• 제목/요약/키워드: Subspace system identification

검색결과 49건 처리시간 0.028초

Joint Virtual User Identification and Channel Security En/Decoding Method for Ad hoc Network

  • Zhang, Kenan;Li, Xingqian;Ding, Kai;Li, Li
    • International Journal of Computer Science & Network Security
    • /
    • 제22권11호
    • /
    • pp.241-247
    • /
    • 2022
  • Ad hoc network is self-organized network powered by battery. The reliability of virtual user identification and channel security are reduced when SNR is low due to limited user energy. In order to solve this problem, a joint virtual user identification and channel security en/decoding method is proposed in this paper. Transmitter-receiver-based virtual user identification code is generated by executing XOR operation between orthogonal address code of transmitter and pseudo random address code of receiver and encrypted by channel security code to acquire orthogonal random security sequence so as to improve channel security. In order to spread spectrum as well as improve transmission efficiency, data packet is divided into 6-bit symbols, each symbol is mapped with an orthogonal random security sequence. Subspace-based method is adopted by receiver to process received signal firstly, and then a judgment model is established to identify virtual users according to the previous processing results. Simulation results indicate that the proposed method obtains 1.6dB Eb/N0 gains compared with reference methods when miss alarm rate reaches 10-3.

A Novel Active User Identification Method for Space based Constellation Network

  • Kenan, Zhang;Xingqian, Li;Kai, Ding;Li, Li
    • International Journal of Computer Science & Network Security
    • /
    • 제22권12호
    • /
    • pp.212-216
    • /
    • 2022
  • Space based constellation network is a kind of ad hoc network in which users are self-organized without center node. In space based constellation network, users are allowed to enter or leave the network at any given time. Thus, the number of active users is an unknown and time-varying parameter, and the performance of the network depends on how accurately this parameter is estimated. The so-called problem of active user identification, which consists of determining the number and identities of users transmitting in space based constellation network is discussed and a novel active user identification method is proposed in this paper. Active user identification code generated by transmitter address code and receiver address code is used to spread spectrum. Subspace-based method is used to process received signal and judgment model is established to identify active users according to the processing results. The proposed method is simulated under AWGN channel, Rician channel and Rayleigh channel respectively. Numerical results indicate that the proposed method obtains at least 1.16dB Eb/N0 gains compared with reference methods when miss alarm rate reaches 10-3.

LQG 설계에 의한 RTP 온도제어 시스템 (An RTP Temperature Control System Based on LQG Design)

  • 송태승;유준
    • 제어로봇시스템학회논문지
    • /
    • 제6권6호
    • /
    • pp.500-505
    • /
    • 2000
  • This paper deals with wafer temperature uniformity control essential in rapid thermal processing (RTP). One of the important control objectives of RTP is to keep the temperature over the wafer surface as uniformly as possible. For this, a discrete time state equation around the operating point is first identified by using the subspace fitting method, and a multivariable LQG(Linear Quadratic Gaussian) controller is designed based on the identified model. Simulation and experimental results show improvement in temperature uniformity over the conventional PID method.

  • PDF

구조안전도 평가를 위한 동적변위 기반 손상도 추정 기법 개발 (Damage estimation for structural safety evaluation using dynamic displace measurement)

  • 신윤수;김준희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권7호
    • /
    • pp.87-94
    • /
    • 2019
  • 최근 구조물 계측분야에서 구조물의 동적 변위응답 측정에 관한 연구가 주목을 받고 있다. 본 연구는 이와 같은 동적 변위데이터의 활용도를 넓히고자 구조안전도 평가를 위한 방법론 제시를 목표로, 동적 변위데이터를 활용하여 부공간 시스템 식별법이 적용된 구조물 물리량 추정기법을 개발하였다. 진동 변위 데이터로부터의 상태공간모델을 추정하기 위한 부공간 시스템 식별 이론과 시스템의 물리량을 도출하기 위한 물리해석 기법을 제시하였고 실험적 검증을 위해 동적 실험을 수행하였다. 3자유도 철골 구조물을 제작하여 진동대를 활용해 지반 가진하여 각 층의 변위 데이터와 진동대의 가속도 데이터를 계측하였다. 계측된 데이터를 활용해 이산화 된 상태공간모델을 생성하였고 정밀도 파악을 위해 상태공간방정식을 통한 전산 해석을 수행하였으며, 철제 구조물의 상태공간모델로부터 층강성을 추출하였다. 또한 상태공간모델로부터 추출된 층강성을 기준으로 5가지의 기둥강성 보강 및 손상 시나리오를 설정하여 매 시나리오별 층강성 변화율을 추출하였으며 동일한 조건의 보강 및 손상의 경우, 강성 변화가 높은 일치율을 보이는 것을 확인하였다.

Polymer Quality Control Using Subspace-based Model Predictive Control with BLUE Filter

  • Song, In-Hyoup;Yoo, Kee-Youn;Rhee, Hyun-Ku
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.357-357
    • /
    • 2000
  • In this study, we consider a multi-input multi-output styrene polymerization reactor system for which the monomer conversion and the weight average molecular weight are controlled by manipulating the jacket inlet temperature and the feed flow rate. The reactor system is identified by using a linear subspace identification method and then the output feedback model predictive controller is constructed on the basis of the identified model. Here we use the Best Linear Unbiased Estimation (BLUE) filter as a stochastic estimator instead of the Kalman filter. The BLUE filter observes the state successfully without any a priori information of initial states. In contrast to the Kalman filter, the BLUE filter eliminates the offset by observing the state of the augmented system regardless of a priori information of the initial state for an integral white noise augmented system. A BLUE filter has a finite impulse response (FIR) structure which utilizes finite measurements and inputs on the most recent time interval [i-N, i] in order to avoid long processing times.

  • PDF

Mode identifiability of a multi-span cable-stayed bridge utilizing stabilization diagram and singular values

  • Goi, Y.;Kim, C.W.
    • Smart Structures and Systems
    • /
    • 제17권3호
    • /
    • pp.391-411
    • /
    • 2016
  • This study investigates the mode identifiability of a multi-span cable-stayed bridge in terms of a benchmark study using stabilization diagrams of a system model identified using stochastic subspace identification (SSI). Cumulative contribution ratios (CCRs) estimated from singular values of system models under different wind conditions were also considered. Observations revealed that wind speed might influence the mode identifiability of a specific mode of a cable-stayed bridge. Moreover the cumulative contribution ratio showed that the time histories monitored during strong winds, such as those of a typhoon, can be modeled with less system order than under weak winds. The blind data Acc 1 and Acc 2 were categorized as data obtained under a typhoon. Blind data Acc 3 and Acc 4 were categorized as data obtained under wind conditions of critical wind speeds around 7.5 m/s. Finally, blind data Acc 5 and Acc 6 were categorized as data measured under weak wind conditions.

Operational modal analysis for Canton Tower

  • Niu, Yan;Kraemer, Peter;Fritzen, Claus-Peter
    • Smart Structures and Systems
    • /
    • 제10권4_5호
    • /
    • pp.393-410
    • /
    • 2012
  • The 610 m high Canton Tower (formerly named Guangzhou New Television Tower) is currently considered as a benchmark problem for structural health monitoring (SHM) of high-rise slender structures. In the benchmark study task I, a set of 24-hour ambient vibration measurement data has been available for the output-only system identification study. In this paper, the vector autoregressive models (ARV) method is adopted in the operational modal analysis (OMA) for this TV tower. The identified natural frequencies, damping ratios and mode shapes are presented and compared with the available results from some other research groups which used different methods, e.g., the data-driven stochastic subspace identification (SSI-DATA) method, the enhanced frequency domain decomposition (EFDD) algorithm, and an improved modal identification method based on NExT-ERA technique. Furthermore, the environmental effects on the estimated modal parameters are also discussed.

Modal testing and finite element model calibration of an arch type steel footbridge

  • Bayraktar, Alemdar;Altunisk, Ahmet Can;Sevim, Baris;Turker, Temel
    • Steel and Composite Structures
    • /
    • 제7권6호
    • /
    • pp.487-502
    • /
    • 2007
  • In recent decades there has been a trend towards improved mechanical characteristics of materials used in footbridge construction. It has enabled engineers to design lighter, slender and more aesthetic structures. As a result of these construction trends, many footbridges have become more susceptible to vibrations when subjected to dynamic loads. In addition to this, some inherit modelling uncertainties related to a lack of information on the as-built structure, such as boundary conditions, material properties, and the effects of non-structural elements make difficult to evaluate modal properties of footbridges, analytically. For these purposes, modal testing of footbridges is used to rectify these problems after construction. This paper describes an arch type steel footbridge, its analytical modelling, modal testing and finite element model calibration. A modern steel footbridge which has arch type structural system and located on the Karadeniz coast road in Trabzon, Turkey is selected as an application. An analytical modal analysis is performed on the developed 3D finite element model of footbridge to provide the analytical frequencies and mode shapes. The field ambient vibration tests on the footbridge deck under natural excitation such as human walking and traffic loads are conducted. The output-only modal parameter identification is carried out by using the peak picking of the average normalized power spectral densities in the frequency domain and stochastic subspace identification in the time domain, and dynamic characteristics such as natural frequencies mode shapes and damping ratios are determined. The finite element model of footbridge is calibrated to minimize the differences between analytically and experimentally estimated modal properties by changing some uncertain modelling parameters such as material properties. At the end of the study, maximum differences in the natural frequencies are reduced from 22% to only %5 and good agreement is found between analytical and experimental dynamic characteristics such as natural frequencies, mode shapes by model calibration.

Instrumentation and system identification of a typical school building in Istanbul

  • Bakir, Pelin Gundes
    • Structural Engineering and Mechanics
    • /
    • 제43권2호
    • /
    • pp.179-197
    • /
    • 2012
  • This study presents the findings of the structural health monitoring and the real time system identification of one of the first large scale building instrumentations in Turkey for earthquake safety. Within this context, a thorough review of steps in the instrumentation, monitoring is presented and seismic performance evaluation of structures using both nonlinear pushover and nonlinear dynamic time history analysis is carried out. The sensor locations are determined using the optimal sensor placement techniques used in NASA for on orbit modal identification of large space structures. System identification is carried out via the stochastic subspace technique. The results of the study show that under ambient vibrations, stocky buildings can be substantially stiffer than what is predicted by the finite element models due to the presence of a large number of partitioning walls. However, in a severe earthquake, it will not be safe to rely on this resistance due to the fact that once the partitioning walls crack, the bare frame contributes to the lateral stiffness of the building alone. Consequently, the periods obtained from system identification will be closer to those obtained from the FE analysis. A technique to control the validity of the proportional damping assumption is employed that checks the presence of phase difference in displacements of different stories obtained from band pass filtered records and it is confirmed that the "proportional damping assumption" is valid for this structure. Two different techniques are implemented for identifying the influence of the soil structure interaction. The first technique uses the transfer function between the roof and the basement in both directions. The second technique uses a pre-whitening filter on the data obtained from both the basement and the roof. Subsequently the impulse response function is computed from the scaled cross correlation between the input and the output. The overall results showed that the structure will satisfy the life safety performance level in a future earthquake but some soil structure interaction effects should be expected in the North South direction.

Influence of asphalt removal on operational modal analysis of Egebækvej Bridge

  • Umut Yildirim
    • Smart Structures and Systems
    • /
    • 제31권2호
    • /
    • pp.171-181
    • /
    • 2023
  • Using the most up-to-date system identification methods in both time and frequency domains, the dynamic monitoring data from the reinforced concrete Egebaekvej Bridge near Holte, Denmark, is examined in this investigation. The bridge was erected in the 1960s and was still standing during test campaign before demolishing. The ARTeMIS Modal was adopted to derive the modal parameters from ambient vibration data. Several Operational Modal Analysis (OMA) approaches were applied, including Enhanced Frequency Domain Decomposition (EFDD), Curve-fit Frequency Domain Decomposition (CFDD), and Frequency Domain Decomposition (FDD). Afterward, Principal Component (SSI-PC), Unweighted Principal Component (SSI-UPC) Stochastic Subspace Identification methods were utilized. Danish engineering consulting company, COWI with the allowance of the bridge contractor BARSLUND, allow the researcher for this experimental test to demonstrate the impact of OMA applications.