• Title/Summary/Keyword: Structure vibration

Search Result 4,325, Processing Time 0.03 seconds

Effective Arrangement of Non-explosive Demolition Agents and Empty Holes for Improving Fragmentation of Square Concrete Structures (정사각형 콘크리트 구조물의 파쇄도 향상을 위한 비폭성 파쇄제와 천공 홀의 효과적인 배치)

  • Cho, Hwangki;Nam, Yunmin;Kim, Kyeongjin;Lee, Jaeha;Sohn, Dongwoo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.2
    • /
    • pp.145-151
    • /
    • 2017
  • As an alternative to conventional explosive methods for demolition of concrete structures and rocks, the use of non-explosive demolition agents can be considered to reduce noise, vibration, and dust emissions during the demolition process. In this study, we conduct finite element analysis for crack initiation and propagation caused by the expansion of non-explosive demolition agents in square concrete structures. The predicted crack patterns are compared with the experimental results in the literature. The minimum values of the required expansion pressure of non-explosive demolition agents are also estimated, which depend upon the arrangement of non-explosive demolition agents and empty holes. Furthermore, we investigate the effect of empty holes on the fragmentation of concrete structures, and discuss the effective arrangement of non-explosive demolition agents and empty holes for fragmentation improvement.

Dynamic Characteristics of Reinforced Concrete Axisymmetric Shell with Initial Imperfection (초기결함을 갖는 철근 콘크리트 축대칭 쉘의 동적 특성 -돔의 결함의 영향을 중심으로-)

  • 조진구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.4
    • /
    • pp.77-85
    • /
    • 1999
  • In this study, a computer program considering initial imperfection of axisymmetric reinforced concrete shell which plastic deformation by large external loading was developed . Initial imperfection of dome was assumed as 'dimple type' which can be expressed as Wi=(Wo/h)(1-x$^2$)$^3$. The developed model applied to the analysis of dynamic response of axisymmetric reinforced concrete shell when it has initial imperfection. The initial imperfection of 0.0, -5.0, and 5cm and steel and steel layer ratio 0,3, and 5% were tested for numerical examples . The results can be summarized as follows ; 1. Dynmaic response of vertical deflection at dome crown showed slow increased if it has not inital imperfection . But the response showed relatively high amplitude when initial imperfection was inner directed (opposite direction to loading). Similar trends also appeared for different steel layer ratios. 2. Dynamic responses of radial displacement at the junction of dome and wall showed the highest amplitude when initial imperfection was inward directed (opposite direction to loading). The lowest amplitude occurred when initial imperfection was outward directed (same direction to loading). Vibration period also delayed for inward directed initial imperfection . These trends were obvious as steel layer ratio increasing. 3. The effects of imperfection for the dynamic response of radial displacement a the center of wall scarely appeared. The effects of initial imperfection of dome on the dynmaic response of the wall can be neglected. 4. Effect of steel on the dynmic response of axisymmetric shell structure was great when initial imperfection did not exist. And the effect of direction of initial imperfection (inward or outward) did not show big difference.

  • PDF

Blasting Standardization works for NATM on the Seoul Subway Construction by Dr, Ginn Huh (서울 지하철공사 발파공법의 표준화)

  • Heo, Jin
    • Journal of the Korean Professional Engineers Association
    • /
    • v.16 no.3
    • /
    • pp.5-23
    • /
    • 1983
  • On the Seoul Metropolitan Subway Construction of No. 3, 4 Line, the total length is 57 Km and it is now undergoing almost 55% progress. The working method is classified into Open Cut of 70% and the rest of 30% tunnelling method in the 48 job site. Above tunnelling method is execute by American Steel Support System and the rest of 10 job site carried out by New Austria Tunnelling Method. This paper describes Blasting Standardizations works on the above Tunnelling ' Open Cut Method under big slogan, first safety, second execution. As a superintendent, I strived standardization of works with Better powder, Better Drills ' Better Pattern. Geological structure of Seoul area is composed by Jurassic Granite and also the above rockgroup are over burden by Alluviums as a Unconformity. First of all, I carried out the standard amount of powder and burden through experimental standard blasting by each powder as following Blasting works in the subway construction is surrounding shop Building, under pass the city river and also under pass highest building basement floor. I made allowable Blasting Vibration Value by West-Germany Vornorm DIN 4150, Teil 3 and should measure each blasting works as fellows all of powder is used basically Low-Gravity and Low Velocity such as Slurry, Ammonium Nitrate ' Finex I, II. for Smooth Blasting Instead of Gelatin Dynamite. Electric Detonation Cap is used basically M/S Delay Cup instead of Electric delay ' Simultaneous cap. I applied following formula V=KW3/4 $D^{-2}$ V=Particle Velocity (Cm/sec) K=Ginh Huh's Value W=Delay Charge (Kg) D=Distance(m) In the Open Cut, within 1m distance from H-pile I made to use the Concrete breaker, as following V=7W/$^{0.5}$V/$^{-1.75}$ On the Concentrate Building area, I advise to use Light class drill ø36m Bit and advance 1.1m per round blasting the three boom jumbo drill over ø45mm used only suburb of city.e Light class drill ø36m Bit and advance 1.1m per round blasting the three boom jumbo drill over ø45mm used only suburb of city.

  • PDF

Vibration of Rectangular Plates (직사각형판(直四角形板)의 진동해석(振動解析))

  • Keuck-Chun,Kim;Tae-Young,Chung
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 1977
  • The major objects of this report are to supplement data of natural frequencies of thin elastic rectangular plates to the available data, and to give an experimental verification for natural frequencies obtained by Rayleigh-Ritz method, the generation set of which are eigenfunctions of Euler beams. For the first object the following five models, for which data only for the fundamental mode or data only for square plates are available, are adopted; (1) two opposed edges are clamped and the other two opposed edges simply supported (C-C, S-S), (2) one edge is simply supported and the other three edges clamped (C-C, C-S), (3) one edge is free and the other three edges clamped (C-C, C-F), (4) two adjacent edges are clamped and the other two adjacent edges free (C-F, C-F). For the (C-C, S-S) model the frequency equation obtained with the mode shapes assumed as of a single trigonometric series is solved. And for the other four models Rayleigh-Ritz method taking eigenfunctions of Euler beams as the generating set is applied. The numerical examples are obtained up to the fourth, the fifth or the sixth order depending on the range of the aspect ratio (0.1-10.0). The number of terms in the generating set for Rayleigh-Ritz method is fifteen for all models. For the experiment three models made of 3.2mm thickness mild steel plate for general structure use were prepared in following size; $300mm{\times}600mm,\;600mm{\times}600mm\;and\;900mm{\times}600mm$. Their boundary conditions are made to fit (C-C, C-F) condition. From the experiment mechanical impedance curves based on the frequency response method were obtained together with phase relation diagrams. The experimental data are resulted in good conformity to calculated values.

  • PDF

Hydroelastic Vibration Analysis of Three Dimensional Submerged Structure (3차원 접수구조물의 유체탄성 진동해석)

  • 정기태;강호승;김영복
    • Computational Structural Engineering
    • /
    • v.4 no.1
    • /
    • pp.20-27
    • /
    • 1991
  • 본 논문에서는 유체-구조 상호작용해석의 일종의 3차원 접수구조물의 진동해석을 효과적으로 수행하기 위한 해석방법을 제시하기 위하여 동적재해석기법을 검토하였다. 접수구조물의 유한구조 상호작용해석 결과는 구조진동의 관심 주파수역에서는 3차원 연성 부가수질량으로 표현되는 관성력으로 나타난다. 따라서 구조질량행렬에 부가수질량 행렬이 더해져서 전체 관성력으로 표현된다. 이 부가수질량을 추가질량으로 보고 재해석기법을 응용하는 방법을 수치실험을 통해 검증하였다. 이 때 재해석기법이 갖추어야 할 조건은 원구조의 질량과 거의 같은 정도의 질량이 추가되고 또한 완전 연성질량이 추가된 경우에도 정확한 해를 주어야 한다는 것이다. 이를 검증하기 위해 직접재해석기법과 섭동법을 이용한 재해석기법으로 4질량 스프링지지구조에 대한 해석을 수행한 결과 직접재해석기법의 응용이 적합함을 쉽게 입증할 수 있었다. 접수구조물의 예로는 3차원 잠수주상체에 대해 접수진동해석을 수행하였으며 그 결과 선체진동해석에 전통적으로 이용되고 있는 2차원 부가수질량과 3차원 수정계수를 사용한 기준차수법에서는 수지모드와 수평-비틔 연성모드와 같이 서로 독립적인 모드에 대해서는 따로 진동해석을 수행해 주어야 하는 단점이 발견되었다. 이 단점을 보완한 각 모드의 3차원 수정계수행렬을 이용한 재해석기법을 도입하여 모드에 상관없이 동시에 해를 구할 수 있었다. 그러나, 이 방법은 3차원 수정계수가 구해져 있는 경우에 한해서만 적용가능하며 실제 선체진동의 경우에는 10Hz 미만의 저차 주선체 진동에 한해서만 적용가능한 방법이다. 고차의 진도옴드에는 3차원 수정계수를 구할 수 없기 때문에 유체-구조 상호작용 해석결과로부터 얻은 3차원 연성 부가수질량을 이용하게 되며 이 때 이 행렬이 접수구조 표면의 전 자유도와 연성되어 있기 때문에 방대한 방정식을 푸어야 하지만 직접재해석기법을 적용함으로써 정확한 해를 구할 수 있었다. 또한 3차원 부가수질량을 이용한 직접재해석기법은 종래의 2차원 부가수질량과 3차원 수정계수를 이용한 방법에 비해 해석시간 면에서도 전혀 불리한 점이 없는 경제적 방법임이 밝혀졌다. 앞으로 Slamming 혹은 수중폭파 등의 충격하중에 의한 천이 구조응답 해석을 위한 효과적인 방법에 대해서도 연구결과를 발표할 계획이다.

  • PDF

Seismic Fragility Analysis of a FCM Bridge Considering Soil Properties (지반특성을 고려한 FCM 교량의 지진취약도 분석)

  • Kim, Jae-Cheon;Byeon, Ji-Seok;Shin, Soo-Bong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.37-44
    • /
    • 2008
  • This study investigates the influence of various soil properties on the seismic performance of a three-span FCM bridge. Piers that are vulnerable to seismic vibration are identified through numerical study of plastic hinges possibly occurring at the top and bottom of the piers. The fragility curve is obtained as a lognormal distribution function with respect to peak ground acceleration(PGA). The median and logarithmic standard deviation, which are two parameters of a lognormal distribution function, are estimated using the maximum likelihood method. In order to consider the different soil properties of each support, an equivalent spring based on the Korean Standard Specifications for Highway Bridges(KSSHB) is adopted in this study. For seismic fragility analysis, the rotational ductility demands of bridge piers are used as a damage index of the structure.

Assessment of modal parameters considering measurement and modeling errors

  • Huang, Qindan;Gardoni, Paolo;Hurlebaus, Stefan
    • Smart Structures and Systems
    • /
    • v.15 no.3
    • /
    • pp.717-733
    • /
    • 2015
  • Modal parameters of a structure are commonly used quantities for system identification and damage detection. With a limited number of studies on the statistics assessment of modal parameters, this paper presents procedures to properly account for the uncertainties present in the process of extracting modal parameters. Particularly, this paper focuses on how to deal with the measurement error in an ambient vibration test and the modeling error resulting from a modal parameter extraction process. A bootstrap approach is adopted, when an ensemble of a limited number of noised time-history response recordings is available. To estimate the modeling error associated with the extraction process, a model prediction expansion approach is adopted where the modeling error is considered as an "adjustment" to the prediction obtained from the extraction process. The proposed procedures can be further incorporated into the probabilistic analysis of applications where the modal parameters are used. This study considers the effects of the measurement and modeling errors and can provide guidance in allocating resources to improve the estimation accuracy of the modal data. As an illustration, the proposed procedures are applied to extract the modal data of a damaged beam, and the extracted modal data are used to detect potential damage locations using a damage detection method. It is shown that the variability in the modal parameters can be considered to be quite low due to the measurement and modeling errors; however, this low variability has a significant impact on the damage detection results for the studied beam.

Base isolation performance of a cone-type friction pendulum bearing system

  • Jeon, Bub-Gyu;Chang, Sung-Jin;Kim, Sung-Wan;Kim, Nam-Sik
    • Structural Engineering and Mechanics
    • /
    • v.53 no.2
    • /
    • pp.227-248
    • /
    • 2015
  • A CFPBS (Cone-type Friction Pendulum Bearing System) was developed to control the acceleration delivered to a structure to prevent the damage and degradation of critical communication equipment during earthquakes. This study evaluated the isolation performance of the CFPBS by numerical analysis. The CFPBS was manufactured in the shape of a cone differenced with the existing FPS (Friction Pendulum System), and a pattern was engraved on the friction surface. The natural frequencies of the CFPBS were evaluated from a free-vibration test with a seismic isolator system consisting of 4 CFPBS. To confirm the earthquake-resistant performance, a numerical analysis program was prepared using the equation of the CFPBS induced from the equations of motion. The equation reported by Tsai for the rolling-type seismic isolation bearings was proposed to design the equation of the CFPBS. Artificial seismic waves that satisfy the maximum earthquake scale of the Korean Building Code-Structural (KBC-2005) were created and verified to review the earthquake-resistant performance of the CFPBS by numerical analysis. The superstructural mass of the CFPBS and the skew angle of friction surface were considered for numerical analysis with El Centro NS, Kobe NS and artificial seismic waves. The CFPBS isolation performance evaluation was based on the numerical analysis results, and comparative analysis was performed between the results from numerical analysis and simplified theoretical equation under the same conditions. The validity of numerical analysis was verified from the shaking table test.

Statistical characteristics of sustained wind environment for a long-span bridge based on long-term field measurement data

  • Ding, Youliang;Zhou, Guangdong;Li, Aiqun;Deng, Yang
    • Wind and Structures
    • /
    • v.17 no.1
    • /
    • pp.43-68
    • /
    • 2013
  • The fluctuating wind induced vibration is one of the most important factors which has been taken into account in the design of long-span bridge due to the low stiffness and low natural frequency. Field measurement characteristics of sustained wind on structure site can provide accurate wind load parameters for wind field simulation and structural wind resistance design. As a suspension bridge with 1490 m main span, the Runyang Suspension Bridge (RSB) has high sensitivity to fluctuating wind. The simultaneous and continuously wind environment field measurement both in mid-span and on tower top is executed from 2005 up to now by the structural health monitoring system installed on this bridge. Based on the recorded data, the wind characteristic parameters, including mean wind speed, wind direction, the turbulence intensity, the gust factors, the turbulence integral length, power spectrum and spatial correlation, are analyzed in detail and the coherence functions of those parameters are evaluated using statistical method in this paper. The results indicate that, the turbulence component of sustain wind is larger than extremely strong winds although its mean wind speed is smaller; the correlation between turbulence parameters is obvious; the power spectrum is special and not accord with the Simiu spectrum and von Karman spectrum. Results obtained in this study can be used to evaluate the long term reliability of the Runyang Suspension Bridge and provide reference values for wind resistant design of other structures in this region.

Control of the along-wind response of steel framed buildings by using viscoelastic or friction dampers

  • Mazza, Fabio;Vulcano, Alfonso
    • Wind and Structures
    • /
    • v.10 no.3
    • /
    • pp.233-247
    • /
    • 2007
  • The insertion of steel braces has become a common technique to limit the deformability of steel framed buildings subjected to wind loads. However, when this technique is inadequate to keep floor accelerations within acceptable levels of human comfort, dampers placed in series with the steel braces can be adopted. To check the effectiveness of braces equipped with viscoelastic (VEDs) or friction dampers (FRDs), a numerical investigation is carried out focusing attention on a three-bay fifteen-storey steel framed building with K-braces. More precisely, three alternative structural solutions are examined for the purpose of controlling wind-induced vibrations: the insertion of additional diagonal braces; the insertion of additional diagonal braces equipped with dampers; the insertion of both additional diagonal braces and dampers supported by the existing K-braces. Additional braces and dampers are designed according to a simplified procedure based on a proportional stiffness criterion. A dynamic analysis is carried out in the time domain using a step-by-step initial-stress-like iterative procedure. Along-wind loads are considered at each storey assuming the time histories of the wind velocity, for a return period $T_r=5$ years, according to an equivalent wind spectrum technique. The behaviour of the structural members, except dampers, is assumed linear elastic. A VED and an FRD are idealized by a six-element generalized model and a bilinear (rigid-plastic) model, respectively. The results show that the structure with damped additional braces can be considered, among those examined, the most effective to control vibrations due to wind, particularly the floor accelerations. Moreover, once the stiffness of the additional braces is selected, the VEDs are slightly more efficient than the FRDs, because they, unlike the FRDs, dissipate energy also for small amplitude vibrations.