• 제목/요약/키워드: Subsurface zone

검색결과 161건 처리시간 0.023초

점적관개에서 관개율이 Sandy Loam토양의 습윤양상에 미치는 영향 (Effects of the irrigation Rate on Wetted Patterns in Sandy Loam Soil Under Trickle irrigation Condition)

  • 김철수;이근후
    • 한국농공학회지
    • /
    • 제31권2호
    • /
    • pp.104-115
    • /
    • 1989
  • In an effort to clarify the wetted patterns of sandy loam soil under trickle irrigation conditions, the distance of wetted zone, infiltration capacity and soil wetted patterns, etc. were measured by gypsum block as soil moisture sensor located every 5 cm vertically and horizontaly in the soil bin under the such conditions as a). irrigation rates set to 2, 4, 6, 8 liters per hour b). total amount of water applied fixed to 14.62 liters per soil bin c) the hearing force of soil measured by plate penetrometer ranging from 1.04 to 1.22kg/cm$_2$ The results can be summarized as follows ; 1. The wetted distance in horizontal direction(H), the wetted distance in vertical direction(D), the horizontal infiltration capacity (iH) and the vertical infiltration capacity(in)could by explained as a function of time t. 2. The horizontal wetted distance (H) is explained by an exponetial function H= a$.$ t where b was found ranging from 021 to 026 under surface trickle irrigation, which was considered a lotlower than the classical value of 0.5 and these measurements were indifferent to the increasing irrigation rates. 3. As for the surface trickle irrigation where horizontal infiltration capacity(iH) is explained as iH = A $.$ t h, the coefficient A increases with respect to irrigation rates within the limits of 0.89~1.34. 4. In terms of surface trickle irrigation of the ratio of Dm Which is maximum vertical wetted distance to Hm, which is maximum horizontal wetted distance, found to be within range of 1.0 to 1.21. It was also noted that the value of Dm decreses when irrigation rates increases while the value of Hm changes the opposite direction. 5. The optimum location of sensors from emitter for surface trickle irrigation should he inside of hemisphere whose lateral radius is 28~30cm long and vertical radius is 10~12cm long. The distance between emitters should be within 60cm long. 6. In the study of vertical wetted distance( D) where D= a $.$ tb, the exponential coefficient b ranged from 0.61 to 0.75 in surface trickle irrigation, and from 0A9 to 0.68 for subsurface trickle irrigation. These measurements showed an increasing tendency to with respect to irrigation rates. 7. In case of vertical infiltration capacity( in), where iD= A $.$ t 1-h, the coefficient A for surface trickle irrigation found to be within range of 0.16 to 0.19 and did not show any relationships with varying degree of irrigation rates. However, the coefficient was varying from 0.09 to 0.22 and showed a tendency to increase vis-a-vis irrigation rates for subsurface trickle irrigation, in contrast. 8. In the observation of subsurface trickle irrigation, it was found that Dm/Hm ratio was within 1.52 to 1.91 and showed a decreasing tendency with respect to increasing rates of irrigation. 9. The location of sensors for subsurface trickle irrigation follows same pattern as above, with vertical distance from emitter being 10~17cm long and horizontal 22~25cm long. The location of emitter should be 50 cm. 10.The relationship between VS which is the volume of wetted soil and Q which is the total amount of water when soil is reached field capacity could be explained as VS= 2.914Q0.91and the irrigation rates showed no impacts on the above relationship.

  • PDF

시설풋고추 재배에서의 지중관수 및 공기주입 효과 (Effects of Subsurface Drip Irrigation and Aeration in Green Pepper Cultivation)

  • 권준국;강남준;조명환;강윤임;박경섭;이재한
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.225-231
    • /
    • 2009
  • 지표관수와 비교하여 지중관수 및 지중관수 시 공기주입의 효과를 검토하고자 '녹광' 풋고추를 온실 내에서 토양재배(silty loam)하여 관수효율, 토양특성, 과실 생육 및 수량 등을 조사하였다. 관수방법은 관수호스를 이랑당 2열 배열하되 지표관수는 토양표면, 지중관수는 지표 20cm 아래에 설치하였고, 공기주입은 air compressor를 이용하여 낮 동안에 시간당 3분간 주입하였다. 관수는 콘트롤러, 전자식 토양수분장력센서 등을 이용, 토양수분에 기초한 자동관수를 실시하였는데, 관수개시점은 -20kPa, 관수종료점을 -10kPa로 설정하여 관리하였다. 그 결과, 토양수분의 감소속도가 지표 관수에 비해 지중관수와 지중관수 +공기주입이 늦었으며, 관수량도 지중관수가 지표환수에 비해 지표면에서의 증발 감소 등으로 약 30% 적었다. 표토층의 EC 및 무기이온함량은 지표관수에 비해 지중관수나 지중관수 +공기주입이 낮은 수준이었다. 뿌리의 발달은 지표관수에 비해 지중관수+공기주입한 것이 가장 좋았는데, 특히 뿌리가 길고 세근의 발달이 많았다. 이로 인해 풋고추 수량이 지표관수에 비해 지중관수가 22%, 지중관수 +공기주입이 30% 각각 증가되었다.

연직배수재를 이용한 오염도턍복원 특성 평가 (Evaluation of Remediation of Contaminated Soil Using PVDs)

  • 신은철;박정준;노정민
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1400-1407
    • /
    • 2005
  • There are a number of approaches to in situ remediation that are used at contaminated sites for removing contaminants from the contaminated zone without excavating the soil. These include soil flushing, dual phase extraction, and soil vapor extraction. Of these techniques, soil flushing is the focus of the investigation in this paper. The concept of using prefabricated vertical drains(PVDs) for remediation of contaminated sites with fine-grained soils is examined. The PVD system is used to shorten the drainage path or the groundwater flow and promote subsurface liquid movement expediting the soil flushing process. The use of PVDs in the current state of practice has been limited to soil improvement. The use of PVDs under vacuum conditions is investigated using sample soil consisting of silty sand.

  • PDF

유리침윤 알루미나 및 스핀넬 복합체에 관한 연구 I. 미세구조 및 유리함량이 접촉손상 및 강동에 미치는 영향 (A Study on Glass-Infiltrated Alumina and Spinel Composite I. Effect of Microstructure and Glass Content on Contant Damage and Strength)

  • 정연길;최성철
    • 한국세라믹학회지
    • /
    • 제35권7호
    • /
    • pp.671-678
    • /
    • 1998
  • Hertzian indentation tests with sphere indenters were used to study the mechanical properties of glass-in-filtrated alumina and spinel composites and evaluated the effect of preform microstructure and evaluated the effect of preform microstructure and glass con-tents on contanct damage and strength. The spinel composite showed more brittle behavior than the alumina composite which is verified from indentation stress-strain curve cone cracks and quasi-plastic deformation developed at subsurface. Failure originated from either cone cracks(brittle mode) or deformation zone(quasi-plastic mode) above critical load for cracking(Pc) and yield ({{{{ {P }_{Y } }}) with the brittle mode more dominant in the spinels and the quasi-plastic mode more dominant in the aluminas. Even though brittle mode was dominant in the spinel composites the strength degradation from accumulation of damage above these critical loads was conspicuously small suggesting that the glass-infiltrated composites should be highly damage tolerant to the blunt contacts.

  • PDF

자연 구릉지에서 지표하 흐름의 수치해석 (Numerical Analysis of Subsurface Flow in a Hillslope)

  • 최은호;남선우
    • 물과 미래
    • /
    • 제24권1호
    • /
    • pp.109-117
    • /
    • 1991
  • 포화-비포화 영역에서 transient흐름 해석을 위해 유체의 연속방정식과 Darcy 법칙으로부터 다공질 매체에서의 흐름 지배방정식을 유도하였다. 수치해는 가중잔차원리에 입각한 Galerkin 유한요소법으로 구하며, 시간도함수항에는 유한차분법을 적용하였다. 해석에서는 실제 자연상태에서 발생되는 부정호우자료를 이용하고 이때의 지표하 흐름 해석에 필요한 강우 주상도는 제 손실성분을 고려한 초과우량 추정모형으로부터 얻었다. 비포화 토양에서의 흐름을 고려하기 위해 투수계수, 압력수두 및 체적함수비의 상호 함수관계를 이용하였다. 모형은 대칭인 2차원으로서 비등방성, 이질 토층으로 구성하였다.

  • PDF

경기도 인천지역 분포하는 화산암류에 대한 중력 및 자력 탐사 연구 (Gravity and Magnetic Surverys for Volcanic Rocks in Yeoncheon Area, kyonggi-do)

  • 박혁진
    • 자원환경지질
    • /
    • 제32권6호
    • /
    • pp.645-651
    • /
    • 1999
  • The gravity and magnetic measurements have been obtained from 34 stations with 50m intervals along the survey line positioned between Jangtanri and sindapri for studying subsurface geology and structures of the volcanic rocks in Yeoncheon area. The Bouguer gravity and magnetic anomaly values were evaluated from the reduction of the field observation, and then interpreted by Nettleton's method and maximum-pepth rules, are approximately 160m based on magnetic data and 135m based on gravity data. High Bouguer gravity anomaly zone between 0m in Jangtanri and 900m along the survery line, is caused by thick and high density, older dasalt which is positioned beneath jijangbong tuff breccia, and this result corresponds to the interpretation result based on magnetic anomly. Lower gravity and magnetic anomaly zones ariund 900m are caused by between 1300m and 1550m are caused by high density of Quarternary basalt exposed in the surface, and lower gravity and magnetic anomalies at 200m and 1250m are caused by faults.

  • PDF

토양속의 LAPLs 제거기슬에서의 Pore와 입도분포의 응용에 관한 연구 (APPLICATIONS OF PORE AND GRAIN-SIZE DISTRIBUTIONIN RECOVERY OF LNAPLS IN SOILS)

  • Lee, Kwang-Y.
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1992년도 폐기물 매립지의 공학적 특성과 개량기술
    • /
    • pp.19-32
    • /
    • 1992
  • Objectives of this study are : 1) to utilize capillary theory and obtain pore-size distribution profiles from moisture-suction relationships using Laplace theory. 2) to investigate the behavior of Light Non-Aqueous Phase Liquids(LNAPLs) in the subsurface environment and to develop several predictive relationships which can be used to assess the effectiveness of various LNAPLs remediation technologies. The relationship to predict pore-size distribution function expressed in differencial equation is found by using capillary theory. Also, experiments are conducted to : the various LNAPLs subjected to vadose zone drainage, groundwater table drainage, waterflooding with surfactants. The experiments are performed with #2 heating oil, jet fuel. and kerosene. Several relationships have been derived describing the effect of various properties and process parameters on the LNAPL residual saturation.

  • PDF

변형 쌍극자배열법을 적용한 울릉도 나리 칼데라 주변 조면안산암 지역의 비저항분포 특성 분석 (Distribution of Resistivity Zones Near Nari Caldera, Ulleung-do, Korea, Inferred from Modified Dipole Arrays)

  • 김기범;김만일
    • 지질공학
    • /
    • 제29권3호
    • /
    • pp.223-236
    • /
    • 2019
  • 전기비저항탐사는 지질 분포나 단층 파쇄대의 유무 등의 지질 구조, 지층의 풍화 및 변질 정도, 지하수 등을 파악하기 위하여 광범위하게 활용되는 탐사기법이다. 본 연구에서는 지하 전기비저항의 분포특성을 분석하기 위하여 총 6개 측선을 중심으로 울릉도 나리분지와 알봉분지 주변 지하 칼데라 퇴적층과 지질 구조를 파악하기 위하여 기존의 쌍극자배열법(A 방법과 C 방법)의 탐사결과와 함께 변형된 쌍극자배열법(D 방법)을 적용하여 연구를 수행하였다. 본 연구결과, 변형된 쌍극자배열법을 적용하여 최적의 지하 비저항 분포단면 분석을 통해 퇴적층과 연약대가 분포하는 구간인 500 ohm-m 이하의 저비저항대와 화산암체인 조면안산암질 암류가 분포하는 5,000 ohm-m 이상의 고비저항대의 경계를 명확하게 파악할 수 있었다. 알봉분지의 퇴적층은 평균 50~100m 내외, 나리분지의 퇴적층은 평균 약 100~200m 내외의 두께로 분포하는 것으로 추정되며, 칼데라 단층으로 추정되는 이상대는 지표부근에서 탐사심도 하부까지 500 ohm-m 이하의 저비저항대가 수직으로 연장성을 가지면서 암반 내 연약대와 구분되는 것으로 분석되었다.

석회석 광산 지역의 지반침하 원인 규명을 위한 현장조사와 지반 안정성 분석 사례 (A Case Study of Site Investigation and Ground Stability Analysis for Diagnosis of Subsidence Occurrence in Limestone Mine)

  • 이승중;김병렬;최성웅;오석훈
    • 터널과지하공간
    • /
    • 제25권4호
    • /
    • pp.332-340
    • /
    • 2015
  • 광산지역에서 발생하는 지반침하는 인명과 지표시설물에 막대한 피해를 초래할 우려가 있으므로 지반침하 발생지역에 대한 일련의 현장조사와 지반안정성 분석은 체계적으로 수행되어야 한다. 본 연구에서는 충청북도 청원군에 위치한 석회석 광산의 일부 지점에서 발생한 지반침하의 원인을 규명하기 위하여 현장조사와 지반안정성 분석을 수행하였다. 이를 위하여 조사지역 암반의 공학적 특성을 조사하고, 전기비저항 탐사를 통해 지표 부근 연약대의 분포양상을 파악하였으며, 이 결과들을 토대로 침하원인 규명을 위한 전산해석을 수행하였다. 해석결과, 본 광산지역에서 발생된 지반침하는 석회암층에서 발달된 용식공동에 의한 것으로 분석되었다.

농소읍 부근 울산단층대에서의 P파 및 S파 탄성파 조사 연구 (P- and S-wave seismic studies in the Ulsan fault zone near Nongso-Eup)

  • 이창민;김기영
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2006년도 공동학술대회 논문집
    • /
    • pp.95-100
    • /
    • 2006
  • 울산단층의 지하구조를 확인하기 위하여 울산시 농소읍 부근에서 750 m의 측선을 따라 탄성파 자료를 획득하였다. 5 kg의 해머를 지표에 비스듬히 설치된 알루미늄 플레이트에 타격하여 P파와 S파를 동시에 발생시켰으며, 3 m 간격의 10 Hz 3성분 지오폰 16개로 수신하였다. P파 굴절파 자료는 토모그래피 방식으로 역산하였으며, 반사파 자료는 통상적인 처리과정에 경사경로시차보정, 구조보정 등의 과정을 추가하였다. P파 굴절파로부터 구한 속도정보와 S파 및 P파 반사파 중합단면을 해석하여 4개 층을 구분하였다. 상부로부터 각 층의 P파 속도는 $300{\sim}1100\;m/s$, $1100{\sim}1700\;m/s$, $1700{\sim}2700\;m/s$, 2700 m/s 이상이고, 상부 3개 층의 두께는 각각 평균 3.9 m, 5.9 m, 4.4 m 정도이다. S파 중합단면은 10 m 이내의 지질구조 규명에 효과적이었다.

  • PDF