• Title/Summary/Keyword: Subway Stations

Search Result 393, Processing Time 0.024 seconds

Numerical Prediction of the Heat and Smoke Propagations for a Passenger Train Fire in an Underground Subway Tunnel for Different Extraction Flowrate (지하철 터널 내 운행 중 객차에서 화재발생시 제연풍량에 따른 열 및 연기 확산 예측 연구)

  • Chang, Hee-Chul;Yoon, Kyung-Beom;Park, Lee-Jin;Kim, Tae-Kuk;Park, Won-Hee;Kim, Dong-Hyeon
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.250-253
    • /
    • 2007
  • The purpose of this research is focussed on the numerical predictions of the heat and smoke propagations for a passenger train fire in an underground subway tunnel for different air supply and extraction flowrates. The analysis is performed for one of the stations on subway line #5 in Seoul under the emergency operation mode for different air supply and extraction flowrates. Five different the air supply and extraction flowrates are considered for the numerical analyses. The numerical results show that the air supply and extraction flowrates affect the smoke control performance significantly by improving the smoke removal performance for the balanced control of air supply and smoke extraction and for the unbalanced control with lager smoke extraction than air supply.

  • PDF

A Study On Gateless Fare Collection System in the Subway Using RF-ID System (RF-ID 시스템을 이용한 지하철 무개찰 시스템에 대한 연구)

  • Kim, Hyun;Ryu, Hyoung-Sun;Jin, In-Su;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.729-731
    • /
    • 2000
  • RF-ID system is being used in such diverse applications as access control, highway toll collection, personnel identification, and subway system. Especially for subway system that typically see high volumes of passenger at specific times of the days. it's critical to find a way to collect fares without unnecessarily delaying passengers. In the study, we discuss the possibility of removing all ticket gate machines in stations. This paper presents the discrimination method of card group for subway station without enter and exit gates using RF-ID system.

  • PDF

DETERMINANTS OF APARTMENT RENTS IN THE SEOUL METROPOLITAN REGION: SPATIAL ECONOMETRIC APPROACHES

  • Lee, Dongsung
    • Journal of Urban Science
    • /
    • v.9 no.1
    • /
    • pp.33-40
    • /
    • 2020
  • This research aims to analyze the determinants of apartment rents in the Seoul Metropolitan area using spatial econometrics approaches. Since spatial econometrics approaches have advantages to solve limitations of ordinary multiple regression such as spatial dependence and spatial heterogeneity. This research includes structural variables such as number of rooms and baths, neighborhood variables such as number of housing units in the apartment complex, and location variables including distances to subway stations, to traditional markets, to educational institutes, and to urban services such as parks, etc. The result shows that the accessibilities to the CBD, to subcenters, to subway station, to school, and to parks contribute to apartment rent uplift and also shows different spatial variations in rent premiums by accessibility variables. In particular, apartments located south of Han river along the Lines 2, 3, 7 and 9 have the highest rent premiums due to the accessibility to the subway.

Experiments of Smoke Behavior in an Underground Subway Station (지하역사에서의 화재연기거동 실험)

  • Kim, Dong-Hyeon;Jang, Yong-Jun;Park, Won-Hee
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.1 s.38
    • /
    • pp.67-73
    • /
    • 2007
  • Experiments were carried out to investigate smoke movement in platform of a subway station which currently is in service in Pusan, the second largest city in Korea. The recently constructed underground station of the "bank type" (two platforms on both sides of track) which is the popular layout of platforms in Korea, is chosen in Pusan. The smoke generator and heater are used for simulating the smoke movement at the fire break in the platform located in the 2nd basement of the station. Video recordings were used to monitor smoke lowering. In this study, the movements of smoke in the underground station are investigated under various smoke-control operating modes. Three tests wire conducted according to its operating mode of the ventilation systems in the platform: no operation of any ventilation systems, smoke extraction mode in occurrence of fire (presently running mode) and full capacity of smoke extraction where all vents are activated in the platform. The results can be used for comparing with the numerical prediction results of fire subway stations.

Concentration Distributions and A Reduction Strategy of Airborne Radon in Seoul Metropolitan Subway Stations (서울시 지하철역내의 라돈 농도분포 및 저감대책)

  • 김동술;김윤신;김신도;신응배;김성천;유정석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.271-277
    • /
    • 1993
  • Indoor radon has been known as one of the notorious carcinogens. However, a safe environmental criterion of radon has not yet been established in Korea, The main objectives of this study were to study concentration distributions of radon, to trace radon sources in subways, and to obtain a strategy for radon reduction in Seoul metropolitan area. Radon concentrations had been extensively determined by several steps. The first step was to survey radon levels in all of 83 subway stations from October to November in 1991. The second step was to select 40 out of 83 stations and then to study seasonal variations in 1991 and 1992. The third step was to monitor radon levels by hourly-basis plans. The fourth step was to seek a radon reduction strategy by altering ventilation at Ankuk station where had the highest radon concentration during the first measurement step. Each underground floor in the station was divided into 10 sites to measure hourly radon variations. The final step of the study was to measure radon concentrations in groundwater that is one of the possible main sources radon place. The result of the various measuring approaches showed short-and long-term radon variation and indicated radon reduction schemes.

  • PDF

A Study of Successful Factor on PSD Application Technique for Manual Operation Mode(ATS) (수동운전(ATS)구간에서 PSD 적용 기술의 성공적 요인 분석연구)

  • Son, Yeong-Jin;Park, Keun-Soo;Min, Kyung-Yun
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.755-770
    • /
    • 2006
  • 1974. 8.15 SeoulMetro, beginning with the first electric railway established at six cities, so it is managing mass transportation of traffic. Especially, in case of seoul, It is managing that from one to eight lines, 286.9km, 265 stations have installed and now it is carrying about 5.5million of passengers everyday, and 2,000million passengers a year. So accident is increasing from the station every year. For this measure, SeoulMetro prepares safety fence for passengers crash but, as suicides or people who watch the accident took place, for at the bottom of passengers crash protection, PSD installing is needed. Even though, PSD is managing ATO section but, in controlling SeoulMetro, one to four lines sections are (ATS, ATC)section. Between as ATS, ATC section, ATO section, subway gate and PSD must have opened and crossed always at the time. And the interlock control corrosion protection gate, managing skills with installation, method, using in history, apply to 10rail cars one train sets, and maximum applying 224% sections of passengers congested that consideration is to be needed. So 2004, SeoulMetro improved technology and basic design of PSD at ATS section. Based on this, from 2005.4 to 2006.6, using subway 2lines per 12stations set the model installation(full type 11stations, half type 1station) After installing in case of success, it is going about to suggest that effective analysis and hereafter subject.

  • PDF

A Study on the Microbial Air Pollution of Urban Living and Indoor Environment (생활환경과 실내공기의 미생물학적 오염에 관한연구)

  • 정윤희;홍준배;장윤희
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.1-9
    • /
    • 2001
  • This study was carried out to investigate the microbial characteristics of the urban air pollution in the subway stations, streets, department stores, wholesale markets, underground shopping centers, buildings, parks, houses and apartments in the Seoul and the suburbs area. Total cell count, total mold count and the presence of opportunistic pathogens(Streptococcus pneumoniae, Klebsiella pneumoniae, Aspergillus spp., Penicillium spp.) were evaluated determine the microbial air quality. Total cell count and mold count of indoor air in the houses and apartments were 2.9$\times$10$^2$-6.3$\times$10$^2$cfu/㎥ and 60-1.8$\times$10$^2$cfu/㎥, respectively, and the department stores and wholesale markets had much lower cell count than the houses and apartments. Ground level of commercial stations were 2.6 fold higher than the general subway stations, and Apergillus spp. and Penicillium spp. which could cause the bronchus and lung diseases were detected 17 sampling site out of 45. Dust were collected from the commercial facilities and houses, and total cell and mold count of the dust were 4.3$\times$10$^3$-1.7$\times$10$^{6}$ cfu/g and 2.3$\times$10$^3$-6.5 $\times$10$^4$cfu/g, respectively. Therefore the dust might be one of the main reservoir of microorganims.

  • PDF

A Study on Indoor Air Quality Monitoring System for Subway Stations (지하역사의 공기질 감시 시스템 구성에 관한 연구)

  • Lee, Byung-Seok;Hwang, Sun-Ju;Lee, Joon-Hwa;Kim, Gyu-Sik;Kim, Jo-Chun
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.48-50
    • /
    • 2009
  • This paper presents an IAQ(Indoor Air Quality) Monitoring System using equipments for measurement of fine Particle($PM1{\sim}PM10$), $CO_2$, VOCs(Volatile Organic Compounds), temperature and humidity for IAQ monitoring of subway station which millions of people use a day. The necessity of IAQ monitoring system is getting increased for more effective subway station monitoring in line with the recent government's regulation for IAQ is reinforcing. Subway Station is an unusual case. The structure of subway station is closed and complicated. Therefore when data of equipments are transferred, transmission error can happen occasionally. To prevent transmission error, an IAQ Monitoring System is needed the appropriate position and selection of equipments or sensor module. In addition IT(Information Technology) can be utilized like "WiBro(Wireless Broadband)" and "GateWay" for facilitate movement of data and construction of IAQ monitoring system of subway station.

  • PDF