• Title/Summary/Keyword: Stretches

Search Result 110, Processing Time 0.025 seconds

Characterization of Lupinus Iuteus Chloroplgsl Gene Coding for Components of a Chloroplastic NADH Dehydrogenase

  • Oczkowski, Marian;Augustyniak, Halina
    • Journal of Plant Biotechnology
    • /
    • v.2 no.2
    • /
    • pp.73-78
    • /
    • 2000
  • The plastid genomes of several plants contain ndh genes homologues of genes encoding subunits of the mitochondrial complex I. We sequenced the part of lupin ndhB, ndhD and ndhF genes in order to compare the structure of these genes with those of Nicotiana tabaum, Arabidopsis thaliana, Zea mays and Oryza sativa with the idea to detect the presence of stretches with identical aminoacid composition. We were only able to find one or two stretches of this kind of about 16 aminoacid- long in the analyzed fragments of the ndh genes. The total number of such stretches was different in particular gene products: for ndhc 1, ndhB 9, ndhD 3 and ndhF 6. We have also examined the transcription pattern of ndhC, ndhK and ndhJ genes during lupin development. We show that the greatest amount of ndhC, ndhK and ndhJ transcripts are observed in 7- to 14 day- old lupin seedlings. We also studied the level of transcription of those genes in plants growing at low temperature. All the data confirmed that the abundance of transcription of ndhC, ndhK, and ndhJ genes increased under chill conditions. It has to be noted that the level of transcription of the ndhC gene was higher than the other genes probably due to higher stability of this transcript.

  • PDF

Development of Stretchable Joint Motion Sensor for Rehabilitation based on Silver Nanoparticle Direct Printing (은 나노입자 프린팅 기반의 재활치료용 신축성 관절센서 개발)

  • Chae, Woen-Sik;Jung, Jae-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.183-188
    • /
    • 2021
  • Objective: The purpose of this study was to develop a stretchable joint motion sensor that is based on silver nano-particle. Through this sensor, it can be utilized as an equipment for rehabilitation and analyze joint movement. Method: In this study, precursor solution was created, after that, nozel printer (Musashi, Image master 350PC) was used to print on a circuit board. Sourcemeter (Keithley, Keithley-2450) was used in order to evaluate changes of electric resistance as the sensor stretches. In addition, the sensor was attached on center of a knee joint to 2 male adults, and performed knee flexion-extension in order to evaluate accurate analysis; 3 infrared cameras (100 Hz, Motion Master 100, Visol Inc., Korea) were also used to analyze three dimensional movement. Descriptive statistics were suggested for comparing each accuracy of measurement variables of joint motions with the sensor and 3D motions. Results: The change of electric resistance of the sensor indicated multiple of 30 times from initial value in 50% of elongation and the value of electric resistance were distinctively classified by following 10%, 20%, 30%, 40% of elongation respectively. Through using the sensor and 3D camera to analyze movement variable, it showed a resistance of 99% in a knee joint extension, whereas, it indicated about 80% in flexion phase. Conclusion: In this research, the stretchable joint motion sensor was created based on silver nanoparticle that has high conductivity. If the sensor stretches, the distance between nanoparticles recede which lead gradual disconnection of an electric circuit and to have increment of electric resistance. Through evaluating angle of knee joints with observation of sensor's electric resistance, it showed similar a result and propensity from 3D motion analysis. However, unstable electric resistance of the stretchable sensor was observed when it stretches to maximum length, or went through numerous joint movements. Therefore, the sensor need complement that requires stability when it comes to measuring motions in any condition.

Immediate Effects of Stretching on Hamstring Stiffness (넙다리뒤근육에 대한 스트레칭이 근육의 뻣뻣함에 미치는 즉각적 효과)

  • Kim, Joong-Hwi;Kim, Tae-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose: Stretching exercises are commonly used in conjunction with sports and rehabilitation. Weassessed the immediate effects of stretching on passive stiffness of the hamstring muscles and knee range of motion (ROM) using three stretching techniques. Methods: A total of 45 participants were recruited. Isokinetic equipment was used to measure the passive stiffness of hamstring muscles and an inclinometer was used to measure active and passive ROM of the knee joint pre and post stretching. Stiffness was then calculated based on the incline of the torque-angle relationship. The test conditions for Group I were $3{\times}30$ seconds of static stretches using the hamstring muscle, Group II were $3{\times}30$ seconds of static stretches using the hamstring muscle with ankle dorsiflexion, and Group IIII had $3{\times}30$ seconds of active stretching. Results: Group II had significantly higher excursion of active ROM and Group IIIhad significantly higher excursion of passive muscle stiffness. All of the groups had significantly higher active and passive ROM and significantly lower muscle stiffness after stretching. The participants showed no change in hamstring muscle stiffness on the following day. Conclusion: Stretching has significant acute effects on ROM and muscle stiffness and canbe used in warm-up protocols for reducing muscle stiffness before a variety of exercise programs.

A Methocarbamol Combination to Prevent Toxicity of Non-steroidal Anti Inflammatory Drugs (비스테로이드성 항염증제의 약물독성 예방을 위한 Methocarbamol의 약물조합)

  • Yeom, Seung-Min;Kim, Min-Seok;Lingenfelter, Eric;Broadwell, Jonathan
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.2
    • /
    • pp.88-98
    • /
    • 2017
  • To prevent toxicity from both robax platinum (methocarbamol, ibuprofen) and robaxacet (methocarbomol, acetaminophen), separately, we used stretches and naproxen as a non-steroidal anti-inflammatory drug (NSAID) to compare each effectiveness. This study used the United States Forces Korea Prescription form (Annex A-Over-The-Counter Prescription) and Alice Rich's Pain scale with robax platinum, robaxacet including narproxen. The IBM SPSS statics version 24 was used to calculate the data. The combined methocarbamol 500 mg, acetaminophen 325 mg tablet, and ibuprofen 200 mg (or naproxen) tablet can work as well as the combined methocarbamol 500 mg tablet with acetaminophen 325 mg tablet with stretches. Both methods were successful in managing pain. The drug combination of methocarbamol 500 mg, acetaminophen 325 mg and ibuprofen 200 mg tablets yielded similar benefits as the methocarbamol 500 mg and acetaminophen 325 mg tablets paired with physical stretching exercises regarding managing overall pain.

Prosodic Features at "Sentence Boundaries" in Oral Presentations

  • Umesaki, Atsuko-Furuta
    • MALSORI
    • /
    • no.41
    • /
    • pp.83-96
    • /
    • 2001
  • It is generally said that falling intonation is used at the end of a declarative sentence. However, this is not the case with all stretches of spontaneous speech which are marked in transcription as sentences. The present paper examines intonation patterns appearing at the end of declarative sentences in oral presentations, and discusses instances where falling intonation does not appear. The texts used for analysis are eight oral presentations collected at international conferences in the field of physics. Quantitative and qualitative analyses are carried out. Three major factors related to discourse structure have been found for non-occurrence of falling intonation at sentence boundaries.

  • PDF

Prosodic Features at "Sentence Boundaries" in Oral Presentations

  • Umesaki, Atsuko-Furuta
    • Proceedings of the KSPS conference
    • /
    • 2000.07a
    • /
    • pp.149-164
    • /
    • 2000
  • It is generally said that falling intonation is used at the end of a declarative sentence. However, this is not the case with all stretches of spontaneous speech which are marked in transcription as sentences. The present paper examines intonation patterns appearing at the end of declarative sentences in oral presentations, and discusses instances where falling intonation does not appear. The texts used for analysis are eight oral presentations collected at international conferences in the field of physics. Quantitative and qualitative analyses are carried out. Three major factors related to discourse structure have been found for nonoccurrence of falling intonation at sentence boundaries.

  • PDF

Effects of hamstring self-stretches on pelvic mobility in persons with low back pain

  • Park, Dae-sung;Jung, Seung-hwa
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.3
    • /
    • pp.140-148
    • /
    • 2020
  • Objective: The purpose of this study was to examine the effectiveness of pelvic displacement when self-hamstring muscle stretches were applied to persons with low back pain. Design: Three-group pretest-posttest design. Methods: Forty persons with low back pain participated in this study. Pelvic tilt angle, hamstring flexibility, Quadruple Visual Analogue Scale (QVAS), Fear Avoidance Beliefs Questionnaire (FABQ), Korea version of the Oswestry Disability Index (KODI) and pelvic mobility were measured at pre-post. All participants were divided into either the pevic anterior tilt group (PAT group, n=12), pelvic midrange group (PMR group, n=18), or the pelvic posterior tilt group (PPT group, n=10). Self-stretching was performed using the pilates ring three times a week for a total of four weeks and the post-test was conducted and compared with the pre-test. Results: Hamstring flexibility, QVAS, KODI scores were significantly different compared to before the intervention (p<0.05). The changes in hamstring flexibility of the three groups were significantly different (p<0.05). Changes in KODI and FABQ results of the three groups were not significant. The pelvic posterior tilt range were significantly different in the PMR and PPT groups (p<0.05). The pelvic anterior tilt ranges showed significant differences after stretching in the PPT group (p<0.05). Conclusions: A large amount of change of hamstring flexibility, pelvic mobility of anterior and posterior tilt test in the PPT group was observed. Furthermore, therapists should consider pelvic displacement of the participant when applying intervention, which may, accordingly, have different effectiveness.

Infrared Multiphoton Dissociation Spectroscopy of Protonated 1,2-Diaminoethane-water Clusters: Vibrational Assignment via the MP2 Method

  • Boo, Bong Hyun;Kang, Sukmin;Furuya, Ari;Judai, Ken;Nishi, Nobuyuki
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3327-3334
    • /
    • 2013
  • Infrared multiphoton dissociation (IRMPD) spectra of various protonated 1,2-diaminoethane-water clusters DAE-$H^+-(H_2O)_n$ (n = 1-6) were measured in the wavelength range of 3000-3800 $cm^{-1}$. The IRMPD spectra of the well separated ionic clusters were simulated by the MP2 method employing various basis sets. Comparison of the IRMPD spectra with the theory indicates that each cluster may exist as several low-lying conformers, and the sum spectra of the various conformers reveal almost one to one correspondence between theory and experiment. Free N-H and O-H stretches are observed in the ranges of 3400-3500 and 3600-3800 $cm^{-1}$, respectively. The $O-H{\cdots}N$ and $N-H{\cdots}O$ stretches are, however, observed in the broad region of 3000-3600 $cm^{-1}$. The theoretical calculations on DAE-$H^+-(H_2O)_n$ (n = 1-4) show gradual decrease of the average binding energy between DAE-$H^+$ and $H_2O$ as the cluster size increases, attaining the lowest value of 55 kJ/mol when n = 4. We found a low energy barrier of 21 kJ/mol to the isomerization converting the lowest energy cluster of DAE-$H^+-(H_2O)_n$ to the second lowest one.

Effect of Prior Muscle Contraction or Passive Stretching on Eccentric-Induced Muscle Damage

  • Choi, Seung-Jun
    • PNF and Movement
    • /
    • v.17 no.3
    • /
    • pp.487-497
    • /
    • 2019
  • Purpose: This tutorial review investigated the effect of prior fatigue and passive stretches on eccentric contraction-induced muscle injuries, as well as the underlying mechanisms of eccentric contraction-related injuries. Methods: Contraction-induced muscle damage is the most common disabling problem in sports and routines. The mechanisms underlying the pathology and prevention of muscle damage lessened by prior fatigue or stretches are critical in assessing musculoskeletal injuries. Even though there are treatments to reduce eccentric contraction-induced muscle injuries, fatigue negatively influences them. Therefore, we reviewed previous studies on eccentric contraction-induced muscle injuries with prior treatments using the MEDLINE and PubMed databases. Results: Prior passive stretching had a preventative and therapeutic effect, but prior lengthening contractions did not. On the other hand, prior isometric contractions involving relatively small forces may not provide a sufficient stimulus to induce protection. As a result, high force isometric contractions may be necessary. The studies supported the positive effects of prior fatigue, concluding that it was a factor in determining the amount of damage caused by eccentric exercise. This was due to a reduction in force and increased temperature. Studies that did not support the positive effects of prior fatigue concluded that a shift in optimal length to a longer length and reduced energy absorption during lengthening are evidence that fatigue is not related to muscle injuries induced by lengthening. Conclusion: The variability of the experiment models, conditions, muscles, and treatment methods make it necessary to interpret the conditions of previous studies carefully and draw conclusions without making direct comparisons. Thus, additional studies should be carefully conducted to investigate the positive effect of fatigue on lengthening.

A Study on the Bottom Design of Petaloid Carbonated PET Bottle to Prevent Bottom Crack (탄산음료용 PET병의 바닥면 크랙방지를 위한 Petaloid 디자인)

  • Shin H. C.;Lyu M. Y.;Kim Y. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.154-157
    • /
    • 2001
  • Through this study we investigated the causes of bottom crack. We then redesigned petaloid bottom to prevent bottom crack. We examined the material property variations according to the stretch ratio of PET and analyzed stretches of bottom in blowing processes. We also performed crack test to observe a crack phenomena. The effective stress and maximum principal stress were examined by computer simulation. We concluded that the bottom crack occurs because of not only insufficient strength of material due to the insufficient stretch of PET but also coarse design of petaloid shape. The highest maximum principal stress occurred at valley in petaloid bottom of bottle and this strongly affected the crack in bottom. We redesigned petaloid shape to minimize maximum principal stress, and this result in increasing the crack resistance.

  • PDF