• Title/Summary/Keyword: Successive residual method

Search Result 25, Processing Time 0.018 seconds

Baleen Whale Sound Synthesis using a Modified Spectral Modeling (수정된 스펙트럴 모델링을 이용한 수염고래 소리 합성)

  • Jun, Hee-Sung;Dhar, Pranab K.;Kim, Cheol-Hong;Kim, Jong-Myon
    • The KIPS Transactions:PartB
    • /
    • v.17B no.1
    • /
    • pp.69-78
    • /
    • 2010
  • Spectral modeling synthesis (SMS) has been used as a powerful tool for musical sound modeling. This technique considers a sound as a combination of a deterministic plus a stochastic component. The deterministic component is represented by the series of sinusoids that are described by amplitude, frequency, and phase functions and the stochastic component is represented by a series of magnitude spectrum envelopes that functions as a time varying filter excited by white noise. These representations make it possible for a synthesized sound to attain all the perceptual characteristics of the original sound. However, sometimes considerable phase variations occur in the deterministic component by using the conventional SMS for the complex sound such as whale sounds when the partial frequencies in successive frames differ. This is because it utilizes the calculated phase to synthesize deterministic component of the sound. As a result, it does not provide a good spectrum matching between original and synthesized spectrum in higher frequency region. To overcome this problem, we propose a modified SMS that provides good spectrum matching of original and synthesized sound by calculating complex residual spectrum in frequency domain and utilizing original phase information to synthesize the deterministic component of the sound. Analysis and simulation results for synthesizing whale sounds suggest that the proposed method is comparable to the conventional SMS in both time and frequency domain. However, the proposed method outperforms the SMS in better spectrum matching.

Volumetric Image System for High Efficiency Video Coding (고효율 비디오코딩을 위한 입체영상시스템)

  • Kim, Sang Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.515-520
    • /
    • 2016
  • Volumetric image system has many applications recently in education, 3D movie, medical images but these applications have several problems that need to be overcome. Volumetric display may process a amount of visual data and design the high efficient vision system for realtime display. In case of stereo system for volumetric display motion vectors, disparity vectors from the stereoscopic sequences and residual images with the reference images has been transmitted, and the stereoscopic sequences have been reconstructed at the receiver for volumetric display. So central issue for the design of efficient volumetric image system lies in selecting an appropriate stereo matching and robust vision system. In this paper, we proposed high efficient vision system, which design vision stage with rotating and moving horizontally, and match the successive stereo image efficiently. In experimental results with volumetric image system, the proposed method represents high efficiency with minimizing error and low computational load for volumetric display.

Stress Analysis of Composite Plate with an Elliptical Hole or a Crack Using Complex Potentials (복소퍼텐셜을 이용한 타원공 또는 균열을 가진 복합재 평판 응력해석)

  • Kwon, Jung-Ho;Hwang, Kyung-Jung
    • Composites Research
    • /
    • v.20 no.5
    • /
    • pp.56-63
    • /
    • 2007
  • An approach using complex potentials is presented for analysis of composite plate with an elliptical hole or a rectilinear crack. Composite structure is susceptible to encounter impact damages, which lead to considerable decrease in its residual strength. Such impact damages could be modeled as an equivalent elliptical hole or notch-like crack. Even though finite element method is widely used to analyze stresses or fracture mechanics parameters around such damage, it is tedious to make successive FE-modeling for damage tolerance assessment under fatigue loadings. In this point of view, the solutions based on complex potentials are very simple and easy to use. The computed results are also compared and discussed with those from FEA.

Measure of Environmental Performance through Integrated Pollution Intensities (통합오염원단위 지수를 이용한 환경성과 측정)

  • Kang, Sang-Mok;Chung, Young-Keun;Cho, Joo-Hyun
    • Environmental and Resource Economics Review
    • /
    • v.14 no.1
    • /
    • pp.135-166
    • /
    • 2005
  • This paper measures integrated pollution intensities and changes in pollution intensity, and figure out environmental performance. We introduce a new definition of pollution intensity and its method measuring integrated pollution intensities. We distinguish 24 manufacturing industries into light industry and heavy industry, and divide heavy industry into pollution industry and the other residual heavy industry to measure the integrated pollution intensities and their changes. While the pollution industry within heavy industry, based on the integrated pollution intensity, was the most pollution-intensive, the other residual heavy industry within the heavy industry was the most successive in reducing pollutants. The annualized average index of the integrated pollution intensities grew as much as 9.1 percent, of which the annualized change in the index of pollution emission increased 13.3 percent, but the improvement of 3.9 percent in the change of output quantity offset the increase in the index of pollution emission. The changes in the integrated pollution intensity for the light and heavy industries were 1.125 and 1.042, respectively. The reason the heavy industry showed the lower change in the index of pollution intensity, while the change in the pollution industry was very high, was because the average change in the other heavy industry decreased around 9 percent.

  • PDF

Evaluation of Cellotape Anal Swabs in the Diagnosis of enterobiasis (요충층에 있어서 항문주위 도말법의 검토)

  • Kim, Jong-Seong;Choi, Hyang-Hee;Joo, Kyoung-Hwan;Rim, Han-Jong
    • Journal of agricultural medicine and community health
    • /
    • v.12 no.1
    • /
    • pp.94-101
    • /
    • 1987
  • Enterobiasis is common helminthic infections found in man. But control of this disease is still troublesome because of its difficulty in the d diagnosis and prevention of infection. Considering the difficulty of accurate diagnosis of pinworm infection, which is very common and somewhat pathogenic, reevaluation of cellotape anal swab method for the diagnosis of enterobiasis was performed. A total of 147 children ranging the ages of 1-12 years in 3 orphanages in the suburbs of Seoul, Korea was subjected for this study. Repeated cellotape anal swabs were carried out against 70 children, 7 times for 3 days interval, in the morning 6am. Finally 10 mg/kg body weight pyrantel pamoates were given to all children including egg negative cases and whole stools of 3 following successive days were collected for the confirmation of residual worm ourden at the time of treatment. Cellotape anal swabs were also performed to another 77 children at 6am, 3pm, 9pm, twice for 3 days interval. The resultant findings were summarized as follows; 1) While the each time average detection rate of Enterobius egg was 28.8% in this study group, the accumulative detection rate up to 7th examination was 62.8%. The accumulative detection rate rose continuously up to 6th examination. 2) After administration of pyrantel pamoate 10 mg/kg body weight, final infection rate was increased to 72.9% by adding worm positive cases who didn't show any evidence of infection in the cellotape anal swabs. 3) Although pinworms were detected in 35 among 70 children treated, 7 cases (20%) of them were egg negative cases in 7 consecutive cellotape anal swabs. 4) Pinworms were expelleded in 14 (87.5%) among 16 children whose swab result was positive in the last examination which was done concurrently with drug administration. 5) Estimated infection rate calculated by best asymptotically normal estimate of Neuman from Moriya's modification revealed 71.5% similar to 72.9% of present results. 6) The result of anal swab performed at 6am was higher than that of 3pm or 8pm. In conclusion, cellotape anal swab method for Enterobius vermicularis infection was considered as method having relatively high positive accuracy. However to gain the reliable infection rate, at least 6 examination is required in the group with 25-30% infection rate by single swab. Moriya's modification of Neuman could be used efficiently in the mass control of this diease for the estimation of true infection rate of E. vermicularis in the sampled population.

  • PDF