• 제목/요약/키워드: Stress Detection

검색결과 387건 처리시간 0.03초

Application of Fuzzy Theory and Analytic Hierarchy Process(AHP) for Developing Occupational Stress Index

  • Jung, Hwa Shik
    • 대한인간공학회지
    • /
    • 제17권2호
    • /
    • pp.33-48
    • /
    • 1998
  • This paper illustrates the application of Fuzzy Theory and Analytic Hierarchy Process(AHP) for developing Occupational Stress Index(OSI). The purpose of the OSI development is for future prediction and problem solving of prevailing occupational stress. In developing OSI, the concept of fuzzy set theory was introduced to determine the existence and level of perceived occupational stress instead of actually measuring the strain parameters. The AHP is adopted to collect different weighting factors, since there exist various perceptions and responses to the occupational stress by different individuals. The validation study revealed that the OSI is a reliable predictor of work-related accident and illness and the physiological health of employees. Creating preventive measures, such as early detection of stress, proper placement and promotion of employees, and job enlargement will be possible by using this OSI effectively.

  • PDF

음탄성법을 이용한 고장력 볼트의 축응력 평가 (Estimation of the Axial Stress in High-Tension Bolt by Acoustoelastic Method)

  • 전해화;이태훈;장경영;김노유
    • 비파괴검사학회지
    • /
    • 제26권5호
    • /
    • pp.285-290
    • /
    • 2006
  • 고장력볼트의 체결상태를 평가하는 것은 체결볼트의 안전유지관리 측면에서 매우 중요하다. 본 논문에서는 초음파의 음속이 응력에 의존하는 이른바 음탄성효과에 기초하여 초음파의 전파시간(TOF)를 측정함으로써 볼트에 작용하는 축응력을 평가하는 방법을 제안한다. 그런데 일반적으로 볼트체결시 볼트에 작용하는 응력범위내에서의 음속 변화량은 매우 작으며, 따라서 TOF 측정에 있어서 높은 정밀도가 요구된다. 이를 위해 본 논문에서는 톤버스트파형의 초음파를 이용한 위상검출법을 적용하였다. 제안된 원리는 실험을 통해 검증되었으며, 볼트 축응력 측정의 유효성을 검증하기 위해 스트레인게이지를 이용한 축응력 측정결과와 비교하였다. 두 결과는 양호한 일치를 보였으며, 이로써 제안한 방법이 체결된 고장력볼트의 체결상태 평가에 유용하다는 결론을 얻을 수 있었다.

광섬유 센서를 이용한 복합재 구조물의 실시간 파손감지 (Real-time Failure Detection of Composite Structures Using Optical Fiber Sensors)

  • 방형준;강현규;류치영;김대현;강동훈;홍창선;김천곤
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 추계학술발표대회 논문집
    • /
    • pp.128-133
    • /
    • 2000
  • The objective of this research is to develop real-time failure detection techniques for damage assessment of composite materials using optical fiber sensors. Signals from matrix cracking or fiber fracture in composite laminates are treated by signal processing unit in real-time. This paper describes the implementation of time-frequency analysis such as the Short Time Fourier Transform(STFT) to determine the time of occurrence of failure. In order to verify the performance of the optical fiber sensor for stress wave detection, we performed pencil break test with EFPI sensor and compared it with that of PZT. The EFPI sensor was embedded in composite beam to sense the failure signals and a tensile test was performed. The signals of the fiber optic sensor when damage occurred were characterized using STFT and wavelet transform. Failure detection system detected the moment of failure accurately and showed good sensitivity with the infinitesimal failure signal.

  • PDF

Colorimetric Effect of Au Nanoparticle Chain/Polymer Film under Mechanical Stress and Gas Pressure

  • Shim, Gowoon;Eom, Kiryung;Lee, Gyuyeon;Seo, Hyungtak
    • 한국재료학회지
    • /
    • 제28권1호
    • /
    • pp.1-5
    • /
    • 2018
  • Gas detection is necessary for various reasons, including the prevention of gas leakages and the creation of necessary environmental conditions. Among the gas detection methods, leakage of gas can be confirmed using materials that undergo color changes that are easily distinguished by the naked eye. Metal nanoparticles (NPs) experience variations in their absorption wavelengths under the localized surface plasmon effect (LSPR) with mechanical stresses, which change the distance between NPs. In this study, we attempted to detect the presence of gas utilizing the LSPR-related color change of a chain of Au NPs. The assembly of Au NPs, arranged in a chain shape, experienced a color change from dark blue to purple with a change in the distance between the NPs by applying a physical force, i.e., compression, stretching, and gas pressure. As the force of compression and the degree of stretching increased, the absorption wavelength shifted from doublet peaks at 650 and 550 nm to a singlet peak at 550 nm. Further, applying gas pressure caused an identical color change. With this result, we propose a method that could be applied to all gases that require detection based on gas pressure.

Fabrication of low-stress silicon nitride film for application to biochemical sensor array

  • 손영수
    • 센서학회지
    • /
    • 제14권5호
    • /
    • pp.357-361
    • /
    • 2005
  • Low-stress silicon nitride (LSN) thin films with embedded metal line have been developed as free standing structures to keep microspheres in proper locations and localized heat source for application to a chip-based sensor array for the simultaneous and near-real-time detection of multiple analytes in solution. The LSN film has been utilized as a structural material as well as a hard mask layer for wet anisotropic etching of silicon. The LSN was deposited by LPCVD (Low Pressure Chemical Vapor Deposition) process by varing the ratio of source gas flows. The residual stress of the LSN film was measured by laser curvature method. The residual stress of the LSN film is 6 times lower than that of the stoichiometric silicon nitride film. The test results showed that not only the LSN film but also the stack of LSN layers with embedded metal line could stand without notable deflection.

Investigations on PD Characteristics of Thermal aged Palm and Corn Oil for Power Transformer Insulation Applications

  • Senthilkumar, S.;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1660-1669
    • /
    • 2014
  • Partial discharge (PD) detection plays a major role in the life time assessment of liquid insulation in power transformers. Many research works are being carried out to replace conventional mineral oil insulation in transformers by vegetable oils. It is necessary to understand the PD characteristics of vegetable oils before recommending them as an alternate for mineral oil. In this paper, the breakdown strength and PD characteristics of palm and corn oil were investigated in both unaged and thermally aged conditions. Laboratory experiments were performed as per IEC test procedures. PD signals were measured using wide band detection system. Phase resolved PD pattern of vegetable oils and mineral oil were compared. Effect of increase in voltage stress on the PD pattern of palm and corn oil were studied. Time and frequency domain analysis of PD pulses at needle-plane electrode configuration was carried out. Statistical analysis of PD pattern i.e. skewness and shape parameter variations with respect to applied thermal stress were also carried out. From the results, it is observed that palm and corn oils have better breakdown strength and PD characteristics even under long-term thermal stress and hence they can be used for power transformer applications.

토마토 잎의 비파괴 계측에 의한 N, P, Ca 결핍 장해 진단법 비교 (Comparison of Non-destructive Measuring Methods of Tomato Plant to Detect N, P and Ca Deficient Stresses)

  • 서상룡;류육성;정갑채;성제훈;이성희
    • Journal of Biosystems Engineering
    • /
    • 제25권6호
    • /
    • pp.517-526
    • /
    • 2000
  • A series of experiments was conducted to evaluate the capability of detecting nutrimental deficient stress of N, P and Ca of a tomato plant using several fast and intact type physiological properties measuring devices - a chlorophyll content meter an infra-red thermometer to measure leaf temperature a chlorophyll fluorescence meter a porometer an optical spectrometer a multi-scan radiometer and a canopy analyzer. to detect N deficient stress a chlorophyll content meter a spectrometer and a multi-scan radiometer were useful and their possibility to detect was estimated as about 50%, 100% and 100% respectively. To detect P deficient stress the infra-red thermometer the porometer and the spectrometer proved their usefulness an their possibility to detect was estimated as about 70%, 70% and 70% respectively. To detect Ca deficient stress an thermometer a porometer a spectrometer and a multi-scan radiometer were useful and their possibility to detect was estimated as about 60%, 70%,80% and 100% respectively. The experiments resulted that use of a spectrometer and a multi-scan radiometer in combination with a chlorophyll content meter an infra-red thermometer and a porometer were desirable to distinguish the nutrimental stress tested in the study.

  • PDF

Effects of heat stress on body temperature, milk production, and reproduction in dairy cows: a novel idea for monitoring and evaluation of heat stress - A review

  • Liu, Jiangjing;Li, Lanqi;Chen, Xiaoli;Lu, Yongqiang;Wang, Dong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제32권9호
    • /
    • pp.1332-1339
    • /
    • 2019
  • Heat stress exerts a substantial effect on dairy production. The temperature and humidity index (THI) is widely used to assess heat stress in dairy operations. Herein, we review the effects of high temperature and humidity on body temperature, feed intake, milk production, follicle development, estrous behavior, and pregnancy in dairy cows. Analyses of the effects of THI on dairy production have shown that body temperature is an important physiological parameter in the evaluation of the health state of dairy cows. Although THI is an important environmental index and can help to infer the degree of heat stress, it does not reflect the physiological changes experienced by dairy cows undergoing heat stress. However, the simultaneous measurement of THI and physiological indexes (e.g., body temperature) would be very useful for improving dairy production. The successful development of automatic detection techniques makes it possible to combine THI with other physiological indexes (i.e., body temperature and activity), which could help us to comprehensively evaluate heat stress in dairy cows and provide important technical support to effectively prevent heat stress.

LC/MS/MS를 이용한 산화성 스트레스 지표로써 소변 중 8-iso-PGF 분석 (Determination of 8-iso-PGF as Oxidative Stress Marker in Human Urine by High Performance Liquid Chromatography with Tandem Mass Spectrometry)

  • 고영림;이은희;채홍재;최경호;백도명
    • 한국환경보건학회지
    • /
    • 제36권1호
    • /
    • pp.44-51
    • /
    • 2010
  • This study aimed to develop analytical method for 8-isoprostanes as biomarkers for oxidative stress with LC/MS/MS technique and to apply the method for human urine samples. Analyzed compounds for urinary oxidative stress markers were 7 stereo-isomers of prostaglandins and the internal standard (iso-$PGF_{2{\alpha}}-d_4$) was used to adjust the recovery rate. The method for determining urinary iso-$PGF_{2{\alpha}}$ consisted of solid phase extraction and LC/MS/MS detection. Separation of isomers of prostaglandins completed by porous graphitic carbon column and buffer solution. Detection limits for urinary markers of oxidative stress, iso-$PGF_{2{\alpha}}$ with LC/MS/MS were 0.01 ng/ml by S/N ratio 3 and 0.028 ng/ml by calculated as to FDA method. The recovery (92.8~101.9%) and precision (8.8~20.7%) of analysis were feasible for detecting iso-$PGF_{2{\alpha}}$ in real human urine samples. We detected 4 isomers of prostaglandins in human urine samples. Mean (standard deviation) of urinary iso-$PGF_{2{\alpha}}$ concentration were 0.231 (0.117) ng/mg creatinine for smoking group and 0.154 (0.082) ng/mg creatinine for non-smoking group.

New Protein Extraction/Solubilization Protocol for Gel-based Proteomics of Rat (Female) Whole Brain and Brain Regions

  • Hirano, Misato;Rakwal, Randeep;Shibato, Junko;Agrawal, Ganesh Kumar;Jwa, Nam-Soo;Iwahashi, Hitoshi;Masuo, Yoshinori
    • Molecules and Cells
    • /
    • 제22권1호
    • /
    • pp.119-125
    • /
    • 2006
  • The rat is an accepted model for studying human psychiatric/neurological disorders. We provide a protocol for total soluble protein extraction using trichloroacetic acid/acetone (TCA/A) from rat (female) whole brain, 10 brain regions and the pituitary gland, and show that two-dimensional gel electrophoresis (2-DGE) using precast immobilized pH (4-7) gradient (IPG) strip gels (13 cm) in the first dimension yields clean silver nitrate stained protein profiles. Though TCA/A precipitation may not be "ideal", the important choice here is the selection of an appropriate lysis buffer (LB) for solubilizing precipitated proteins. Our results reveal enrichment of protein spots by use of individual brain regions rather than whole brain, as well as the presence of differentially expressed spots in their proteomes. Thus individual brain regions provide improved protein coverage and are better suited for differential protein detection. Moreover, using a phosphoprotein-specific dye, ingel detection of phosphoproteins was demonstrated. Representative high-resolution silver nitrate stained proteome profiles of rat whole brain total soluble protein are presented. Shortcomings apart (failure to separate membrane proteins), gel-based proteomics remains a viable option, and 2-DGE is the method of choice for generating high-resolution proteome maps of rat brain and brain regions.