• Title/Summary/Keyword: Structural safety test

Search Result 941, Processing Time 0.026 seconds

A Study on Fatigue Characteristics and Analysis for A 182 F6a Class 4 Materials (A182 F6A Class4 재료의 피로특성과 피로해석에 대한 연구)

  • Jin-Kyung Lee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.585-589
    • /
    • 2023
  • Unlike general carbon steel, stainless steel's mechanical properties change depending on the content of chromium and nickel. In this study, since stainless steel for high-temperature pressure container parts is used as shafts, the fatigue strength and fatigue limit of the materials were evaluated using a rotational bending fatigue test. Meanwhile, fatigue analysis was conducted under the same conditions as the specimen for structural analysis and fatigue analysis of stainless steel for high-temperature pressure container parts. Using the fatigue analysis results, we tried to derive the life of the material and the safety factor for each part. As a result of performing a fatigue test by processing a specimen for the fatigue test of A182 F6A stainless steel, the fatigue limit was 548 MPa. The ratio between the tensile strength and fatigue limit of the material was 0.545, representing 54.5% of the tensile strength.

A Study on Resonance and Interference of a Cooling Fan Assembly by Using FEM (유한요소법을 이용한 냉각홴의 진동 및 간섭에 관한 연구)

  • Seo Jong-Hwi;Song Ha-Jong;Park Tae-Won;Kim Joo-Yong;Jung Il-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.9 s.90
    • /
    • pp.903-909
    • /
    • 2004
  • A CFA(cooling fan assembly) is composed of a fan, motor and shroud, which is at the back of the automotive radiator. By forcing the wind to pass, the CFA controls the cooling performance of the radiator. The noise and vibration of the CFA may be primarily due to the resonance between the CFA and engine. The Interference among the fan, shroud and radiator by deformation is considered when the CFA is designed. In this paper, in order to analyze the structural vibration of the CFA for automobiles, a finite element model of the CFA is established by using a commercial FEM code. After the finite element modeling, the natural frequencies and the mode shapes are obtained from the FE analysis. The natural frequencies are obtained from the vibration test as well. Then, the results of the vibration test are compared with those of the FE analysis. The natural frequencies obtained by experiment have a great similarity to the results from FE model. We have confirmed the validity of the FE model and verify the structural safety for the resonance. The stress and displacements are obtained from FE analysis. We have confirmed the safety for the interference and failure.

Characteristics of Structural Behavior and Safety Estimation of Water Supply GFRP Pipe (상수도용 유리섬유복합관의 구조적 거동특성 및 안전성 평가)

  • Lee, Bo-Be;Lee, Seung-Sik;Joo, Hyung-Jong;Yoon, Soon-Jng
    • Composites Research
    • /
    • v.22 no.3
    • /
    • pp.1-8
    • /
    • 2009
  • In this paper, we present the results of experimental and analytical investigations on the structural behavior of GFRP pipes used in the water supply pipeline system. Cross-section of the pipe is consisted with two GFRP tubes and polymer mortar between the tubes. Due to the advantages such as light-weight, corrosion resistance, smooth surface, flexibility, etc., use of GFRP pipe in the water supply pipeline system is ever increasing trend. Therefore, more optimized structural design methodology should be developed. In the investigation, we conducted theoretical and analytical studies on the load versus radial deformation characteristics of GFRP pipes. In addition, ring stiffness test is also performed. Test results are compared with theoretical and analytical results and it was found that the results are agreed well within 5% of radial deformation. Finally, it was also found that the GFRP pipes used in the water supply pipeline system are strong enough to satisfy the industrial requirements.

Experimental study on wave forces to offshore support structures

  • Jeong, Youn-Ju;Park, Min-Su;You, Young-Jun
    • Structural Engineering and Mechanics
    • /
    • v.60 no.2
    • /
    • pp.193-209
    • /
    • 2016
  • In this study, wave force tests were carried out for the four types of offshore support structures with scale factor 1:25 and wave forces to the support structure shapes were investigated. As the results of this study, it was found that, as the wave period increased at the normal wave condition, wave force decreased for the most cases. Extreme wave force was affected by the impact wave force. Impact wave force of this study significantly effect on Monopile and slightly on GBS and Hybrid type. Accordingly, Hybrid type indicated even lower wave force at the extreme and irregular wave conditions than the Monopile although Hybrid type indicated higher wave force at the normal wave condition of the regular wave because of the larger wave area of wave body. In respects of the structural design, since critical loading is extreme wave force, it should be contributed to improve structural safety of offshore support structure. However, since the impact wave force has nonlinearity and complication dependent on the support structure shape, wave height, wave period, and etc., more research is needed to access the impact wave force for other support structure shapes and wave conditions.

Optimal Sensor Allocation of Cable-Stayed Bridge for Health Monitoring (사장교의 상시감시를 위한 최적 센서 구성)

  • Heo, Gwang-Hee;Choi, Mhan-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.2
    • /
    • pp.145-155
    • /
    • 2002
  • It is essential for health monitoring of a cable-stayed bridge to provide more accurate and enough information from the sensors. In experimental modal testing, the chosen measurement locations and the number of measurements have a major influence on the quality of the results. The choice is often difficult for complex structures like a cable-stayed bridge. It is extremely important a cable-stayed bridge to minimize the number of sensing operations required to monitor the structural system. In order to obtain the desired accuracy for the structural test, several issues must take into consideration. Two important issues are the number and location of response sensors. There are usually several alternative locations where different sensors can be located. On the other hand, the number of sensors might be limited due to economic constraints. Therefore, techniques such as methodologies, algorithms etc., which address the issue of limited instrumentation and its effects on resolution and accuracy in health monitoring systems are paramount to a damage diagnosis approach. This paper discusses an optimum sensor placement criterion suitable to the identification of structural damage for continuous health monitoring. A Kinetic Energy optimization technique and an Effective Independence Method are analyzed and numerical and theoretical issues are addressed for a cable-stayed bridge. Its application to a cable-stayed bridge is discussed to optimize the sensor placement for identification and control purposes.

Structural analysis of high-rise reinforced concrete building structures during construction

  • Song, Xiaobin;Gu, Xianglin;Zhang, Weiping;Zhao, Tingshen;Jin, Xianyu
    • Structural Engineering and Mechanics
    • /
    • v.36 no.4
    • /
    • pp.513-527
    • /
    • 2010
  • This paper presents a three-dimensional finite element method based structural analysis model for structural analysis of reinforced concrete high-rise buildings during construction. The model considered the time-dependency of the structural configuration and material properties as well as the effect of the construction rate and shoring stiffness. Uniaxial compression tests of young concrete within 28 days of age were conducted to establish the time-dependent compressive stress-strain relationship of concrete, which was then used as input parameters to the structural analysis model. In-situ tests of a RC high-rise building were conducted, the results of which were used for model verification. Good agreement between the test results and model predictions was achieved. At the end, a parametric study was conducted using the verified model. The results indicated that the floor position and construction rate had significant effect on the shore load, whereas the influence of the shore removal timing and shore stiffness have much smaller. It was also found that the floors are more prone to cracking during construction than is ultimate bending failure.

Multiaxial fatigue behaviors of open-rib to crossbeam joints in orthotropic bridge structures

  • Yang, Haibo;Qian, Hongliang;Wang, Ping;Dong, Pingsha;Berto, Fillipo
    • Steel and Composite Structures
    • /
    • v.42 no.6
    • /
    • pp.843-853
    • /
    • 2022
  • The fatigue behavior of welded open rib-to crossbeam joints (ORCJ) in orthotropic bridge structures is investigated using a traction structural stress method. The fatigue behaviors of welded open rib-to crossbeam joints have been a subject of study for decades for ensuring operational safety and future design improvement. A mesh-insensitive combination of traction structural stresses in ORCJ was obtained considering the effect of in-plane shear stress and validated by fatigue test results. The proposed method is advantageous for predicting fatigue cracks that initiate from the crossbeam cutout and propagate along the crossbeam. The investigations carried out with the proposed approach reveal that the normal structural stress decreases with the propagation of fatigue cracks, while the ratio of shear stress to normal stress increases. The effect of shear structural stress is significant for the analysis of fatigue behavior of ORCJ in multiaxial stress states.

Measurement of Real Deformation Behavior in C-type Lng Mock-up Tank using Strain Gage (스트레인 게이지를 이용한 C-type LNG Mock-up 탱크 내조 실 변형 거동 측정)

  • Jung, Won-Do;Kim, Tae-Wook;Kim, Jeong-Hyeon;Lee, Do-Young;Chun, Min-Sung;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.117-124
    • /
    • 2016
  • A C-type LNG mock-up tank was constructed to evaluate the durability of the tank and its structural safety. An experimental strain analysis system equipped with strain gages was designed to investigate the structural behavior of the inner tank at a high hydraulic pressure. In addition, the insulation used in the space between the inner tank and outer tank had a compressive strength and the inner tank thickness of the cylindrical shell and hemisphere was 4.0 mm, which was designed to be thinner than the existing rules. The strains on the inner tank were measured with increasing pressure, and these measurements were compared and analyzed at the strain gage attachment points.

A Study and Design on Tank Container for Fuel Tank of LNG Fueled Ship (LNG 연료 추진선의 연료 탱크로서 탱크컨테이너의 적용성 연구 및 구조설계)

  • Kim, Tae-Woo;Suh, Yong-Suk;Jang, Ki-Bok;Chun, Min-Sung;Lee, Kang-Dae;Cha, Kyong-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.6
    • /
    • pp.504-511
    • /
    • 2012
  • The objective of this study is to investigate tank container to be used as fuel tank for LNG fueled ship. Feasibility of tank container to the fuel tank of LNG fueled ship is addressed and the advantage of tank container as fuel tank of ship is investigated. Conceptual configuration of the tank container is designed as well as structural analyses based on finite element method are carried out to meet the design regulation suggested by shipping register. Static loading is considered by structural analysis and impact test is performed. It is necessary to require SRS(shock response spectrum) in order to investigate structural safety which can meet.

Seismic assessment and finite element modelling of glazed curtain walls

  • Caterino, Nicola;Zoppo, Marta Del;Maddaloni, Giuseppe;Bonati, Antonio;Cavanna, Giovanni;Occhiuzzi, Antonio
    • Structural Engineering and Mechanics
    • /
    • v.61 no.1
    • /
    • pp.77-90
    • /
    • 2017
  • Glazed curtain walls are façade systems frequently chosen in modern architecture for mid and high-rise buildings. From recent earthquakes surveys it is observed the large occurrence of non-structural components failure, such as storefronts and curtain walls, which causes sensitive economic losses and represents an hazard for occupants and pedestrians safety. In the present study, the behavior of curtain wall stick systems under seismic actions has been investigated through experimental in-plane racking tests conducted at the laboratory of the Construction Technologies Institute (ITC) of the Italian National Research Council (CNR) on two full-scale aluminium/glass curtain wall test units. A finite element model has been calibrated according to experimental results in order to simulate the behavior of such components under seismic excitation. The numerical model investigates the influence of the interaction between glass panels and aluminium frame, the gasket friction and the stiffness degradation of aluminium-to-glass connections due to the high deformation level on the curtain walls behavior. This study aims to give a practical support to researchers and/or professionals who intend to numerically predict the lateral behavior of similar façade systems, so as to avoid or reduce the need of performing expensive experimental tests.