• 제목/요약/키워드: Strut height

검색결과 30건 처리시간 0.022초

꺽쇠형 강재 댐퍼의 록킹 거동 (Rocking Behavior of Clamped Shape Metallic Damper)

  • 이현호
    • 한국공간구조학회논문집
    • /
    • 제19권2호
    • /
    • pp.27-34
    • /
    • 2019
  • This study proposes a technique to dissipate the energy of a rocking wall installed on a frame by using a metallic damper. The rocking behavior is to turn left and right about the wall vertical axis. The development system is a method of dissipating energy by installing a damper which is the like on a large displacement portion. Experimental results showed that in case of shorter strut make strength capacity increasement and in case of longer strut make deformation capacity increasement. The higher the strut height, the better the energy dissipation capacity. The proposed equation for estimating the steel damper strength applied to this study is a straight type strut damper. However, it is not suitable for calculation of the strength of clamped type strut damper where both flexural behavior and shear behavior are mixed.

층고절감형 거더를 이용한 영구 스트러트 공법 (Strut as a Permanent System using Composite Beams)

  • 홍원기;박선치;김진민;이호찬
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.87-92
    • /
    • 2008
  • Sheathing work used for excavation in a crowded downtown is generally a temporary strut method using H-piles and sheathing wall includes lagging, CIP, SCW or slurry wall. A temporary strut serving the support for sheathing wall acts to resist the earth pressure, but it shall be removed when installing the underground structure members. A traditional temporary strut might cause the stress imbalance of the sheathing wall when it is demolished, resulting in time extension and the risk of collapse. A traditional temporary strut method thus needs to be improved for schedule and cost reduction, risk mitigation and for preparation for potential civic complaint. A permanent strut method doesn't require installing and demolishing the temporary structure that will lead to reducing the time and cost and the structural risk during the demolition process. And given the girder, the part of the underground structure, serves the role of strut, it can secure the wider interval compared to the traditional method, which enables to secure the wider space for the convenience of excavation as well as enhance the constructability and efficient site management. The thesis was intended to study the composite girder designed to use the strut as permanent structure so as to reduce the excavation and floor height.

건축구조물의 내진성능 향상을 위한 강재댐퍼 형상 및 이력 거동 (Metallic Damper Shape and Cyclic Behavior for the Seismic Capacity Improvement of Building Structures)

  • 이현호;김세일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권3호
    • /
    • pp.123-130
    • /
    • 2010
  • 본 논문에서는 기존 건축물의 내진성능을 향상시키기 위해 시공성과 설치 비용적인 측면에서 상대적으로 우수한 강재댐퍼를 대상으로 기존 개발된 장치와 새로 개발된 형상의 장치에 대한 평가를 해석적으로 수행하였다. 해석결과는 강도 및 에너지 소산능력으로 평가하였으며, 제안된 내력 산정식의 적용을 아울러 평가하였다. 연구대상 댐퍼의 스트럿 형상은 V형, S형이며, 댐퍼의 스트럿 높이와 각도를 주요 변수로 한 후 ABAQUS를 이용하여 유한요소 해석하였다. 해석은 최대변위를 50mm로 하고 점진적인 이력변위곡선을 적용하여 수행하였다. 항복강도, 최대강도, 에너지 소산능력 평가결과, V형 및 S형 모두 우수한 성능을 보유한 것으로 평가되었으며, 또한 스트럿 각도 $60^{\circ}$ 및 높이 140, 200 mm의 성능이 안정적인 것으로 평가되었다. 전체적으로는 S형의 응답이 V형보다 안정적인 것으로 평가되어, S형 강재댐퍼의 적용성이 V형보다 유리한 것으로 평가되었다.

V형 강재댐퍼의 이력특성 평가 (Evaluation on Hysteretic Behaviors of V Shaped Metallic Dampers)

  • 이현호;김세일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.254-262
    • /
    • 2011
  • 본 연구의 목적은 슬릿형 강재댐퍼보다 에너지 소산능력 등이 우수할 것으로 예상되는 V형 강재 댐퍼 개발에 있다. 이를 위하여 댐퍼 스트럿의 높이 및 각도에 대한 실험체 9개를 만들어 전단실험을 수행하였다. 실험결과, 스트럿 높이가 270mm이고, 스트럿 각도 $60^{\circ}$인 경우의 V형 강재댐퍼가 가장 우수한 내진성능 보유한 것으로 평가되었다. 또한 기존내력식을 이용한 댐퍼의 항복강도를 비교한 결과, 기존 실험결과를 분석한 범위 내에서 V형 댐퍼의 실험결과가 높게 평가되는 것으로 나타났다.

강재 댐퍼의 스트럿 형상과 높이에 따른 록킹 거동 (Rocking Behavior of Steel Dampers according to Strut Shapes and Heights of Steel dampers)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권4호
    • /
    • pp.45-52
    • /
    • 2019
  • 본 연구에서는 벽체의 록킹 거동을 고려한 내진보강 기법을 개발하였다. 록킹 거동은 벽체 수직 축을 중심으로 좌우로 회전하는 것으로, 개발 시스템은 변위 큰 부분에 댐퍼 등을 설치하여 에너지를 소산 시키는 방법이다. 댐퍼는 강재댐퍼를 사용하였으며, 스트럿 형상 및 높이를 변수로 선정하였다. 실험결과 스트럿 높이가 짧을수록 강도 능력이, 길수록 변형능력이 우수한 것으로 평가되었다. I형과 S형 스트럿 능력을 평가한 결과, S형이 우수한 내진 성능을 보유한 것으로 평가되었다.

Cyclic loading test of abnormal joints in SRC frame-bent main building structure

  • Wang, Bo;Cao, Guorong;Yang, Ke;Dai, Huijuan;Qin, Chaogang
    • Earthquakes and Structures
    • /
    • 제20권4호
    • /
    • pp.417-430
    • /
    • 2021
  • Due to functional requirements, SRC column-RC beam abnormal joints with characteristics of strong beam weak column, variable column section, unequal beam height and staggered height exist in the Steel reinforced concrete (SRC) frame-bent main building structure of thermal power plant (TPP). This paper presents the experimental results of these abnormal joints through cyclic loading tests on five specimens with scaling factor of 1/5. The staggered height and whether adding H-shaped steel in beam or not were changing parameters of specimens. The failure patterns, bearing capacity, energy dissipation and ductile performance were analyzed. In addition, the stress mechanism of the abnormal joint was discussed based on the diagonal strut model. The research results showed that the abnormal exterior joints occurred shear failure and column end hinge flexural failure; reducing beam height through adding H-shaped steel in the beam of abnormal exterior joint could improve the crack resistance and ductility; the abnormal interior joints with different staggered heights occurred column ends flexural failure; the joint with larger staggered height had the higher bearing capacity and stiffness, but lower ductility. The concrete compression strut mechanism is still applicable to the abnormal joints in TPP, but it is affected by the abnormal characteristics.

슬릿형상에 따른 강재댐퍼의 이력거동 (Hysteretic Behaviors of Metallic Dampers with the Various Slit Shape)

  • 이현호;김세일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권5호
    • /
    • pp.199-208
    • /
    • 2011
  • 본 연구의 목적은 강재댐퍼 면내에 형성되는 슬릿 형상이 댐퍼의 강도 및 변형 능력에 미치는 영향을 평가하는데 있다. 이를 위하여 댐퍼 스트럿의 높이 및 각도에 대한 실험체 12개를 만들어 전단실험을 수행하였다. 분석결과, 댐퍼의 초기강성, 항복강도 및 항복 후 2차강성의 크기를 고려할 때 스트럿 높이가 200mm이고, 스트럿 각도 $60^{\circ}$인 S형 강재댐퍼의 내진성능이 가장 우수한 것으로 평가되었다. 또한 기존내력식을 이용한 댐퍼의 항복강도 비교결과, 내력식의 결과보다 실험 결과값이 크게 나와 댐퍼의 항복강도는 스트럿높이, 스트럿각도 등의 크기정도에 지배 받는 것으로 나타났다.

단부에 설비덕트를 포함하는 새로운 더블티 전단실험II (Shear Test II on New Modified Double Tee Slabs including Service Ducts at the Ends)

  • 김연수;유정욱;이보경;유승룡
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.267-270
    • /
    • 2005
  • The section of double-tee is considered as one of the most efficient type for flexure. However, the depth of it is bigger then that of other slab systems. The story height of it is also increased because the duct space is required under the double tee in addition to their net depth. Thus, a new modified double-tees with the nib length of 1.58m was suggested in this study. The story height of this one is reduced up to 450mm by including duct space under the nib at the ends of slab. The four ends of the modified two single tees were designed by strut-tie models. Shear tests were performed on them to verify the safety. The ultimate shear strengths of non-prestressed two specimens were larger than the design shear strength by strut-tie models. They were failed in ductile with many distributed flexural crackings. However, the other prestressed two specimens showed much stiffer behaviors, less deflection. and strength than those of prestressed.

  • PDF

구조물 겸용 흙막이 스트러트 공법의 개선 연구 (A Study on the Technological Improvement of Strut as a Permanent Structure)

  • 김선국;홍원기
    • 한국건설관리학회논문집
    • /
    • 제9권5호
    • /
    • pp.186-193
    • /
    • 2008
  • 흙막이를 지지하는 버팀대를 가설재가 아닌 주(主)구조체로 이용하는 SPS(Strut as a Permanent System) 공법이 개발되어 최근 국내 공사현장에서 활발하게 활용되고 있다. 이 공법은 건축공사 현장에서 원가절감, 공기단축, 구조적 안정성 향상, 건설환경 개선 등 다양한 이점을 주는 반면 지하층고의 증가와 철골부위 내화피복을 추가로 수행하여야 하는 문제점이 있다. 지하층고의 증가는 흙막이 깊이 및 지하 최저부위 굴착량 증가의 문제점을 유발하고, 내화피복 공사는 공사환경을 열악하게 함은 물론 공사비 증대의 요인이 된다. 따라서 본 연구는 SPS 공법의 문제점을 개선한 모듈화된 철골철근 복합 구조시스템(modularized hybrid structure system)을 제안하는 것을 목적으로 한다. 제안된 공법은 구성원리와 함께 실험을 통하여 구조적 성능을 검증되고 다양한 공사조건을 만족시키는 시공성능이 분석된다.

철골철근콘크리트 기둥-철골 보 접합부의 유효폭에 관한 실험적 연구 (Experimental Study on the Effective Joint Width of the SRC Column-Steel Beam Joint)

  • 연선아;김승훈;서수연;이리형;홍원기
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.405-410
    • /
    • 2001
  • To investigate factors influencing the effective width of. SRC column-steel beam joint resisting the moment as strut, six specimens are designed and tested. Parameters in the test are column width, beam height and horizontal tie within beam depth. From the test, using either wide column width or ties, strength and stiffness of joint were developed. The lower beam height the specimens showed the lower moment.

  • PDF