• 제목/요약/키워드: Structural safety test

검색결과 936건 처리시간 0.026초

실험적 기법을 통한 안테나장비 동특성 분석 (Dynamic Characteristics Analysis on Antenna Equipment by Experimental Method)

  • 신준엽;이종학;강영식;최지호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.632-637
    • /
    • 2012
  • Antenna equipment is transported being assembled to moving equipment and often subjected to vibration and shock excitation during transportation. In these circumstances, structural safety of antenna equipment must be secured. Wire rope isolators are assembled between moving equipment and antenna equipment to reduce the level of vibration and shock. In this paper, a isolator that are suitable to the system is selected and dynamic characteristics analysis of driving on antenna equipment is conducted using real system and the result is compared with response analysis. Also modal test of array-antenna pack-assembly is conducted and structural safety of that is secured by reinforcing its structure.

  • PDF

운전석용 하이브리드형 경량 좌석의 개발 (Development of Hybrid Type Automotive Drivers Seat)

  • 김정인;최금호;이병휘;이우일;김희성
    • 한국자동차공학회논문집
    • /
    • 제8권1호
    • /
    • pp.172-182
    • /
    • 2000
  • A hybrid type automotive drivers seat was invented with new concepts for the reduction of weight and manufacturing costs. Fundamental studies were performed to determine the basic geometry of reinforcing support. A prototypical design was provided by the manufacturer considering compatibility with other parts. Several structural analyses simulating various crash situations were performed and modifications were continued until a final design was reached. A sample product was manufactured and sled crash tests were performed to verify the safety of the seat. Comparisons of test results with the previous model and a seat from another company proved safety performances to be superior.

  • PDF

생물생산시설의 구조설계에 관한 연구 (2) 설계하중 산정 및 안전성 검토를 위한 간이법의 개발 (Studies on the Structural Design of Biological Production Facility(2) Simple Methods for Design Load Estimation and Safety Test)

  • 김문기;손정익;남상운
    • 생물환경조절학회지
    • /
    • 제1권2호
    • /
    • pp.148-153
    • /
    • 1992
  • 본 연구는 생물생산시설의 구조설계 과정에서 초기단계의 고정하중을 합리적으로 추정하기 위한 식을 유도하여 구조설계 기준 설정에 기초자료를 제공하고, 생물생산분야 종사자가 간편하게 구조적 안전성을 진단할 수 있는 방법을 개발할 목적으로 수행하였으며 연구 결과를 요약하면 다음과 같다. 1. 국내의 온실설계자료를 수집하여 실제 하중을 산출, 분석해 본 결과 기존의 일본 시설원예기준 적용치와는 차이가 있었으며, 잠정적으로 국내 시설에의 적용을 위한 추정식을 유도하였다. 2. 지역별 설계하중을 적용하여 구조해석을 실시하고, 발생되는 응력의 크기에 따라서 풍하중 및 설하중 지배지역으로 안전설계 지역구분을 실시하였다.

  • PDF

저온조건하 스테인레스 강의 파괴 특성 (Fracture Characteristics of Stainless Steel Under Low Temperature Conditions)

  • 김두환;한석규;안세희
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.108-115
    • /
    • 1999
  • It has been recognized that the mechanical properties of structural steels can be accepted very greatly in a state of normal temperature. While, under low temperature conditions the properties of the structural steels may not be appropriately achieved. When the various and particular structures will be constructed in an intense cold region afterward, the mechanical properties of a stainless steel under low temperature condition must be investigated. The purpose of this paper is to account for the fracture mechanics of structures in the state of low temperatures. The fracture toughness was examined through an experimental test from which the tensile strength and impact values of STS 304 were obtained. In order to demonstrate the present studies, the fracture toughness was compared with the test results for SWS 50 published previously by an author.

  • PDF

저비중 SMC 외장패널의 피로특성 평가 (An Evaluation of the Fatigue Properties for External Panel Using Low Density SMC)

  • 김은성
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.830-835
    • /
    • 2012
  • A research for application of LDSMC(Low Density Sheet Molding Compound) composite is in progress for lightening the weight. This paper has performed fatigue test and simulation of external panel for Korean commercial vehicle. Before the fatigue test, static test was carried out. From the test, the structural safety was investigated using Goodman diagram. After the static test performance, the fatigue test was conducted at a range of load frequency 5Hz, a stress ratio(R) of 0.05 and an endurance limit of $10^6$ to obtain the S-N curve. The S-N curve is applied to the fatigue analysis of the external panel assembly. The result of FEM analysis was in accord with the experimental result within 83% confidence. It showed that the process to set up the safety range of allowable error is required in process of the design and simulation verification.

수소 충전소용 유량제어밸브(FCV)의 구조 및 피로해석을 통한 내구 성능 평가 (Durability Assessment by Structural and Fatigue Analysis of Flow Control Valves (FCVs) for Hydrogen Refueling Stations)

  • 최인호;하태일;김한상
    • 한국수소및신에너지학회논문집
    • /
    • 제33권3호
    • /
    • pp.240-246
    • /
    • 2022
  • This study was conducted to develop a domestic product for a flow control valve for a hydrogen refueling station, and a domestic prototype was manufactured and the durability performance evaluation was conducted through comparison with an imported products. The stress generated by the internal pressure was checked and safety was confirmed using a commercial structural analysis program, ABAQUS, in accordance with the withstand pressure test standards. In addition, after identifying the weak areas the fatigue life was predicted through a commercial software, fe-safe. This fatigue analysis showed that the hydrogen gas repeated test criteria were satisfied.

대차틀의 구조해석 및 하중시험에 관한 연구 (A study on the Structural Analysis and Loading Test of Bogie Frame)

  • 김원경;윤성철
    • 한국철도학회논문집
    • /
    • 제8권6호
    • /
    • pp.566-572
    • /
    • 2005
  • This paper describes the results of structural analysis and loading test of a bogie frame. The purpose of the analysis and test is to evaluate the safety and functionality of the bogie frame under maximum load. The bogie system consist of the bogie frame, suspensions, wheel-sets, a brake system and a transmission system. Of these components, the bogie frame is the major components subjected to the vehicle and passenger loads. The evaluation method used the JIS E 4207 specifications throughout the FEM analysis and static load test. The test results have shown the bogie frame to be safe and stable under design load conditions.

초고온 동압을 밭는 제트 베인의 구조 안전성 평가에 대한 연구 (A Study on Structural Safety Evaluation of let Vane under very High Temperature and Dynamic Pressure)

  • 박성한;이상연;박종규;김원훈;문순일
    • 한국추진공학회지
    • /
    • 제9권3호
    • /
    • pp.18-24
    • /
    • 2005
  • 초고온(2700$^{\circ}C$ ) 연소가스에 직접 노출된 상태에서 가스유동에 의한 동압을 받는 추력편향장치용 제트 베인의 열구조 안전성을 평가하기 위하여 내열합금의 초고온 인장시험 및 3차원 비선형 수치해석을 수행하였다. 고온 구조거동을 분석하여 제트 베인의 구조안전성을 평가하였으며 구조해석결과를 지상 연소시험결과와 비교하였다. 구조 및 열 하중의 대부분은 제트 베인 축에 집중되었으며, 축은 1400$^{\circ}C$ 이하에서 구조적으로 안전한 것으로 밝혀졌다. 지상연소시험결과와 구조해석결과의 비교를 통하여 베인 하중과 축의 변위를 기준으로 구조안전계수를 평가하는 것이 등가응력에 의한 평가기준보다 더 유용한 기준으로 판단되었다.

교차가새형 선행 안전난간을 적용한 시스템비계의 구조 성능 평가 (Structural Capacity Evaluation of System Scaffolding using X-Type Advanced Guardrail)

  • 박주동;이현섭;신우승;권용준;박순응;양승수;정기효
    • 한국안전학회지
    • /
    • 제35권5호
    • /
    • pp.49-58
    • /
    • 2020
  • In domestic construction sites, when installing steel pipe scaffolding and system scaffolding, the guardrails are installed after the installation of the work platforms. This conventional guardrail system (CGS) is always exposed to the risk of falls because the safety railing is installed later. In order to prevent fall disasters during erecting and dismantling scaffolds, it is necessary to introduce the advanced guardrail system (AGS) which installs railings in advance of climbing onto a work platform. For the introduction of the AGS, the structural performance of the system scaffolding applying the CGS and the AGS was compared and evaluated. The structural analysis of the system scaffold (height: 31 m and width: 27.4 m) with AGS confirmed that structural safety was ensured because the maximum stress of each element of the system scaffolding satisfies the allowable stress of each element. As a result of performance comparison of CGS and AGS for each element, the combined stress ratio of vertical posts in AGS was 6.4% lower than that of CGS. In addition, in the case of ledger and transom, the combined stress ratios of AGS and CGS were almost the same. The compression test of the assembled system scaffolding (three-storied, 1 bay) showed that the AGS had better performance than the CGS by 9.7% (8.91 kN). The cross bracing exceeds the limit on slenderness ratio of codes for structural steel design. But the safety factor for the compressive load of the cross bracing was evaluated as meeting the design criteria by securing 3 or more. In actual experiments, it was confirmed that brace buckling did not occur even though the overall scaffold was buckled. Therefore, in the case of temporary structures, it was proposed to revise the standards for limiting on slenderness ratio of secondary or auxiliary elements to recommendations. This study can be used as basic data for the introduction of AGS for installing guardrails in advance at domestic construction sites.

Numerical study on tensioned membrane structures under impact load

  • Zhang, Yingying;Zhao, Yushuai;Zhang, Mingyue;Zhou, Yi;Zhang, Qilin
    • Structural Engineering and Mechanics
    • /
    • 제71권2호
    • /
    • pp.109-118
    • /
    • 2019
  • This paper presents the numerical simulation of membrane structure under impact load. Firstly, the numerical simulation model is validated by comparing with the test in Hao's research. Then, the effects of the shape of the projectile, the membrane prestress and the initial impact speed, are investigated for studying the dynamic response and failure mechanism, based on the membrane displacement, projectile acceleration and kinetic energy. Finally, the results show that the initial speed and the punch shape are related with the loss of kinetic energy of projectiles. Meanwhile, the membrane prestress is an important factor that affects the energy dissipation capacity and the impact resistance of membrane structures.