• Title/Summary/Keyword: Subway system

Search Result 859, Processing Time 0.031 seconds

A Numerical Study on the Smoke Control in Center-Platform Type Subway Station Fires (섬식 지하철역사내 화재시 연기제어에 관한 수치해석적 연구)

  • Lee, Sung-Ryong;Ryou, Hong-Sun
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.3 s.40
    • /
    • pp.313-318
    • /
    • 2007
  • In this study, numerical simulations were carried out to analyze the effect of the smoke extraction system and fire shutters in subway station fires using FDS 4.0. Subway station used in the experiment was 145 m long. Simulation results are validated by comparing with experimental results. Simulation results showed good agreement with experimental results within $10^{\circ}C$. 10 MW polystyrene was used as a fuel in the numerical prediction. Numerical predictions were performed in the center-platform type subway station in case of a kiosk fire. Temperature and CO concentration were lowered by the operation of smoke extraction system. But, the operation of fire shutters had little effect on temperature and CO concentration in the platform level.

A study on Whole Body Vibration in Subway System (지하철 전동차에서의 전신진동 특성에 관한 연구)

  • Jeong, Sang Wook;Park, Sang Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.1
    • /
    • pp.87-98
    • /
    • 1997
  • In this study, subway train vibration has been measured to characterize the whole body vibration of Seoul subway lines for various human postures. Results show that the floor vibration level of the subway trains in the vertical direction is higher than that in other directions. At the standing human posture, vibration level of the head in the right-left direction are increased while that in the vertical direction is decreased. It is assumed that the different flexibility of the human body and the rolling motion of the subway trains are the main cause. At the sitting posture with back seat on, vibration level in the right and left direction at the human ischial tuberosities is lower than that in other directions. Results also show that there were little difference between back-seat on model and back-seat off model. Transmissibility analysis shows how the subway vibration affects the response of a human body.

  • PDF

A Case study on the plan for the ESC integrating optimized train operation system for Fire & power failure accident in subway (도시철도 화재$\cdot$단전시 최적 열차운행을 위한 통합운영체계 구축방안에 관한 연구)

  • Kim Young-Wook;Choi Se-Wan;Kim Young-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1185-1192
    • /
    • 2004
  • Recently heavy traffic is getting worse because increasing population of transportation in urban area. In order to solve this problem. subway is realized with high speed, high density, highly efficiency. When fire accident happened in Dae-Gu subway in February 2003, there happened loss of people and lots of damage because of not being able to control even though fire alarm which was set up in the station rang. This thesis has constructed a simulation integrating operation system using a Database construction, operating program analysis in order to build up the most efficient train operation system. The result of simulation integrating operation system with emergency virtual situation like station and train fire, train failure, power line failure, all trains running on the rail were secured safety by train operation control system. With integrating operation of each train control system, train system, power system, machine facility system, the most efficient integrating operation system should have been constructed at the time the subway fire and power failure broke out.

  • PDF

Determination of Source Contribution Based on Aerosol Number and Mass Concentration in the Seoul Subway Stations (분진의 개수농도 및 질량농도에 입각한 서울시 지하철 역사 내 오염원의 기여도 결정)

  • 최형욱;황인조;김신도;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.1
    • /
    • pp.17-31
    • /
    • 2004
  • The subway play an important part in serious traffic problems. However, because subway system is a closed environment, many serious air pollution problems occurred in subway stations and injured passenger's health. Therefor, it is a necessary to identify sources and to estimate pollutant sources in order to protect passenger's health and to keep clean subway environment. The purpose of this study was to analyze a air quality in the subway stations and to apply a new receptor methodology for quantitatively estimate of PM10 sources. In this study, the size distributions of particulate matters has been measured by using Aerosizer LD (U.S.A., API, Inc.). It's real time measurement capability of time-of-flight technique offers a significant advantage of user convenience and air pollution management. Also, the mass concentrations of PM 10 has been measured by using mini-vol portable sampler (U.S.A., Airmetrics Co.). The sampling performed in Seoul subway stations during the period of February 2000 and April 2000. The number distribution data used in this study consisted of 26 raw data sets in the Jongno-sam-ga station. Correlation Analysis can be used in subway stations for source separation and identification. Then, number contribution from each source is determined by the particle number balance (PNB). The mass concentration data used in this study consisted of 31 raw data in the 8 different stations. The mass contributions of PM10 sources in the concourse by using PMF/CMB model.

Visual Performance Evaluation Study of Wayfinding Factors in Subway Transfer Station - Focus on the Sadang Subway Station, Seoul Subway Station, Jongro3-ga Subway Station and Gongduck Subway Station - (지하철 환승공간에서 경로탐색(wayfinding)을 위한 시환경 지각 요소에 관한 연구 - 지하철 사당역, 서울역, 종로3가역, 공덕역을 중심으로 -)

  • Song, Hyeon-Ji;Kim, Nam-Hyo
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.4
    • /
    • pp.167-177
    • /
    • 2013
  • The environmental considerations should be taken into full consideration in order to make the use of ground space as comfort and efficient as that of ground space. The visual environmental factors which provide visual informations in underground spaces where the environmental information can be acquired only by the surroundings expand their role as affordance for wayfinding. This study focuses on the visual performance evaluation of wayfinding factors on the subway transfer station platform and aisle as major space for movement in four subway transfe stations and analyzes the material, pattern, color, and lighting provided by the visual environment in underground space as directional marked label, regional differentiation and sign system. The results of this study comes are as follows. First, As to the directional marked label at the subway platform and transfer aisle, following patterns are colors, finishing materials and lighting for the sake of safety and convenience, And regional differentiation, following colors are patterns for the space division. Finally sign system which practically provides the most information, however, it is most insufficient to be a space-preception element. Second, According to the type of platform structures, such as an island platform and a separate platform, the main areas of and necessity for the space-perception elements may bring about changes. Third, these four stations that has been analyzed for this study, lighting, compared with color, finishing material and pattern, has been highly insufficient to be a perception element.

Concentration and Properties of Particulate Matters (PM10 and PM2.5) in the Seoul Metropolitan (서울시 지하철 시스템 내의 입자상물질(PM10, PM2.5) 농도 특성)

  • Lee, Tae-Jung;Lim, Hyoji;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.2
    • /
    • pp.164-172
    • /
    • 2015
  • Seoul subway plays an important part for the public transportation service in Seoul metropolitan area. As the subway system is typically a closed environment, frequent air pollution problems occurred and passengers get malhealth impact. Especially particulate matters (PM) is well known as one of the major pollutants in subway environments. The purpose of this study was to compare the concentrations of $PM_{10}$ and $PM_{2.5}$ in the Seoul subway system and to provide fundamental data in order to management of subway system. $PM_{10}$ and $PM_{2.5}$ samples were collected in the M station platform and tunnel of Subway Line 4 in Seoul metropolitan and in an outdoor location close to it from Apr. 21, 2010~Oct. 27, 2013. The samples collected on teflon filters using $PM_{10}$ and $PM_{2.5}$ mini-volume portable samplers and PM sequential sampler. The PM contributions were $48.6{\mu}g/m^3$ (outdoor), $84.6{\mu}g/m^3$ (platform) and $204.8{\mu}g/m^3$ (tunnel) for $PM_{10}$, and $34.6{\mu}g/m^3$ (outdoor), $49.7{\mu}g/m^3$ (platform) and $83.1{\mu}g/m^3$ (tunnel) for $PM_{2.5}$. The $PM_{10}$ levels inside stations and outdoors are poorly correlated, indicating that $PM_{10}$ levels in the metro system are mainly influenced by internal sources. In this study, we compared PM concentrations before and after operation of ventilation and Electrostatic Precipitator (EP). Despite the increased PM concentration at outdoor, $PM_{10}$ concentration at platform and tunnel showed the 31.2% and 32.3% reduction efficiency after operation the reduction system. The overall results of this study suggest that the installation and operation of the ventilating system and EP should have served as one of the important components for maintaining the air quality in the subway system.

A Economic Feasibility Analysis of Energy Saving Technology Application to Underground Subway Station

  • Kim, Hyungchul;Shin, Seungkwon;Jung, Hosung;Kim, Jin-o;Cha, Junmin
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.36-40
    • /
    • 2015
  • In Korea, new total energy-saving solution has planned to build test-bed in underground subway station. Breaking energy is one of the most energy saving method in railway, but it has not be fully used up for economical purpose. This paper demonstrates on energy saving technology application including breaking energy and heating energy to underground subway station. It also offer solution of optimization of power energy flow. Moreover, economic feasibility analysis performed for undergound test bed constuction.

A study on introducing Season Ticket in Seoul metropolitan area (수도권 지하철 정기권 도입방안)

  • Kim Yeon-Kyu;Kim Chan-Sung;Seo YoungWook
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.1064-1072
    • /
    • 2005
  • Since July 1st of 2004, a transit fare system of Seoul metropolitan area has been changed. The distinguished characteristics of the system can be described as two issues that can be summarized by distance based fare for Seoul metropolitan area and fare discount between bus and transit in Seoul city area. In Seoul city area, some existing subway users, however, complained the raised fare compared to previous fare system. An alternative, season ticket was introduced by Seoul local government in July 15th of 2004. Due to the ticket, even though periodic subway users could reduce average subway costs, the benefit of the season ticket was very limited to subway users in Seoul city area. Therefore, this study proposes a methodology to enlarge the benefit of the existing season ticket in Seoul metropolitan area.

  • PDF

Analysis of Air Flow Rate through Subway Vent Shaft with Mechanical Ventilation System for Shape Change of Vent Shaft

  • Kim, Jung-Yup
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.2
    • /
    • pp.45-51
    • /
    • 2009
  • Three-dimensional numerical analyses of mechanical ventilation system in vent shaft of subway in operation are carried out in relation with the different air flow passage of vent shaft and two ventilation operation modes of push/pull, The ventilation characteristics of vent shaft with regard to the shape change are evaluated. And the air flow rate through the vent shaft by ventilation system is measured within subway in operation to assess the accuracy and applicability of the numerical analysis method. The decrease of air flow rate due to vent-shaft change are between 0.7 to 2.2% in the cases examined.

A study on the safety plan for rolling stock due to Taegu subway accident (대구 지하철사고에 따른 차량안전대책 연구)

  • Lee Kwan-Sup
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.307-311
    • /
    • 2003
  • Taegu subway fire accident happened on 18th February this year, which was recorded as the 2nd biggest subway accident in the world. The accident was inspected and reviewed by Task Force Team of MOCT and KRRI, which results in the integrated safety plan for subway system. Among the safety plan. this report describes the analysis of the accident causes and safety plan in the field of rolling stock.

  • PDF