbon (HFC) refrigerant R134a is chosen as a working fluid. The condenser and two-evaporators are made as concentric double pipes with counter-flow type heat exchangers. Experiments were peformed by changing the inlet and outlet temperatures of secondary fluids entering condenser, high-pressure evaporator and low-pressure evaporator at test conditions keeping a constant compressor speed. When the external conditions (inlet temperatures of secondary fluid entering condenser and one of the evaporators) are fixed, results show that coefficient of performance (COP) increases as the inlet temperature of the other evaporator rises. It is also shown that the COP decreases as the mass flow rate ratio of suction fluid to motive fluid increases. The COP of dual-evapo-rator refrigeration system with an ejector is superior to that of a single-evaporator vapor compression system by 3 to 6%.

5축 Machining Center를 이용한 임펠러 가공을 위한 공구경로 생성에 관한 연구 (A Study on Tool Path Generation for Machining Impellers with 5-Axis Machining Center)

  • 장동규;조환영;이희관;공영식;양균의
    • 한국정밀공학회지
    • /
    • 제21권3호
    • /
    • pp.83-90
    • /
    • 2004
  • This paper proposes a tool path generation method for machining impellers with 5-axis machining center. The shape of impeller is complex, being composed of pressure surface, suction surface and leading edge, and so on. The compound surface which is made of ruled surface such as pressure surface and suction surface and leading edge such as fillet surface, makes the tool path generation much complicated. To achieve efficient roughing, cutting area is divided into two region and then tool radius of maximum size that do not cause tool intereference is selected for shortening machining time. In finishing, accuracy is improved using side cutting for blade surface and point milling for leading edge.

Analysis of cavity expansion and contraction in unsaturated residual soils

  • Lukosea, Alpha;Thiyyakkandi, Sudheesh
    • Geomechanics and Engineering
    • /
    • 제28권4호
    • /
    • pp.405-419
    • /
    • 2022
  • Cavity expansion and contraction solutions for cylindrical and spherical cavities in unsaturated residual soils are presented in this paper. Varying soil state in the plastic zone is accounted by a numerical approach, wherein an element-by-element discretization of the plastic zone of both expanding and contracting cavities is carried out. Unlike existing methods utilizing self-similarity technique, the solution procedure enables the prediction of entire soil-state at any stage of expansion and subsequent contraction. It is also applicable for both cavity creation and expansion problems. The approach adopts constant contribution of suction to effective stress (constant Xs drainage condition) for analysis. The analysis procedure is validated by interpreting the previously reported pressuremeter test results in lateritic residual soil. The typical cavity expansion and contraction characteristics of unsaturated Indian lateritic soil were then examined using this solution procedure. The effect of initial soil-state on cavity limit pressure, plastic radius, reverse yield pressure, and reverse plastic radius are also presented.

Fat Harvest Using a Closed-Suction Drain

  • Amin, Kavit;Zakeri, Roxana;Mallucci, Patrick
    • Archives of Plastic Surgery
    • /
    • 제43권3호
    • /
    • pp.288-290
    • /
    • 2016
  • We propose a safe, simple, and novel method to harvest fat using a standard liposuction cannula and a Redivac or alternative closed-suction drain. The authors have used this technique for both 'dry' and 'wet' liposuction. This technique is both easy to perform and cost-effective whilst providing both a silent and relatively atraumatic fat harvest. The lower negative pressure compared with traditional harvesting systems likely preserves fat integrity for lipofilling. This method maximises resources already held within a hospital environment.

횡류팬을 적용한 진공청소기 흡입노즐내 유동 소음 저감에 관한 연구 (Reduction of Flow-Induced Noise in Suction Nozzle of a Vacuum Cleaner by Adopting a Cross-Flow Fan)

  • 박이선;손채훈;이성철;오장근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.935-938
    • /
    • 2007
  • In suction nozzle of a vacuum cleaner, where flow-induced noise is generated mainly by flow resistance, several ideas to reduce noise are investigated. To increase fan performance, blade number is optimized and a centrifugal fan is replaced by a cross-flow fan, In addition, gear ratio of fan to drum brush is changed. It is found that fan performance is increased by adopting these methods. Next, the blade height of the fan is decreased to reduce sound pressure level, which causes inevitably decrease in fan performance. Eventually, flow-induced noise is reduced by 6.3 dBA in its overall level with the fan performance maintained.

  • PDF

터보펌프용 전진익형 인듀서에 대한 연구 (Study on the Forward-sweep Inducer for Turbopumps)

  • 김진선;홍순삼;김진한;최창호
    • 한국유체기계학회 논문집
    • /
    • 제9권2호
    • /
    • pp.25-29
    • /
    • 2006
  • Computational and experimental studies on the forward-sweep inducer for the rocket-engine turbopump are presented in comparison with the conventional backward-sweep inducer. Computational results show that back flows at the inlet decrease in the case of forward-sweep inducers compared to the back-ward inducer. Moreover, the low pressure region at the back flow is decreased, which is presumed to improve the suction performance of the inducers. Experimental results show that the suction performance of the forward-sweep inducer is almost the same as that of the backward-sweep inducer although it has smaller inlet tip diameter and shorter length. The efficiency of the forward-type inducer is found better than that of the backward-sweep inducer due to the small size of back flows.

불포화토의 투수특성 (Characteristics of Permeability for an Unsaturated Soil)

  • 송창섭;신창섭
    • 한국농공학회논문집
    • /
    • 제47권4호
    • /
    • pp.35-41
    • /
    • 2005
  • In order to analyse the flow problems for an unsaturated soil, it is required to examine closely the characteristics of the coefficient of permeability which is changing with the matric suction. To this ends, a permeability test was conducted on the three samples;granular soil, cohesive soil and silty soil. The specimen was made by pressing the static pressure on the mold filled with soil and the void ratio was controled with the different compaction ratio. And the test was performed by using the modified apparatus of the steady state method which was proposed by flute (1972). The range of matric suction was 0-90 kPa. The measured results for the coefficients of permeability were analysed with the void ratio and the compaction ratio, and it was examined closely the characteristics of the permeability for an unsaturated soil.

양쪽 흡입 원심펌프의 성능해석에 대한 연구 (A Study of Performance Analysis for a Double-Suction Centrifugal Pump)

  • 정경남;박편구;조현준;이상구
    • 한국유체기계학회 논문집
    • /
    • 제4권4호
    • /
    • pp.7-15
    • /
    • 2001
  • Flow analysis was carried out for a double-suction centrifugal pump. Impeller-only models and a full pump model were used to simulate the velocity field and the pressure field of the pump. Heads and efficiencies were calculated with flow rates in order to obtain general performance of the pump. The calculation results were compared to the experimental data, and satisfactory results were obtained. Thus, it may be said that the CFD serves as a useful tool for pump designs.

  • PDF