• 제목/요약/키워드: Stress-Strength Analysis

검색결과 2,232건 처리시간 0.029초

Mechanical model for analyzing the water-resisting key stratum to evaluate water inrush from goaf in roof

  • Ma, Kai;Yang, Tianhong;Zhao, Yong;Hou, Xiangang;Liu, Yilong;Hou, Junxu;Zheng, Wenxian;Ye, Qiang
    • Geomechanics and Engineering
    • /
    • 제28권3호
    • /
    • pp.299-311
    • /
    • 2022
  • Water-resisting key stratum (WKS) between coal seams is an important barrier that prevents water inrush from goaf in roof under multi-seam mining. The occurrence of water inrush can be evaluated effectively by analyzing the fracture of WKS in multi-seam mining. A "long beam" water inrush mechanical model was established using the multi-seam mining of No. 2+3 and No. 8 coal seams in Xiqu Mine as the research basis. The model comprehensively considers the pressure from goaf, the gravity of overburden rock, the gravity of accumulated water, and the constraint conditions. The stress distribution expression of the WKS was obtained under different mining distances in No. 8 coal seam. The criterion of breakage at any point of the WKS was obtained by introducing linear Mohr strength theory. By using the mechanical model, the fracture of the WKS in Xiqu Mine was examined and its breaking position was calculated. And the risk of water inrush was also evaluated. Moreover, breaking process of the WKS was reproduced with Flac3D numerical software, and was analyzed with on-site microseismic monitoring data. The results showed that when the coal face of No. 8 coal seam in Xiqu Mine advances to about 80 m ~ 100 m, the WKS is stretched and broken at the position of 60 m ~ 70 m away from the open-off cut, increasing the risk of water inrush from goaf in roof. This finding matched the result of microseismic analysis, confirming the reliability of the water inrush mechanical model. This study therefore provides a theoretical basis for the prevention of water inrush from goaf in roof in Xiqu Mine. It also provides a method for evaluating and monitoring water inrush from goaf in roof.

고준위방사성폐기물 처분시설 부지에 대한 암반역학 부지특성화 (Rock Mechanics Site Characterization for HLW Disposal Facilities)

  • 엄정기;현승규
    • 자원환경지질
    • /
    • 제55권1호
    • /
    • pp.1-17
    • /
    • 2022
  • 암반의 역학적 및 열적 특성은 고준위방사성폐기물(high-level radioactive waste; HLW) 심지층 처분시스템 내 방사성 물질의 격리 및 이동 지연 능력과 관련된 성능에 영향을 미칠 수 있다. 이 연구는 HLW 처분시설 부지의 암반역학적 및 열적 특성과 관련된 부지설명모델에 필수적인 항목을 고찰하고 스웨덴과 핀란드의 선행 부지설명모델 사례를 통한 기술적 배경을 논의하였다. 스웨덴 SKB (Swedish Nuclear and Fuel Management Company)와 핀란드 Posiva는 암반역학적 및 열적 특성 조사·평가에 필수적인 항목을 제시하고 부지의 안전성 분석과 처분시설의 건설을 위한 암반역학 부지설명모델을 도출하였다. 암반역학 부지설명모델은 처분시설 부지 내 응력 분포와 더불어 신선암, 절리, 절리성 암반에 대한 강도 및 변형특성과 대규모 변형대의 기하학적 구조, 소규모 불연속면의 연결망 구조 및 암석의 열적 특성에 대한 조사·평가 결과를 포함한다. 또한, 암반역학 부지설명모델은 입력변수에 대한 민감도 분석결과와 입력변수의 불확실성에 대한 평가 결과를 제시하여야 한다.

단계석션압 조건에 따른 석션보드드레인 공법의 효율 분석 (Analysis of Efficiency of Suction Board Drain Method by Step Vacuum Pressure)

  • 김기년;한상재;김수삼
    • 대한토목학회논문집
    • /
    • 제28권6C호
    • /
    • pp.321-329
    • /
    • 2008
  • 본 연구에서는 전통적인 압밀촉진공법의 단점을 보완하기 위한 방법으로 석션보드드레인 공법을 제안하고, 본 공법의 개량특성을 파악하기 위해, 배수재 종류 및 단계 진공압 조건에 따른 일련의 Column 실험을 실시하였다. 이때 실험 간 발생되는 침하량과 실험 종료 후 발생된 함수비 저감효과 및 강도증진효과를 파악하고, 개량 기간에 따른 압밀도를 파악하여 각 조건에 따른 최적의 석션보드드레인 공법 영향인자를 산정하고자 하였다. 각 배수재(포켓식 성곽형, 코일형, 하모니카 형, 원형 및 열융착식 성곽형배수재) 종류에 따른 개량 효과를 파악하기 위한 실험 결과, Core 형상(원형, 판형)과 필터의 Core 부착 여부(포켓식, 열융착식)에 의해 열융착식 성곽형 배수재와 포켓식 원형배수재의 배수효율이 다른 배수재의 경우 보다 좋게 나타났다. 단계석션압 조건 실험의 경우 최종 단계석션압인 $-0.8\;kg/cm^2$으로의 기간이 짧을수록 개량도가 크게 나타났다. 또한 각 석션압 단계 별 압밀도-적용기간 곡선 상의 변곡점을 이용하여 압밀효과를 극대화 시킬 수 있는 적용기간을 산정할 수 있었다.

현행(現行) 허용응력설계법(許容應力設計法)으로 설계(設計)되는 RC 휨부재(部材)의 신뢰성(信賴性)과 안전율(安全率) 고찰(考察) (An Investigation of Reliability and Safety Factors in RC Flexural Members Designed by Current WSD Standard Code)

  • 신현묵;조현남;정환호
    • 대한토목학회논문집
    • /
    • 제1권1호
    • /
    • pp.33-42
    • /
    • 1981
  • 현행(現行) 철근(鐵筋)콘크리트 표준시방서(標準示方書)는 WSD와 USD의 재래적(在來的)인 두 가지 설계편(設計編)으로 구성(構成)되어 있는데 이들 설계기준(設計基準)은 ACI 318-63 및 318-71 Code에 기초를 두고 있다. 이와 같이 주로 ACI 318-63 시방서(示方書)에 기초를 둔 우리의 WSD와 USD의 안전율(安全率)은 우리의 설계(設計) 및 시공실무(施工實務)에 비(比)해 부적절(不適切)한 것으로 받아들여지고 있다. 더구나 ACI의 안전율(安全率)도 확률적(確率的)으로 결정(決定)된 것이 아니고 주로 경험(經驗)과 현실성(現實性)을 고려하여 결정(決定)된 것이다. 본(本) 연구(硏究)는 현행(現行) 허용응력설계(許容應力設計) 안전율규정(安全率規定)으로 설계(設計)되는 휨 부재(部材)의 안전수준(安全水準)을 2차(次)모멘트 신뢰성이론(信賴性理論)에 의해 고찰(考察)하고, 일관성(一貫性)있는 목표신뢰성(目標信賴性)을 제공(提供)하는 철근(鐵筋) 및 콘크리트의 공칭안전율(公稱安全率)과 휨 허용응력(許容應力)을 합리적(合理的)이고도 효율적(效率的)으로 결정(決定)하는 방법(方法)을 제안(提案)하였다. Cornell의 제(第)1계(階) 이차(二次)모멘트법(法)을 하중(荷重)과 저항(抵抗) 결과변화(結果變化)의 대수변환(對數變換)에 의해 적용(適用)하는 방법(方法)을 본(本) 연구(硏究)의 신뢰성해석법(信賴性解析法)으로 사용하였다. 최적(最適) 철근비(鐵筋比)를 갖는 극한강설계(極限强設計)의 과소철근(過少鐵筋)보에 대응하는 균형철근비(均衡鐵筋比)로 설계(設計)되는 균형단면(均衡斷面)이 되도록 하는 독특한 방법으로 콘크리트의 허용압축응력(許容壓縮應力)을 유도하였다. 우리의 시공(施工) 및 설계실무(設計實務)의 수준(水準)에 적합(適合)한 ${\beta}_0=4$를 안전율(安全率) 결정(決定)을 위한 목표신뢰성지수(目標信賴性指數)로 택하였다. 현행(現行) WSD 시방서(示方書)로 설계(設計)되는 RC 휨 부재(部材)의 안전(安全) 및 신뢰성(信賴性)을 여러 수치계산(數値計算)을 통해 고찰(考察)해본 결과(結果), 현행(現行) WSD 기준(基準)에 의한 설계(設計)는 비정당적(非定當的)이며 일관성(一貫性)없는 신뢰성(信賴性)으로 인하여 비경제적(非經濟的)인 설계(設計)도 된다는 사실(事實)을 알 수 있었다. 적절(適切)한 목표신뢰성지수(目標信賴性指數) ${\beta}_0=4$에 따른 휨 부재(部材)의 철근(鐵筋)과 콘크리트의 합리적(合理的)인 허용응력(許容應力)을 본(本) 연구(硏究)의 신뢰성이론(信賴性理論)에 의해 제안(提案)하였다.

  • PDF

차세대 웨어러블 디바이스를 위한 높은 기계적/전기적 특성을 갖는 CNT-Ni-Fabric 유연기판 (CNT-Ni-Fabric Flexible Substrate with High Mechanical and Electrical Properties for Next-generation Wearable Devices)

  • 김형구;노호균;차안나;이민정;하준석
    • 마이크로전자및패키징학회지
    • /
    • 제27권2호
    • /
    • pp.39-44
    • /
    • 2020
  • 최근 웨어러블 장치에 적용하기 위한 유연성 기판에 대한 연구가 활발히 진행되고 있다. 특히, 유연성 기판 중 의복에 웨어러블 장치를 적용하기 위한 전도성 섬유기판에 대한 연구가 진행되고 있다. 본 연구에서는, 면섬유 기판 표면에 CNT와 Pd복합 용액을 스프레이 법을 이용하여 형성하였고, 무전해 도금법을 이용하여 금속층을 도금하였다. 도금된 섬유기판의 형상을 분석하기 위하여 SEM 장비를 이용하였고, CNT를 증착한 섬유기판의 표면에 Ni 레이어가 형성된 것을 확인하였다. EDS 분석을 통하여 섬유기판의 표면에 형성된 물질이 Ni임을 알 수 있었다. 전기적 특성을 확인하기 위하여 4-point probe로 무전해 도금을 진행한 섬유기판의 표면저항 및 저항 분포를 확인하기 위한 맵핑을 진행하였다. 무전해 도금의 진행 시간이 길어질수록 전도성이 향상되었음을 확인할 수 있었고, 표면 위치 별 저항의 분포가 균일함을 알 수 있었다. 인장력, 굽힘, 뒤틀림 시험을 통하여 기계적 스트레스로 인한 저항변화를 측정하였다. 그 결과 도금 시간이 길어질수록 유연성 기판의 저항변화가 점점 사라지는 것을 확인하였다. UTM(Universal testing machine)을 이용하여 도금시간 변화에 대한 무전해 도금 기판의 기계적 특성 향상 여부에 대하여 분석하였다. 인장강도는 무전해 도금을 2 시간 동안 진행한 전도성 섬유기판의 경우, 면섬유 기판보다 약 16 MPa 증가하였다. 이러한 결과들을 토대로 Ni-CNT-Fabric 유연기판은 의류 일체형 전도성 기판으로 이용되기에 충분함을 확인하였고, 이러한 연구 결과는 유연기판, 웨어러블 디바이스뿐만 아니라 유연성이 필요한 배터리, 촉매, 태양전지 등에 적용되어 발전에 기여할 수 있을 것으로 기대한다.

현장시험과 Class-A 및 C1 type 수치해석을 통한 강관매입말뚝의 거동에 대한 연구 (A Study on the Behaviour of Prebored and Precast Steel Pipe Piles from Full-Scale Field Tests and Class-A and C1 Type Numerical Analyses)

  • 김성희;정경자;정상섬;전영진;김정섭;이철주
    • 한국지반환경공학회 논문집
    • /
    • 제18권7호
    • /
    • pp.37-47
    • /
    • 2017
  • 본 연구에서는 강관매입말뚝의 하중-침하 및 전단응력 전이 특성을 분석하기 위하여 시험시공 및 수치해석을 수행하였다. 동재하시험 및 정재하시험을 수행한 결과 EOID 및 Restrike 시험을 통해 평가된 말뚝의 설계지지력은 정재하시험에서 평가된 설계 지지력에 비해 각각 약 56~105% 및 65~121%의 범위를 보였으며, 말뚝재하시험 이전에 수행된 Class-A type 수치해석의 경우 38~142%의 범위를 보였다. 또한 Restrike 시험에서 평가된 설계지지력은 EOID 시험의 설계지지력에 비해 12~60% 증가된 것으로 평가되었다. EOID에서는 선단지지력이 크게 측정되는 데 비해, Restrike 시험에서는 주면마찰력이 크게 측정되었는데 Restrike 시험의 타격에너지가 충분하지 않은 경우 말뚝의 선단지지력이 과소평가될 가능성이 있는 것으로 분석되었다. 본 연구의 분석에 의하면 동재하시험을 통해 말뚝의 지지력을 합리적으로 평가하기 위해서는 주면지지력은 Restrike 시험 결과를, 선단지지력은 EOID 시험 결과를 적용하는 것이 합리적인 것을 알 수 있었다. 정재하시험 실측값과 수치해석으로부터 예측된 하중-침하 관계는 탄성범위까지는 어느 정도 유사하지만 항복이 발생한 이후의 거동은 크게 벗어났다. 즉 실측값은 항복 이후 경화현상이 거의 없이 마치 탄성-완전소성(elastic-perfectly plastic) 재료와 유사하게 파괴에 도달되는 반면에, 수치해석에서는 변형경화(strain hardening)과정을 거치면서 파괴에 점진적으로 도달되는 경향을 보였다. 말뚝의 하중-침하 특성은 지반의 강성에 영향을 받으며, 축력분포는 지반의 전단 강도상수에 영향을 받는 것으로 나타났다.

벤토나이트 완충재 설계 기준 온도에 따른 고효율 처분시스템 처분 간격 및 암반 조건 산정을 위한 수치해석적 연구 (A Numerical Analysis to Estimate Disposal Spacing and Rock Mass Condition for High Efficiency Repository Based on Temperature Criteria of Bentonite Buffer)

  • 김광일;이창수;김진섭;조동건
    • 터널과지하공간
    • /
    • 제31권4호
    • /
    • pp.289-308
    • /
    • 2021
  • 본 연구에서는 열-수리-역학적 복합거동 수치해석을 활용하여 국내 고준위방사성폐기물 처분장의 완충재의 설계 기준 온도가 100℃ 및 125℃인 경우, 처분 간격에 따른 처분시스템의 최고 온도를 계산하고, 역학적 안정성을 확보하기 위한 암반의 조건을 도출하였다. 완충재의 설계 기준 온도를 현재와 같이 100℃로 유지할 때, 처분터널 간격이 40 m, 처분공 간격이 5.5 m인 경우와 처분터널 간격이 30 m, 처분공 간격이 6.5 m인 경우, 처분용기와 완충재가 접하는 점에서 최고 온도가 각각 99.4℃ 및 99.8℃로 계산되었다. 완충재의 설계 기준 온도를 125℃로 향상시킨 경우, 처분터널 간격을 30 m, 처분공 간격을 4.5 m까지 감소시켜 처분 면적을 KRS+ 기반 처분시스템 대비 55%까지 감소시킬 수 있었다. 다양한 처분 간격에 대해 암반에서의 역학적 안정성을 평가한 결과, 암반파괴가 발생하지 않기 위해서는 KRS+ 기반 처분시스템은 암반의 RMR 분류법의 Good rock에 해당하는 RMR 72.4 이상의 조건이어야 했다. 처분 간격이 감소할수록 암반의 RMR이 더 높아야 했으며, 처분터널 간격 30 m, 처분공 간격 4.5 m인 경우에는 RMR 87.3 이상이 되어야 암반의 파괴를 방지할 수 있었다. 그러나, 처분 이후 지하수 유입 시 벤토나이트 완충재 및 뒤채움재의 팽윤에 따른 구속압에 의한 암반 강도의 증가를 고려하면, 해석을 수행한 모든 처분 간격에 대해 암반의 RMR이 75 이상이면 역학적 안정성을 확보할 수 있었다.

마이크로 머시닝을 위한 고농도로 붕소가 도핑된 실리콘 층의 부정합 전위의 억제 (Suppression of misfit dislocations in heavily boron-doped silicon layers for micro-machining)

  • 이호준;김하수;한철희;김충기
    • 전자공학회논문지A
    • /
    • 제33A권2호
    • /
    • pp.96-113
    • /
    • 1996
  • 고농도로 붕소가 도핑된 실리콘층 내에 존재하는 부정합 전위는 웨이퍼 가장자리에서 발생됨을 알았으며, 이 층을 도핑되지 않은 영역으로 둘러쌓음으로써 부정합 전위가 억제된 고농도로 붕소가 도핑된 실리콘층을 형성할 수 있었다. 이를 이용하여 부정합 전위가 없는 고농도로 붕소가 도핑된 실리콘 멤브레인을 제작하였으며, 이 멤브레인의 표면 거칠기 및 파괴 강도 그리고 잔류 인장 응력을 각각 20$\AA$ 1.39${\times}10^{10}dyn/cm^{2}$ 그리고 2.7${\times}10^{9}dyn/cm^{2}$로 측정되었다. 반면에 부정합 전위를 포함하는 기존 멤브레인은 각각 500$\AA$ 8.27${\times}10^{9}dyn/cm^{2}$ 그리고 9.3${\times}10^{8}dyn/cm^{2}$로 측정되었으며, 두 멤브레인의 이러한 차이는 부정합 전위에서 기인함을 알았다. 측정된 두 멤브레인의 Young's 모듈러스는 1.45${\times}10^{12}dyn/cm^{2}$로 동일하게 나타났다. 또, 도핑 농도 1.3${\times}10^{12}dyn/cm^{3}$에 대한 고농도로 붕소가 도핑된 실리콘의 유효 격자 상수 및 기존 멤브레인의 평면적 격자 상수 그리고 기존 멤브레인 내의 부정합 전위의 밀도는 각각 5.424$\AA$ 5.426$\AA$ 그리고 2.3${\times}10^{4}$/cm 로 추출되었으며, 붕소가 도핑된 실리콘의 부정합 계수는 1.04${\times}10^{23}$/atom으로 추출되었다. 한편 별도의 추가적인 공정없이 일반적인 에피 성장법을 사용하여 고농도로 붕소가 도핑된 실리콘층 위에 부정합 전위가 없는 에피 실리콘을 성장시켰으며, 이 에피 실리콘의 결정성은 매우 양호한 것으로 밝혀졌다. 또 부정합 전위가 없는 에피 실리콘에 n+/p 게이트 다이오드를 제작하고 그 전압-전류 특성을 측정한 결과 5V의 역 바이어스에서 0.6nA/$cm^{2}$의 작은 누설 전류값을 나타내었다.

  • PDF

동·서양 해자(垓字)의 역사와 문화적 해석 (An Historical and Cultural Analysis on the Eastern and Western Moat)

  • 정용조;심우경
    • 한국전통조경학회지
    • /
    • 제29권1호
    • /
    • pp.105-120
    • /
    • 2011
  • 해자란 성벽 외곽에 파 놓은 못 또는 물길로 적이 성벽에 직접 접근할 수 없도록 하거나 이를 경계로 공간을 구분하고자 설치된 시설의 하나로, 고대로부터 중세에 이르기까지 동 서양에서 존재하였으나 현재는 사라져 가고 있다. 그러나 군사적 방어 기능으로부터 공간을 구분하는 경계 수단으로, 지반을 다지는 중요한 역할을 하였으며, 역사적으로 고대로부터 중세, 유럽, 아시아, 미국 등에서 존재하였다. 또한 해자는 물을 이용한 다양한 문화 활동과 동물들의 서식처 장소를 제공하는 등 역사와 문화적 가치가 큰 공간임에도 불구하고, 복원 계획에 있어 해자의 복원에 대한 고려가 미비한 실정이다. 본 연구는 동 서양 해자의 역사와 문화적 의미를 해석하여 고대로부터 중세에 이르기까지 존재했던 해자 문화에 대한 이해를 높이고자 하는 연구로 해자의 기원, 시대적 고찰, 사상적 배경, 서양 해자의 역사와 문화, 동양의 한국, 중국, 일본 해자에 대하여 분석한 결과는 다음과 같다. 1. 우리나라의 해자는 고구려 도성뿐만 아니라 신라, 백제의 도성에 모두 존재하였으며, 천연의 해자인 넓은 강을 끼고 적들이 기어오르기 힘든 산 능선을 따라 성을 쌓은 자연적 해자와 성벽 밖에 인공적 해자를 설치하여 적의 접근을 방지하였다. 또한 고려시대와 조선시대에도 해자를 방어적 기능으로 활용하였다. 2. 해자의 설치는 성벽에서 일정한 간격을 두고 넓고 깊게 파는 것이 보통이며, 성의 외곽에만 있는 것이 아니라 내부에도 시설이 설치되었는데, 성 밖에 있는 해자는 방어력을 높이는 것 외에도 지반을 다지는데 중요한 역할을 하였다. 또한 해자는 물이 있어 접근을 제한하며, 낮은 벽이나 담장은 경계를 물리적으로 분리시키지만 해자는 열린 공간으로 시각적 특성을 살려 경계 및 방어 수단을 가지면서 멀리 떨어진 산봉우리나 근처의 나무도 정원 안으로 차경할 수 있게 한다. 3. 낙안읍성은 풍수지리적으로 청룡(동천)의 기가 드센 관계로 청룡의 흐름을 "S"자로 꺾어 흐르게 함으로써 기를 꺾을 수 있었으며, 몽촌토성은 해자의 복원으로 공원에 풍부한 수경 요소를 제공하는 경관요소로 활용하였다. 성을 둘러싸고 있는 해자는 자연이라는 진경 속에 선조들의 삶과 문화가 공간 속에 설득력 있게 배어든 역사와 문화적 경관이 표상이다. 4. 중국의 자금성 성벽은 찹쌀에 흙을 반죽하여 다져 넣어 매우 견고하며, 해자의 폭은 52m, 깊이는 6m로 자금성 성벽을 에워싸고 있어 적의 접근을 차단할 수 있었다. 5. 일본의 해자는 도시에 있어 수로 역할을 하였으며, 보트놀이, 배낚시, 레스토랑 등의 레저시설이 설치되어 도시민들의 스트레스를 해소하고 삶의 활력을 불어 넣을 수 있었다. 6. 한국의 해자는 중국의 자금성, 일본의 에도성, 오사카성보다 규모가 작으며 동양의 해자는 왕궁이나 읍성을 보호하기 위해 해자를 설치하였으나, 서양에서는 왕이나 영주, 대저택, 부호들의 저택 등을 보호하기 위해 해자를 설치하였다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF