• 제목/요약/키워드: Structural safety test

검색결과 936건 처리시간 0.028초

CONTAMINANT LEACHABILITY FROM UTILIZED WASTES IN GEOSYSTEMS

  • Inyang Hilary I.
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2005년도 INTERNATIONAL SYMPOSIUM ON SOIL & GROUNDWATER ENVIRONMENT
    • /
    • pp.5-21
    • /
    • 2005
  • Urbanization rates of population range from about 1% in the developed countries to about 4% in developing countries. For a global population that may reach 10 billion within the next 40 years, pressure has arisen for an increase in the large-scale use of wastes and byproducts in construction. Ironically, most of the wastes that need to be recycled are generated in large cities where the need for constructed facilities to serve large population is high. Waste and recycled materials (WRM) that are used in construction are required to satisfy material strength, durability and contaminant teachability requirements. These materials exhibit a wide variety of characteristics owing to the diversity of industrial processes through which they are produced. Several laboratory-based investigations have been conducted to assess the pollution potential and load bearing capacity of materials such as petroleum-contaminated soils, coal combustion ash, flue-gas desulphurization gypsum and foundry sand. For full-scale systems, although environmental pollution potential and structural integrity of constructed facilities that incorporate WRM are interrelated, comprehensive schemes have not been developed for integrated assessment of the relevant field-scale performance factors. In this presentation, a framework for such an assessment is proposed and presented in the form of a flowchart. The proposed scheme enables economic, environmental, worker safety and engineering factors to be addressed in a number of sequential steps. Quantitative methods and test protocols that have been developed can be incorporated into the proposed scheme for assessing the feasibility of using WRM as partial or full substitutes for earthen highway materials in the field.

  • PDF

석조문화재 받침용 쐐기 재질의 물성 실험 연구 (The study on the property of material for the shim of stone cultural properties)

  • 엄두성;홍정기;김사덕;강대일;이명희
    • 보존과학연구
    • /
    • 통권21호
    • /
    • pp.101-118
    • /
    • 2000
  • Stone cultural properties(pagoda, Buddhist statue etc.) is moved in original place for many reasons and restored after taking to pieces for structural safety. With the movement and restoration after taking to pieces, the cast iron is used for the sake of a fixation and horizontality. The stone cultural properties are spoiled the beauty and accelerated the weathering because of the corrosion product of cast iron. So we need to substitute for the improved property in all aspects. We are executed the corrosion test and inquired the property of material on the usable material for the shim of stone cultural properties. That is the Cast iron, Stainless steel, Titanium and Fiber Reinforced Plastics. In the result of the physical property and strength, the Stainless steel and Titanium was superior to the Cast iron. And the Stainless steel and Titanium was slower than the Cast iron in the corrosion velocity for the acid, salt and rain. If the shim is substitute the Stainless steel or Titanium for the Cast iron, the stone cultural properties are able to reduce the pollution of stone cultural properties by corrosion product and should not happen in the matter of stone pagoda.

  • PDF

Application of fractals to study the corroded reinforced concrete beam

  • Fan, Y.F.;Zhou, J.;Hu, Z.Q.
    • Structural Engineering and Mechanics
    • /
    • 제20권3호
    • /
    • pp.265-277
    • /
    • 2005
  • This paper is focused on fractal analysis of the surface cracking, a new tool for safety evaluation of corroded reinforced concrete (RC) beams. Comprehensive experimental investigations, including flexural tests, coupon tests on strength evaluation of corroded concrete and rusty rebar, and pullout tests to determine bond strength between concrete and rebar were carried out on nine Corroded Reinforced Concrete Beams (CRCB) exposed to an aggressive environment for more than 10 years. In combination with test results from a previous study on CRCBs fabricated in the laboratory from accelerated methods, it is found that, for both types of beams, the surface cracking distributions are fractal in character at loading and failure stages. Fractal dimension is calculated for all specimens at different corrosion states based on fractal analysis method. Relationships between the fractal dimension and mechanical properties of corroded concrete, rebar corrosion ratio, and ductility of CRCBs are discussed in detail. It is concluded that the fractal dimension can act as a damage index and can be efficiently used to describe the corrosion state of CRCBs.

연안 소형선박 수리용 해상 상가시스템 개발 (A Study on Development of a Marine Docking System for Repair of a Small Coast-Boat)

  • 박충환;장동원;양향권;진종룡
    • 한국해양공학회지
    • /
    • 제22권4호
    • /
    • pp.78-83
    • /
    • 2008
  • In recent years, small boats used for marine leisure have been steadily increasing because of the increase in national income and the desire for marine leisure. But the repair of such small boats in dry dock has pointed out many faults in small FRP-shipbuilding in terms if workspace and manpower. Lifting a boat from the water to land is done with a crane or by hand using a sling around the bottom of the boat. But dry dock work is limited by the scale of the boat, which corresponds to the crane capacity, with carelessness making it possible to capsize a boat and endanger life. The purpose of this study was the development of a marine docking system that would improve economical efficiency and safety, for which we carried out concept design, model tests, structural analysis, etc.

Effects of Isolation Period Difference and Beam-Column Stiffness Ratio on the Dynamic Response of Reinforced Concrete Buildings

  • Chun, Young-Soo;Hur, Moo-Won
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권4호
    • /
    • pp.439-451
    • /
    • 2015
  • This study analyzed the isolation effect for a 15-story reinforced concrete (RC) building with regard to changes in the beam-column stiffness ratio and the difference in the vibration period between the superstructure and an isolation layer in order to provide basic data that are needed to devise a framework for the design of isolated RC buildings. First, this analytical study proposes to design RC building frames by securing an isolation period that is at least 2.5 times longer than the natural vibration period of a superstructure and configuring a target isolation period that is 3.0 s or longer. To verify the proposed plan, shaking table tests were conducted on a scaled-down model of 15-story RC building installed with laminated rubber bearings. The experimental results indicate that the tested isolated structure, which complied with the proposed conditions, exhibited an almost constant response distribution, verifying that the behavior of the structure improved in terms of usability. The RC building's response to inter-story drift (which causes structural damage) was reduced by about one-third that of a non-isolated structure, thereby confirming that the safety of such a superstructure can be achieved through the building's improved seismic performance.

부착형 복합소재를 이용한 교육시설의 내진보강 (Seismic Retrofit in Educational Facilities Using Attaching Composite Material)

  • 박춘욱;송건수;박익현;김동휘
    • 한국공간구조학회논문집
    • /
    • 제13권3호
    • /
    • pp.73-81
    • /
    • 2013
  • In paper after the strong earthquake of recently the Korea neighborhood, the Korean government survey show that the 86% of school buildings in Korea are in potential damage risk and only 14% of them are designed as earthquake-resistance buildings. Earthquake Reinforcing projects of school have been a leading by the ministry of education, however their reinforcing methods done by not proved a engineering by experiment which results in uneconomical and uneffective rehabilitation for the future earthquake. An experimental and analytical study have been conducted for the shear reinforcing method of column by axis and horizontal axis load using attaching composite beam. Based on the previous research, in this study, Design examples are given to show the performance evaluation for the column reinforcing of old school buildings using nonlinear analysis is going to be conducted and strengthening method is going to be on the market after their performance is proved by the test.

Effect of stiffener arrangement on hysteretic behavior of link-to-column connections

  • Zarsav, Saman;Zahrai, Seyed Mehdi;Oskouei, Asghar Vatani
    • Structural Engineering and Mechanics
    • /
    • 제57권6호
    • /
    • pp.1051-1064
    • /
    • 2016
  • Link-to-column connections in Eccentrically Braced Frames (EBFs) have critical role in their safety and seismic performance. Accordingly, in this study, contribution of supplemental stiffeners on hysteretic behavior of the link-to-column connection is investigated. Considered stiffeners are placed on both sides and parallel to the link web between the column face and the first stiffener of the link. Hysteretic behaviors of the link beams with supplemental stiffeners are numerically investigated using a pre-validated numerical model in ANSYS. It turned out that supplemental stiffeners can change energy dissipation mechanism of intermediate links from shear-flexure to shear. Both rectangular and trapezoidal supplemental stiffeners are studied. Moreover, optimal placement of the supplemental stiffeners is also investigated. Obtained results indicate a discrepancy of less than 9% in maximum link shear of the numerical and experimental specimens. This indicates that the numerical results are in good agreement with those obtained from the test. Trapezoidal supplemental stiffeners improve rotational capacity of the link. Moreover, use of two supplemental stiffeners at both ends of the link can more effectively improve hysteretic behavior of intermediate links. Supplemental stiffeners would also alleviate the imposed demands on the connections. This latter feature is more pronounced in the case of two supplemental stiffeners at both ends of the link.

Experimental study on the vibration mitigation of offshore tension leg platform system with UWTLCD

  • Lee, Hsien Hua;Juang, H.H.
    • Smart Structures and Systems
    • /
    • 제9권1호
    • /
    • pp.71-104
    • /
    • 2012
  • In this research, a typical tension-leg type of floating platform incorporated with an innovative concept of underwater tuned liquid column damper system (UWTLCD) is studied. The purpose of this study is to improve the structural safety by means of mitigating the wave induced vibrations and stresses on the offshore floating Tension Leg Platform (TLP) system. Based on some encouraging results from a previous study, where a Tuned Liquid Column Damper (TLCD) system was employed in a floating platform system to reduce the vibration of the main structure, in this study, the traditional TLCD system was modified and tested. Firstly, the orifice-tube was replaced with a smaller horizontal tube and secondly, the TLCD system was combined into the pontoon system under the platform. The modification creates a multipurpose pontoon system associated with vibration mitigation function. On the other hand, the UWTLCD that is installed underwater instead would not occupy any additional space on the platform and yet provide buoyancy to the system. Experimental tests were performed for the mitigation effect and parameters besides the wave conditions, such as pontoon draught and liquid-length in the TLCD were taken into account in the test. It is found that the accurately tuned UWTLCD system could effectively reduce the dynamic response of the offshore platform system in terms of both the vibration amplitude and tensile forces measured in the mooring tethers.

용접열사이클 재현에 의한 SS400강 및 STS304강의 특성 평가 - 제1보 : 기계적 특성 및 조직 (Evaluation of Characteristic for SS400 and STS304 steel by Weld Thermal Cycle Simulation - 1st Report : on the Mechanical Properties and Microstructure)

  • 안석환;정정환;남기우
    • 한국해양공학회지
    • /
    • 제19권6호통권67호
    • /
    • pp.64-71
    • /
    • 2005
  • The welding methods have been applied to the most structural products used in the automobile, ship construction, and construction. The structure steel must have sufficient strength of structure; However, the mechanical properties of the welded part changes when it is welded. Therefore, the stability or life of the structure may be affected by the changed mechanical properties. The mechanical properties of the welded part must be examined in order to ensure the safety of structure. In this research, the SS400 steel and the STS304 steel were used to estimate the mechanical properties of the HAZ by weld thermal cycle simulation. In this study, the materials were used to examine the weld thermal cycle simulation characteristic, under two conditions: the drawing with diameter of $\Phi$10 and the residual stress removal treatment. To examine the mechanical properties by the weld thermal cycle simulation, the tensile test was carried out in room temperature. The crosshead speed was lmm/min.

Seismic capacity of brick masonry walls externally bonded GFRP under in-plane loading

  • Wang, Quanfeng;Chai, Zhenling;Wang, Lingyun
    • Structural Engineering and Mechanics
    • /
    • 제51권3호
    • /
    • pp.413-431
    • /
    • 2014
  • By carrying out the experiment of eight pieces of brick masonry walls with pilaster strengthened by Glass fiber reinforced polymer (GFRP) and one piece of normal masonry wall with pilaster under low reversed cyclic loading, the failure characteristic of every wall is explained; Seismic performances such as hysteresis, stiffness and its degeneration, deformation, energy consumption and influence of some measures including strengthening means, reinforcement area proportion between GFRP and wall surface, "through-wall" anchor on reinforcement effects are studied. The test results showed that strengthening modes have little influence on stiffness, stiffness degeneration and deformation of the wall, but it is another thing for energy consumption of the wall; The ultimate load, deformation and energy consumption of the walls reinforced by glass fiber sheets was increased remarkably, rigidity and its degeneration was slower; Seismic performance of the wall which considers strengthening means, reinforcement area proportion between GFRP and wall surface, "through-wall" anchor at the same time is better than under the other conditions.