• 제목/요약/키워드: Structure-borne-noise

검색결과 239건 처리시간 0.032초

철도차량 구조기인 소음의 저감에 관한 연구 (A Study on the Reduction of Structure-borne Noise in a Train)

  • 우관제;김석현
    • 한국철도학회논문집
    • /
    • 제11권6호
    • /
    • pp.519-523
    • /
    • 2008
  • 철도차량의 실내소음은 공기기인 소음과 구조기인 소음이 더해진 것이다. 본 논문에서는 개활지 주행중 실내소음을 지배한다고 알려져 있는 구조기인 소음에 대해 연구하였다. 구조기인 소음을 진동원, 전달경로 및 소음 발생부로 구분하여 실내소음을 줄이기 위한 방안에 대해 연구하였다.

앤티롤바의 취부위치에 따른 철도차량의 실내소음에 대한 연구 (The study of the effects to the structure borne noise in terms of the Anti-Roll Bar's mounting position)

  • 박희준;우관제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1794-1798
    • /
    • 2008
  • Inside noise level of a running train in open field is the summation of air borne noise and structure-borne noise. Anti-roll bar is the major transmission path of vibration from bogie. And this vibration gives an effect to the structure borne noise. In this paper, the effect of anti-roll bar is investigated. Structure borne noise is analyzed in terms of changing the mounting position of anti-roll bar to reduce inside noise levels.

  • PDF

Structural noise mitigation for viaduct box girder using acoustic modal contribution analysis

  • Liu, Linya;Qin, Jialiang;Zhou, Yun-Lai;Xi, Rui;Peng, Siyuan
    • Structural Engineering and Mechanics
    • /
    • 제72권4호
    • /
    • pp.421-432
    • /
    • 2019
  • In high-speed railway (HSR) system, the structure-borne noise inside viaduct at low frequency has been extensively investigated for its mitigation as a research hotspot owing to its harm to the nearby residents. This study proposed a novel acoustic optimization method for declining the structure-borne noise in viaduct-like structures by separating the acoustic contribution of each structural component in the measured acoustic field. The structural vibration and related acoustic sourcing, propagation, and radiation characteristics for the viaduct box girder under passing vehicle loading are studied by incorporating Finite Element Method (FEM) with Modal Acoustic Vector (MAV) analysis. Based on the Modal Acoustic Transfer Vector (MATV), the structural vibration mode that contributes maximum to the structure-borne noise shall be hereinafter filtered for the acoustic radiation. With vibration mode shapes, the locations of maximum amplitudes for being ribbed to mitigate the structure-borne noise are then obtained, and the structure-borne noise mitigation performance shall be eventually analyzed regarding to the ribbing conduction. The results demonstrate that the structural vibration and structure-borne noise of the viaduct box girder mainly occupy both in the range within 100 Hz, and the dominant frequency bands both are [31.5, 80] Hz. The peak frequency for the structure-borne noise of the viaduct box girder is mainly caused by $16^{th}$ and $62^{th}$ vibration modes; these two mode shapes mainly reflect the local vibration of the wing plate and top plate. By introducing web plate at the maximum amplitude of main mode shapes that contribute most to the acoustic modal contribution factors, the acoustic pressure peaks at the field-testing points are hereinafter obviously declined, this implies that the structure-borne noise mitigation performance is relatively promising for the viaduct.

함정용 펌프류 장비의 고체음저감 (Structure-borne Noise Reduction of Pump Machineries for Naval Ships)

  • 김현실;김재승;강현주;김상렬
    • 연구논문집
    • /
    • 통권29호
    • /
    • pp.83-90
    • /
    • 1999
  • In naval ships, pump machineries are the major sources of airborne and structure-borne noise. Noise is critical issue in ships not only it causes annoyance to crews, but also it can increase the underwater radiated noise, which is crucial in anti-submarine warfare. In present study, it is discussed the reduction of structure-borne noise of pump machineries by showing several examples. The most typical and effective solution is to use double resilient mount system. However, in cases where double resilient system cannot be applied due to space and weight increase, rubber pad can be used to reduce the structure-borne noise. In principle, the concept of structure-borne noise reduction is the same as that of vibration isolation.

  • PDF

PROCESS OF DESIGNING BODY STRUCTURES FOR THE REDUCTION OF REAR SEAT NOISE IN PASSENGER CAR

  • Kim, K.C.;Kim, C.M.
    • International Journal of Automotive Technology
    • /
    • 제8권1호
    • /
    • pp.67-73
    • /
    • 2007
  • This study analyzes the interior noise that is generated during acceleration of a passenger car in terms of car body structure and panel contribution. According to the transfer method, interior noise is classified into structure-borne noise and air-borne noise. Structure-borne noise is generated when the engine's vibration energy, an excitation source, is transferred to the car body through the engine mount and the driving system and the panel of the car body vibrates. When structure-borne noise resonates in the acoustic cavity of the car interior, acute booming noise is generated. This study describes plans for improving the car body structure and the panel form through a cause analysis of frequency ranges where the sound pressure level of the rear seat relative to the front seat is high. To this end, an analysis of the correlation between body attachment stiffness and acoustic sensitivity as well as a panel sensitive component analysis were conducted through a structural sound field coupled analysis. Through this study, via research on improving the car body structure in terms of reducing rear seat noise, stable performance improvement and light weight design before the proto-car stage can be realized. Reduction of the development period and test car stage is also anticipated.

Study on Noise Reduction of AV Projector

  • Kim, Sang-Hoon;Bok, Ki-So;Lee, Seung-Gyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1155-1158
    • /
    • 2007
  • To reduce acoustic noise level of an AV projector, primary noise sources of AV projector were analyzed. Based on the analyzed result, methods to control each source are presented and tried. Structure-borne noise can be controlled by anti vibration design of mounting system, and air-borne noise by reducing flow resisitvity.

  • PDF

배수관의 구조소음과 소음저감에 관한 연구 (A Study on the Structure-borne Noise and Noise Reduction of Drainage Pipes)

  • 류봉조;이규섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.194-202
    • /
    • 2009
  • The paper deals with the countermeasure against structure-borne noise source and noise reduction of drainage pipes. Recently, the problem the problem of the toilet drain noise of an apartment house has been become the center of public interest and a target of public grievance. Generally, the drain noise of a toilet in the apartment house has a pink noise characteristics below 2 kHz level, and therefore, the structure-borne noise has a great effect on the entire drain noise. In order to measure the transmission loss for various kinds of pipes such as PVC pipes, cast-iron pipes and newly developed AS pipes, experimental setup containing speakers as a sound source was designed and manufactured. The second-stories measurement room with a small size anechoic chamber was constructed and the noise level for different kinds of drainage pipes was measured by the sound level meter. Through the experimental research in the study, noise reduction capacity for various kinds of drainage pipes and countermeasures against structure-borne noise source are demonstrated.

  • PDF

전자장비 구조기인소음 저감방안의 실험적 검토 (An Experimental Analysis of the Structure-Borne Noise Reduction on Electrical Equipment)

  • 이성현;서윤호;김원형;최영철
    • 한국음향학회지
    • /
    • 제33권2호
    • /
    • pp.111-117
    • /
    • 2014
  • 본 논문은 전자장비의 구조기인소음 (structure-borne noise)의 실험적 저감방안 검토에 대한 내용을 다루었다. 수냉식 전자장비의 유일한 소음원인 냉각장치를 목업(mock-up)으로 제작하여 소음 특성을 파악하였으며, 전원에 의한 영향, 구조체 강성에 의한 영향, 팬 고정부위의 절연에 의한 효과, 마운트의 공진주파수가 미치는 영향 등에 대한 검토를 수행하였다. 이를 반영하여 제작된 전자장비 프로토타입의 소음 특성을 파악하였으며, 구조기인소음을 저감시키기 위하여 작동회전수(rpm) 조합, 마운트 종류 및 설치방법 등에 대하여 검토하였다. 냉각팬 작동 주파수의 1차, 4차 성분에 의하여 소음이 크게 발생하며, 구조체 강성증가, 팬 고정부위 절연, 마운트 공진주파수 저하, 작동회전수조합, 마운트 선정방법 등에 의하여 전자장비의 구조소음을 저감시킬 수 있음을 확인하였다.

함정탑재 펌프류 장비의 공기음/고체음 저감 사례 연구 (Case study on the reduction of airborne and structure-borne noise of a shipboard pump)

  • 김상렬;김현실;김봉기;김재승;강현주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.411-415
    • /
    • 2007
  • The reduction of airborne and structure-borne noise of a shipboard pump for a navel ship is very important because the noise levels of the pump must not exceed criteria such as MIL-STD. In this paper, several practical examples of reducing the noise levels are presented. The examples show that the inadequate rotor-balancing and shaft-alignment results in the increase of the structure-borne noise on all lower mounts. It is also found that the unequal loading on mounts can cause the dramatically increasing the noise levels on certain local positions. Since the piping system arrangement such as valve location, flexible joint, and elbow location affects on the noise measurement, care must be taken to minimize the unnecessary noise from the piping system.

  • PDF

SEA법에 의한 선박고체소음의 전파경로에 대한 해석적 연구 (A Study on the Transmission Path of Shipboard Structure-Borne Noise-Using SAE)

  • 현명환;김사수
    • 소음진동
    • /
    • 제6권5호
    • /
    • pp.575-585
    • /
    • 1996
  • In order to build a quiet and comfortable ship, the noise levels on board ship must be predicted at early design stage. Statistical Energy Analysis (SEA) developed by R. H. Lyon has been well known to be the most useful frame work to study the energy flow of noise and vibration in structure. This paper applied this theory to predict the transmission loss of structure-borne noise of model structure and has developed computer program. Components constructions model structure have been all considered as SEA elements. And we also estimated the SEA parameters from the model structure. Using SEA and a new conception of STL, we found the transimission character of structure-borne noise theoretically by the idealized ship model, and then compared the results with three cases.

  • PDF