• Title/Summary/Keyword: Substitute gas

Search Result 146, Processing Time 0.025 seconds

Research on Liquefaction Characteristics of SF6 Substitute Gases

  • Yuan, Zhikang;Tu, Youping;Wang, Cong;Qin, Sichen;Chen, Geng
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2545-2552
    • /
    • 2018
  • $SF_6$ has been widely used in high voltage power equipment, such as gas insulated switchgear (GIS) and gas insulated transmission line (GIL), because of its excellent insulation and arc extinguishing performance. However, $SF_6$ faces two environmental problems: greenhouse effect and high liquefaction temperature. Therefore, to find the $SF_6$ substitute gases has become a research hotspot in recent years. In this paper, the liquefaction characteristics of $SF_6$ substitute gases were studied. Peng-Robinson equation of state with the van der Waals mixing rule (PR-vdW model) was used to calculate the dew point temperature of the binary gas mixtures, with $SF_6$, $C_3F_8$, $c-C_4F_8$, $CF_3I$ or $C_4F_7N$ as the insulating gas and $N_2$ or $CO_2$ as the buffer gas. The sequence of the dew point temperatures of the binary gas mixtures under the same pressure and composition ratio was obtained. $SF_6/N_2$ < $SF_6/CO_2$ < $C_3F_8/N_2$ < $C_3F_8/CO_2$ < $CF_3I/N_2$ < $CF_3I/CO_2$ < $c-C_4F_8/N_2$ < $C_4F_7N/N_2$ < $c-C_4F_8/CO_2$ < $C_4F_7N/CO_2$. $SF_6/N_2$ gas mixture showed the best temperature adaptability and $C_4F_7N/CO_2$ gas mixture showed the worst temperature adaptability. Furthermore, the dew point temperatures of the $SF_6$ substitute gases at different pressures and the upper limits of the insulating gas mole fraction at $-30^{\circ}C$, $-20^{\circ}C$ and $-10^{\circ}C$ were obtained. The results would supply sufficient data support for GIS/GIL operators and researchers.

Compressed Natural Gas Bus & Liquefied Petroleum Gas Vehicle (압축천연가스(CNG)버스와 액화석유가스(LPG)자동차)

  • 윤재건
    • Journal of the Korean Professional Engineers Association
    • /
    • v.34 no.3
    • /
    • pp.28-32
    • /
    • 2001
  • Using the CNG(compressed natural gas) and LPG(liquified petroleum gas) as the automotive fuel will be expanded because of their clean effect to the environmental air qualify. But these programs of gas using expansion would have a difficulty due to public consideration of gas utilities as a big hazard. The Ministry of Environment has an ambitious plan to substitute more than 25,000 buses with CNG and ensure more than 200 CNG refueling stations as well by the year of 2007. However, it is very difficult to establish new CNG and LPG refueling stations because of expanded safety distance than ever before by several major explosion accidents.

  • PDF

A Study on Characteristics of Insulation Breakdown and Surface Discharge by the Oxygen Concentration in the Dry Air in Quasi-Uniform Field (준평등전계중 Dry Air내 산소의 농도에 따른 절연파괴 및 연면방전 특성 연구)

  • Beak, Jong-Hyun;Seok, Jeong-Hoo;Choi, Byoung-Ju;Bae, Sungwoo;Kim, Ki-Chai;Park, Won-Zoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.41-46
    • /
    • 2015
  • This study was conducted to discover a substitute of $SF_6$ gas. $SF_6$ gas is widely used across the industries. Thanks to superior electrical properties, in particular, it has been commonly used in electrical industry. However, there have been a lot of studies on its serious effect on global warming. As a substitute of this synthetic gas, a mixture of dry air and $N_2/O_2$ was chosen in this study. In case of $N_2/O_2$, dielectric strength differs depending on the mixing ratio. This study examined dielectric breakdown and flashover after adjusting oxygen percentage in the dry air. This test was conducted in a quasi-uniform electric field depending on pressure, oxygen concentration and gas mixtures. The test results found that dielectric voltage and flashover voltage were the highest at a certain oxygen concentration. It is the results of this photoionization and electron attachment of oxygen.

The Economic Aspect of Gas Hydrate Development (경제성 측면에서의 가스하이드레이트 개발 가치)

  • Kim, Hwa-Young;Lee, Dong-Jun;Heo, Eun-Nyeong
    • New & Renewable Energy
    • /
    • v.4 no.2
    • /
    • pp.61-67
    • /
    • 2008
  • The price to import natural gas continues to rise, as well as the rate of its domestic consumption. This research examined the economic feasibility of domestically developing and producing gas hydrate to substitute imported natural gas. Today, the industry still lacks the technology to commercially produce gas hydrate. However, if the gas hydrate is able to be commercially produced domestically and replace imported natural gas, the annual economic benefit for the Republic of Korea would be 211 - 833 USD/ton. Gas hydrate is rated as a high value investment by the gas industry since the potential annual profit can reach over 150USD/ton. The commercial value of gas hydrate development will increase as long as the natural gas market continues to expand and its consumption increase remains steady. With further development of technology, one can anticipate an even higher expected return on the investment.

  • PDF

The Economic Aspect of Gas Hydrate Development (경제성 측면에서의 가스하이드레이트 개발 가치)

  • Sin(Kim), Hwa-Young;Lee, Dong-Jun;Heo, Eun-Nyeong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.107-110
    • /
    • 2008
  • The price of natural gas import continues to rise, as well as its domestic consumption rate. This research examined the economic feasibility of domestically developing and producing gas hydrate to substitute imported natural gas. Today, the technology to commercially produce gas hydrate is still lacking; however, if the gas hydrate is able to be commercially produced domestically and replace imported natural gas, the annual economic benefit for the Republic of Korea would be 211 - 833 USD/ton. From the industry's point of view, gas hydrate is a high value investment since one can expect an annual profit of over 150USD/ton. The commercial value of gas hydrate development will increase as long as the natural gas market continues to expand and as the increase of natural gas consumption remains steady. With further development of technology, one can anticipate an even higher expected return on the investment.

  • PDF

Effect of a Preprocessing Method on Inverting Chemiluminescence Images of Flames Burning Substitute Natural Gas (대체천연가스 화염 이미지 역변환에서 전처리 효과)

  • Ahn, Kwangho;Song, Wonjoon;Cha, Dongjin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.12
    • /
    • pp.609-619
    • /
    • 2015
  • A preprocessing scheme utilizing multi-division of the ROI (region of interest) in a chemiluminescence image during inversion is proposed. The resulting inverted image shows the flame's structure, which can be useful for studying combustion instability. The flame structure is often quantitatively visualized with PLIF (planar laser-induced fluorescence) images as well. The chemiluminescence image, which is a line-integral of the flame, needs to be preprocessed before inversion, mainly due to the inherent noise and the assumption of axisymmetry during the inversion. The feasibility of the multi-division preprocessing technique has been tested with experimentally-obtained OH PLIF and $OH^*$ chemiluminescence images of jet and swirl-stabilized flames burning substitute natural gas (SNG). It turns out that the technique outperforms two conventional methods, specifically, the technique without preprocessing and the one with uni-division, reconstructing the SNG flame structures much better than its two counterparts when compared using corresponding OH PLIF images. The characteristics of the optimum degree of polynomials to be applied for curve-fitting of the flame region data for the multi-division method involving two flames has also been investigated.

Effect of Substitute Processed Dustproof Fly-Ash as a Bedding Materials at Pigpens (방진처리 석탄회의 돈사깔짚 대체 . 이용효과)

  • 김영민;김재황;김삼철;하홍민;고영두
    • Journal of Animal Environmental Science
    • /
    • v.6 no.3
    • /
    • pp.133-140
    • /
    • 2000
  • This study was carried out to determine a suitable mixing rate to utilize the PDF as a bedding materials at the pigpens and investigate the effect of substitute processed dustproof fly-ash(PDF) on the odor. In proportion to the increase of substitute rate of the PDF, the utilizable period was extended, and there was a little change of the moisture in the bedding materials. At all the treatment of PDF, there was the significant effect on the maggots and parasites but it didn\`t hinder in the biodegradation. According to highly mixing rate, PDF decreased in the noxious gas ($NH_3$ and $H_2$S) emission. In conclusion, the mixing rate of 30% or above this substituted level will increase replacement terms, and reduce the sawdust cost and the pollutions of breed pigs.

  • PDF

A Study of Gas Interchangeability on Natural Gas and LPG/Air Mixture (천연가스와 LPG/Air 혼합시 가스 호환성 연구)

  • 한정옥;유현석;방효선
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.11a
    • /
    • pp.126-138
    • /
    • 1995
  • In order to study the gas interchangeability, a series of tests and analysis were conducted regarding to natural gas and gas mixture. Natural gas was selected as a reference and NG-LPG/Air mixture as a substitute gas. The major interest was placed on the determination of interchangeability limits for different mixing conditions. The parameters of Wobbe Index and Combustion Potential were employed in estimating the gas interchangeability, The limits obtained by analysis(AGA, WEAVER, KNOY, GILB) were compared with experimental results. The results estimated showed that the mixing limits of LPG/Air in proper conditions were found to vary with analysis and AGA is considered to be the most appropriate one.

  • PDF

SNG Production Process Study in the gasification system with various feedstock (석탄, 석탄 촤, 바이오매스 등의 고체시료 가스화 반응을 통해 발생된 합성가스를 이용한 SNG 제조공정 연구)

  • Kim, Su-Hyun;Yoo, Young-Don;Kim, Mun-Hyun;Kim, Na-Rang;Kim, Hyung-Taek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.779-783
    • /
    • 2007
  • 본 연구에서는 가스화공정과 수성가스 전환공정, $CO_2$ 분리공정, 메탄화 공정을 주요 구성으로 한 대체(또는 합성)천연가스(SNG, Substitute or Synthetic Natural Gas)제조공정을 대상으로 석탄, 석탄 촤, 바이오매스 등의 다양한 고체시료를 적용하였을 경우 각 시료의 가스화 반응을 통해 얻어진 합성가스를 이용한 SNG 제조 공정 특성을 파악하고자 하였다. 석탄, 석탄 촤, 바이오매스를 적용한 SNG 공정해석 결과 가스화 공정, 수성가스 전환 공정, 메탄화 공정의 운전 용도가 각 800도, 450도, 300도이고, 수성가스 전환 공정 출구의 합성가스 $H_2$/CO ratio(mol basis)가 3인 조건에서 SNG/Feed ratio는 석탄, 석탄 촤, 바이오매스가 각각 0.35, 0.34, 0.08로 나타났고. SNG Efficiency(%) 는석탄, 석탄 촤 바이오매스에 대해서 각각 61.2%. 48.2%, 17.5%로 나타났다. 또한, 석탄 촤를 대상으로 가스화 공정에서의 산화제 투입 조건 및 스팀 투입조건의 변화에 따른 합성가스 발생 특성을 살펴보았다.

  • PDF