• Title/Summary/Keyword: Subjective refraction

Search Result 55, Processing Time 0.022 seconds

Comparison and Analysis for the Effects of Functional Progressive Addition Lenses on Binocular Vision of University Students (기능성 누진가입도렌즈가 대학생들의 양안시기능에 미치는 영향 비교 분석)

  • Kim, Chang Jin;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.105-116
    • /
    • 2010
  • Purpose: To analyze and compare differences between single vision lenses and functional progressive addition lenses and improvement to binocular visual function wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses (EYE-T, Chemilens Co., Korea, ADD 0.750) for 2 months. Objective refraction, corrected visual acuity at distance and near, near point of convergence, near point of accommodation, accommodative facility, phoria at distance and near were measured. And subjective satisfaction was investigated by using a questionnaire designed to fatigue, comfort, discomfort, overall satisfaction and preference. Results: Functional progressive addition lenses were better than single vision lenses at near point of convergence and accommodation, accommodative facility. Exo phoria measured at distance with single vision and functional progressive addition lenses. Exo phoria measured at near with functional progressive addition lenses was higher than that with single vision lenses. As a survey, the satisfaction was increased in questions related near work. However, single vision lenses were preferred in distance test of overall satisfaction, easy 10 adapt, lime to adapt. A survey showed thai preference of functional progressive addition lenses were increased 75.00% to 81.26% for near work, 50.00% to 65.63% for visual fatigue, 47.75% to 50.00% for visual comfort and 31.25% to 46.88% for overall comfort. Conclusions: Comparing between single vision lenses and functional progressive addition lenses, binocular visual function related near work, subjective satisfaction and preference was improved after wearing functional progressive addition lenses. This study suggested that functional progressive addition lenses were useful for long time near work.

Effect of Vision Training using Fresnel Prism Lens on Fusional Vergence and Accommodation (프레넬 프리즘렌즈를 이용한 시기능 훈련이 조절과 융합버전스에 미치는 영향)

  • Kim, Yong-Gil;Kim, Min-Kyung;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.159-164
    • /
    • 2012
  • Purpose: Of the various methods of vision training, the essay aims to explore the effective ways of using the Fresnel prism lens in order to expand the positive fusional vergence for the patient having specific condition of convergence insufficiency or basic exophoria. Methods: 15 students of city of Daejeon university without an eye disease (average age $22.73{\pm}1.68$) were selected and underwent the subjective refraction test and binocular vision test, and recording their test results before vision training and replacing an identical frame with a lens of same quality after the full calibration, the lens was then adhered with the Fresnel prism lens and continued to train for thirty minutes daily during two weeks. Afterwards, the binocular vision test was reattempted. The observation of the change in the results of the binocular vision test in use of the fresnel prism lens in the vision training test was researched. Results: After training, the positive fusional vergence had increased to a number of $22.27{\pm}2.26$ $\Delta$, to 7.80 $\Delta$, at near, the fused cross cylinder test increased to an average of $0.55{\pm}0.09$ D, 0.40 D after training, showing a normal result. The value of negative relative accommodation after training had an average of $2.22{\pm}0.08$D, showing that 0.42 D had increased. The value of near point of convergence after training had an average of $6.13{\pm}0.53$ cm, showing that 2.80 cm had decreased. To patients who had convergence insufficiency or basic exophoria, the value of the near vision test that used the Fresnel prism lens which was able to expand BO positive fusional vergence had increased without phoria. Conclusions: The changes were tested and the effectiveness of the Fresnel prism lens, due to the nature of the lens itself, helped with both cosmetic effects and cost. It also allows good optical correction effects, in addition to these clinical effects indicated before. Therefore, it may be determined that the Fresnel prism lens binocular vision therapy for patients is more popular and highly recommended.

Trends and Refractive Status of Cataract Surgery - An Optometry Clinic-Based Survey in Chungbuk (백내장 수술 경향과 굴절상태 - 충북 지역의 안경원 중심으로 조사)

  • Kim, Hyeong-Su;Son, Jeong-Sik;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.143-148
    • /
    • 2013
  • Purpose: The aim of this study was to investigate the distribution of age and gender, types of intraocular lens (IOL), and refractive errors in subjects who had cataract surgery. Methods: 2,217 subjects who had cataract surgery were surveyed at an optometry clinic in Chungbuk from 2010 to 2012. Information about IOL was obtained from case history, reflective and retroillumination images IOL by auto refracto-keratometer. Refractive errors were determined by objective and subjective refraction. Results: The mean age of the subjects was $71.74{\pm}10.62$ years. The number of cataract surgeries increased from 524 persons in 2010 to 888 persons in 2012. Of the subjects surveyed, 52 persons (2.3%) were under the 40 years of age, 144 persons (6.5%) were in 50s, 404 persons (18.2%) were in 60s, 1,132 persons (51.1%) were in 70s, 485 persons (21.9%) were in above 80s. Cataract surgery was significantly prevalent in more female (1,338 persons, 60.4%) than in male (879 persons, 39.6%). Types of IOL were 2,141 persons (96.6%) for monofocal lens, special IOLs such as multifocal, accommodative and toric lens were 76 persons (3.4%). The distribution of refractive errors after cataract operation were 1,588 eyes (38.5%) for simple myopic astigmatism, 327 eyes (7.9%) for simple hyperopic astigmatism, 601 eyes (14.6%) for mixed astigmatism, 1,240 eyes (30.0%) for myopia, 136 eyes (3.3%) for hyperopia, and 234 eyes (5.7%) for emmetropia. The uncorrected and best corrected visual acuity of the subjects were $0.55{\pm}0.25$ and $0.80{\pm}0.23$, respectively. Conclusions: The prevalence of cataract surgery increased with age until 70s years of age, it was more prevalent in men than women over 60s, and frequency of special types of IOL were low. Most cataract surgeries left residual refractive errors. Therefore even after cataract surgery it may need spectacles for better vision at either distance or near.

Reliability of Autorefractometry after Corneal Refractive Surgery (레이저 굴절교정수술 후 자동굴절검사법의 신뢰성)

  • Lee, Ki-Seok
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.443-451
    • /
    • 2018
  • Purpose : To find out the reliability of autorefractometer after laser refractive surgery Methods : We measured and compared spherical and cylinder powers of those undergone LASEK surgery with 1.0 of naked vision after at least 3 months of the surgery with an autorefractometer(CANON Full Auto Ref-Keratometer RK-F1, Japan) and a retinoscope(Streak Retinoscope 18200, WelchAllyn, USA), and also applied spherical equivalent powers. The refractive status before surgery was divided into high, medium, and low myopia according to the results measured using an autorefractometer, and then analyzed again the reliability of the autorefractometer after surgery according to the preoperative refractive status. The agreement of two methods was identified using Bland-Altman(Bland-Altman limits of agreement(LoA)). Results : After the surgery, when comparing spherical, cylinder and equivalent powers in the whole data measured by autorefractometry and retinoscopy significant differences were found(p<0.01). According to the degree of refractive errors, all sort of refractive errors was shown significantly different(p<0.01) except for cylinder power of the medium myopia. In general, the refractive errors especially spherical and spherical equivalent powers by autorefractometry were shown a myopic trend from -0.38 D to -0.53 D. On the other hand, it was shown a hyperopic trend of approximately +0.30 D using retinoscopy. In comparison of two objective refractions, it was shown a myopic trend as $-0.51{\pm}0.45D$(LoA +0.36 D ~ -1.39 D) and compatible. Conclusion : Even though it would be positive in terms of compatibility of the methods, it is necessary that the glasses should be prescribed by subjective refraction since autorefractometry is shown myopic in those undergone the surgery and suffering from myopic regression.

Comparison of Ultrasound Image Quality using Edge Enhancement Mask (경계면 강조 마스크를 이용한 초음파 영상 화질 비교)

  • Jung-Min, Son;Jun-Haeng, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.157-165
    • /
    • 2023
  • Ultrasound imaging uses sound waves of frequencies to cause physical actions such as reflection, absorption, refraction, and transmission at the edge between different tissues. Improvement is needed because there is a lot of noise due to the characteristics of the data generated from the ultrasound equipment, and it is difficult to grasp the shape of the tissue to be actually observed because the edge is vague. The edge enhancement method is used as a method to solve the case where the edge surface looks clumped due to a decrease in image quality. In this paper, as a method to strengthen the interface, the quality improvement was confirmed by strengthening the interface, which is the high-frequency part, in each image using an unsharpening mask and high boost. The mask filtering used for each image was evaluated by measuring PSNR and SNR. Abdominal, head, heart, liver, kidney, breast, and fetal images were obtained from Philips epiq5g and affiniti70g and Alpinion E-cube 15 ultrasound equipment. The program used to implement the algorithm was implemented with MATLAB R2022a of MathWorks. The unsharpening and high-boost mask array size was set to 3*3, and the laplacian filter, a spatial filter used to create outline-enhanced images, was applied equally to both masks. ImageJ program was used for quantitative evaluation of image quality. As a result of applying the mask filter to various ultrasound images, the subjective image quality showed that the overall contour lines of the image were clearly visible when unsharpening and high-boost mask were applied to the original image. When comparing the quantitative image quality, the image quality of the image to which the unsharpening mask and the high boost mask were applied was evaluated higher than that of the original image. In the portal vein, head, gallbladder, and kidney images, the SNR, PSNR, RMSE and MAE of the image to which the high-boost mask was applied were measured to be high. Conversely, for images of the heart, breast, and fetus, SNR, PSNR, RMSE and MAE values were measured as images with the unsharpening mask applied. It is thought that using the optimal mask according to the image will help to improve the image quality, and the contour information was provided to improve the image quality.