• Title/Summary/Keyword: Subway facilities

Search Result 223, Processing Time 0.706 seconds

A Study on Stigma Effect of Unwelcomed Facilities on Apartment Prices: A Case Study of Sang-gye Jugong Apartment Complexes in Nowon-gu, Seoul (도시 비선호시설이 주변 아파트 가격에 미치는 낙인효과에 관한 연구 - 서울 노원구 상계동 주공 7, 9, 10단지를 사례로 -)

  • Kim, Chul-Joong;Song, Myung-Gyu
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.2
    • /
    • pp.297-314
    • /
    • 2012
  • This study investigates the stigma effect of unwelcomed facilities on apartment prices through multiple regressions based on hedonic price method. The areas studied are Sang-gye Jugong 7, 9, 10 apartment complexes. The facilities analyzed are the Chang-dong Electric Subway Depot and the Do-bong Driver's License Agency. The factors studied include the environmental variable (the elapsed time since the announcement of the re-location of these facilities), the view commanding, the distance from Chang-dong Depot, the distance from Do-bong Driver's License Test Course, the distance from neighboring facilities (subway stations, schools, parks and so on), the floor and each dwelling's exclusive space. The data used are 2,822 sales which have been collected since January 1, 2006. The facts found are as follows; first, the view commanding and the distance from the unwelcomed facilities are statistically significant. second, the environmental variable, 'days' turns out to have a positive (+) and a negative (-) significant relationship with the dependent variable, 'price', in period II and period IV respectively. This implies that the stigma effect is real. third, there are significant differences in the influence on the apartment prices among the independent variables according to time. fourth, the stigma effect is estimated as 33,686,920 Korean won in the case of the apartments which have the view commanding and 30,311,844 won in the other case before the global economic crisis. This effect seems to decrease to 22,085,078 won after the crisis. These facts suggest that stigma effects could be considered as one of the benefits in the cost-benefit analysis of Chang-dong Depot re-location project to produce somewhat higher NPV or B/C ratio.

A Study on the Characteristics of the Connecting Space between Subway & Shopping Area - Focused on the Subway Station in Seoul - (지하철역과 쇼핑센터의 연계공간 구성적 특성에 관한 연구 - 서울시 소재 지하철 역사를 중심으로 -)

  • 이남규
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.2
    • /
    • pp.159-167
    • /
    • 2004
  • To realize the above concepts of underground space, several underground facilities are concentrated upon and around subway stations in harmony with underground pedestrian walkways. As a result, the reduction of transit time and pedestrian distance make it easy to get to an object. In this study, underground space is considered not just as pedestrian walkways, but as space for various activities and as a positive element in connection with its circumstances. The purpose of the study is to understand underground space's elements and develop more aesthetic and efficient design of the space to give mental composure and familiarity to users. The development of underground connection space is one of the methods to improve the quality of the whole downtown area. This paper studied the general characteristics of connection space and space improvements after spot inspections and suggested several aspects useful for substantial design as essential data for development of underground connection space.

A Study on Minimizing for Hydration Heat Cracks of a Subway Concrete Box Structure (지하철 콘크리트 BOX 구조물의 수화열에 의한 균열저감 대책 연구)

  • Kim, Eun-Kyum;Youn, Seok-Goo;Bae, Sang-Il;Jeong, Jae-Yong;Kim, Hyeon-Cheol;Heo, Jeong-Ok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.425-428
    • /
    • 2006
  • The bigger of concrete strctures by a construct technique improvement, and the increase of the cement quantity which is caused by with use of the high-strength concrete for the load-carrying-capacity and a durability cause temperature cracks by a heat of hydration. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box strucuture, the use of blended cement, the temperature of air and concrete, control joint, was considered and analysed by a three dimensional finite element method.

  • PDF

The Study of Establishment of the Architectural Guidelines of Subway Station (도시철도 정거장의 건축가이드라인 설정에 관한 연구 - 동선시뮬레이션 분석을 통한 배치 및 동선 계획을 중심으로 -)

  • Kim, A-Hyun;Kim, Young-Ook
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.14-23
    • /
    • 2008
  • Today the Seoul metro has become the most important public transportation since opening in 1974. However, planning and design of stations, transfer systems and facilities are discorded by different companies and subway lines. Therefore, there is lack of objective design guidelines to secure legibility and safety in subway space. In this context, we aim to investigate the objective design and planing guidelines in terms of people's cognition and space use pattern. Space syntax method which enables scientific analysis is utilized to examine spatial layout considering passenger's spatial behavior. The research resulted in providing objective design and planning standards.

  • PDF

A Study of Equipment Improvment method of the Expansion joint & Air Section in Rigid Trolley Bar System (AL T-Bar) (강체전차선방식(AL T-Bar)에서의 Expansion joint 및 Air Section 설비 개량방안 연구)

  • Yoo Jeung-Sang;Jang Woo Jin;Lee Byung-Song
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.523-528
    • /
    • 2003
  • AS City traffic means, the electric railway of the role is overwhelming with recognizing good merits of safety, no environment disruption and accurate destination time. Currently, Korea subway are running about 290km through eight subway lines. The latest constructed subway had been made by imperoved matherials which is going on improving. Therefore, we researched this project to keep up facilites easily, repress a leakge current and reduse install cost and repair time in changing facility at overhead Contact wire system because of arc by reforming construction plan about Expansion Joint and Air Section which is regarded as weak point when facilities are fixed and maintianed of Rigid Trolley bar System. as above we can contribute various part to making useful O.C.S(overhead contact wire system)

  • PDF

A Study on Minimizing for Hydration Heat Cracks of a Subway Concrete Box Structure (콘크리트 BOX 구조물의 수화열에 의한 온도균열제어 대책)

  • Kim, Eun-Kyum;Jeon, Chan-Ki;Jeon, Joong-Kyu;Bae, Sang-Il
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.705-708
    • /
    • 2006
  • The bigger of concrete structures by a construct technique improvement, and the increase of the cement quantity which is caused by with use of the high-strength concrete for the load-carrying-capacity and a durability cause temperature cracks by a heat of hydration. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box structure, which is located in chloride attack region, the use of blended cement, the temperature of air and concrete, was considered and analysed by a three dimensional finite element method.

  • PDF

Value Analysis of Barrier-free Facilities at Subway Stations Using CVM with a Double Bounded Dichotomous Choice Question (이중양분선택형 질문법을 이용한 CVM에 의한 지하철 역사 Barrier-free 시설의 가치분석)

  • Jung, Hun-Young;Baik, Sang-Keun;Baek, Eun-Sang
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.5
    • /
    • pp.205-216
    • /
    • 2008
  • As the aged and physically disabled people are expected to increase in the next several years, traffic demand especially for the 'mobility handicapped people' will be stronger. According to this trend, our society needs the improvement of social overhead capital for the aged and the disabled. First of all, Barrier-free of public transport facilities is urgent case. The purpose of this study is to estimate value of the Barrier-free facilities at subway stations by using Contingent Valuation Method(CVM) with Double Bounded Dichotomous Choice Question and to analyze the factor which affects the WTP(Willingness To Pay) of subway users by using Survival Analysis. As a result of this study, 'Elevators' and 'Escalators' are higher than 'Handicapped Gate Machines' and 'Ramps for Wheelchair' in the aspect of the average willingness to pay. Therefore the government is recommended to install the Barrier-free facilities for going up and down such as 'Elevators' and 'Escalators', and then supply others for just using subway, and passing such as 'Handicapped Gate Machines' and 'Ramps for Wheelchair'. Also, the average willingness to pay of 'mobility handicapped people' is higher than that of 'normal people'. It indicates that 'mobility handicapped people' value each Barrier-free facility high compared to 'normal people'.

A Study on User's Awareness of Subway Environment Shape Objects in Metropolitan Cities (광역시 지하철 환경조형물에 대한 이용자 의식분석 연구)

  • Choi, Chol-Heyong;Park, Sun-Woo;Kim, Chang-Hyun;Cho, Han-Jin
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.927-935
    • /
    • 2009
  • Environmental shape objects not only play a part as various cultural facilities but also symbolize local unique culture beyond the limit of functional role. Therefore subway environmental shape objects should be approached in terms of public installations and art and should be designed to accommodate and meet the needs of subway users appropriately. In order to find out what subway users think about environment shape objects in subway stations, the factors that can evaluate awareness and preference for environment shape objects and visual image of environment shape objects were examined and analyzed. Positive elements were shown with regard to environment shape objects a lot but it is judged that visual quality of subway environment can be deteriorated if environment shape objects do not harmonize with the characteristics of station environment.

Full-Scale Test of Smoke-Control Performance of a Subway Tunnel (지하철 본선터널 제연성능 실물 실험)

  • Park, Won-Hee;Lee, Duck-Hee;Jung, Woo-Sung
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.94-102
    • /
    • 2011
  • Hot smoke test is done in a subway tunnel. Alcohol trays of 1.0 MW and smoke generators are used for generating hot smoke. The fans equipped with the tunnel are successively run 9 min after smoke generation. It is verified how hot smoke is controlled by fans. Velocity and direction of flow, temperature and smoke density are measured and analyzed for smoke control performance of the tunnel with fans and analyzed from the fire-safety-point of view. Velocity of smoke flow is obtained by using measured velocity and temperature at the ceiling of the tunnel. The time when smoke-control flow is builded up is different for the different positions. Velocity distributions at various positions will be used for the boundaries and the comparison data in numerical simulations for evaluation on smoke-control facilities of subway tunnel.

A Study of Smoke Exhaust Facility Operation of Subway Platform with Installation of Platform Screen Door (승강장 스크린도어 설치에 따른 배연설비운영에 대한 연구)

  • Rie, Dong-Ho;Ko, Jae-Woong;Kim, Ha-Young
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.35-40
    • /
    • 2006
  • A study on fire phenomena in a subway transit mass station has been carried out as a part of disaster prevention plan at the subway station. The ventilation facilities installed in both the platform and the trackway are designed to convert into a smoke exhaust system in emergency situation, creating such an environment as necessary for evacuation. 3 dimensional Numerical Simulations based on the CFD are carried out using a simulation tool, Fire Dynamic Simulator. Additionally, four different vent modes are made and performances are compared with the original design mode and each other to find better operation of vents at both the platform and the trackway in case of fire. From the result, an vent operational characteristics under the condition of installed PSD is clarified for the effective smoke and heat removal from the platform area compared with non installed PSD.