• Title/Summary/Keyword: Strip technique

Search Result 185, Processing Time 0.022 seconds

Slender RC columns strengthened with combined CFRP and steel jacket under axial load

  • Lu, Yi-yan;Li, Na;Li, Shan;Ou, Tian-yan
    • Steel and Composite Structures
    • /
    • v.19 no.5
    • /
    • pp.1077-1094
    • /
    • 2015
  • This paper presents an experimental study on the effectiveness of simultaneous application of carbon fiber-reinforced polymer (CFRP) and steel jacket in strengthening slender reinforced concrete (RC) column. The columns were 200 mm square cross section with lengths ranging from 1600 to 3000 mm. Ten columns were tested under axial load. The effects of the strengthening technique, slenderness ratio, cross-section area of steel angle and CFRP layer number were examined in terms of axial load-axial strain curve, CFRP strain, steel strip strain and steel angle strain. The experiments indicate that strengthening RC columns with combined CFRP and steel jacket is effective in enhancing the load capacity, ductility and energy dissipation capacity of RC column. Based on the existing models for RC columns strengthened with CFRP and with steel jacket, a design formula considering a slenderness reduction factor is proposed to predict the load capacity of the RC columns strengthened with combined CFRP and steel jacket. The predictions agree well with the experimental results.

Medpor Craniotomy Gap Wedge Designed to Fill Small Bone Defects along Cranial Bone Flap

  • Goh, Duck-Ho;Kim, Gyoung-Ju;Park, Jae-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.3
    • /
    • pp.195-198
    • /
    • 2009
  • Objective : Medpor porous polyethylene was used to reconstruct small bone defects (gaps and burr holes) along a craniotomy bone flap. The feasibility and cosmetic results were evaluated. Methods : Medpor Craniotomy Gap Wedges, V and T, were designed. The V implant is a 10 cm-long wedge strip, the cross section of which is an isosceles triangle with a 4 mm-long base, making it suitable for gaps less than 4 mm after trimming. Meanwhile, the Medpor T wedge includes a 10 mm-wide thin plate on the top surface of the Medpor V Wedge, making it suitable for gaps wider than 4 mm and burr holes. Sixty-eight pterional craniotomies and 39 superciliary approaches were performed using the implants, and the operative results were evaluated with respect to the cosmetic results and pain or tenderness related to the cranial flap. Results : The small bone defects were eliminated with less than 10 minutes additional operative time. In a physical examination, there were no considerable cosmetic problems regarding to the cranial bone defects, such as a linear depression or dimple in the forehead, anterior temporal hollow, preauricular depression, and parietal burr hole defect. Plus, no patient suffered from any infectious complications. Conclusion : The Medpor Craniotomy Gap Wedge is technically easy to work with for reconstructing small bone defects, such as the bone gaps and burr holes created by a craniotomy, and produces excellent cosmetic results.

A Subminiature Antenna for Bluetooth Applications (블루투스용 초소형 안테나)

  • Park, Myoung-Shil;Chun, Ren;Bang, Jai-Hoon;Ahn, Bierng-Chearl
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.4
    • /
    • pp.119-125
    • /
    • 2007
  • In this paper, a miniaturized PCB-integrated antenna is proposed for bluetooth applications. The proposed antenna is a modified form of the printed inverted F antenna where the size reduction is achieved by employing the meander strip for the resonant length part of the radiator. The antenna dimension is optimized using the commercial electromagnetic software MWSTM. The designed antenna is fabricated by the standard photo-etching technique and its performance is measured. The fabricated antenna shows a bandwidth of 125MHz centered at 2.45GHz and a gail of -0.23dBi. The size of the proposed antenna is $9.65mm{\times}5.95mm$ corresponding to the 55 percent of the area of the existing printed inverted F antenna.

  • PDF

Design of Self Magnetization MsS Sensor Using Crossed Coils (Crossed-Coils를 이용한 자기자화 MsS센서의 설계)

  • Kim, Yi-Gon;Park, Kyung-Jo;Moon, Hong-Sik;Kim, Jae-Hyun;Ahn, Hyun-Jin;Kang, Woo-Seok;Oh, Un-Kyung
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.6
    • /
    • pp.856-862
    • /
    • 2008
  • This paper propose a advanced technique for exciting and receiving the guided torsional wave to detect flaws in pipe systems. There are some difficulties in selecting and exciting of modes by using the nickel strip attached on pipe systems, such as qualification of residual magnetic field and multi-exciting of the unwanted modes etc. In order to there difficulties we propose the new sensor, so called Crossed-coils sensor. We will prove that it is possible to select the modes to be excited and to find a optimal excitation condition for torsional mode by using the proposed sensor.

Recovery of Golden yellow and Cibacron LSG dyes from aqueous solution by bulk liquid membrane technique

  • Muthuraman, G;Ali, P. Jahfar
    • Membrane and Water Treatment
    • /
    • v.3 no.4
    • /
    • pp.243-252
    • /
    • 2012
  • Tri-n-butyl phosphate (TBP) was used as carrier for the transport of Golden yellow and Cibacron LSG dyes through a hexane bulk liquid membrane. The transport efficiency of dyes by TBP was investigated under various experimental conditions such as pH of the feed phase (dyes solution), concentration of the receiving phase (NaOH solution), concentration of TBP in membrane, rate of stirring, effect of transport time, type of solvent, dye concentration in feed phase, effect of temperature.. The maximum transport dyes occurs at ratio of 1:1 TBP-hexane At pH 3.0 0.1 (feed phase) the transport dyes decreased. At high stirring speed (300 rpm) the dyes transport from the feed phase to the strip phase was completed within 60 minutes at $27^{\circ}C$. Under optimum conditions: Feed phase 100 mg/L dyes solution at pH 1.0 0.1, receiving phase 0.1 mol/L NaOH solution, membrane phase 1:1 TBP-hexane , Stirring speed 300 rpm and temperature $27^{\circ}C$, the proposed liquid membrane was applied to recover the textile effluent.

Reinforcing Effect of Cohesionless Slope by Reticulated Root Piles (비점착성 사면의 그물식 뿌리말뚝의 보강효과)

  • Yoo, Nam-Jea;Park, Byung-Soo;Choi, Jong-Sang
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.7-16
    • /
    • 1998
  • This paper is an experimental study of investigating the reinforcing effect and the behavior of cohesionless slope installed with reticulated root pils. Reduced scale model tests with plane strain conditions were performed to study the behavior of the strip footing located on the surface of cohesionless slopes reinforced with root piles. Model tests were carried out with Jumunjin Standard Sand of 45% relative density prepared by raining method to have an uniform slope foundation during tests. Slope of model foundation was 1 : 1.5 and a rigid model slop. Parametric model tests were performed with changing location of model footing, arrangements of root piles and angles of pile installation. On the other hands, the technique with camera shooting was used to monitor sliding surface formed with discontinuty of dyed sand prepared during formation o foudation. From test results, parameters affecting the behavior of model footing were analyzed qualitatively to evaluate their effects on the characteristic of load - settlement, ultimate bearing capacity of model footing and failure mechanism based on the formation of failure surface.

  • PDF

Characteristics of AE Signals from Plant according to the Environmental Variation (식물의 환경 변화에 따른 음향방출의 신호특성)

  • Nam, Ki-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.198-204
    • /
    • 2003
  • A basic experiment was performed to control tile plant growth using acoustic emission technique considering the environmental conditions for plant. At a dry soil condition, the signals due to the cavitation from xylem of angiosperm and gymnosperm were mainly detected. The strong signal from xylem and the weak signal from plasmodesmata and casparian strip were detected at the same time after distilled water was provided. Two signals after providing tile acid and distilled water were contrary to each other. The wind, number of leaf, music, temperature and humidity affected the acoustic emission count from plants but the frequency ranges of the detected signals were the same.

Development of Feature Points Detection Algorithm for Measuring of Pulse Wave Velocity (맥파 전달 속도(PWV) 측정을 위한 특징점 검출 알고리즘 개발)

  • Choi, Jung-Hyeon;Cho, Wook-Hyun;Park, Jun-Ho;Kim, Nam-Hoon;Seong, Hyang-Sook;Cho, Jong-Man
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.343-350
    • /
    • 2011
  • The compliance and stiffness of artery are closely related with disease of arteries. Pulse wave velocity(PWV) in the blood vessel is a basic and common parameter in the hemodynamics of blood pressure and blood flow wave traveling in arteries because the PWV is affected directly by the conditions of blood vessels. However, there is no standardized method to measure the PWV and it is difficult to measure. The conventional PWV measurement has being done by manual calculation of the pulse wave transmission time between coronary arterial proximal and distal points on a strip chart on which the pulse wave and ECG signal are recorded. In this study, a pressure sensor consisting of strain gauges is used to measure the blood pressure of arteries in invasive method and regular ECG electrodes are used to record the ECG signal. The R-peak point of ECG is extracted by using a reference level and time windowing technique and the ascending starting point of blood pressure is determined by using differentiation of the blood pressure signal and time windowing technique. The algorithm proposed in this study, which can measure PWV automatically, shows robust and good results in the extraction of feature points and calculation of PWV.

On the Suitable Shape of Bottom for the Application of Air Cavity on Hull Bottom to the Practical Hull Form (선저부 공기공동을 이용한 실선선형의 저항성능 개선을 위한 선저형상 개량연구)

  • Seok-Cheon Go;Hyo-Chul Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.3
    • /
    • pp.1-7
    • /
    • 1999
  • This paper describes the modification of hull bottom for the air lubrication technique to the passenger boat in service at the Chung-Ju lake, which has a large beam-draft ratio. From numerical analysis of 2-D cavity problem by potential theory, the cavity shape, length and the pressure in cavity are estimated for the simplified geometry of hull bottom, and the non-dimensional parameters affecting air cavity phenomena are investigated. Extensive resistance tests for the model ship which has variation of step height and side strip have been performed to investigate the formation of air cavity and the drag reduction effectiveness. And also, the development of attached cavity to the bottom were observed from the flat bottom made by transparent acrylic plate. From this survey on the modification of bottom shape and the air lubrication technique, the total resistance of model ship could be reduced by about 25% at the design speed compared to the proto type hull form.

  • PDF

Comparison of Cardiac Output Determination by Direct Fick and Thermodilution Method in Man (인체에서 Pick 원리 및 열희석법에 의한 심박출량 측정의 비교 연구)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.14 no.3
    • /
    • pp.228-234
    • /
    • 1981
  • Measurement of cardiac output by thermodilution method is easy to perform and can be repeated at very short intervals and offers a number of theoretical and practical advantages. The purpose of this paper is to reevaluate the accuracy and reproducibility of the thermodilution cardiac output by comparing the results with those obtained by the direct Fick technique. From January through April 1981 [4 months], 26 simultaneous cardiac output measurements were made using thermodilution and direct Fick methods in 12 patients in the intensive care unit of Severance Hospital following open heart surgery. The average age of the patients was $34.8{\pm}12.0$ [SD] years [range; 17-57 years]. For cardiac output determination by thermodilution technique [$CO_TD$], a Swan-Ganz Thermodilution Catheter, Model 93A-131-7F [Edwards Laboratories], a Cardiac Output Computer, Model 9520A, and Strip Chart Recorder, Model 9810 [Edwards Laboratories] were used. For the determination of cardiac output by direct Fick principle [$CO_Fick$], a Van Slyke Manometric Apparatus [Thomas] for the measurements of arteriovenous oxygen content difference and a Collin`s Respirometer with Kymograph for the measurement of oxygen consumption were used. The correlation between the simultaneously measured $CO_TD$ and $CO_Fick$ was found to be $CO_Fick$ = 0.95.$CO_TD$ + 0.1073, [r= 0.9777, P < 0.001 ]. For 26 double or triple determinations of $CO_TD$, the values ranged from 1.77 L/min to 6.66 L/min, with a reproducibility of 2.18%. The maximum difference of $CO_TD$ for $CO_Fick$ was between +11.99% and -12,99% [$Mean{\pm}SD$ = $6.07{\pm}3.97$%]. Measurement of cardiac output by thermodilution method provides a simple, rapid, reproducible and highly accurate method for multiple cardiac output measurements suitable for use at the bedside. Comparison of Cardiac Output Determination by Direct Fick and Thermodilution Method in Man.

  • PDF