• 제목/요약/키워드: Sub-cooled

검색결과 185건 처리시간 0.023초

An Overall Investigation of Break Simulators for LOCA Scenarios in Integral Effect Tests

  • Kim, Yeon-Sik;Park, Hyun-Sik
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.73-88
    • /
    • 2014
  • Various studies on the critical flow models for sub-cooled and/or saturated water were reviewed, especially on Fauske, Moody, and Henry for basic theoretical models; Zaloudek for insight into physical phenomena for a critical flow in an orifice type flow path; Sozzi & Sutherland for a critical flow test of saturated and sub-cooled water at high pressure for orifice and nozzles; and a Marviken test on a full-scale critical flow test. In addition, critical flow tests of sub-cooled water for the break simulators in integral effect test (IET) facilities were also investigated, and a hybrid concept using Moody's and Fauske's models was considered by the authors. In the comparison of the models for the selected test data, discussions of the effect of the diameters, predictions of the critical flow models, and design aspects of break simulator for SBLOCA scenarios in the IET facilities were presented. In the effect of diameter on the critical flow rate with respect to all dimensional scales, it was concluded that the effect of diameter was found irrespective of diameter sizes. In addition, the diameter effect on slip ratio affecting the critical flow rate was suggested. From a comparison of the critical flow models and selected test data, the Henry-Fauske model of the MARS-KS code was found to be the best model predicting the critical flow rate for the selected test data under study.

Study on the Dielectric Characteristics of Gaseous Nitrogen for Designing a High Voltage Superconducting Fault Current Limiter

  • Heo, Jeong-Il;Hong, Jong-Gi;Nam, Seok-Ho;Kang, Hyoung-Ku
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.28-31
    • /
    • 2012
  • The study on the dielectric characteristics of gaseous insulation medium is important for designing current leads of superconducting machines using a sub-cooled liquid nitrogen ($LN_2$) cooling method. In a sub-cooled $LN_2$ cooling system, the temperature of gaseous insulation medium surrounding current leads varies from the temperature of coolant to 300 K according to the displacement between the electrode system and the surface of sub-cooled $LN_2$. In this paper, AC withstand voltage experiments on gaseous nitrogen according to temperature are conducted. Also, AC withstand voltage experiments on gaseous nitrogen according to pressure, size of electrode, and gap length between two electrodes are performed. It is found that there is a functional relation between the electrical breakdown voltage and the field utilization factor (${\xi}$). As a result, the empirical formula for estimating an electrical breakdown voltage is deduced by adopting the concept of field utilization factors. It is expected that the experimental results presented in this paper are helpful to design current leads for a high voltage superconducting apparatus such as a superconducting fault current limiter (SFCL) using a sub-cooled $LN_2$ cooling system.

REBCO coil operation in gaseous helium and solid nitrogen

  • Diev, D.N.;Makarenko, M.N.;Naumov, A.V.;Polyakov, A.V.;Shcherbakov, V.I.;Shutova, D.I.;Surin, M.I.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권3호
    • /
    • pp.47-50
    • /
    • 2019
  • The paper gives the results of the experiments with a model two-section REBCO solenoid cooled by either gaseous helium (GHe) or sub-cooled/solid nitrogen (SN2) in (50-77) K temperature range. The major cooling source was a single-stage cryocooler Sumitomo CH-110 with the cooling power of 175 W and 130 W at 77 K and 50 K respectively. The coil itself was not directly conduction cooled. We compare the time taken by both coolants to obtain the temperature of the magnet of about 50 K and the homogeneity of the temperature distribution within the cryostat. Test results for the coil operation in solid nitrogen together with the comparison of its critical properties in SN2 and GHe are also presented.

평판휜-관 응축기의 수치 시뮬레이션 (Numerical Simulation of Plate Finned-Tubes Condenser)

  • 민묘식;최상경
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.193-205
    • /
    • 1994
  • A simulation program of the plate finned-tubes condenser widely used in the air conditioning system was developed. The program took into account the variations of the flow properties and fluid friction factor of refrigerant, and the heat transfer coefficients of refrigerant and air sides. The program was applied to a copper tube condenser which has outside diameter of 10.05mm, inside diameter of 9.35mm, length of 5.20m and three rows arraied staggered. Simulation results were such that refrigerant was super-heated state from the entrance to the 0.14m point, two-phase flow from the 0.14m point to the 4.10m point, sub-cooled state from the 4.10m point to the outlet. The degree of sub-cooled was $6.1^{\circ}C$. The variations of refrigerant quality, temperature, pressure, velocity, specific enthalpy, specific volume and air temperature, tube temperature were showed.

  • PDF

Design and Fabrication of 1 MVA Single Phase HTS Transformer for Power Distribution with Natural Convection Cooling System

  • Kim, W. S.;Kim, S. H.;Park, K. D.;H. G. Joo;G. W. Hong;J. H. Han;Park, J. H.;H. S. Son;S. Y. Hahn
    • Progress in Superconductivity
    • /
    • 제5권2호
    • /
    • pp.149-152
    • /
    • 2004
  • The design and the fabrication of a 1 MVA single-phase HTS transformer are presented in this paper, The rated voltages are 22.9 ㎸ for primary and 6.6 ㎸ for secondary, and the rated currents are 44 A and 152 A respectively. The transformer has HTS double pancake type windings. This type of winding has many advantages such as ease of fabrication and maintenance, good distribution of surge voltage and insulation of windings. Single HTS wire was used for primary winding and four HTS parallel wires were used for secondary winding. These windings are arranged reciprocally with the shell type iron core. An FRP cryostat with room temperature bore was fabricated to isolate the iron core from the coolant. The winding will be cooled down to 65 K with sub-cooled liquid nitrogen using a GM-cryocooler. The sub-cooled liquid nitrogen has advantages of good insulation because of no bubbles as well as increased current capacity of HTS wire.

  • PDF

초전도 전력케이블의 열 등가 회로에 관한 연구 (A Study on the Equivalent Thermal Circuit for HTS Power Cable)

  • 이수길;이흥재
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권1호
    • /
    • pp.61-65
    • /
    • 2010
  • To develop the thermal analysis method for the thermal behavior of HTS power cable system, cooled with sub-cooled liquid nitrogen, new thermo dynamic model for HTS cable system is introduced. The introduced thermal model is mainly modified from the thermal circuit following to IEC60287 for underground power cable systems such as XLPE or paper wrapped insulation cables. The thermal circuits for HTS cables are similar to the forced cooled underground cable system but the major thermal parameters and the configuration is apparently different to the normal cable systems so there has been no proposals in this field of analysing method. In this paper, 154kV HTS cable system has been introduced as an aspects of thermal models and a thermal circuit is proposed for the fundamentals on the dynamic rating systems for the HTS cable system. By using the thermal circuit developed in this paper, the optimal controls on the sub-cooling system's capacity become possible and it is expected to make the efficiency of HTS cable higher than conventional static controls.

CaO-Al2O3계 용융화합물의 물리·화학적 특성에 관한 연구 (Study on Physical and Chemical Properties of CaO-Al2O3 System Melting Compound)

  • 이근재;구자술;김진만;오상윤
    • 콘크리트학회논문집
    • /
    • 제25권2호
    • /
    • pp.209-215
    • /
    • 2013
  • 이 연구에서는 CaO-$Al_2O_3$계 급냉 제강슬래그(RCSS)의 물리 화학적 특성을 분석함으로써 친환경 무기 급결재로 활용방안을 모색하고자 하였다. RCSS의 성상은 섬유상과 구상으로 구별되었으며, 성상별로 CaO와 $Fe_2O_3$ 성분 함량이 반비례 경향을 나타냈다. 또한 CaO 함량이 낮아지고 $Fe_2O_3$ 함량이 증가함에 따라 강열감량은 (-)경향을 보였고 밀도는 증가하였다. 수은압입법에 의한 세공분포는 서냉 제강슬래그(SCSS)에 비해 매우 낮은 수치로 급냉에 의해 내부결함 및 미세기공률이 현저히 줄어든 것을 확인할 수 있었다. 급냉 제강슬래그를 구성하는 주요 광물을 분석하기 위해 XRD, f-CaO 정량, SEM-EDAX 분석을 실시한 결과에서 f-CaO의 존재는 관찰되지 않았으며, 구성성분이 주로 $C_{12}A_7$과 반응성 ${\beta}-C_2S$로 이루어져 있음을 확인할 수 있었다.

Design and dynamic simulation of a molten salt THS coupled to SFR

  • Areai Nuerlan;Jin Wang;Jun Yang;Zhongxiao Guo;Yizhe Liu
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1135-1144
    • /
    • 2024
  • With the increasing ratio of renewables in the grid, a low-carbon and stable base load source that also is capable of load tracking is in demand. Sodium cooled fast reactors (SFRs) coupled to thermal heat storage system (THS) is a strong candidate for the need. This research focuses on the designing and performance validation of a two-tank THS based on molten salt to integrate with a 280 MWth sodium cooled fast reactor. Designing of the THS includes the vital component, sodium-to-salt heat exchanger which is a technology gap that needs to be filled, and designing and parameter selection of the tanks and related pumps. Modeling of the designed THS is conducted followed by the description of operation strategies and control logics of the THS. Finally, the dynamic simulation of the designed THS is conducted based on Fortran. Results show, the proposed power system meets the need of the design requirements to store heat for 18 h during a day and provide 500 MWth for peak demand for the rest of the day.

Cryogenic cooling system for HTS cable

  • Yoshida, Shigeru
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권2호
    • /
    • pp.1-8
    • /
    • 2017
  • Recently, Research and development activity of HTS (High Temperature Superconducting) power application is very progressive worldwide. Especially, HTS cable system and HTSFCL (HTS Fault current limiter) system are proceeding to practical stages. In such system and equipment, cryogenic cooling system, which makes HTS equipment cooled lower than critical temperature, is one of crucial components. In this article, cryogenic cooling system for HTS application, mainly cable, is reviewed. Cryogenic cooling system can be categorized into conduction cooling system and immersion cooling system. In practical HTS power application area, immersion cooling system with sub-cooled liquid nitrogen is preferred. The immersion cooling system is besides grouped into open cycle system and closed cycle system. Turbo-Brayton refrigerator is a key component for closed cycle system. Those two cooling systems are focused in this article. And, each design and component of the cooling system is explained.

Fault Current Limiting Characteristic of Non-inductively Wound HTS Magnets in Sub-cooled $LN_2$ Cooling System

  • Park Dong-Keun;Ahn Min-Cheol;Yang Seong-Eun;Lee Chan-Joo;Seok Bok-Yeol;Yoon Yong-Soo;Ko Tae-Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권2호
    • /
    • pp.29-32
    • /
    • 2006
  • An advanced superconducting fault current limiter (SFCL) using $high-T_c$ superconducting (HTS) wire has been developed. The SFCL has a non-inductively wound magnet for reducing loss in normal state. Two types of non-inductively wound magnets, the solenoid type and the pancake type, were designed and manufactured by using Bi-2223 wire in this research. Short-circuit tests of the magnets were performed in sub-cooled $LN_2$ cooling system of 65 K. The magnets are thermally more stable and have a higher critical current in 65 K sub-cooled $LN_2$ cooling system than in 77 K saturated one. Because the resistivity of matrix at 65 K is lower than the resistivity at 77 K, the magnets generate a small resistance to reduce the fault current when the quench occurs. The magnets could limit the fault current to low current level with such a small resistance. The current limiting characteristic of the magnets was analyzed from the test result. The solenoid type was wound in parallel to make it non-inductive. The pancake type was also connected in parallel to be compared with the solenoid type in the same condition. The solenoid type was found to have a good thermal stability compared with the pancake type. It also had as large resistance as the pancake type to limit the fault current in sub-cooled $LN_2$ cooling system.