• 제목/요약/키워드: Subway station

검색결과 629건 처리시간 0.022초

확률론적 모의실험 기법을 이용한 일부 지하철 근무자들의 이산화질소 개인노출 시나리오 분석 (Scenario Analysis of Personal Nitrogen Dioxide Exposure with Monte Carlo Simulation on Subway Station Workers in Seoul)

  • 손부순;장봉기;양원호
    • 한국환경과학회지
    • /
    • 제10권3호
    • /
    • pp.195-200
    • /
    • 2001
  • The personal exposures of nitrogen dioxide(NO$_2$), microenvironmental levels and daily time activity patterns on Seoul subway station workers were measured from February 10 to March 12, 1999. Personal NO$_2$exposure for 24 hours were 29.40$\pm$9.75 ppb. NO$_2$level of occupational environment were 27.87$\pm$7.15 ppb in office, 33.60$\pm$8.64 ppb in platform and 50.13$\pm$13.04 ppb in outdoor. Personal exposure time of subway station workers was constituted as survey results with $7.94\pm$3.00 hours in office, $2.82\pm$1.63 hours in platform and 1 hours in outdoor. With above results, personal $NO_2$exposure distributions on subway station workers in Seoul were estimated with Monte Carlo simulation which uses statistical probabilistic theory on various exposure scenario testing. Some of distributions which did not have any formal patterns were assumed as custom distribution type. Estimated personal occupational $NO_2$exposure using time weighted average (TWA) model was 31.$29\pm$5.57 ppb, which were under Annual Ambient Standard (50ppb) of Korea. Though arithmetic means of measured personal $NO_2$exposure was lower than that of occupational $NO_2$exposure estimated by TWA model, considering probability distribution type simulated, probability distribution of measured personal $NO_2$exposures for 24 hours was over ambient standard with 3.23%, which was higher than those of occupational exposure(0.02%). Further research is needed for reducing these 24 hour $NO_2$personal excess exposures besides occupational exposure on subway station workers in Seoul.

  • PDF

다중이용시설에서의 실내공기중 미생물 분포에 관한 연구 (Distribution and Classification of Indoor Concentration of Microorganisms in Public Buildings)

  • 김윤신;이은규;엽무종;김기영
    • 한국환경보건학회지
    • /
    • 제28권1호
    • /
    • pp.85-92
    • /
    • 2002
  • A measurement of indoor microorganism using Reuter Centrifugal Air Sampler(RCS) was undertaken during October 1991 - February 1999 and 6-Stage Cascade Air Sampler was undertaken during May 2001 - June 2001 in Seoul. Sites including book store, department store, theater, subway station, underground shopping center, hospital, office building, sports facility, and eduationa institutio were chosen to measure indoor microorganism. The results were as follows: 1. The average of total microorganism collected on the agar strip GK-A media were, in the order, subway station, hospital, underground shopping center, department store, book store, theater, sports facility, educational institution, office building in sites. The highest concentration of 711cfu/m$^3$ was found in the subway station and the lowest concentration of 44cfu/m$^3$ was found in office building. 2. The average of staphylococci collected on the agar strip GK-S media, in the order, were subway station, underground shopping center, hospital and department store, department store, theater, office building, sports facility and educational institution in sites. The highest concentration of 502cfu/m$^3$ was found in the subway station and the lowest concentration of 14cfu/m$^3$ was found in sports facility and educational institution. 3. The average of fungus collected on the agar strip GK-HS media, in the order, were underground hospital, shopping center, theater, subway station, department store, book store, sports facility, educational institution, and office building in sites. The highest concentration of 252cfu/m$^3$ was found in the hospital and the lowest concentration of 32cfu/m$^3$ was found in office building. 4. Ratio of Indoor/Outdoor, determined by site was 1.12-2.38 in total count, 1.00-2.35 in staphylococci, and 0.99-1.34 in fungus. 5. The positive results of test were 12-24% in indoor and 9-43% in outdoor. 6. By gram staining gram positive cocci were 59.9%, gram positive bacill 24.4%, gram negative bacilli 10.4%, and gram negative cocci 0.5%.

지하공간의 공기 질 개선을 위한 지하철 터널 내 열차풍의 수치 해석적 연구 (A NUMERICAL ANALYSIS OF TRAIN-WIND IN THE SUBWAY TUNNEL FOR THE IMPROVEMENT OF THE OF UNDERGROUND SPACE AIR QUALITY)

  • 이준호;쥬레바 막슈다;정상현;송동주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.523-528
    • /
    • 2011
  • Subway becomes more and more main transportation in major cities. Air pollution in the subway platforms is decreased; however, dust flow inside subway tunnel and train is increased by installing Platform Screen Door. Airflow inside subway tunnel is observed using computational method in this study The airflow characteristics around ventilation shafts and inside the tunnel is studied following the train movement, while the train moves from existing Miasamgeori station to Gireum station ANSYS CFX V12.0.l and ICEM CFD V12.0.l are used to compute the airflow inside the subway tunnel.

  • PDF

도시철도 건설과 역세권이 아파트가격에 미치는 영향 분석 - 대구도시철도 3호선 역세권 거리와 아파트 면적 구분을 중심으로 - (An Analysis of the Impact of Subway Construction on Apartment Price in the Station Areas: Focusing on the Daegu Subway Line 3)

  • 이규태;김은지;도수관
    • 지역연구
    • /
    • 제32권1호
    • /
    • pp.3-26
    • /
    • 2016
  • 본 연구의 목적은 최근에 개통된 대구도시철도 3호선 건설과 역세권 아파트가격 간의 관계를 이벤트 스터디(event study) 기법을 적용하여 실증적으로 분석하고, 역세권 아파트가격에 영향을 미치는 요인들을 탐색하는 데에 있다. 역세권 아파트가격의 영향요인 탐색을 위해서는 선행연구의 한계를 고려하여 아파트 면적과 역세권 거리 구분 변수를 분석모형에 포함하였다. 주요 분석 결과를 요약하면 다음과 같다. 첫째, 대구도시철도 3호선 건설 착공시작시점보다 공사완료시점에서 역세권 아파트가격 상승이 더 크게 나타났다. 둘째, 대구도시철도 3호선 개통으로 인한 접근성 향상이 아파트가격 상승에 긍정적인 영향을 미치고 있는 것으로 나타났으며, 특히 역 반경 200~600m 이내의 아파트가격 상승이 가장 높은 것으로 나타났다. 셋째, 아파트 면적별로는 중대형 및 대형 아파트가격이 소형 아파트가격에 비해 상대적으로 대구도시철도 3호선 건설에 더 민감하게 반응하였음을 확인할 수 있었다. 넷째, 자치구별로는 북구와 수성구 지역의 아파트들이 가격 측면에서 대구도시철도 3호선 개통으로 보다 많은 혜택을 누리고 있는 것으로 나타났다. 본 연구의 이와 같은 분석결과는 향후 도시철도 건설에 따른 개발이익에 대한 과세, 피해부담집단에 대한 재분배정책 등에 관한 중요한 정책적 시사점을 제공해주고 있다.

면목역 만남의 광장 설계 (The Meeting Plaza Design around "Myeonmok" Subway Station, Seoul)

  • 김성균
    • 한국조경학회지
    • /
    • 제35권1호
    • /
    • pp.20-27
    • /
    • 2007
  • This paper presents a landscape design for the meeting plaza around the "Myeonmok" subway station. The site is located at 120-1 Myeonmok 1-dong, Jnngrang-gu, Seoul, and its area is approximately $2,664.7m^2$. The goal of the design was to make an environmentally friendly meeting and rest place which was related to the subway station. To achieve this goal, concepts of history, tradition, sense of place, community, environmental friendliness, and function were developed. For history, stone sculpture and art tiles symbolizing the paleolithic area were introduced because the site is located near an archaeological site of paleolithic min. For tradition, considering that the site is a 'sailing ship' form in terms of Pungsu theory, a sculpture symbolizing a sailing ship and paving patterns symbolizing waves were introduced. For asense of place, a grass hill, a waterfall and a pond symbolizing an old meadow for horse pasture was introduced. In addition, a multi-purpose round plaza as a meeting place for local community and subway users was proposed. A zelkova grove symbolizing a village forest was proposed for a restand relaxation area. All areas were designed to be environmentally friendly and barrier-free. Concepts for a defensible space wereadapted for safety because the site was a crime-prone area.

서울시 일부 지하철역 내 부유 진균, 입자상 물질, 이산화탄소의 분포 양상 (Distribution of Airborne Fungi, Particulate Matter and Carbon Dioxide in Seoul Metropolitan Subway Stations)

  • 김기연;박재범;김치년;이경종
    • Journal of Preventive Medicine and Public Health
    • /
    • 제39권4호
    • /
    • pp.325-330
    • /
    • 2006
  • Objectives: The aims of this study were to examine the level of airborne fungi and environmental factors in Seoul metropolitan subway stations and to provide fundamental data to protect the health of subway workers and passengers. Methods: The field survey was performed from November in 2004 to February in 2005. A total 22 subway stations located at Seoul subway lines 1-4 were randomly selected. The measurement points were subway workers' activity areas (station office, bedroom, ticket office and driver's seat) and the passengers' activity areas (station precincts, inside train and platform). Air sampling for collecting airborne fungi was carried out using a one-stage cascade impactor. The PM and CO2 were measured using an electronic direct recorder and detecting tube, respectively. Results: In the activity areas of the subway workers and passengers, the mean concentrations of airborne fungi were relatively higher in the workers' bedroom and station precinct whereas the concentration of particulate matter, $PM_{10}\;and\;PM_{2.5}$, were relatively higher in the platform, inside the train and driver's seat than in the other activity areas. There was no significant difference in the concentration of airborne fungi between the underground and ground activity areas of the subway. The mean $PM_{10}\;and\;PM_{2.5}$ concentration in the platform located at underground was significantly higher than that of the ground (p<0.05). Conclusions: The levels of airborne fungi in the Seoul subway line 1-4 were not serious enough to cause respiratory disease in subway workers and passengers. This indicates that there is little correlation between airborne fungi and particulate matter.

대심도 역사의 화재강도에 따른 연기확산 영향 분석 (ANALYSIS OF SMOKE SPREAD EFFECT DUE TO THE FIRE STRENGTH IN UNDERGROUND SUBWAY-STATION)

  • 장용준;구인혁;김학범;김진호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.373-378
    • /
    • 2011
  • As the number of deeply-underground subway station(DUSS) increases, the safety measures for DUSS have been requested. In this research, Shingumho station (The line # 5, Depth: 46m) has been selected as case-study for the analysis of smoke-spread speed with the different fire strength. Field test data measured for actual fan in DUSS was applied as a condition of a simulation. The whole station was covered in this analysis and total of 4 million grids were generated for this simulation. The fire driven flow was analyzed case by case to compare the smoke-spread effect according to the fire strength. in order to enhance the efficiency of calculation, parallel processing by MPI was employed and large eddy simulation method in FDS code was adopted.

  • PDF

A new decision method for construction scheme of shallow buried subway station

  • Qiu, Daohong;Yu, Yuehao;Xue, Yiguo;Su, Maoxin;Zhou, Binghua;Gong, Huimin;Bai, Chenghao;Fu, Kang
    • Geomechanics and Engineering
    • /
    • 제30권3호
    • /
    • pp.313-324
    • /
    • 2022
  • With the development of the economy, people's utilization of underground space are also improved, and a large number of cities have begun to build subways to relieve traffic pressure. The choice of subway station construction method is crucial. If an inappropriate construction method is selected, it will not only waste costs but also cause excessive deformation that may also threaten construction safety. In this paper, a subway station construction scheme selects model based on the AHP-fuzzy comprehensive evaluation. The rationality of the model is verified using numerical simulation and monitoring measurement data. Firstly, considering the economy and safety, a comprehensive evaluation system is established by selecting several indicators. Then, the analytic hierarchy process is used to determine the weight of the evaluation index, and the dimensionless membership in the fuzzy comprehensive evaluation method is used to evaluate the advantages and disadvantages of the construction method. Finally, the method is applied to Liaoyang east road station of Qingdao metro Line 2, and the results are verified by numerical simulation and monitoring measurement data. The results show that the model is scientific, practical and applicable.

지하역사 제연모드 승객피난 성능평가 (PERFORMANCE EVALUATION OF PASSENGERS' EVACUATION FOR SMOKE-CONTROL MODES IN A SUBWAY STATION)

  • 박원희;장희철;정우성;이한수
    • 한국전산유체공학회지
    • /
    • 제13권4호
    • /
    • pp.8-12
    • /
    • 2008
  • Heat/smoke detectors are installed in most subway platforms in Korea to detect fire. Subway platform is divided by smoke-control zones for efficient smoke-control. Once the detectors detect heat or smoke, the smoke-control ventilation system in the platform and concourse is activated according to the smoke-control ventilation mode. Smoke-control mode during fires in Korean subway platforms is that the smoke zones operate by exhausting smoke while other zones in the platform and in the concourse which is the upper floor of the platform operate by supplying air or stopping any ventilation. This study is conducted to evaluate performance of passengers' evacuation for various smoke control modes in the subway station. Distribution of smoke and heat due to fire on the platform is analyzed by using Fire Dynamics Simulator(FDS V 4.06) of NIST. Various smoke-control ventilation modes and locations of fire are considered. Evacuation and movement of passengers within the platform is simulated by building EXODUS V.4.0.

Simulation 분석을 통한 지하철 역사 피난동선 설계 방안에 관한 연구 (A Study on the Design of Evacuation Route at Subway Station Using Simulation Analysis)

  • 함은구;노삼규
    • 한국방재학회 논문집
    • /
    • 제10권5호
    • /
    • pp.1-7
    • /
    • 2010
  • 지하철 역사 화재는 다수의 인명피해를 동반한 대구 지하철사고 이후 지하철 차량 내장재, 지하역사의 제연 시스템과 승객이 지상으로 탈출하기 위해 필요한 피난시간 등과 같은 기존 시스템에 대한 적정성 논란을 가져왔다. 기존의 제연설비는 화재 시배기 용량과 역사 시설구조의 복잡성으로 인한 제어방법의 한계가 따른다. 특히 지하철 역사 화재는 지중에서 지상으로 대피하는 형태로서 이는 부력으로 인한 연기의 이동방향과 피난방향이 같아지게 되므로 피난자들이 일반화재보다도 더욱 많은 연기의 영향에 노출되어져 버리는 결과가 발생한다. 본 연구에서는 하향식 피난 동선을 설계하여 피난완료시간의 단축 및 연기 층으로부터 피난자들을 격리시켜 희생자를 줄일 수 있는 방안을 제안하였다.