• 제목/요약/키워드: Stress intensity

검색결과 2,000건 처리시간 0.029초

Major environmental factors and traits of invasive alien plants determining their spatial distribution

  • Oh, Minwoo;Heo, Yoonjeong;Lee, Eun Ju;Lee, Hyohyemi
    • Journal of Ecology and Environment
    • /
    • 제45권4호
    • /
    • pp.277-286
    • /
    • 2021
  • Background: As trade increases, the influx of various alien species and their spread to new regions are prevalent and no longer a special problem. Anthropogenic activities and climate changes have made the distribution of alien species out of their native range common. As a result, alien species can be easily found anywhere, and they have nothing but only a few differences in intensity. The prevalent distribution of alien species adversely affects the ecosystem, and a strategic management plan must be established to control them effectively. To this end, hot spots and cold spots were analyzed according to the degree of distribution of invasive alien plants, and major environmental factors related to hot spots were found. We analyzed the 10,287 distribution points of 126 species of alien plants collected through the national survey of alien species by the hierarchical model of species communities (HMSC) framework. Results: The explanatory and fourfold cross-validation predictive power of the model were 0.91 and 0.75 as AUC values, respectively. The hot spots of invasive plants were found in the Seoul metropolitan area, Daegu metropolitan city, Chungcheongbuk-do Province, southwest shore, and Jeju island. Generally, the hot spots were found where the higher maximum temperature of summer, precipitation of winter, and road density are observed, but temperature seasonality, annual temperature range, precipitation of the summer, and distance to river and sea were negatively related to the hot spots. According to the model, the functional traits accounted for 55% of the variance explained by the environmental factors. The species with higher specific leaf areas were more found where temperature seasonality was low. Taller species preferred the bigger annual temperature range. The heavier seed mass was only preferred when the max temperature of summer exceeded 29 ℃. Conclusions: In this study, hot spots were places where 2.1 times more alien plants were distributed on average than non-hot spots (33.5 vs 15.7 species). The hot spots of invasive plants were expected to appear in less stressful climate conditions, such as low fluctuation of temperature and precipitation. Also, the disturbance by anthropogenic factors or water flow had positive influences on the hot spots. These results were consistent with the previous reports about the ruderal or competitive strategies of invasive plants instead of the stress-tolerant strategy. The functional traits are closely related to the ecological strategies of plants by shaping the response of species to various environmental filters, and our result confirmed this. Therefore, in order to effectively control alien plants, it is judged that the occurrence of disturbed sites in which alien plants can grow in large quantities is minimized, and the river management of waterfronts is required.

베이지안 분류 기반 통합가뭄지수를 활용한 낙동강 유역의 미래 가뭄에 대한 수문학적 위험도 분석 (Evaluation of Future Hydrologic Risk of Drought in Nakdong River Basin Using Bayesian Classification-Based Composite Drought Index)

  • 김혁;김지은;김지영;유지영;김태웅
    • 대한토목학회논문집
    • /
    • 제43권3호
    • /
    • pp.309-319
    • /
    • 2023
  • 최근 기후변화로 인해 기상재해의 발생빈도와 강도가 증가하고 있다. 우리나라는 지역별 기후 특성의 편차로 인해 기후변화에 따른 취약성 및 대응능력이 지역별로 차이가 크다. 특히 가뭄은 다양한 요인에 의해 발생하고, 기상학적, 수문학적, 농업적 영향 범위가 광범위하다. 따라서 가뭄에 효과적으로 대응하기 위해서는 다양한 요인을 고려할 수 있는 통합가뭄지수를 활용할 필요가 있으며, 기후변화를 고려한 미래 가뭄을 종합적으로 평가해야 한다. 본 연구에서는 베이지안 분류(DNBC) 기반의 통합가뭄지수를 활용하여 낙동강 유역의 미래 가뭄에 대한 수문학적 위험도(${\bar{R}}$)를 평가하였다. 우선, 관측자료와 기후변화 시나리오 자료를 이용하여 부문별 가뭄지수(SPI, SDI, ESI, WSCI)를 DNBC에 적용하여 통합가뭄지수를 산정하였다. 산정된 통합가뭄지수의 심도와 지속기간을 대상으로 이변량 가뭄빈도분석을 실시하고, 이변량 재현기간을 활용하여 수문학적 위험도를 산정하였다. 그 결과, S2(2021-2040) 기간에서 위험도가 가장 높게 나타났으며(${\bar{R}}$=0.572), 평균적으로 위험도가 가장 높은 지역은 밀양강(#2021)이었다(${\bar{R}}$=0.94). 단기 미래(2021-2040) 기간 동안 낙동강 유역의 수문학적 위험도는 전반적으로 큰 폭으로 상승하였으며, 중·장기 미래(2041-2070, 2071-2099) 기간 동안 낙동강 유역 북부의 위험도는 감소하고 남부의 위험도는 상승하였다.

경험표집법을 통해 살펴본 도시노인의 일상생활 경험: 공간/대인맥락과 정서경험에서의 젠더차이를 중심으로 (Emotional Experience of Korean Urban Elderly in Everyday Lives using Experience Sampling Method: A focus on gender differences)

  • 한경혜;손정연
    • 한국노년학
    • /
    • 제29권3호
    • /
    • pp.1159-1182
    • /
    • 2009
  • 본 연구의 목적은 경험표집법을 이용하여 도시노인들의 일상생활 경험을 활동의 공간과 대인맥락을 중심으로 재구성하고, 이러한 일상의 맥락들이 노인들의 순간 정서경험과 어떠한 관련성을 맺고 있는지 탐색하는 것이다. 특히 노인의 일상생활의 구성과 그 과정에서 느끼는 정서적 경험은 노인이 처한 사회구조적 맥락에 의해 영향을 받는다는 점에 주목하여, 개인의 삶을 구성하는 중요한 맥락 중 하나인 젠더에 초점을 맞추어 수행되었다. 이를 위해 남성 76명, 여성 72명의 도시노인을 대상으로, 일상생활의 외적, 내적 경험을 동시에 파악할 수 있는 경험표집법을 사용하여 참여자들이 평소에 어디서, 누구와 함께 시간을 보내며, 매 순간마다 어떠한 긍정적, 부정적 정서를 경험하는지에 대한 정보를 수집하였다. 또한, 각 개인이 반복적으로 작성한 응답수를 분석의 단위로 하여 기술통계, 카이제곱검증, t 검증, 그리고 분산분석 및 Scheffe 사후검증을 실시하였다. 주요 분석결과는 다음과 같다. (1) 노인의 일상생활의 활동 공간 중 가장 높은 비중을 차지하는 공간은 집이고, 일상의 시간을 가장 많이 공유하는 사람은 배우자였다. (2) 전반적으로 여성이 남성보다 부정적 정서경험 수준이 높았다. (3) 활동의 공간 및 대인맥락과 정서경험 수준 간 관련성이 젠더에 따라 상이하였다. 이러한 주요 결과에 기초하여 노인의 일상생활에서의 정서경험의 의미와 이와 관련되는 일상의 맥락에서의 젠더차이를 논의하였다.

The Evaluation of Adaptability of Three Ever-green Perennial Herbaceous South Korea Native Plants under In-door Light Intensities

  • Sang Yeob Lee;Kyungtae Park;Bo Kook Jang;Cheol Hee Lee;Ju Sung Cho
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2020년도 춘계학술대회
    • /
    • pp.67-67
    • /
    • 2020
  • Though there is an on-going need for the diversity of ornamental plants for in-door environment, their growth and stress adaptability in comparatively low light intensity condition require further studies for implementation. Here investigates the growth and chlorophyll fluorescence parameters of Farfugium japonicum (L.) Kitam, Liriope muscari (Decne.) L.H.Bailey and Acorus gramineus Aiton under several light intensities which were based on common in-door environment. The growth measurement of the plants included the quantity, length, width and SPAD value of the leaves. Calculated values of Fm/Fo, Fv/Fm, Pi_Abs, ETo/RC and DIo/RC were used as the parameters of the chlorophyll fluorescence under 10, 50, 100 and 200 PPFD (μmol·m-2·s-1) light intensities. In-door plants group was put in a closed room allowing no other light sources for 10 weeks and the control group was put in glass-greenhouse for the same period. The overall in-door growth of L. muscari was not significantly different in all light intensities compared to the control group and even showed the higher SPAD values. Also, an increasing tendency of Pi_Abs value under 10 to 100 PPFD was observed implying that L.muscari could adapt well to in-door environment. Measurement of A. gramineus growth mostly showed the highest values in the control group especially in the number of the leaves. Nevertheless, chlorophyll fluorescence parameters showed no significant value difference between in-door and the control groups and thus, A. gramineus might have possibility of successful adaptation to in-door environment. F. japonicum showed deficient growth in plant height and leaf length compared to the control but, it seemed to be able to sustain ornamental value under in-door light intensities. Furthermore, Pi_Abs and DIo/RC values were increased under in-door light conditions suggesting potential adaptability of F. japonicum.

  • PDF

직립식 방파제 성능기반 내진 설계 Platform 개발을 위한 기초연구 - 전단파 횟수 누적에 따른 지반 강도 감소를 중심으로 (Preliminary Study on the Development of a Performance Based Design Platform of Vertical Breakwater against Seismic Activity - Centering on the Weakened Shear Modulus of Soil as Shear Waves Go On)

  • 최진규;조용준
    • 한국해안·해양공학회논문집
    • /
    • 제30권6호
    • /
    • pp.306-318
    • /
    • 2018
  • 지난 이십여 년 간 우리나라 연안에 집중적으로 거치된 직립식 방파제의 내진 성능을 검토하기 위한 예비 수치모의를 포항, 경주, Hachinohe1, Hachinohe2, Ofunato, 인공지진파를 대상으로 수행하였다. 예비 수치모의 결과 지진으로 인한 전단파가 지반을 통해 전파되는 과정에서 지진에너지가 장주기 대역으로 이동한 Hachinohe2의 경우 항 외곽시설의 활동량이 상당하다는 것을 확인하였다. 지진으로 인한 전단파는 항만시설이 거치된 지표방향으로 증폭되며, 지진에너지의 상당부분은 장주기 대역으로 이동된다. 이 중 장주기 대역으로 이동되는 현상은 지반의 점성 혹은 내부 마찰에 기인하며, 전단파 증폭은 구속 응력의 감소로 인해 지표면 방향으로 감소하는 전단계수와 내습하는 전단파 횟수 누적에 따른 지반 강도 감소에 기인하는 것으로 판단된다(Das, 1993). 이러한 인식에서 본고에서는 먼저 전단파 횟수 누적에 따른 전단계수의 감소의 기술이 가능한 Hardin과 Drnevich(1972) 모형과 파동방정식에 기초하여 수치모형을 구성하고, 이어 전단파 횟수 누적에 따른 전단계수의 감소가 전단파 전파과정에 미치는 영향을 정량적으로 평가하기 위한 수치모의를 수행하였다. 이 과정에서 비선형 응력-변형률 관계를 설명하기 위해 $Newmark-{\beta}$ 방법과 수정 Newton-Raphson 방법을 차용하였다(Chopra, 1995). 모의결과 전단파가 지표면으로 전파되면서 상당한 확률 질량이 상대적으로 큰 진폭과 장주기 쪽으로 이동하는 것을 확연하게 확인할 수 있었다.

STZ-당뇨쥐에서 운동부하가 골격근 및 간의 항산화효소 활성도에 미치는 영향 (Effect of Exercise on Antioxidant Enzyme Activities of Skeletal Muscle and Liver in STZ-diabetic Rats)

  • 석광호;이석강
    • Journal of Yeungnam Medical Science
    • /
    • 제17권1호
    • /
    • pp.21-30
    • /
    • 2000
  • 당뇨쥐에서 운동부하가 골격근과 간의 항산화효소 활성도에 미치는 영향과 산소유리기에 의한 조직손상 여부블 관찰한 연구 결과를 요약하면 다음과 같다. Strcptozotocin으로 유도한 당뇨군의 혈당농도(mg/dL)는 $344{\pm}14.8$로서 대조군의 $117{\pm}2.7$보다 높았으며(p<0.001) 운동부하에 의해서 유의하게 감소하였다(p<0.01). 혈장 인슐린 농도(${\mu}U/mL$)는 당뇨군에서 $8.5{\pm}0.5$로서 대조군의 $20.6{\pm}1.4$보다 유의하게 낮았으며(p<0.001) 운동부하후에는 운동부하전과 비교하여 차이가 없었다. 당뇨군에서 실제 운동부하의 정도를 평가하기 위해서 측정한 운동부하후 골격 끈파 간의 당원농도(mg/100 g wet wt.)는 각각 $1.0{\pm}0.1$$7.7{\pm}0.8$로서 운동부하전과 비교시 모두 유의하게 감소하였다(p<0.001, p<0.01). 당뇨군의 골격근과 간의 항산화효소 즉 superoxide dismutase(SOD), glutathionc pcroxidase(GPX) 및 catalase(CAT)의 활성도는 운동부하에 의해서 각기 다른 반응을 보였다. 골격근의 SOD 활성도(unit/mg protein)는 대조군에서 $6.3{\pm}0.2$였으며 당뇨군에서는 $5.8{\pm}0.2$로서 대조군과의 사이에 유의한 차이를 발견할 수 없었으나 운동부하후에는 $5.0{\pm}0.1$로서 대조군과 운동부하전 당뇨군보다 유의하게 감소하였다(p<0.001, p<0.01). GPX 활성도(nmol/min/mg protein)는 당뇨군에서 운동부하전후에 각각 $2.3{\pm}0.2$$1.8{\pm}0.1$로서 대조군의 $1.6{\pm}0.0$보다 다같이 높았으나(p<0.05, p<0.05) 운동부하에 의해서 영향을 받지 않았다. CAT 활성도(pmol/min/mg protein)는 당뇨군에서 $7.6{\pm}0.7$로서 대조군의 $6.3{\pm}0.7$과 비교하여 차이가 없었으나 훈동부하후에는 $4.6{\pm}0.3$으로서 대조군보다 감소하였으며(p<0.05) 당뇨군의 운동부하전보다도 감소하였다(p<0.01). 당뇨군의 MDA 농도는 대조군과 비교하여 차이가 없었으며 당뇨군에서 운동부하에 의한 영향도 받지 않았다. 간의 SOD 활성도는 대조군에서 $11.3{\pm}0.2$였으며 운동부하전 당뇨군에서는 $9.6{\pm}0.3$으로서 유의하게 감소하였다(p<0.01). 당뇨군에서 운동부하전후 측정한 SOD 활성모는 대조군과 비교하여 다같이 감소하였으나(p<0.01, p<0.001), 운동부하에 의한 영향은 없었다. 당뇨군외 GPX와 CAT의 활성도는 대조군과 비교하여 유의한 차이가 없었으며 당뇨군에서 운동 부하에 의한 변화도 없었다. 운동부하전 당뇨군의 MDA 농도(nmol/g wet wt.)는 $38.5{\pm}1.3$으로서 대조군의 $24.8{\pm}0.9$에 비해서 유의하게 증가하였으며(p<0.001) 운동부하에 의해서는 대조군보다는 높았으나(p<0.001) 운동부하전과 비교하여서는 차이가 없었다. 이상의 결과를 종합하면 당뇨쥐에서 골격근은 운동부하로 인한 산화 스트레스에 대한 적응과정을 통해서 손상이 없었으나, 간 조직은 당뇨병 자체로 인한 산소유리기의 발생으로 손상의 위험이 있었으나 운동부하에 의한 더 이상의 손상은 없었다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

소아기 외상 : 발달경로에 따른 보호 및 위험인자 (CHILDHOOD TRAUMA:RESILIENCE AND RISK FACTORS ON DEVELOPMENTAL TRAJECTORY)

  • 김영신
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • 제13권1호
    • /
    • pp.15-23
    • /
    • 2002
  • 소아기 외상이 아동의 발달에 미치는 부정적인 결과를 예방하는 resilience factor와 부정적인 결과를 더욱 증폭시키는 위험인자에 대한 지식은 이 분야의 전향적인 연구의 부재와 소아기 외상과 발달과정, 아동의 환경 등 다양한 측면들의 유기적인 관계에 대한 이해의 어려움으로 아직은 초보적인 단계이다. 이러한 소아기 외상의 연구에서의 개념적, 연구 방법론적인 어려움은 현재까지 발표된 연구들의 결과가 일관적이지 못하고 때로는 상반적이기도 한 면으로 나타나기도 한다. 이러한 어려움에도 불구하고 지금까지 발표된 연구들을 종합하여 보면 몇 가지 중요한 공통적인 결론을 도출할 수가 있다. 즉 사춘기 전에는 여아가, 사춘기 후나 영아에서는 남아가, 사회경제적 지위가 높은 가정의 아동, 기질적인 문제가 없는 경우, 쉬운 기질, 조기 이별이나 상실의 경험이 없는 경우, 외상을 받은 시기가 어릴수록, 문제 해결능력이 좋은 경우, 높은 자존감, internal locus of control, 우수한 대처 능력, 대인 관계를 인지 할 수 있는 능력, 놀이를 할 수 있는 능력, 유머 감각이 있는 경우, 유능한 부모를 가지고 있거나 혹은 적어도 한명의 보호자와 따뜻한 관계를 맺고 있을 때, 교육 정도가 높거나 조직적인 종교 활동에 참여 하고 있는 아동들은 외상을 경험하였을 때 외상의 부정적인 결과에 대하여 resilient하게 된다. 이러한 결과는 아동기 외상의 위험 및 보호인자가 서로 독립되어 있기 보다는 상호작용을 하는 유기적인 관계이며, 각 요소가 아동의 발달 단계, 아동 자신 및 그들의 가족과 환경에 따라 다양하게 작용하고, stressor의 영향은 그 강도에 따라 다양한 작용을 보이며 일부 위험요소와 보호요소는 상대방의 효과를 상승시키거나 감소시키는 등 복잡한 상호 관계를 보이는 것을 시사한다. 앞으로 소아기 외상과 발달 정신병리와의 관계, 위험 및 보호인자에 대한 포괄적인 이해 및 이를 바탕으로 효과적이며 효율적인 예방 및 치료적인 개입이 가능해지기 위해서는 stress가 정상적인 신경발달에 미치는 영향, 유전적인 소인과 부모의 요인과 같은 개개인의 소인에 대한 차이점, 신경조절의 resilience 연구, 소아기 외상의 예방과 뇌의 plasticity에 관한 연구가 같이 진행되어야 할 것이다.

  • PDF

이산화티탄과 UV-B 수준에 따른 벼 생육과 프로테옴 해석 (Proteomic Analysis and Growth Responses of Rice with Different Levels of Titanium Dioxide and UV-B)

  • 홍성창;신평균;장안철;이기상;이철원;우선희
    • 한국작물학회지
    • /
    • 제52권1호
    • /
    • pp.69-80
    • /
    • 2007
  • 태양광과 반응하여 독특한 광화학적 작용을 하는 이산화티탄($TiO_2$)을 벼 잎 표면에 처리하였을 때 벼 엽신의 광합성 대사에 대한 영향을 검토하고 프로테옴 분석을 통해 생리변화를 구명하고자 수행한 결과를 요약하면 다음과 같다. 1. 광합성유효파장이 $2,400\;{\mu}mol\;m^{-2}\;s^{-1}$$2,200\;{\mu}mol\;m^{-2}\;s^{-1}$ 배치구에서 이산화티탄 10, 20 ppm 처리는 광적응상태의 엽록소형광지수(Yield)를 낮추었고 $450\;{\mu}mol\;m^{-2}\;s^{-1}$ 처리구는 엽록소형광지수를 높였다. 2. 노지조건인 PAR $2,400\;{\mu}mol\;m^{-2}\;s^{-1}$ 배치구에서 광합성 명반응의 상대전자전달율은 이산화티탄 10 ppm 처리에서 평균 45 %, 무처리 32.4 %, diuron 10 ppm 처리구에서 15.3%로 이산화티탄 처리는 광합성 명반응의 상대전자전달율을 높였다. 3. UV-B 4.9, $0.6\;KJ\;m^{-2}\;day^{-1}$ 배치구에서 이산화티탄 처리로 초장이 증가하였고 UV-B $0.15\;KJ\;m^{-2}\;day^{-1}$ 배치구에서 초장은 증가하고 건물중은 감소하였다. 4. 광합성은 노지의 UV-B 조건인 $13.6\;KJ\;m^{-2}\;day^{-1}$ 배치구에서 이산화티탄 처리로 종가하였고 UV-B 4.9, 0.6, $0.15\;KJ\;m^{-2}\;day^{-1}$ 배치구는 다소 증가하였으나 통계적으로 유의한 차이는 나타내지 않았다. 5. 이산화티탄 처리 후 자연광 중의 UV-B를 99% 차단하여 저수준으로 조절한 결과 68%의 단백질 발현이 감소하였고 각각 16%의 단백질 발현이 증가 또는 신생 합성되었다. 6. 이산화티탄 20 ppm 처리 후 자연광 중의 UV-B를 99% 차단시켰을 때 주로 광합성 Calvin cycle에서 $CO_2$ 결합을 촉매하는 결정구조 Rubisco의 chain E 발현이 감소하였다.