• Title/Summary/Keyword: Structural test facility

Search Result 99, Processing Time 0.028 seconds

전기체 구조시험 설비 감시 시스템

  • Chae, Dong-Chul;Hwang, Gui-Chul;Song, Jae-Chang;Shim, Jae-Yeul
    • Aerospace Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.29-34
    • /
    • 2003
  • Full-scale test facility is a huge system which is integrated by many subsystems. There are several critical elements in test facility system. Those elements may cause undesirably test article failure during testing. Therefore, test facility monitoring system which indicates the operating status of the critical elements is required for performing full-scale structural test. Selection of critical element and design of this monitoring system are explained in detail in this paper. The monitoring system developed are being applied to T-50 full-scale static test, will be expended for full-scale fatigue test in the near future.

  • PDF

STRUCTURAL INTEGRITY EVALUATION OF NUCLEAR FUEL WITH REDUCED WELDING CONDITIONS

  • Park, Nam-Gyu;Park, Joon-Kyoo;Suh, Jung-Min;Kim, Kyu-Tae;Jeon, Kyeong-Lak
    • Nuclear Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.347-354
    • /
    • 2009
  • Welding is required for a connection between two different components in the nuclear fuel of a pressurized water reactor. This work relies on a mechanical experiment and analytic results to investigate the structural integrity of nuclear fuel in a situation where some components are not welded to each other. A series of lateral vibration tests are performed in a test facility, and the test structures are examined in terms of dynamic behavior. In the tests, the displacement signal at every grid structure that sustains fuel rods is measured and processed to identify the dynamic properties. The fluid-elastic stability of the structure is also analyzed to evaluate susceptibility to a cross flow with an assumed conservative cross flow distribution. The test and analysis results confirm that the structural integrity can be maintained even in the absence of some welding connections.

Flow Analysis of Simulation Nuclear Fuel Loaded in the HANARO Flow Simulation Test Facility (하나로 유동모의 시험장치에 설치되는 모의 핵연료 유동해석)

  • Park Yong-Chul;Cho Yeong-Garp;Wu Jong-Sub
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.43-46
    • /
    • 2002
  • The HANARO, multi-purpose research reactor, 30 MWth open-tank-in-pool type, is under 24 MWth of power operation since it reached to the initial critical in February, 1995. Many useful experiments should be safely performed to activate the utilization of the HANARO, but there is a radioactive risk of using the HANARO. To reduce the risk, a test facility, which is not reacted by nuclear fuel, is being developed to simulate similar flow characteristics with the HANARO. This paper describes the computational flow analysis to determine each shape of simulating fuels for simulating the flow similarities of 36 elements hexagonal fuels assembly and 18 elements circulating fuels assembly loaded in HANARO. The shares of orifices were determined by the trial and error method and the structural integrities of them were verified by the finite element method assuming that the flow rate and pressure differences of reactor core are constant. The analysis results will be verified with the results of the flow test to be performed after the installation of this test facility.

  • PDF

The Leisure Constraint and Leisure Life Satisfaction of the Institutionalized Elderly in Seoul - Focusing on the Free Institutionalized Elderly - (서울시 시설거주 노인의 여가프로그램제약정도와 여가생활만족도 - 무료양로시설을 중심으로 -)

  • Park Mee Sok
    • Journal of the Korean Home Economics Association
    • /
    • v.43 no.4 s.206
    • /
    • pp.203-223
    • /
    • 2005
  • This study investigated the leisure constraints and leisure life satisfaction of the institutional elderly. The respondents were 302 elderly people residing in 5 free institutionalized elderly homes in Seoul. The data were analyzed by frequency analysis, factor analysis, One-way ANOVA, Duncan's post hoc test and regression analysis using SPSS WIN 12.0 program. Exploratory factor analysis revealed that the 10 items in the proposed scale could be grouped into four factors of constraint on leisure:'physical constraint','psychological constraint','interpersonal constraint', and 'structural constraint 'There were differences in leisure constraints according to sex, age, education degree, interaction with facility colleagues, and interaction with facility staff. There were differences in leisure life satisfaction according to sex, age, having religion or not, interaction with facility colleagues, interaction with facility staff and leisure constraints. Regression analysis results indicated that the main effective factors of leisure life satisfaction were leisure constraints.

High-temperature ultrasonic thickness monitoring for pipe thinning in a flow-accelerated corrosion proof test facility

  • Cheong, Yong-Moo;Kim, Kyung-Mo;Kim, Dong-Jin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1463-1471
    • /
    • 2017
  • In order to monitor the pipe thinning caused by flow-accelerated corrosion (FAC) that occurs in coolant piping systems, a shear horizontal ultrasonic pitch-catch waveguide technique was developed for accurate pipe wall thickness monitoring. A clamping device for dry coupling contact between the end of the waveguide and pipe surface was designed and fabricated. A computer program for multi-channel on-line monitoring of the pipe thickness at high temperature was also developed. Both a four-channel buffer rod pulse-echo type and a shear horizontal ultrasonic waveguide type for high-temperature thickness monitoring system were successfully installed to the test section of the FAC proof test facility. The overall measurement error can be estimated as ${\pm}10{\mu}m$ during a cycle from room temperature to $200^{\circ}C$.

Methodology Study of Design Related to Accidental Explosion of Simple Explosive Storage Facility (화약류 간이저장소의 우발적 폭발을 고려한 안전설계 방법 연구)

  • Jung-Gyu, Kim;Seung-Won, Jung;Jun-Ha, Kim;Byung-Hee, Choi
    • Explosives and Blasting
    • /
    • v.40 no.4
    • /
    • pp.1-14
    • /
    • 2022
  • To review the appropriateness of current regulations on the simple explosive storage facility, the effects of internal explosion on the structural stability of the standard storage facility were analyzed by means of both FEM analyses and field experiments. As a result, it was found that the explosion-proof performance of the existing storage structure was not sufficient for 15 kg of emulsion-type explosive. Thus, an alternative method of splitting explosives was tested by conducting sympathetic detonation experiments. This method worked properly as expected, and the proper amount of splitted explosive was determined according to the test results. In addition, a storage structure with open ceiling was found to be very effective because explosion pressure was released so rapidly that the damage of the facility could be reduced significantly. Hence, such a structural pattern was proposed as a new design scheme for simple explosive storage facility.

A Study on Social Carrying Capacity in Outdoor Recreation Setting: An Exploratory Analysis on the Perceived Crowding Path Model in National Park (옥외휴양공간에서의 사회적 수용능력연구: 국립공원에서의 혼잡지각의 경로모형 분석)

  • Park, Chung In
    • KIEAE Journal
    • /
    • v.5 no.1
    • /
    • pp.35-42
    • /
    • 2005
  • The primary concerns of recreation plan are to provide visitors with quality of recreational experience and to protect of recreation resources. The quality of recreational experience is often defined in terms of social carrying capacity. The carrying capacity is revealed as perceived crowding. In this respects, measuring perceived crowding is useful tool of social carrying capacity determination. This study is to test the structural equation model that includes variables affecting perceived crowding. Through an on-site questionnaire survey, 467 visitors on Naejangsan national park were collected. The results of the study are follows. The encounter level on facility area is higher evaluated as crowding factor than other area in the park. It can be concluded that visitor perceived crowding when facility area situates high density use level rather than other areas expose high density use level. In the path analysis, the input variables(attitude, experience, encounter level) on the structural equation model affect significantly on perceived crowding. Especially, the attitude on the park management polocy is the most affecting factor on perceived crowding.

Experimental investigation of the behaviour of a steel sub-frame under a natural fire

  • Santiago, Aldina;Simoes da Silva, Luis;Vaz, Gilberto;Vila Real, Paulo;Lopes, Antonio Gameiro
    • Steel and Composite Structures
    • /
    • v.8 no.3
    • /
    • pp.243-264
    • /
    • 2008
  • This paper details a testing facility ("NATURAL FIRE FACILITY") that allows closely-controlled experimental testing on full-scale sub-frames while reproducing the spatially transient temperature conditions measured in real fires. Using this test facility, an experimental investigation of six steel sub-frames under a natural fire was carried out at the Department of Civil Engineering of the University of Coimbra. The main objective of these tests was to provide insight into the influence of these connection types on the behaviour of steel sub-structures under fire. The experimental layout is defined by two thermally insulated HEA300 columns and an unprotected IPE300 beam with 5.7 m span, supporting a composite concrete slab. Beam-to-column connections are representative of the most common joint type used on buildings: welded joints and extended, flush and partial depth plate. Finally, the available results are presented and discussed: evolution of the steel temperature; development of displacements and local deformations and failure modes on the joints zone.

The Relationship between scuba diving participant's selective attribute, emotional response, and empirical value

  • Lee, Yoo-Chan;Jung, Sang-Ok
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.84-91
    • /
    • 2021
  • The purpose of this study is to investigate the structural relationship between resort selection attributes, emotional responses, and empirical values of scuba diving participants. The general population who enjoys scuba diving in Korea was selected as the population. Using the convenience sampling method, 553 of the 600 questionnaire samples were extracted as the final valid sample. For data processing, frequency analysis, exploratory factor analysis, and Cronbach's α test were performed using SPSS 23, and confirmatory factor analysis and structural equation model analysis were performed with AMOS 18. The results are as follows: First, among the sub-factors of selection attributes, equipment, facility environment, and diving point showed a positive effect on emotional response, but staff service did not have any significant effect. Second, the emotional response positively affected by the selection attribute showed a positive effect on all factors of service excellence, consumer utility, fun value, and aesthetic value of empirical value. Therefore, scuba diving resort managers must recognize the importance of equipment, facility environment, and diving point among these selection attributes of customers. And to satisfy the customer needs the resort must accurately identify the needs for diving equipment, facility environment and diving point. Various methods for this should be explored through the needs of the identified customers, and efforts should be made to provide safe equipment, comfortable facilities, and various diving points.

Design Enhancement of CANDU S/F Storage Basket (CANDU 사용후핵연료 저장바스켓 설계 개선안 도출)

  • Choi, Woo-Seok;Seo, Ki-Seog;Park, Wan-Gyu
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.2
    • /
    • pp.105-115
    • /
    • 2012
  • Necessity of demonstration test to evaluate the structural integrity of a basket for accident conditions arose during license approval procedure for the WSPP's dry storage facility named MACSTOR/KN-400. A drop test facility for demonstration was constructed in KAERI site and demonstration tests for basket drop were conducted. As the upper welding region of a loaded basket was collided with a dropped basket during the drop test, the welding in this region was fractured and leakage happened after the drop test. The enhancement of basket design was needed since the existing basket design was not able to satisfy the performance requirement. The directions for design modification were determined and six enhanced designs were derived based on these directions. Structural analyses and specimen tests for each enhanced design were conducted. By evaluating structural analysis results and test results, one among six enhanced designs was decided as a final design for revision. The final design was the one to reduce the height of central post of a basket and to decrease the impact velocity with a dropped basket. Test basket models were fabricated with accordance with the final enhanced design. Additional demonstration test was performed for this test model and all the performance requirements were satisfied.