• 제목/요약/키워드: Structural Vibration Criteria

검색결과 102건 처리시간 0.033초

APR1400 상부안내구조물집합체 구조해석 및 측정위치 선정 (Structural Analysis and Measuring Locations of Upper Guide Structure Assembly in APR1400)

  • 고도영;김규형;김성환
    • 한국소음진동공학회논문집
    • /
    • 제23권1호
    • /
    • pp.49-55
    • /
    • 2013
  • A reactor vessel internals comprehensive vibration assessment program(RVI CVAP) of an advanced power reactor 1400(APR1400) is being performed as a non-prototype category-2 type of reactor based on the US nuclear regulatory commission regulatory guide(NRC RG) 1.20. The aim of this paper is to present the results of structural response analysis and measuring locations of a upper guide structure(UGS) assembly of the APR1400 reactor. The analysis results of the UGS assembly show that the specified integrity levels meet the design acceptance criteria. Also, the measuring locations are determined by the analysis results of the UGS assembly and selection criteria of previous study. These analysis results and measuring locations will be used as a guide to design a measurement system for the APR1400 RVI CVAP.

APR+원전 최초 호기의 CVAP 수행에 대한 제언 (Proposal for CVAP of First Plant of APR+ NPP)

  • 김동학;고도영;김만원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.399-401
    • /
    • 2014
  • The comprehensive vibration assessment program(CVAP) of APR+ nuclear power plant(NPP) is classified as non-prototype, category II with Palo Verde NPP as valid prototype. In this paper, CVAP for first plant of APR+ NPP is proposed. The Control Element Assembly(CEA) shroud of APR+ NPP is different from that of Palo Verde NPP. And the Core Support Barrel(CSB) outer diameter and the flow rate of normal operation of APR+ NPP are larger than those of Palo Verde NPP. Vibration and stress analysis program should be conducted to establish test acceptance criteria. Limited vibration measurement program should be implemented to establish the margin of safety, demonstrate the satisfaction of test acceptance criteria and confirm the similar vibratory response between the APR+ and Palo Verde NPP. Because of the change of normal operation condition, the nominal differences between APR+ and Palo Verde NPP in the structural and hydraulic analysis are studied to determine the measurement locations.

  • PDF

한국고속철도 천안역사에 대한 소음 및 진동영향 연구 (Noise and Vibration Solutions Considering Stability Effects for High-Speed Rail ChonAn Station in Korea)

  • 권영철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.848-853
    • /
    • 2005
  • The objective of this paper is to address to the providing an adequate noise and vibration solution, required for High Speed Rail while maintaining the stability criteria of the ChonAn station structure, the first constructed in Korean High Speed Railway. The significant acoustic pressure level will be induced by the high speed trains passing-by. Therefore, the high level study of this case is necessary. The acoustic pressure level of 85 dB(A) inside the ChonAn station is expected, and the spaces below concrete slab are not suitable for commercial purpose, thus installation of filtering systems (spring boxes containing viscous dampers, ballast mats and acoustic shield) are provided to reduce the effect of the noise and vibration to acceptable level of 55 dB(A). But, a major drawback of application of the previously conducted experimental results was that the actual effect of installation of filtering system was never been validated. Therefore, the acquisition of noise and vibration on the present structure were obtained and compared to the computer simulations. These predicted the behavior of the station reasonably well. Also, the installation of filtering systems gave the superior reduction on noise and vibration. This application is successfully adapted without scarifying stability criteria related to the structural stability including excessive deformations or displacements. Three traffic operation safety limits: deck vertical acceleration, deflection of the structure, and longitudinal displacement of the slab were satisfactory.

  • PDF

데크 바닥판 구조물의 실용적인 진동해석 (Practical Vibration Analysis of Deck Floor Slab)

  • 김기철
    • 한국전산구조공학회논문집
    • /
    • 제18권1호
    • /
    • pp.61-69
    • /
    • 2005
  • 장경간화되고 경량화된 데크 바닥판 구조물은 부재가 유연하기 때문에 거주자의 움직임에 의하여 진동이 크게 발생할 수 있으며, 이러한 바닥판 진동은 건축물의 안전성뿐만 아니라 건축물의 사용성에도 많은 영향을 끼치므로 건축물의 품질 평가기준으로 사용되고 있다. 데크 바닥판 구조물의 올바른 사용성 평가를 위해서는 정확한 진동해석과 응답평가가 수반되어야한다. 본 논문에서는 데크 바닥판 구조물의 직교이방성을 고려한 여러 가지 모형화 방법을 적용하여 진동해석을 수행하였으며 모형화 방법에 따른 진동응답을 비교 분석하였다. 본 논문에서 제시한 데크 골 방향 강성에 대한 등가두께 모형화방법은 간단한 방법으로 데크 바닥판 구조물의 직교이방성을 간단한 방법으로 고려할 수 있으며, 정확한 진동응답을 얻을 수 있으므로 실무에서 실용적으로 활용할 수 있다.

VIBRATION AND STRESS ANALYSIS OF A UGS ASSEMBLY FOR THE APR1400 RVI CVAP

  • Ko, Do-Young;Kim, Kyu-Hyung
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.817-824
    • /
    • 2012
  • The most important component of a nuclear power plant is its nuclear reactor. Studies on the integrity of reactors have become an important part regarding the safety of a nuclear power plant. The US Nuclear Regulatory Commission Regulatory Guide (NRC RG) 1.20 presents a Comprehensive Vibration Assessment Program (CVAP) to be used to verify the structural integrity of the Reactor Vessel Internals (RVI) for flow-induced vibration prior to commercial operation. However, there are few published studies related to the RVI CVAP. We classified the Advanced Power Reactor 1400 (APR1400) RVI CVAP as a non-prototype category-2 reactor as part of an independent validation of its design. The aim of this paper is to present the results of structural response analyses of the Upper Guide Structure (UGS) assembly of the APR1400 reactor. These results show that the UGS and the Inner Barrel Assembly (IBA) meet the specified integrity levels of the design acceptance criteria. The vibration and stress analysis results in this paper will be used as basic information to select measurement locations of the vibration and stress for the APR1400 RVI CVAP.

선박 추진기계의 진동 계측과 평가(ISO 20283-4) (Measurement and Evaluation of Vibration of the Ship Propulsion Machinery (ISO 20283-4))

  • 이돈출
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.560-564
    • /
    • 2009
  • This paper introduces measurement and evaluation of vibration of the ship propulsion machinery (ISO 20283-4). ISO 20283-2 for measurement of structural vibration on ships was finalized last year and ISO 20283-4 was drafted and reviewed by particulate ISO members now. As the importance and core field in ISO 20283-4, the torsional vibration of propulsion system for sea going vessels should be analysed in design stage and it should be confirmed by the its measurement during the sea trial. Criteria for evaluation of torsional loadings are defined by IACS (International Association of Classification Societies) UR M68. In this paper, the author introduced the important and controversial matters during the review of ISO 20283-4.

  • PDF

Measurement of vibration and stress for APR-1400 reactor internals

  • Ko, Do-Young;Kim, Kyu-Hyung
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.963-970
    • /
    • 2018
  • The U.S. Nuclear Regulatory Commission, Regulatory Guide 1.20 needs to perform a comprehensive vibration assessment program for reactor internals during preoperational and startup testing for nuclear power plants and extended power uprate. Although the measurement program is one of the core programs, it is rarely carried out except for a first-of-a-kind or a unique design. This article describes measurement results of vibration and stress for the comprehensive vibration assessment program for an APR-1400 reactor internals. The measurement was performed at an upper guide structure during the pre-core hot functional test of Shin Kori unit 4 reactor internals because the Shin Kori unit 3 and 4 are the first construction project for the APR-1400, and the upper guide structure assembly was to design change compared with the valid prototype. We confirmed that all measured results are within the test acceptance criteria. It means that the structural integrity of the APR-1400 reactor internals was secured for the flow-induced vibration.

Challenge in the Structural Design of Suzhou IFS

  • Zhou, Jianlong;Huang, Yongqiang
    • 국제초고층학회논문집
    • /
    • 제10권3호
    • /
    • pp.165-171
    • /
    • 2021
  • Core-outrigger-mega frame system is used in Suzhou IFS with 95-story, 450 m-tall, which is beyond Chinese code limit. Besides simple introduction on design principle, structure system and analysis, key techniques including performance based design criteria, frame shear ratio, capacity check of mega column, human comfort criteria under wind induced vibration and TSD design were presented in details for reference of similar super tall building design.

Human-Induced Vibrations in Buildings

  • Wesolowsky, Michael J.;Irwin, Peter A.;Galsworthy, Jon K.;Bell, Andrew K.
    • 국제초고층학회논문집
    • /
    • 제1권1호
    • /
    • pp.15-19
    • /
    • 2012
  • Occupant footfalls are often the most critical source of floor vibration on upper floors of buildings. Floor motions can degrade the performance of imaging equipment, disrupt sensitive research equipment, and cause discomfort for the occupants. It is essential that low-vibration environments be provided for functionality of sensitive spaces on floors above grade. This requires a sufficiently stiff and massive floor structure that effectively resists the forces exerted from user traffic. Over the past 25 years, generic vibration limits have been developed, which provide frequency dependent sensitivities for wide classes of equipment, and are used extensively in lab design for healthcare and research facilities. The same basis for these curves can be used to quantify acceptable limits of vibration for human comfort, depending on the intended occupancy of the space. When available, manufacturer's vibration criteria for sensitive equipment are expressed in units of acceleration, velocity or displacement and can be specified as zero-to-peak, peak-to-peak, or root-mean-square (rms) with varying frequency ranges and resolutions. Several approaches to prediction of floor vibrations are currently applied in practice. Each method is traceable to fundamental structural dynamics, differing only in the level of complexity assumed for the system response, and the required information for use as model inputs. Three commonly used models are described, as well as key features they possess that make them attractive to use for various applications. A case study is presented of a tall building which has fitness areas on two of the upper floors. The analysis predicted that the motions experienced would be within the given criteria, but showed that if the floor had been more flexible, the potential exists for a locked-in resonance response which could have been felt over large portions of the building.

노내시험부 내부집합체에 대한 유체유발진동특성 (Characteristics of flow-induced vibration for inner assembly of in-pile test section)

  • 이한희;이종민;이정영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.250-253
    • /
    • 2006
  • The in-pile Section (IPS) is subjected to flow-induced vibration(FIV) due to the flow of the primary coolant and then the structural integrity. The in-pile Section (IPS) of 3-pin Fuel Test Loop(FTL) shall be installed in the vortical hole call IR1 of HANARO reactor core. In order to verify the velocity and displacement both the inside region of IPS at the annular region of IPS, the vibration was measured by varing the flow rate on both regions. The displacements of fuel assembly in the in-pile Section (IPS) were found to be lower than the values of allowable design criteria.

  • PDF