• 제목/요약/키워드: Subway Station Platforms

검색결과 40건 처리시간 0.136초

지하역사 승강장 열환경 개선을 위한 연구 (제1보: 승강장 열환경 현황 및 실측결과) (The study for thermal environment improvement at subway station platform (Part 1: Thermal environment status and actual survey results))

  • 김희률;김동규;금종수;정용현;김종열;박성출
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.976-980
    • /
    • 2008
  • Ventilation equipment performs a cental role to maintain comfort subway environment. So ventilation equipment of Busan subway first line is needed to improvement thermal environment. In this study, condition of thermal environment is presented to improve ventilation equipment at existing subway station platforms by measuring thermal environment of platforms operated ventilation equipment at 14 stations of Busan subway first line. AWS of data in comparison with the neighbouring platforms and thermal environment analysis.

  • PDF

지하역사에서의 화재연기거동 실험 (Experiments of Smoke Behavior in an Underground Subway Station)

  • 김동현;장용준;박원희
    • 한국철도학회논문집
    • /
    • 제10권1호
    • /
    • pp.67-73
    • /
    • 2007
  • Experiments were carried out to investigate smoke movement in platform of a subway station which currently is in service in Pusan, the second largest city in Korea. The recently constructed underground station of the "bank type" (two platforms on both sides of track) which is the popular layout of platforms in Korea, is chosen in Pusan. The smoke generator and heater are used for simulating the smoke movement at the fire break in the platform located in the 2nd basement of the station. Video recordings were used to monitor smoke lowering. In this study, the movements of smoke in the underground station are investigated under various smoke-control operating modes. Three tests wire conducted according to its operating mode of the ventilation systems in the platform: no operation of any ventilation systems, smoke extraction mode in occurrence of fire (presently running mode) and full capacity of smoke extraction where all vents are activated in the platform. The results can be used for comparing with the numerical prediction results of fire subway stations.

자연에너지 활용을 위한 지하철 승강장 열환경에 관한 연구 (Study on the Subway Platform Thermal Environment for using Natural Energy)

  • 김회률;김동규;금종수;정용현;박성출
    • 수산해양교육연구
    • /
    • 제21권2호
    • /
    • pp.269-277
    • /
    • 2009
  • Ventilation equipment performs a central role to maintain comfort subway environment. So ventilation equipment of Busan subway line No.1 is required to improve thermal environment. In this study, conditions of thermal environment are presented to improve ventilation equipment at existing subway station platforms by measuring thermal environment of platforms operated ventilation equipment at 14 stations of Busan subway line No.1. AWS of data in comparison with the neighbouring platforms and thermal environment analysis. Thermal environment status of subway platform analysis results are as follows. 1)Daytime platform temperature was higher than outdoor temperature, but night time platform temperature was lower than outdoor temperature. 2)Train wind had effect on improving thermal comfort in platform. 3)When outdoor temperature is below $24^{\circ}C$, inlet air is able to lower than platform temperature. 4)Considering existing ventilation system, night purge systems is useful to improving platform thermal environment.

지하철 터널부로의 열 및 연기배출에 관한 연구 (A Study of Heat and Smoke Exhaust to Subway Tunnel Direction)

  • 이동호
    • 한국안전학회지
    • /
    • 제19권3호
    • /
    • pp.1-8
    • /
    • 2004
  • This study aims to derive the operation method of a comprehensive ventilation system which is capable of providing passengers with safe exit paths from platforms in onboard fire situations. To accomplish this, the airflow distributions in subway platforms under 6 types of tunnel vent system were calculated in addition to having analyzed diffusion behaviors of smoke and heat exhaust in such states by performing 6 kinds of different ventilation scenarios in a 3-D Fire Dynamic Simulation (FDS) simulation model. In order to recommend the mechanical smoke exhaust operation mode, Subway Environmental Simulation(SES) is used to predict the airflow of the inlet and outlet tunnel for the subway station to clarify the safety evaluation fir the heat and smoke exhaust on subway fire events.

지하역사 제연모드 승객피난 성능평가 (PERFORMANCE EVALUATION OF PASSENGERS' EVACUATION FOR SMOKE-CONTROL MODES IN A SUBWAY STATION)

  • 박원희;장희철;정우성;이한수
    • 한국전산유체공학회지
    • /
    • 제13권4호
    • /
    • pp.8-12
    • /
    • 2008
  • Heat/smoke detectors are installed in most subway platforms in Korea to detect fire. Subway platform is divided by smoke-control zones for efficient smoke-control. Once the detectors detect heat or smoke, the smoke-control ventilation system in the platform and concourse is activated according to the smoke-control ventilation mode. Smoke-control mode during fires in Korean subway platforms is that the smoke zones operate by exhausting smoke while other zones in the platform and in the concourse which is the upper floor of the platform operate by supplying air or stopping any ventilation. This study is conducted to evaluate performance of passengers' evacuation for various smoke control modes in the subway station. Distribution of smoke and heat due to fire on the platform is analyzed by using Fire Dynamics Simulator(FDS V 4.06) of NIST. Various smoke-control ventilation modes and locations of fire are considered. Evacuation and movement of passengers within the platform is simulated by building EXODUS V.4.0.

전산열유체 해석결과를 이용한 지하역사 제연모드 승객피난 성능평가 (Performance Evaluation of Passengers' Evacuation for Smoke-Control Modes in a Subway Station Based on CFD Results)

  • 박원희;장용준;이한수;장희철;이덕희
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.276-279
    • /
    • 2008
  • Heat/smoke detectors are installed in most subway platforms in Korea to detect fire. Subway platform is divided by smoke-control zones for efficient smoke-control. Once the detectors detect heat or smoke, the smoke-control ventilation system in the platform and concourse is activated according to the smoke-control ventilation mode. Smoke-control mode during fires in Korean subway platforms is that the smoke zones operate by exhausting smoke while other zones in the platform and in the concourse which is the upper floor of the platform operate by supplying air or stopping any ventilation. This study is conducted to evaluate performance of passengers' evacuation for various smoke control modes in the subway station. Distribution of smoke and heat due to fire on the platform is analyzed by using Fire Dynamics Simulator(FDS V 4.06) of NIST. Various smoke-control ventilation modes and locations of fire are considered. Evacuation and movement of passengers within the platform is simulated by buildingEXODUS V 4.0.

  • PDF

부산광역시 지하공간의 CO 대기질 평가 (The Evaluation of CO Concentration Level at Underground Space in Busan Metropolitan City)

  • 이화운;박종길;장난심;이희령;김희만
    • 한국환경과학회지
    • /
    • 제12권1호
    • /
    • pp.35-40
    • /
    • 2003
  • With increasing population densities in cities, underground facilities and entertainment locations are proliferating at a rapid pace in efforts to maximize the use of land. The purpose of this study is to evaluate CO concentration level of subway stations having underground platforms in Busan Metropolitan City, from September to November 2000, over seven times. The places of inquiry include Yonsan-dong station, Somyon station, Busan station, Nampo-dong station and Dusil station. The samplings were conducted at three points of each station, i.e. gates, ticket gates, and platforms. The component of CO concentration is the main elements of indoor air quality evaluation. The total concentrations and average concentrations of CO were the higher at the Somyon station. The distribution of CO concentrations at each station, generally was higher at gate than ticket gates and platforms. The I/O ratios(I-platforms, 0-gates) were expressed highly than 1 at the Yonsan-dong station, Busan station, Nampo-dong station and were lower than 1 at the others.

전철 고상홈 승강장안전시스템 개발시험 (A Study of Safety System for High Platform)

  • 김명룡;권성태;박우현;홍용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.416-421
    • /
    • 2001
  • The subway station platform is designed in high platform for quick getting in/out which is against ordinary train platform. Out of 370 Metropolitan subway station platforms, subway stations which have cured platform are about 38%. In these cases, as the distance between subway and platform would become longer, handicapped people's wheelchairs, baby carriers and old and feeble people can feel uncomfortable when they are getting in and out Also, passengers often fall into track because of the height difference between high platform and track. And if passengers go down on track to pick up something fallen, they sometime fail to climb up and happen to hit against subway. To solve out these kind of inconveniences and prevent accidents, we have developed subway station high platform safety system and finished tests. This safety system is consisted of safety block, screened door and safety wall. This study explained the composition and function of this system and presented the test result to identify its performance.

  • PDF

지하역사 승강장 열환경 개선을 위한 연구 (제2보: 도입외기온도에 따른 승강장 열환경) (The study for thermal environment improvement at subway station platform (Part 2: Thermal environment according to supply outdoor temperature))

  • 김회률;김동규;금종수;정용현;김종열;김민수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.561-564
    • /
    • 2009
  • This study is to examine the possibility of pre-cooling at platform. Through measurement of the thermal environment of Bujeon Subway platforms, review the potential use of ground-water and night purge. The results of this research can improve the thermal environment pre-cooling of the design.

  • PDF

모바일 환경센서 모듈을 이용한 지하철 2호선의 공기질 분석 (Air Quality Analysis of Subway Station Line Number 2 Using Mobile Environmental Sensor Modules)

  • 나형욱;김창훈;김규식;김희식;김조천
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.354-356
    • /
    • 2009
  • Air quality analysis is done for subway trains and subway platforms of subway line number 2 using mobile environmental sensor modules. $CO_2$ and PM10/PM2.5 particulate concentration are investigated for screen door systems, under-ground platforms, and transfer stations. These results would help to increase the quality of life of subway railroad passengers.

  • PDF