• Title/Summary/Keyword: Stroke measurement system

Search Result 97, Processing Time 0.031 seconds

Sensitivity of Hot Film Flow Meter in Four Stroke Gasoline Engine

  • Lee, Gangyoung;Lee, Cha--Myung;Park, Simsoo;Youngjin Cho
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.286-293
    • /
    • 2004
  • The air fuel ratios of current gasoline engines are almost controlled by several air flow meters. When CVVT (Continuous Variable Valve Timing) is applied to a gasoline engine for higher engine performance, the MAP (Manifold Absolute Pressure) sensor is difficult to follow the instantaneous air fuel ratio due to the valve timing effect. Therefore, a HFM (Hot Film Flow Meter) is widely used for measuring intake air flow in this case. However, the HFMs are incapable of indicating to reverse flow, the oscillation of intake air flow has an negative effect on the precision of the HFM. Consequently, the various duct configurations in front of the air flow sensor affect the precision of HFM sensitivity. This paper mainly focused on the analysis of the reverse flow, flow fluctuation in throttle upstream and the geometry of intake system which influence the HFM measurement.

An Experimental Study of T-mode Vibration on the Diesel Power Plant (디젤 발전소의 T-mode 진동에 관한 실험적 고찰)

  • Lee, D.C.;Nam, T.K.;Bae, Y.C.;Kim, Y.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.411-416
    • /
    • 2005
  • Nowadays, diesel power plant using low speed two stroke diesel engine is widely used in islands and restricted areas. Considerations were given to its benefit of high thermal efficiency, reliability and durability compared to the other prime movers. However, various types of engine vibration affect neighboring buildings to their structural vibration. For this, diesel power plant are held liable for the troubles caused by these vibration. These are mainly due to the X- and H-type engine vibrations which we excited by the X- and H- guide force moment. Authors have identified a structural vibration of new pattern called ‘T-mode vibration’ due to the torsional vibration of shafting system. In this paper, T-mode vibration is analyzed through an experimental method based on the global vibration measurement.

  • PDF

Grounding Resistance and Current Characteristics of the Planar Earth Structure using Multiple Discharge Paths (다중방전 경로를 이용한 편상접지체의 접지저항 및 전류특성)

  • Kim, Young-Sun;Kim, Dong-Min;Lee, Ki-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1564-1570
    • /
    • 2016
  • This study proposes a newly modified form of existing ground electrodes in order to secure trust of grounding system for large current caused by a stroke of lightning. Proposed planar earth structure has a several needle electrodes around a circular rod and 4 plane electrodes in all directions. The plane electrodes are fused with the insulator on the linear rod, so that they're electrically isolated. The concept is to increase the discharge amount of earth structure using multiple discharge paths like needle and plane electrodes. To check the discharge efficiency of the suggested scheme, the discharge currents are compared with typically used two kinds of ground rods. To ensure accuracy in the measurement of the discharge current, the same material was used for the comparison model. Also, the ground resistance are simulated by CDEGS commercial software and the results are compared with measured data. Based on this kind of experimental study, the suggested ground rod can be used when designing a ground system or when constructing a ground system at the site.

Design and Implementation of Hadoop-based Big-data processing Platform for IoT Environment (사물인터넷 환경을 위한 하둡 기반 빅데이터 처리 플랫폼 설계 및 구현)

  • Heo, Seok-Yeol;Lee, Ho-Young;Lee, Wan-Jik
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.2
    • /
    • pp.194-202
    • /
    • 2019
  • In the information society represented by the Fourth Industrial Revolution, various types of data and information that are difficult to see are produced, processed, and processed and circulated to enhance the value of existing goods. The IoT(Internet of Things) paradigm will change the appearance of individual life, industry, disaster, safety and public service fields. In order to implement the IoT paradigm, several elements of technology are required. It is necessary that these various elements are efficiently connected to constitute one system as a whole. It is also necessary to collect, provide, transmit, store and analyze IoT data for implementation of IoT platform. We designed and implemented a big data processing IoT platform for IoT service implementation. Proposed platform system is consist of IoT sensing/control device, IoT message protocol, unstructured data server and big data analysis components. For platform testing, fixed IoT devices were implemented as solar power generation modules and mobile IoT devices as modules for table tennis stroke data measurement. The transmission part uses the HTTP and the CoAP, which are based on the Internet. The data server is composed of Hadoop and the big data is analyzed using R. Through the emprical test using fixed and mobile IoT devices we confirmed that proposed IoT platform system normally process and operate big data.

Emission Characteristics of a Passing Two-stroke Scooter using at a Roadside Measurement (도로변 측정을 이용한 2행정 스쿠터의 대기오염물질 배출특성 연구)

  • Woo, Dae-Kwang;Lee, Seung-Bok;Bae, Gwi-Nam;Lim, Cheol-Soo;Kim, Tae-Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.663-671
    • /
    • 2011
  • Although a scooter is a convenient transportation means for a short distance traveling with a light package in the congested urban center, it might be one of the significant sources of air pollutants to which many people can easily be exposed during its passing-by. In this paper, we measured concentrations of gases and particles emitted from a scooter at roadside with no other traffic. To understand the characteristics of scooter emissions with respect to driving speed (idling, 30 km/h) at the roadside, total particle number concentration, particle size distribution, average surface area of particles deposited in the alveolar region, and concentrations of black carbon, CO, and $NO_x$ were measured. The concentrations of the particle number, surface area of deposited particles, CO, and $NO_x$ were highly fluctuated in the scooter's idling condition. The trends of particle number concentration, CO, and $NO_x$ generation were similar to one another. When the scooter started to move, all of $NO_x$, CO and particle number concentrations increased and after it passed by at the speed of 30 km/h, the concentration peaks of the particles and gases appeared at the same time. Unimodal size distribution with ~70 and ~93 nm mode diameters was observed for the idling and cruising condition, respectively. From this work, we found that emission from a passing vehicle could be characterized using a roadside monitoring technique.

The Protective Effects of Sunghyangjeongki-San on Middle Cerebral Artery Occlusion (성향정기산(星香正氣散)이 뇌허혈(腦虛血)을 유발(誘發)시킨 백서(白鼠)의 신경전달물질(神經傳達物質)에 미치는 영향(影響))

  • Yea, Gyeong-Uk;Park, Chi-Sang;Lee, Eun-Ju;Song, Jee-Hea;Kim, Mi-Ryeo;Cho, Jung-Sook;Kim, Young-Ho;Park, Chang-Gook;Yang, Chae-Ha
    • The Journal of Internal Korean Medicine
    • /
    • v.21 no.1
    • /
    • pp.116-125
    • /
    • 2000
  • Objectives : The aim of this study is to investigate that Sunghyangjeongki-San which has been frequently medicated in the early stage of stroke can protect against ischemic damage in rat brain Methods : Extracellular levels of amino acids(glutamate, aspartate, GABA, glycine, taurine, tyrosine, alanine), organic acids(pyruvate, lactate), and cerebral infarction volume were measured at the striatum of rats subjected to permanant focal cerebral ischemia induced by 2 hours of middle cerebral artery occiusion(MCAO). Rats were orally administered with Sunghyangjeongki-San at 30mins before MCAO and the microdialysate was collected by intracerebral microdialysis three times before MCAO and six times after MCAO at 20mins interval and analyzed by HPLC. After a microdialysis study, the brain was sliced and stained with cresyl violet buffer for the measurement of cerebral infarcted area and volume by image analyzer system Results : The concentrations of glutamate, aspartate, and tyrosine known as excitatory neurotransmitters were significantly decreased in Sunghyangjeongki-San group compared with control group, The concentrations of GABA, glycine, taurine and alanine known as inhibitory neurotransmitters were significantly increased in Sunghyangjeongki-San group compared with control group. The concentrations of pyruvate and lactate showed little significant change in Sunghyangjeongki-San group compared with control group. The measurement of cerebral infarcted area and volume by image analyzer system were significantly decreased in Sunghyangjeongki-San group compared with control group. Conclusions : Sunghyangjeongki-San can affect on protecting against cerebral ischemia by regulating extracellular levels of excitatory and inhibitory amino acid neurotransmitters and improve the conditions of the patients in the early stage of stroke.

  • PDF

A Study on Grip Force and Angular Kinematics during Golf Putting Stroke (그립악력과 각운동학을 이용한 골프 퍼팅 분석)

  • Choi, Jin-Seung;Kim, Hyung-Sik;Lim, Young-Tae;Yi, Jeong-Han;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.125-131
    • /
    • 2007
  • The purpose of this study was to evaluate the difference in grip force and angular kinematic variables between elite (handicap${\leq}2$) and novice golfers. Three-dimensional motion analysis system with synchronized grip force measurement system was used. The participants consisted of two groups based on their playing ability: 10 elite golfers and 10 novice golfers. Each subject performed 5 putting strokes at the distance of 1, 3, and 5m with randomly selected order. During entire putting phase, elite group showed relatively constant grip force but novice group showed continuously increasing grip force pattern. There existed a clear difference in the trajectory of shoulder line between two groups. As for novice group the rotational center did not converge into one point, for elite group the rotational center converged into precise single point. And there was a clear difference pattern in anterior-posterior directional movement at shoulder between two groups. These difference might be helpful for improving consistent putting skills.

A Study on the Development of a Lightning Warning System by the Measurement of Electric Field at the Ground (대지전장측정에 의한 뇌경보시스템 개발에 관한 연구)

  • Kil, Gyung-Suk;Lee, Sung-Keun;Song, Jae-Yong;Kim, Jum-Sik;Kwon, Jang-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.250-258
    • /
    • 2001
  • In this study, a lightning warning system (LWS) which can predict a lightning return stroke is developed, and the LWS is based on the measurement of electric field intensity at the ground level. The LWS consist of a rotation-type field mill as an electric field sensor, an impedance changer, a two-stage amplifier, and a microprocessor unit. From the calibration experiment, the frequency bandwidth and the maximum resolution of the LWS are $DC{\sim}200\;[Hz]$ and 73 [V/m], respectively. Also, the LWS can measure the electric field strength caused by a thunderstorm up to 18.7 [kV/m] at the ground. To ensure the sensing ability of the developed LWS in an actual situation, computer simulation using thundercloud models was carried out, and the result showed that the LWS can monitor the movement of thunderclouds within 6 [km] from the observation site.

  • PDF

A Practical standard Air Flow Generator System to Calibrate and Compare Performance of Two Different Respiratory Air Flow Measurement Modules (호흡기류 계측모듈의 교정과 성능 비교를 위한 실용적인 표준기류 생성 시스템)

  • Lee, In-Kwang;Park, Mi-Jung;Lee, Sang-Bong;Kim, Kyoung-Ok;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.115-122
    • /
    • 2015
  • A standard air flow generator system was developed to generate air flows of various levels simultaneously applied to two different air flow transducer modules. Axes of two identical standard syringes for spirometer calibration were connected with each other and driven by a servo-motor. Linear displacement transducer was also connected to the syringe axis to accurately acquire the volume change signal. The user can select either sinusoidal or square waveform of volume change and manually input any volume as well as maximal flow rate levels ranging 0~3 l and 0~15 l/s, respectively. Various volume and flow levels were input to operate the system, then the volume signal was acquired followed by numerical differentiation to obtain the air flow signal. The measured volumes and maximal air flow rates were compared with the user input data. The relative errors between the user-input and the measured stroke volumes were all within 0.5%, demonstrating very accurate driving of the system. In case of the maximal flow rate, relatively large error was observed when the syringe was driven very fast within a very short time duration. However, except for these few data, most measured flow rates revealed relative errors of approximately 2%. When the measure and user-input stroke volume and maximal flow rate data were analyzed by linear regression analysis, respectively, the correlation coefficients were satisfactorily higher than 0.99 (p < 0.0001). These results demonstrate that the servo-motor controls the syringes with enough accuracy to generate standard air flows. Therefore, the present system would be very much practical for calibration process as well as performance evaluation and comparison of two different air flow transducer modules.

Implementation of Motion Analysis System based on Inertial Measurement Units for Rehabilitation Purposes (재활훈련을 위한 관성센서 기반 동작 분석 시스템 구현)

  • Kang, S.I.;Cho, J.S.;Lim, D.H.;Lee, J.S.;Kim, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 2013
  • In this paper, we present an inertial sensor-based motion capturing system to measure and analyze whole body movements. This system implements a wireless AHRS(attitude heading reference system) we developed using a combination of rate gyroscope, accelerometer and magnetometer sensor signals. Several AHRS modules mounted on segments of the patient's body provide the quaternions representing the patient segments's orientation in space. We performed 3D motion capture using the quaternion data calculated. And a method is also proposed for calculating three-dimensional inter-segment joint angle which is an important bio-mechanical measure for a variety of applications related to rehabilitation. To evaluate the performance of our AHRS module, the Vicon motion capture system, which offers millimeter resolution of 3D spatial displacements and orientations, is used as a reference. The evaluation resulted in a RMSE of 2.56 degree. The results suggest that our system will provide an in-depth insight into the effectiveness, appropriate level of care, and feedback of the rehabilitation process by performing real-time limbs or gait analysis during the post-stroke recovery process.

  • PDF