• Title/Summary/Keyword: Structural member forces

Search Result 155, Processing Time 0.03 seconds

Variations of Column Shortening with Parameters (매개변수에 따른 기둥축소량 변화에 관한 연구)

  • 정은호;김형래
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.59-67
    • /
    • 2000
  • With increased height of structure, the effect of column shortening need special consideration in the design and construction of high-rise buildings. The shortening of each column affects nonstructural members such as partitions, cladding, and M/E systems, which are not designed to carry gravity forces. The slabs and beams will tilt due to the cumulative differential shortening of adeacent vertical members. The main purpose of estimating the total shortening of vertical structural member is to compensate the differential shortening between adeacent members. This paper presents effect of parameters for phenomenon of column shortening in vertical members. The paper presents effect of parameters for phenomenon of column shortening in vertical members. The conclusions obtained from this study are follow as ; Strength of concrete and steel ratio effected on column shortening caused by elastic and inelastic shortening. Also, it is known that Ultimate-shrinkage-Value, Specific-Creep-Value, and volume to surface ratio effected on inelastic shortening only. Particularly, Ultimate-Shrinkage-Value and Specific-Creep-Value effected considerable on the amount of total column shortening.

An Analytical Study on the Bond-Properties of Axial Bars Embedded in Massive Concrete (매시브콘크리트에 배근된 주철근의 부착특성에 관한 해석적 연구)

  • 장일영;이호범;이승훈;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.04a
    • /
    • pp.143-147
    • /
    • 1992
  • Description of the behavior of the R.C structural members fixed on massive concrete is not normally generalization of recognized configuration for regular R.C. design guidanes. This can be due to the complexity of evaluation of internal resistancy and deflection changes of the members subjected to the various external forces. On the base of axially loaded member fixed on footing, however, the estimation of deflection changes due to flexural force shear force and rotational force is to be carried out in ways of specifying the bond characteristics of axial bars embedded in massive concrete. This work is to quantify adhesion of steel-concrete, initial concrete cracking stress near bar rib, maximum bond stress and residual stress in concrete respectively. In addition to quantification of them for particulate behavior, the suggestions of multi-linear bond stress-slip diagram made in carrying out finite element analyses for adhesion failure, examining concrete cracking status and reviewing existing experimental data lead to alternatively constructed relationship between bond stress and slip for a axial bars embedded massive concrete.

  • PDF

Creep Strain of Containment Concrete Structure (원자로 격납건물 콘크리트의 크리이프 변형 특성)

  • 방기성;정원섭;조명석;송영철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.95-100
    • /
    • 1996
  • Creep, drying shrinkage, modulus of elasiticity and Poisson's ratio of concrete are influenced by a number of factors such as mix type, member thickness, curing condition and loading cases. Particularly, creep and shrinkage in concrete have yet to be studied due to its complicated time-dependent properties. In this study, the concrete creep tests were carried out at varous ages of loading-7, 28, 90, 180 and 365 days in order to investigate and quantify its long-term properties. The test procedures and analysis of the test results were also described herein. The results of this study will enable A/E to calculate effective prestressing forces considering time-dependent prestressing loss and evaluate the structural integrity of the prestressing system using the representative values derived from this property test.

  • PDF

Web-shear strength of steel-concrete composite beams with prestressed wide flange and hollowed steel webs: Experimental and practical approach

  • Han, Sun-Jin;Kim, Jae Hyun;Choi, Seung-Ho;Heo, Inwook;Kim, Kang Su
    • Structural Engineering and Mechanics
    • /
    • v.84 no.3
    • /
    • pp.311-321
    • /
    • 2022
  • In the buildings with long spans and high floors, such as logistics warehouses and semiconductor factories, it is difficult to install supporting posts under beams during construction. Therefore, the size of structural members becomes larger inevitably, resulting in a significant increase in construction costs. Accordingly, a prestressed hybrid wide flange (PHWF) beam with hollowed steel webs was developed, which can reduce construction costs by making multiple openings in the web of the steel member embedded in concrete. However, since multiple openings exist and prestress is introduced only into the bottom flange concrete, it is necessary to identify the shear resistance mechanism of the PHWF beam. This study presents experimental shear tests of PHWF beams with hollowed steel webs. Four PHWF beams with cast-in-place (CIP) concrete were fabricated, with key variables being the width and spacing of the steel webs embedded in the concrete and the presence of shear reinforcing bars, and web-shear tests were conducted. The shear behavior of the PHWF beam, including crack patterns, strain behavior of steel webs, and composite action between the prestressed bottom flange and CIP concrete, were measured and analyzed comprehensively. The test results showed that the steel web resists external shear forces through shear deformation when its width is sufficiently large, but as its width decreased, it exerted its shear contribution through normal deformation in a manner similar to that of shear reinforcing bars. In addition, it was found that stirrups placed on the cross section where the steel web does not exist contribute to improving the shear strength and deformation capacity of the member. Based on the shear behavior of the specimens, a straightforward calculation method was proposed to estimate the web-shear strength of PHWF beams with CIP concrete, and it provided a good estimation of the shear strength of PHWF beams, more accurate than the existing code equations.

Resistance of Web-Separated Diagrid Nodes Subjected to Cyclic Loading (반복하중에 대한 웨브전이형 다이아그리드 노드의 구조적 특성)

  • Kim, Young Ju;Jung, In Yong;Ju, Young K.;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.257-266
    • /
    • 2009
  • The results of the analysis of the structural behavior of diagrid nodes that were subjected to cyclic loads such as wind and earthquakes was not fully understood due to difficulties in considering the welding type. In this study, diagrid nodes were tested to determine their behavior when they are subjected to seismic or wind loads. Five specimens were designed and fabricated. The corresponding test parameters were the welding type for each point and the length of the overlap of the side stiffener and the brace web. Tensile force was applied to one diagrid brace member, and compression force was applied to the other diagrid brace member. Cyclic loading was applied until the failure. The test showed that failures are due to axial stress from axial force and the additional bending moment of the two combined axial forces that have different directions. Tensile failure was observed from the tensile force, and local buckling was observed from the compressive force at the flange of the brace member. In addition, the welding type and the length overlap affected the initial stiffness, the yielding stress, and the energy absorption of the diagrid node.

Axial load detection in compressed steel beams using FBG-DSM sensors

  • Bonopera, Marco;Chang, Kuo-Chun;Chen, Chun-Chung;Lee, Zheng-Kuan;Tullini, Nerio
    • Smart Structures and Systems
    • /
    • v.21 no.1
    • /
    • pp.53-64
    • /
    • 2018
  • Nondestructive testing methods are required to assess the condition of civil structures and formulate their maintenance programs. Axial force identification is required for several structural members of truss bridges, pipe racks, and space roof trusses. An accurate evaluation of in situ axial forces supports the safety assessment of the entire truss. A considerable redistribution of internal forces may indicate structural damage. In this paper, a novel compressive force identification method for prismatic members implemented using static deflections is applied to steel beams. The procedure uses the Euler-Bernoulli beam model and estimates the compressive load by using the measured displacement along the beam's length. Knowledge of flexural rigidity of the member under investigation is required. In this study, the deflected shape of a compressed steel beam is subjected to an additional vertical load that was short-term measured in several laboratory tests by using fiber Bragg grating-differential settlement measurement (FBG-DSM) sensors at specific cross sections along the beam's length. The accuracy of midspan deflections offered by the FBG-DSM sensors provided excellent force estimations. Compressive load detection accuracy can be improved if substantial second-order effects are induced in the tests. In conclusion, the proposed method can be successfully applied to steel beams with low slenderness under real conditions.

Evaluation of Buckling Strength of Non-structured Plates by Using the Deformation Energy (변형에너지에 기반한 비정형 판부재의 좌굴강도 평가기법)

  • Zi, Goangseup;Kim, Hong-hyun;Ahn, Jin-young;Oh, Min-Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.3
    • /
    • pp.102-113
    • /
    • 2017
  • A new index for the buckling strength of non-structured plates is proposed. The external work or the deformation energy caused by the external loads or the boundary displacement controled by a load parameter is calculated along an equilibrium path of the member under consideration. If the second variation of the energy with respect to the parameter loses its positiveness, it defined as the limit of the stability. In contrast to the current method given in codes where the stability limit is evaluated by using only representative internal forces, the evaluation of the stability limit is always consistent even with the change of the distribution of the internal forces on the boundary. If the elasticity is concerned, the result from this proposed approach becomes identical to that from the classical methods.

Flexural Analysis of Reinforced Concrete Members Strengthened with FRP Systems Based on Strength Method (FRP 시스템으로 보강한 철근콘크리트 부재의 휨 해석)

  • Cho, Baik-Soon;Kim, Seong-Do;Cheung, Jin-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.2
    • /
    • pp.175-186
    • /
    • 2006
  • Strength method for determining nominal moment capacity of reinforced concrete members is also assumed to be suitable for strengthened members with FRP system. If the internal tensile forces of the strengthened member from steel and FRP is insufficient, the FRP system strain might become greater than its ultimate tensile strain which makes the strength method a contradiction and unapplicable. The experimental results of 27 strengthened beams with carbon fiber sheets which have relatively lower tensile forces from steel and FRP show that not only concrete compressive strain is lower than 0.003 but also measured ultimate moment was lower than nominal moment using the strength method.

Method of Determination of Seismic Design Parameters for the Next Generation of Design Provisions (차세대 내진 설계 규준을 위한 계수 결정 방법)

  • 한상환;이리형
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.04a
    • /
    • pp.88-96
    • /
    • 1995
  • Seismic design provisions in Korea has developed based on seismic provisions in United States (e.g., ATC 3-06). Current seismic design provisions in U .S. is moving toward adopting enhanced concept for design. Federal Emergence Management Agency (FEMA) Provides the NEHRP recommended Provisions for the Development of Seismic Regulations for New Buildings which can be used as a source document for use by any interested members of the building community. Current seismic design provisions in U .S. generally use a uni-level force. These provisions can not be satisfied if the limit state design is concerned. Limit state can be defined as a state causing undesirable performance o( a structure (e .g., serviceability, ultimate, buckling, etc.). Even if there are provision for controlling drift by two levels, it is still difficult to satisfy limit states using uni-level force. Architectural Institute of Japan (AIJ) uses a hi-level forces Int seismic loadings which can satisfy serviceability and ultimate limit state. However, the seismic parameters used in AIJ guideline are basically determined by subjective manner of code committee member and professions. These parameters need to be determined based on target quantities (target reliability, target energy dissipation, target displacement, target stress level, etc.). This study develops the method to determine the sesmic design parameters based on a certain taget level. Reliability is used as a target level and load factors in ANSI/ASCE 7-88 are selected as design parameters to be determined.

  • PDF

Structural Performance Evaluation on Stress-Laminated Timber Bridge Deck Using Finite Element Analysis (유한요소해석을 이용한 응력적층 바닥판의 구조성능평가)

  • Shin, Yukyung;Eom, Chang-Deuk;Lee, Sang-Joon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.20-26
    • /
    • 2014
  • This paper represented the finite element analysis to estimate structural performance of stress-laminated deck, which is determined by deflection, stress, and aging characteristics of tensioning. After loading, the deflected shape showed plate behavior because pre-stressing make frictional force between each member. Compared between initial post-tension and the results, pre-stressing forces were decreased with deck deflection. This is because deflection occurred in the deck so that pre-stressing decreased due to load reduction. However, material plasticity was not considered so that advanced researches should be performed.