Extremity Amputation following Radial Artery Cannulation in Patient with Craniectomy (경피요골동맥삽관후 발생된 수지괴사 1례)

  • Kim, Heung-Dae;Song, Sun-Ok;Lee, Kyeung-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.4 no.1
    • /
    • pp.145-149
    • /
    • 1987
  • The technique of radial artery cannulation and its complications are well documented, but serious complications are rare. This is a report of one case of amputation of wrist due to finger necrosis developed from the radial artery cannulation in patient who had craniectomy surgery. This 52-year-old 70kg male underwent subdural hematoma removal surgery. Right radial artery cannulation was carried out percutaneously using 22 gauge Teflon extracath needle after modified Allen's test appeared to be positive. It was intermittently flushed by heparinized solution. His arterial blood pressure was maintained 100/70 - 110/80mmHg and 5 units of banked whole blood and 1 unit of fresh frozen plasma were transfused during 8-hours operation. Cannula was removed on the 9th hour after operation because that was obstructed. On the 12th hour after removal of cannula, his right hand noted to be cool and cyanotic. So, warm towel and hot bag applied continuonsly on the right hand and the right stellate ganglion block was carried out everyday for 4 times. However, on the 10th day after removal of cannula, necrotic change of all fingers of the right hand became worse and skin of fingers were shrunken. Therefore, disarticulation of the right wrist carried out on the 71th day of his hospitalization.