• Title/Summary/Keyword: Strip Line

Search Result 388, Processing Time 0.025 seconds

Characteristics of Linearly Tapered Coupled Strip-Line Filters (선형테이퍼 결합 Strip 선로의 여파특성)

  • 박기수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.9 no.2
    • /
    • pp.1-16
    • /
    • 1972
  • In this paper, the characteristics of linearly tapered strip-line filters, where the even-mode and odd-mode characteristic impedances vary linearly with the same degree along the lines, are analyzed. The Impedance parameters of linearly tapered coupled strip-line, which is made by connecting two linearly tapered unsymmetric coupled strip-lines In cascade and the I:no input and output terminals are made equal, are obtained. Using the above parameters, the Image parameters of linearly tapered coupled strip-line filters are derived. The result of analysis shows that the line length can be made shorter and also the stop-band width between the fundamental and second pass-band becomes wider, compared with the coupled strip-line filters which use uniform strip-lines. Furthermore, the difference of impedance levels in the fundsmental and second pass-band becomes larger with the degree of taper of the lines. This property is unique, in comparison with the case of uniform or exponentially tapered strip-line filters.

  • PDF

Development of the Strip Off-center Meter Using Line Scan Camera in FM Line (라인 스캔 카메라를 이용한 압연라인의 판쏠림 측정장치 개발)

  • Yoo Ki-Sung;Lee Min-Choel;Choi Yong-Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.6
    • /
    • pp.518-523
    • /
    • 2005
  • Strip off-center is one of the major problems in hot strip mill line. The key to good centering is having good equipment, modern control systems, excellent maintenance and an understanding of milling process. Therefore, this study aims to develop a system that is useful for quantitative analysis of strip off-center. In this study, the measuring method of strip off-center was thoroughly studied and the exclusive control board to line scan camera were designed. Also, the manipulated type housing for line scan camera was developed to adjust initial parameters for strip width and center line. In order to check the accuracy and usefulness of the developed system, FM stand in $\#2$ Hot Strip Factory in Pohang Steel Works was targeted.

Analysis and Experiment of Micro-strip Line Lumped Elements for SAW Duplexers (탄성표면파 듀플렉서용 마이크로 스트립라인 집중소자 해석 및 실험)

  • 이승희;노용래
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.1
    • /
    • pp.85-92
    • /
    • 2002
  • In this study, we analyzed and experimented micro-strip line inductors and capacitors for a SAW duplexer, an important devise for mobile communication. For SAW duplexers, micro-strip line lumped elements must have small impedance values, below several tens of nH or several tens of pF, and a small area pattern. In this study, we performed theoretical analysis of flat line type, meander line type, and spiral line type inductors and interdigital capacitors on a LiTaO$_3$ Piezo-crystal. We proposed a measurement method to evaluate small values of lumped elements accurately with network analyzer. In experiments, we confirmed validity of the theoretical analysis method through fabrication and characterization of micro-strip line lumped elements. The analysis method in this paper can be applied to SAW duplexers well as other microwave devices.

Design of Body RF Coil with Multiple Strips for Open MRI System by Pseudo Electric Dipole Radiation

  • 김경락;류승학;류연철;양형진;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.76-76
    • /
    • 2002
  • Purpose: The purpose of this study is to optimize the configuration of body RF coil composed of 4 planar subcoils for low field open MRI. Method: Our low field RE coil is composed of 4 subcoils assumed to be located at both the bottom and top sides of permanent magnet. Each subcoils has 3 main strips. The coil system has mirror inversion symmetry. First, the currents on the strips are obtained by inductance calculation and circuit analysis, Second, all the strips are divided into line strip elements across the strips, the self Inductances of line strip elements and the mutual inductances among the line strip elements are calculated, and current distributions of strip are obtained by circuit analysis, where each strip is considered as parallel combination of line strip elements. Finally all the line strip elements are segmented, magnetic field has been calculated by pseudo electric dipole radiation method, where the current elements are regarded as pseudo electric dipole radiation sources. We have performed above procedures for various configurations of RE coil. The field homogeneity is calculated in the 25 cm DSV.

  • PDF

FE-based Strip Mean Temperature Prediction On-Line Model in Hot Strip Finishing Mill by using Dimensional Analysis (차원해석을 통한 열간 사상압연중 온도해석모델 개발)

  • 이중형;곽우진;황상무
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.176-179
    • /
    • 2003
  • The mean temperature prediction of strip is very important in hot strip finishing mill because of affecting on product quality and shape. Also, temperature can be used by basic information in other on-line control models with affecting control accuracy in factory. So, FE based on-line temperature model was developed for predicting strip mean temperature accurately in various process conditions and factory environments. There are many variables in affecting strip mean temperature in on-line states of factory. But some problems are occurred in considering all variables for making temperature model because of the bad efficiency of regression or fitting analysis. In this report, we have adopted dimensional analysis for solving these problems. We have many variables with dimensions affecting strip temperature but we are able to make non-dimensional variables less than dimensional variables from the combination of dimensional variables caused by PI-Theorem in fluid mechanics. The developed models are divided by two parts. The one is interstand temperature prediction model. The other is roll gap temperature model.

  • PDF

Tension Control Using On-Line Compensation of Friction Loss for Continuous Strip Processing Line (연속 공정 라인의 실시간 마찰손 보상을 통한 장력 제어 특성 개선)

  • Lee, Jeong-Uk;Choi, Chang-Ho;Hyun, Dong-Seuk
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.10
    • /
    • pp.701-707
    • /
    • 2000
  • This paper proposes a tension control to compensate friction loss using on-line friction torque observer for a continuous strip processing line. Friction loss of roller results in significant deviation of strip tension, accordingly it has an influence on the operation of other adjacent rolls. To avoid tension variation of the strip, a friction torque observer is designed in adjacent roll, which operates in speed control mode. The observed torque is added to the torque limit reference of the pay-off reel for on-line compensation of both friction loss and acceleration/deceleration torque at the same time. The simulation and experimental results show improvement of tension control performance by the proposed friction compensation method.

  • PDF

HOT STRIP WIDTH CONTROL METHOD BY USING LOOPER TENSION MEASURING SYSTEM IN FINISHING MILL (열간 사상압연 투퍼장력 측정에의한 열연판폭제어)

  • 홍완기;김필호;문영훈;이준정
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.423-428
    • /
    • 1999
  • A high precision hot strip width control method has been developed in this study by applying interstand looper tension measuring system at finishing mill stands. As with deviation of hot rolled steel strip is closely related to abnormal increase in the interstand strip tension, on-line measuring device of looped tension and data analyzing system was developed in this study. To determine dominant factors that will cause local width shortage, the logged data sets of bar width, bar thickness, looper tension, and strip thickness along the strip length were correlated with the data set of strip width change. With the result of the correlation analysis, existing sequence control logic and parameters for looper actuator were modified for strip width quality and the gains of the looper control were refined for the stable operation during the full passage of rolled strip. The on-line tension measurement and tension feedback control for looper system improved strip travelling stability and reduced strip width deviation in the srip top end region.

  • PDF

A Consideration of Open End & Step Discontinuity Effects for Suspended Strip Line (Suspended Strip Line의 Open End 및 Step 불연속 효과에 대한 고찰)

  • Jeon, Yong-Ku;Yang, Seung-In
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.12
    • /
    • pp.146-151
    • /
    • 2008
  • The equivalent circuits of Open End and Step discontinuity effects for Suspended Strip line are obtained. The circuit parameters for each discontinuity effect are represented by equations after optimization based on EM analysis results, and the coefficients of the equations are obtained by curve fitting for all impedance cases.

Improvement of Power Capability and Field Uniformity with Tapered Coaxial Matching Units in Strip Line for Measuring Electromagnetic Immunity of Vehicular Components

  • Chung, Yeon-Choon;Kang, Tae-Won;Park, Dong-Chul
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.5
    • /
    • pp.60-64
    • /
    • 1997
  • The design process and construction method of a strip line is described for measuring radiated susceptibility of vehicular components having electrical cables more than 2 min length. he characteristic impedance of the trip line was determined 90$\Omega$ to obtain the field uniformity of $\leq$${\pm}$3 dB in the frequency range from 100 kHz to 500 MHz. Tapered coaxial lines were used instead of the traditional lumped circuit element for the impedence matching units, therefore, the strip line has high power capability. Using these techniques, the field uniformity and power capability of a strip line could be considerably improved.

  • PDF

Design of Adaptive Inverse Control for Center Position Control of Steel-Strip in Continuous Annealing Line (연속소둔로에서 판중심 위치 제어를 위한 적응 역비례 제어기의 설계)

  • Kim, Young-Su;Jo, Sung-Eun;Lee, Young-Kow;Kim, Sang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.608-610
    • /
    • 2004
  • In continuous annealing line (CAL), POSCO, the center position control (CPC) is an essential technique that renders the steel-strip to pass at the center of a roll in order to prevent the strip from skewing or breaking. The CPC algorithm currently installed on the steering roll in the heating section of CAL is to control the strip position by using the reverse phase of error from the center position, without considering the dynamics of strip horizontal movement. Such algorithm may, unfortunately, require a manual operation occasionally when the range of strip input becomes wide, causing the dynamics 0 be dominant. Other PID-type control is rarely used in automatic operation because the excess of response may occur when the discontinuous points such as welding joints pass through rolls. In this paper, we identify the CPC system by using off-line data and design a compensator for the excessive dynamics by using the adaptive inverse control. Simulation result depicts the improved reliability of the proposed CPC system.

  • PDF