• Title/Summary/Keyword: Sub-division method

Search Result 853, Processing Time 0.023 seconds

Electrodeposition of Ni-W/Al2O3 Nano-Composites and the Influence of Al2O3 Incorporation on Mechanical and Corrosion Resistance Behaviours

  • M. Ramaprakash;R. Nivethida;A. Muthukrishnan;A. Jerom Samraj;M. G. Neelavannan;N. Rajasekaran
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.377-387
    • /
    • 2023
  • Ni-W/Al2O3 nano-composites were electrodeposited on mild steel substrate for mechanical and corrosion resistance applications. This study focused on the preparation of Ni-W/Al2O3 nano-composite coating with various quantity of Al2O3 incorporations. The addition of Al2O3 in the electrolytes were varied from 1-10 g/L in electrolytes and the Al2O3 incorporation in Ni-W/Al2O3 nano-composite coatings were obtained from 1.82 to 13.86 wt.%. The incorporation of Al2O3 in Ni-W alloy matrix influenced the grain size, surface morphology and structural properties were observed. The distributions of Al2O3 particle in alloy matrix were confirmed using electron microscopy (FESEM and TEM) and EDAX mapping analysis. The crystal structure informations were studied using X-ray diffraction method and it confirms that the deposits having cubic crystal structure. The better corrosion rate (0.87 mpy) and microhardness (965 HV) properties were obtained for the Ni-W/Al2O3 nano-composite coating with 13.86 wt.% of Al2O3 incorporations.

The method for total organic carbon analysis employing TiO2 photocatalyst (이산화티타늄 광촉매를 이용한 총유기탄소 분석방법)

  • Park, Buem Keun;Kim, Sung Mi;Lee, Young-Jin;Paik, Jong-Hoo;Shin, Jeong Hee
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.320-325
    • /
    • 2021
  • Biochemical oxygen demand (BOD) and chemical oxygen demand (COD) methods are conventional analytical methods to analyze water quality. Both of these methods are technically indirect measurement methods, require complicated preconditions, and are time-consuming. On the other hand, the total organic carbon (TOC) method is a direct and fast measurement method which is more intuitive and accurate than the BOD and COD methods. However, general TOC analysis methods involve complicated processes and high power consumption owing to the process of phase transition from liquid to gas by a high-temperature heater. Furthermore, periodic consumables are also required for the removal of inorganic carbon (IC). Titanium dioxide (TiO2) is one of the most suitable photocatalysts for simple processes. Its usage involves low power consumption because it only reacts with the organic carbon (OC) without the requirement of any other reagents and extra processes. We investigated a TiO2 photocatalyst-based TOC analysis for simple and affordable products. TiO2-coated fiber substrate maintained under carbon included water was exposed to ultraviolet (UV) radiation of wavelength 365 nm. This method is suitable for the real-time monitoring of water pollution because of its fast reaction time. Its linear property is also sufficient to match the real value.

Thermoelectric Properties of n-Type Half-Heusler Compounds Synthesized by the Induction Melting Method

  • Du, Nguyen Van;Lee, Soonil;Seo, Won-Seon;Dat, Nguyen Minh;Meang, Eun-Ji;Lim, Chang-Hyun;Rahman, Jamil Ur;Kim, Myong Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.6
    • /
    • pp.342-345
    • /
    • 2015
  • The n -type Hf0.25Zr0.25Ti0.5NiSn0.998Sb0.002 Half-Heusler (HH) alloy composition was prepared by using the induction melting method in addition to the mechanical grinding, annealing, and spark plasma sintering processes. Analysis of X-ray diffraction (XRD) results indicated the formation of a pure phase HH structured compound. The electrical and thermal properties at temperatures ranging from room temperature to 718 K were investigated. The electrical conductivity increased with increasing temperatures and demonstrated nondegenerate semiconducting behavior, and a large reduction in the thermal conductivity to the value of 2.5 W/mK at room temperature was observed. With the power factor and thermal conductivity, the dimensionless figure of merit was increased with temperature and measured at 0.94 at 718 K for the compound synthesized by the induction melting process.

Study on a Phosphorylation of Rare Earth Nuclide (Nd) in LiCl-KCl-NdCl3 System using Li3PO4-K3PO4 (LiCl-KCl-NdCl3계에서 Li3PO4-K3PO4를 이용한 희토류 핵종(Nd) 인산화에 관한 연구)

  • Eun, Hee-Chul;Kim, Jun-Hong;Choi, Jung-Hoon;Cho, Yung-Zun;Lee, Tae-Kyo;Park, Hwan-Seo;Park, Geun-Il
    • Journal of Advanced Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.125-129
    • /
    • 2013
  • In the pyrochemcial process of spent nuclear fuel, it is necessary to separate rare earth nuclides from LiCl-KCl eutectic waste salt for radioactive waste reduction. This paper presents the phosphorylation of neodymium chloride in LiCl-KCl-NdCl3 system using Li3PO4-K3PO4 as a phosphorylation agent in a chemical reactor with pitched blade impellers. The phosphorylation test was performed changing operation temperature, stirring rate, and amount of phosphorylation agent. Neodymium chloride was effectively converted into neodymium phosphate (NdPO4). It was confirmed that more than 99 wt% of neodymium can be separated from LiCl-KCl-NdCl3 system using a phosphorylation method l

Image Enhancement for Sub-Harmonic Phased Array by Removing Surface Wave Interference with Spatial Frequency Filter

  • Park, Choon-Su;Kim, Jun-Woo;Cho, Seung Hyun;Seo, Dae-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.211-219
    • /
    • 2014
  • Closed cracks are difficult to detect using conventional ultrasonic testing because most incident ultrasound passes completely through these cracks. Nonlinear ultrasound inspection using sub-harmonic frequencies a promising method for detecting closed cracks. To implement this method, a sub-harmonic phased array (PA) is proposed to visualize the length of closed cracks in solids. A sub-harmonic PA generally consists of a single transmitter and an array receiver, which detects sub-harmonic waves generated from closed cracks. The PA images are obtained using the total focusing method (TFM), which (with a transmitter and receiving array) employs a full matrix in the observation region to achieve fine image resolution. In particular, the receiving signals are measured using a laser Doppler vibrometer (LDV) to collect PA images for both fundamental and sub-harmonic frequencies. Oblique incidence, which is used to boost sub-harmonic generation, inevitably produces various surface waves that contaminate the signals measured in the receiving transducer. Surface wave interference often degrades PA images severely, and it becomes difficult to read the closed crack's position from the images. Various methods to prevent or eliminate this interference are possible. In particular, enhancing images with signal processing could be a highly cost-effective method. Because periodic patterns distributed in a PA image are the most frequent interference induced by surface waves, spatial frequency filtering is applicable for removing these waves. Experiments clearly demonstrate that the spatial frequency filter improves PA images.

Synthesis and Characterization of Bi2Sr2Ca2Cu3Ox Powders by Ultrasonic Spray Pyrolysis Method (Ultrasonic Spray Pyrolysis 법에 의한 Bi2Sr2Ca2Cu3Ox 분말합성 및 특성평가)

  • Bae, Bung-Su;Jung, Sang-Jin;Lee, Bong;Moon, Chang-Kwun;Choi, Hee-Lack
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.6
    • /
    • pp.86-91
    • /
    • 2010
  • Superconductor material $Bi_2Sr_2Ca_2Cu_3O_x$(Bi-2223) powders were synthesized by ultrasonic spray pyrolysis method. It is clear that Bi-2223 phase more than Bi-2212 phase was acquired at sufficient synthesized time. Best condition for Bi-2223 phase was synthesizing temperature at $860^{\circ}C$. We also investigated the effects for concentrations and viscosities of starting liquid precursor as well as temperature distribution of reacting furnace. The size of synthesized powder was decreased by decreasing the concentration of starting liquid precursor. Modified reacting furnace with four different temperature heating zones gave us successful results for desirable nano-powder including $Bi_2Sr_2Ca_2Cu_3O_x$ phase. Citric acid addition to starting liquid precursor showed increasing of the size for synthesized powder. Bi-2223 single phase was acquired from Bi2223 and Bi-2212 mixed phases through heat treatment in box furnace at 24 hours.

Comparison of Vitamin B5 Content and True Retention in Commonly Consumed Vegetables by Different Cooking Methods (국내 다소비 채소류의 조리에 따른 비타민 B5 함량 및 잔존율 비교)

  • Jin Ju, Park;Arin, Park;Eunji, Park;Youngmin, Choi
    • Journal of the Korean Society of Food Culture
    • /
    • v.37 no.6
    • /
    • pp.540-546
    • /
    • 2022
  • This study aimed to determine the changes in the vitamin B5 content of raw and cooked vegetables. The nineteen vegetables were subjected to different cooking methods, viz. blanching, boiling, pan-broiling, and steaming. Vitamin B5 was quantified by reversed-phase high-performance liquid chromatography (HPLC) using photodiode-array (PDA) detection (200 nm). The standard reference materials (SRM) were used to validate the accuracy of vitamin B5 measurement method used in this study. The cooking yields ranged from 82.63 to 107.62% and decreased in most of the vegetables except bitter melon, curled mallow, and eggplant. The raw kabocha squash, Danhobak, had the highest vitamin B5 content (0.671 mg/100 g) among the samples. All cooked vegetables showed lower vitamin B5 content compared to the raw samples. The true retention ranged from 0% (crown daisy, blanching) to 84.49% (kabocha squash, steaming). These results indicate that vitamin B5 is degraded after cooking. Pan-broiling and steaming are better cooking methods than the others for retaining vitamin B5. The true retention of vitamin B5 in the samples markedly depends on the cooking method and food matrix. These results can be used as important basic data for nutritional evaluation of meals.

Characteristics of LiMn2O4 Cathode Material Prepared by Precipitation-Evaporation Method for Li-ion Secondary Battery (침전-증발법에 의해 제조된 리튬이온 2차 전지용 LiMn2O4 양극재료의 특성)

  • Kim, Guk-Tae;Yoon, Duck-Ki;Shim, Young-Jae
    • Korean Journal of Materials Research
    • /
    • v.12 no.9
    • /
    • pp.712-717
    • /
    • 2002
  • New wet chemical method so called precipitation-evaporation method was suggested for preparing spinel structure lithium manganese oxide ($LiMn_2$$O_4$) for Li ion secondary battery. Using precipitation-evaporation method, $LiMn_2$$O_4$ cathode materials suitable for Li ion secondary batteries can be synthesized. Single spinel phase $LiMn_2$$O_4$ powder was synthesized at lower temperature compared to that of prepared by solid-state method. $LiMn_2$$O_4$ powder prepared by precipitation-evaporation method showed uniform, small size and well defined crystallinity particles. Li ion secondary battery using $LiMn_2$$O_4$ as cathode materials prepared by precipitation-evaporation method and calcined at $800^{\circ}C$ showed discharge capacity of 106.03mAh/g and discharge capacity of 95.60mAh/g at 10th cycle. Although Li ion secondary battery showed somewhat smaller initial capacity but good cyclic ability. It is suggested that electro-chemical properties can be improved by controlling particle characteristics by particle morphology modification during calcination and optimizing Li ion secondary battery assembly conditions.

Hydrogen sensor using Pt-loaded porous In2O3 nanoparticle structures (백금 담지 다공성 산화인듐 나노입자 구조를 이용한 수소센서)

  • Sung Do Yun;Yoon Myung;Chan Woong Na
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.6
    • /
    • pp.420-426
    • /
    • 2023
  • We prepared a highly sensitive hydrogen (H2) sensor based on Indium oxides (In2O3) porous nanoparticles (NPs) loaded with Platinum (Pt) nanoparticle in the range of 1.6~5.7 at.%. In2O3 NPs were fabricated by microwave irradiation method, and decorations of Pt nanoparticles were performed by electroless plating on In2O3 NPs. Crystal structures, morphologies, and chemical information on Pt-loaded In2O3 NPs were characterized by grazing-incident X-ray diffraction, field-emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, respectively. The effect of the Pt nanoparticles on the H2-sensing performance of In2O3 NPs was investigated over a low concentration range of 5 ppm of H2 at 150-300 ℃ working temperatures. The results showed that the H2 response greatly increased with decreasing sensing temperature. The H2 response of Pt loaded porous In2O3 NPs is higher than that of pristine In2O3 NPs. H2 gas selectivity and high sensitivity was explained by the extension of the electron depletion layer and catalytic effect. Pt loaded porous In2O3 NPs sensor can be a robust manner for achieving enhanced gas selectivity and sensitivity for the detection of H2.

Effects of A-site Vacancies on the Piezoelectric Properties of 0.97Bi0.5+x(Na0.78K0.22)0.5-3xTiO3-0.03LaFeO3 Lead-free Piezoelectric Ceramics (A-site Vacancy가 0.97Bi0.5+x(Na0.78K0.22)0.5-3xTiO3-0.03LaFeO3 무연압전 세라믹스의 압전특성에 미치는 영향)

  • Park, Jung Soo;Lee, Ku Tak;Cho, Jeong Ho;Jeong, Young Hun;Paik, Jong Hoo;Yun, Ji Sun
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.6
    • /
    • pp.527-532
    • /
    • 2014
  • $0.97Bi_{0.5+x}(Na_{0.78}K_{0.22})_{0.5-3x}TiO_3-0.03LaFeO_3$ lead-free piezoelectric ceramics were fabricated by a solid state reaction method. $LaFeO_3$ additives were added to $Bi_{0.5}(Na_{0.78}K_{0.22})_{0.5}TiO_3$ for volatile compensation of bismuth and sodium ions in the sintering process. To create A-site vacancies, the mole ratio and charge valence of A-site ions ($Bi^{3+}$, $Na^+$ and $K^+$) were controlled. The improved piezoelectric properties were observed by addition of $LaFeO_3$ and control of A-site vacancies. In particular, a $d_{33}^*(S_{max}/E_{max})$ value of 614pm/V and an electric field induced strain of 0.33% was observed in $0.97Bi_{0.505}(Na_{0.78}K_{0.22})_{0.485}TiO_3-0.03LaFeO_3$ ceramic.