• 제목/요약/키워드: Structural safety test

검색결과 936건 처리시간 0.035초

Reliability-based assessment of high-speed railway subgrade defect

  • Feng, Qingsong;Sun, Kui;Chen, Hua-peng
    • Structural Engineering and Mechanics
    • /
    • 제77권2호
    • /
    • pp.231-243
    • /
    • 2021
  • In this paper, a dynamic response mapping model of the wheel-rail system is established by using the support vector regression (SVR) method, and the hierarchical safety thresholds of the subgrade void are proposed based on the reliability theory. Firstly, the vehicle-track coupling dynamic model considering the subgrade void is constructed. Secondly, the subgrade void area, the subgrade compaction index K30 and the fastener stiffness are selected as random variables, and the mapping model between these three random parameters and the dynamic response of the wheel-rail system is built by using the orthogonal test and the SVR. The sensitivity analysis is carried out by the range analysis method. Finally, the hierarchical safety thresholds for the subgrade void are proposed. The results show that the subgrade void has the most significant influence on the carbody vertical acceleration, the rail vertical displacement, the vertical displacement and the slab tensile stress. From the range analysis, the subgrade void area has the largest effect on the dynamic response of the wheel-rail system, followed by the fastener stiffness and the subgrade compaction index K30. The recommended safety thresholds for the subgrade void of level I, II and III are 4.01㎡, 6.81㎡ and 9.79㎡, respectively.

RC교각 코핑부 배근방법에 따른 안전성 평가 (Safety Assessment of RC Pier Coping According to Modification of Rebar Arrangement)

  • 박봉식;박성현;신왕수;조재열
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1519-1525
    • /
    • 2011
  • Construction of the coping of reinforced concrete piers is very complicated due to heavy density of rebars and usually exposed to negligent accident. To correct these problems, coping is pre-assembled at the ground in pier coping pre-assembly method and recently a new method of rebar assembling has proposed in this study. For safety assessment of proposed method, small scale model test of railway bridge(PSC U-GIRDER T-shaped pier) was carried out and it was verified that crack pattern, failure mechanism and load resistance capacity are similar between existing method and proposed method. And using analytical approach, linear and non-linear finite element analysis was performed. As a result, it was checked that proposed method has an acceptable structural safety.

  • PDF

PSC 바닥판의 피로 안전성 평가 (Estimation of Fatigue safety for PSC Bridge Decks)

  • 김영진;이정우;주봉철;김병석;박성용;이필구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.525-530
    • /
    • 2002
  • This study is peformed to propose the slab deck for the composite bridge with two girders. Considering the characteristics of the long span and the construction conditions in korea, a cast-in-place PSC deck was proposed for that bridge. To examine structural behaviors and safety of the proposed PSC deck, two real scale partitions of deck(12m$\times$3.2m) were tested under the fatigue loading. In the test, the failure mode and behaviors of each specimen, and the ultimate load carrying capacity of the two-girder-bridge deck were identified. Generally, the failure of concrete bridge deck is caused by the local punching shear stress resulting from the moving wheel load. Even though its ultimate flexural capacity is sufficiently larger than the demand, it could be failed by the punching shear fatigue. Therefore, the fatigue safety of the proposed PSC deck should be checked.

  • PDF

초기결함을 갖는 강교량의 피로시험 및 수명 평가 (Fatigue Test and Service Life Assessment of Steel Truss Bridges with Initial Imperfections)

  • 방명석
    • 한국안전학회지
    • /
    • 제15권4호
    • /
    • pp.119-122
    • /
    • 2000
  • The truss bridge is composed of numerous steel beams. In long span bridges the size of beams is getting larger, so the number of plate girders is increasing instead of rolled beams. This plate girder has long welding lines at the intersection of steel plates. The improper welding at the intersection line causes the steel bridge to be structurally unsafe. In this paper the loss of member section from improper welding was measured and the experimental testing was performed to get the S-N curve from testing models with sectional losses. The improper welding resulted in the lowering of structural safety and the shortening of life cycle.

  • PDF

네트워크 통신장비의 진동 해석 (Vibration Analysis of Network Communication Equipment)

  • 이재환;김영중;김진섭
    • 한국전산구조공학회논문집
    • /
    • 제20권4호
    • /
    • pp.463-468
    • /
    • 2007
  • 최근 일본에서 발생한 지진으로 이동통신용 전자장비들이 많이 파손되었으나. 국내에서 제작되어 일본에 설치된 모제품은 강진에서도 대부분 구조적 손상이 없었다. 본 논문에서는 이동통신 네트워크 장비의 정/동적 특성을 평가하기 위하여 제품의 유한요소 모델을 생성하여 정적 및 동적 구조해석을 수행하였다. 또한 Zone 3 GR-63-CORE 동적 실험을 수행하여 제품의 안정성을 검증하였고, 유한요소 구조해석 결과와 비교하여 실험과 해석 결과가 유사함이 입증되었다. 구조해석 결과인 동적 응답특성은 실험보다 다소 크게 나왔으며, 부재의 특성파악을 위해 구조물의 치수를 설계변수로 하여 진동특성에 대한 민감도 해석으로 고유진동수에 민감한 부재를 판별하였고, 치수변경으로 경량화 설계치를 산출하였다. 경량화된 디자인의 동적 응답변위가 원래 디자인보다 작게 나와 최적화 결과가 유용할 것으로 보인다.

유공위치 변경에 따른 RC기둥의 내력변화에 관한 실험적 연구 (Stress Change Varying with Hole Place of RC Column)

  • 손기상
    • 한국안전학회지
    • /
    • 제21권2호
    • /
    • pp.70-79
    • /
    • 2006
  • many plumbing system are needed in the ceiling of the building as it becomes advanced more and more. This leads to make effective space between ceiling level and slab less. Also, piping system is not suitably arranged and operated if it is bent around the columns which they are a lot. But this system can be more effective if it passes through the columns directly. Most people think that those columns should not be damaged with such as holes. But actually this is existed in a hotel building in switzerland. This study is to fing out how much capacity the columns become damaged and low using model size of $20cm{\times}30cm$ rectangular section, and 160cm long, in the structural test. it's compressive strength is focused on $240kg/cm^{2}$ design strength, commonly used in korea. Compressive test for them was done at Hanyang University using UTM one thousand tone(1000t) capacity. Variable numbers for the study are one hole of dia 3cm with distance 20cm or 40cm, two holes of dia 3cm with 20cm and 40cm distance, one hole of dia 5cm with distance 20cm and 40cm, two holes of dia 5cm with 20cm and 40cm distance, me eccentric hole with 20cm and 40cm distance, Normal(without hole). two test specimens of each variable are made for the test. ED5H20 capacity was 16.7% decreased, compared to normal one. While ED5H40 distant 40cm from the end of column top showed 19.5% capacity decrease, compared to normal one. Strain of ED5H20 diameter 5cm, in distance of 20cm form the top of the column was less 5% than the one of diameter 3cm. Finally, conclusions are that in case of hole diameter 3cm, located at 20cm from the end of the column top, capacity was decreased down to 3, percent only compared to the same diameter hole with 20cm distant from the end of it.

프리스트레스트 콘크리트 부재용 재긴장 정착구 하중전달시험 (Load Transfer Test for Re-tensioning Post-Tension Kit for Prestressed Concrete)

  • 허재훈;노병철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권5호
    • /
    • pp.8-14
    • /
    • 2021
  • 포스트텐션 프리스트레스트 콘크리트 부재는 즉시 손실 이외에도 크리프, 건조수축 및 릴렉세이션과 같은 시간적 손실이 발생한다. 아울러 상부 슬래브 또는 포장 등의 교체 등에 의한 고정하중 변동으로 인하여 부재 상하부의 응력이 변화하게 된다. 이러한 응력의 변화는 부재의 안전성에 영향을 줄 경우가 있으며, 이 경우 프리스트레스 힘의 조절이 필요하다. 따라서 이 연구에서는 나사를 적용한 새로운 유형의 재긴장 포스트텐션 정착구를 제안하고, EAD160004 및 KCI-PS101에 규정된 하중전달시험을 통하여 하중에 대한 안전성과 변형률에 대한 안정성을 만족함을 구명하였다.

손상 허용 설계를 적용한 복합재 날개의 정하중 시험 (Static Test of a Composite Wing with Damage Tolerance Design)

  • 박민영
    • 한국항공우주학회지
    • /
    • 제46권6호
    • /
    • pp.471-478
    • /
    • 2018
  • 본 연구에서는 복합재 날개 구조물에 손상허용설계를 적용하고 이를 입증하기 위한 정하중 시험을 수행하였다. 복합재 날개 구조의 정적강도를 입증하기 위하여 5 조건의 설계 제한하중 시험과 3 조건의 설계 극한하중 시험을 수행하였다. 그 다음으로 손상허용 설계를 입증하기 위하여 관련 규정에 따라서 복합재 주익 주요 취약부위에 BVID 10개, Open hole 11개를 생성 후, 설계 극한하중 시험과 파단시험을 실시하였다. 날개 주요 부위의 변위 및 변형률 시험 결과는 구조해석 결과와 비교적 잘 일치하였으며, 파단시험의 최초 파단부위도 최소안전여유를 갖는 부위에서 발생하여 구조해석 모델 및 강도평가 결과가 실제 구조의 정적 거동과 유사함을 확인하였다.

소형 승용차량의 측면충돌 시 탑승자 보호성능 평가 (Evaluation of Occupant Protection of Passenger Vehicles at IIHS Side Impact)

  • 김관희;임종훈;임장호;박인송;조종두
    • 한국자동차공학회논문집
    • /
    • 제22권1호
    • /
    • pp.46-51
    • /
    • 2014
  • 2,097 deaths out of 5,229 by traffic accident occurred by vehicle to vehicle crash and 855 deaths out of 2,097 occurred at side crash in 2011. Korean government adopted New Car Assessment Program to reduce the wounded and deaths at traffic accident in 1999 and side impact test has been added in 2003. 43 out of 53 vehicles tested in NCAP side impact rated 4 and 5 stars means the highest occupant protection. In this study three small class vehicles have been tested according to Insurance Institute for Highway Safety's side crashworthiness test protocol. IIHS test protocol uses 1,500kg moving barrier rather than NCAP's 950kg and the occupant protection rated Good, Acceptable, Marginal and Poor based on injury measure, structural integrity and head protection.

Continuous deformation measurement for track based on distributed optical fiber sensor

  • He, Jianping;Li, Peigang;Zhang, Shihai
    • Structural Monitoring and Maintenance
    • /
    • 제7권1호
    • /
    • pp.1-12
    • /
    • 2020
  • Railway tracks are the direct supporting structures of the trains, which are vulnerable to produce large deformation under the temperature stress or subgrade settlement. The health status of track is critical, and the track should be routinely monitored to improve safety, lower the risk of excess deformation and provide reliable maintenance strategy. In this paper, the distributed optical fiber sensor was proposed to monitor the continuous deformation of the track. In order to validate the feasibility of the monitoring method, two deformation monitoring tests on one steel rail model in laboratory and on one real railway tack in outdoor were conducted respectively. In the model test, the working conditions of simply supported beam and continuous beam in the rail model under several concentrated loads were set to simulate different stress conditions of the real rail, respectively. In order to evaluate the monitoring accuracy, one distributed optical fiber sensor and one fiber Bragg grating (FBG) sensor were installed on the lower surface of the rail model, the strain measured by FBG sensor and the strain calculated from FEA were taken as measurement references. The model test results show that the strain measured by distributed optical fiber sensor has a good agreement with those measured by FBG sensor and FEA. In the outdoor test, the real track suffered from displacement and temperature loads. The distributed optical fiber sensor installed on the rail can monitor the corresponding strain and temperature with a good accuracy.