• 제목/요약/키워드: Structural Excitation Force

검색결과 156건 처리시간 0.021초

Luminescence Properties of InAlAs/AlGaAs Quantum Dots Grown by Modified Molecular Beam Epitaxy

  • Kwon, Se Ra;Ryu, Mee-Yi;Song, Jin Dong
    • Applied Science and Convergence Technology
    • /
    • 제23권6호
    • /
    • pp.387-391
    • /
    • 2014
  • Self-assembled InAlAs/AlGaAs quantum dots (QDs) on GaAs substrates were grown by using modified molecular epitaxy beam in Stranski-Krastanov method. In order to study the structural and optical properties of InAlAs/AlGaAs QDs, atomic force microscopy (AFM) and photoluminescence (PL) measurements are conducted. The size and uniformity of QDs have been observed from the AFM images. The average widths and heights of QDs are increased as the deposition time increases. The PL spectra of QDs are composed of two peaks. The PL spectra of QDs were analyzed by the excitation laser power- and temperature-dependent PL, in which two PL peaks are attributed to two predominant sizes of QDs.

음향 인텐시터법을 이용한 테니스 라켓의 동특성에 관한 연구 (A study on the identification of dynamic characteristics of tennis racket by acoustic intensity method)

  • 오재응;이유엽;염성하
    • 대한기계학회논문집
    • /
    • 제10권5호
    • /
    • pp.601-610
    • /
    • 1986
  • 본 연구에서는 음향학적 고찰로써 최근 디지를 처리기술의 발달에 따른 근접 한 2점의 음압으로 부터 테니스 라켓의 공기입자속도를 근사적으로 구하기 위하여 두 개의 마이크로폰을 이용하여 계산된 음향인텐시티는 구물의 오무드 해석법에 의해 구 해진 테니스 라켓의 동적 특성과 비교 검토함으로써 진동과 음의 발생기구를 구명하고 측정계의 비접촉에 의한 테니스 라켓의 동적 거동을 규명하였다.

Dynamic stability of a viscoelastically supported sandwich beam

  • Ghosh, Ranajay;Dharmavaram, Sanjay;Ray, Kumar;Dash, P.
    • Structural Engineering and Mechanics
    • /
    • 제19권5호
    • /
    • pp.503-517
    • /
    • 2005
  • The parametric dynamic stability of an asymmetric sandwich beam with viscoelastic core on viscoelastic supports at the ends and subjected to an axial pulsating load is investigated. A set of Hill's equations are obtained from the non-dimensional equations of motion by the application of the general Galerkin method. The zones of parametric instability are obtained using Saito-Otomi conditions. The effects of shear parameter, support characteristics, various geometric parameters and excitation force on the zones of instability are investigated.

Role of membrane forces in seismic design of reinforced concrete liquid storage structures

  • Schnobrich, W.C.
    • Structural Engineering and Mechanics
    • /
    • 제10권6호
    • /
    • pp.533-543
    • /
    • 2000
  • To prevent major cracking and failure during earthquakes, it is important to design reinforced concrete liquid storage structures, such as water and fuel storage tanks, properly for the hydrodynamic pressure loads caused by seismic excitations. There is a discussion in recent Codes that most of the base shear applied to liquid containment structures is resisted by inplane membrane shear rather than by transverse flexural shear. The purpose of this paper is to underline the importance of the membrane force system in carrying the base shear produced by hydrodynamic pressures in both rectangular and cylindrical tank structures. Only rigid tanks constrained at the base are considered. Analysis is performed for both tall and broad tanks to compare their behavior under seismic excitation. Efforts are made to quantify the percentage of base shear carried by membrane action and the consequent procedures that must be followed for safe design of liquid containing storage structures.

Piezoelectric shunt damping by synchronized switching on negative capacitance and adaptive voltage sources

  • Qureshi, Ehtesham Mustafa;Shen, Xing;Chen, JinJin
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제15권4호
    • /
    • pp.396-411
    • /
    • 2014
  • Synchronized switch damping (SSD) techniques have recently been developed for structural vibration control using piezoelectric materials. In these techniques, piezoelectric materials are bonded on the vibrating structure and shunted by a network of electrical elements. These piezoelectric materials are switched according to the amplitude of the excitation force to damp vibration. This paper presents a new SSD technique called 'synchronized switch damping on negative capacitance and adaptive voltage sources' (SSDNCAV). The technique combines the phenomenon of capacitance transient charging and electrical resonance to effectively dampen the structural vibration. Also, the problem of stability observed in the previous SSD techniques is effectively addressed by adapting the voltage on the piezoelectric patch according to the vibration amplitude of the structure. Analytical expressions of vibration attenuation at the resonance frequency are derived, and the effectiveness of this new technique is demonstrated, for the control of a resonant cantilever beam with bonded piezoelectric patches, by comparing with SSDI, SSDVenh, and SSDNC techniques. Theoretical predictions and experimental results show the remarkable vibration damping capability of SSDNCAV technique, which was better than the previous SSD techniques. The broadband vibration control capabilities of SSDNCAV technique are also demonstrated, which exceed those of previous SSD techniques.

The study of frictional damper with various control algorithms

  • Mirtaheri, Masoud;Samani, Hamid Rahmani;Zandi, Amir Peyman
    • Earthquakes and Structures
    • /
    • 제12권5호
    • /
    • pp.479-487
    • /
    • 2017
  • Frictional dampers are used in structural engineering as means of passive control. Meanwhile, frictional damper shave a disadvantage compared to viscous rivals since the slippage force must be exceeded to activate the device, and cannot be ideal full range of possible events. The concept of semi-active control is utilized to overcome this shortcoming. In this paper, a new semi-active frictional damper called Smart Adjustable Frictional (SAF) damper is introduced. SAF damper consists of hydraulic, electronic units and sensors which are all linked with an active control discipline. SAF acts as a smart damper which can adapt its slippage threshold during a dynamic excitation by measuring and controlling the structural response. The novelty of this damper is, while it controls the response of the structure in real time with acceptable time delay. The paper also reports on the results of a series of experiments which have been performed on SAF dampers to obtain their prescribed hysteretic behavior for various control algorithms. The results show that SAF can produce the desired slippage load of various algorithms in real time. Numerical models incorporating control simulations are also made to obtain the hysteretic response of the system which agrees closely with test results.

병렬 엔진의 X형 진동 위상 조정에 의한 디젤 발전 플랜트 진동 제어 (Vibration Control on the Diesel Power Plant by the Phase Adjustment of Paralled Engines' X-Mode Vibration;)

  • 이돈출;김의간;전효중
    • 소음진동
    • /
    • 제6권6호
    • /
    • pp.701-708
    • /
    • 1996
  • Diesel power plants are frequently used as a power supplier on the island and the isolated places where electric power is required. The heat efficiency of the low speed 2 stroke diesel engines is higher than those of 4 stroke diesel engines or other heat engines and further its mobility and durability is also better than other engines. They can be also easily repaired and maintained. With these advantages, demand for the use of the low speed 2 stroke diesel engine as a power source is increasing. However, there are some disadvantages with these diesel engines such as the bigger vibrating excitation forces generated by higher combustion pressure in cylinder and by the inertia force of the reciprocating parts. Further, engine vibrations are transfered into their adjacent buildings and manufacturing factories and eventually produces local vibrations. In order to reduce X-mode vibration of engine body, several methods have been introduced in the recent researches. In this paper, accordingly, a new vibrationcontrol method applying a synchrophaser and a top bracing between two diesel engines is adopted in order to reduce these structural vibrations of diesel power plant. It was experimentally verified that the structural vibrations were greatly reduced by the phase adjustment for the 6th order X-mode vibration with the synchrophaser and the top bracing.

  • PDF

분산제어식 응답의존형 MR 감쇠기를 이용한 구조물의 지진응답제어 (Seismic Response Control of Structures Using Decentralized Response-Dependent MR Dampers)

  • 윤경조;민경원;이상현
    • 한국전산구조공학회논문집
    • /
    • 제20권6호
    • /
    • pp.761-767
    • /
    • 2007
  • 건축 및 토목 구조물의 진동 제어분야에서 중앙집중식 제어방식은 주어진 목표응답수준을 만족시키기 위해서 전력공급, 센서, 그리고 감쇠기 등을 포함하는 복잡한 제어시스템을 구축하고 유지하는 노력이 필요하고, 구조물 유한요소모델의 큰차수, 모델의 불확실성, 가력장치의 제한 등의 이유로 적용성의 한계가 있다. 본 논문에서는 센서 혹은 컴퓨터없이 준능동 MR 감쇠기가 설치된 층만의 정보에 의해 제어력이 생성되는 분산제어식 응답의존형 MR 감쇠기가 제안하였다. 제안된 분산제어식 응답의존형 MR 감쇠기는 구조물의 층전단력에 대한 가변마찰력 크기 비의 변화에 따라 지진하중을 받는 구조물의 제어성능이 수동인 경우와 비선형 시간이력해석을 통해 비교 평가되었다. 마지막으로 일반 제어이론에서 널리 이용되는 중앙집중식 LQR 알고리듬과 본 논문에서 제안된 분산제어식 응답의존형 MR감쇠기가 3층 전단형 구조물을 대상으로 수치해석을 통해 비교 평가됨으로써 제안된 알고리즘의 유효성을 검증하였다.

Modeling and experimental verification of phase-control active tuned mass dampers applied to MDOF structures

  • Yong-An Lai;Pei-Tzu Chang;Yan-Liang Kuo
    • Smart Structures and Systems
    • /
    • 제32권5호
    • /
    • pp.281-295
    • /
    • 2023
  • The purpose of this study is to demonstrate and verify the application of phase-control absolute-acceleration-feedback active tuned mass dampers (PCA-ATMD) to multiple-degree-of-freedom (MDOF) building structures. In addition, servo speed control technique has been developed as a replacement for force control in order to mitigate the negative effects caused by friction and inertia. The essence of the proposed PCA-ATMD is to achieve a 90° phase lag for a structure by implementing the desired control force so that the PCA-ATMD can receive the maximum power flow with which to effectively mitigate the structural vibration. An MDOF building structure with a PCA-ATMD and a real-time filter forming a complete system is modeled using a state-space representation and is presented in detail. The feedback measurement for the phase control algorithm of the MDOF structure is compact, with only the absolute acceleration of one structural floor and ATMD's velocity relative to the structure required. A discrete-time direct output-feedback optimization method is introduced to the PCA-ATMD to ensure that the control system is optimized and stable. Numerical simulation and shaking table experiments are conducted on a three-story steel shear building structure to verify the performance of the PCA-ATMD. The results indicate that the absolute acceleration of the structure is well suppressed whether considering peak or root-mean-square responses. The experiment also demonstrates that the control of the PCA-ATMD can be decentralized, so that it is convenient to apply and maintain to real high-rise building structures.

한국표준형 원자력발전소 제어봉집합체 보호구조물의 모우드 특성 (Modal Characteristics of Control Element Assembly Shroud for Korean Standard Nuclear Power Plant(I) : Pre-Test Analysis)

  • 정명조;최순;송희갑;박근배
    • 전산구조공학
    • /
    • 제5권3호
    • /
    • pp.105-112
    • /
    • 1992
  • 원자로 내부구조물의 설계시 필요한 동적응답해석을 위하여 각 구조물의 정확한 진동특성을 파악할 필요가 있다. 한국 표준형 원자력발전소를 위하여 설계된 제어봉집합체 보호구조물은 기존의 설계로 부터 많은 설계변경이 있었고, 또 이 구조물은 튜우브와 얇은 판이 사각격자 형태로 이루어져 있고 연결봉에 의해 고정되는 등 매우 복잡한 형태로 구성되어 있어서 해석과 시험에 의한 진동측정 프로그램을 수행할 필요성이 대두되었다. 따라서 본 논문에서는 진동측정 프로그램의 첫 단계로서 범용구조해석코드인 ANSYS를 이용하여 시험전 해석을 수행하였다. 또 자유도의 수와 얇은 판에 있는 구멍 및 연결봉의 pre-load가 구조물의 자유진동수에 미치는 영향을 검토하였다. 이로부터 결정된 유한요소모델에 대하여 모우드해석을 수행하여 구조물의 고유진동수와 모우드형상을 구하였고, 조화운동해석(Harmonic Analysis)을 행하여 주요모우드에 대한 응답을 측정함으로써 추후에 수행될 진동측정 시험조건 즉 응답측정부위, 측정위치의 수, 측정진동수의 범위 및 가진력의 크기 등을 결정하였다.

  • PDF