• 제목/요약/키워드: Stress Corrosion

검색결과 906건 처리시간 0.028초

표면처리법에 따른 $SUP-9/50CrV_{4}$의 부식특성에 관한 연구 (A Study on Corrosion Characteristics of $SUP-9/50CrV_{4}$by Surface Processing)

  • 정재욱;박경동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.319-324
    • /
    • 2004
  • In this study, the high strength and superior toughness spring steels as the suspension material, used for automobile and railroad industries were utilized to carry out the following investigations. Corrosion times were controlled in 7, 14, 30 and 60days to examine the relation between corrosion pit and compressive residual stress in the static corrosion environment after shot peened. And then corrosion current and corrosion potential were measured for every 24 hours to investigate the corrosion mechanism. Shot peened material shows the low or rate of corrosion current as compared with unpeened material. In case of peened material which has the highest residual stress, it has a low corrosion current density.

  • PDF

연강의 전기화학적인 응력부식에 관한 연구 (I) (ELECTRO-CHEMICAL ASPECTS OF STRESS CORROSION OF MILD STEELS ( I ))

  • 김석호
    • 한국수산과학회지
    • /
    • 제7권4호
    • /
    • pp.234-237
    • /
    • 1974
  • $5\%\;H_2SO_4$ 수용액에 연강재를 침적하여 두고 전압 100mV, 전류 100mA 하에 응력을 부가시킨 상태로 전기화학적인 부식을 시켜 부식으로 인한 질양손실 및 인장응력을 측정해 본 결과 다음과 같은 결과를 얻었다. 1. 부식된 질양척실은 부식시 부가응력이 높을 수록 커지며, 처음부터 천천히 부식질양이 점차 증가하여 어느 일정한 시간(본 실험에는 약 13시간)이 경과한 후에 서로 비례 관계가 성립함을 볼 수 있었다 . 2. 부가응력과 부식으로 인한 응력감소율은 서로 역비례 관계가 성립하며, 항복응력의 감소율과 인장응력의 감소율은 거의 일치하였다. 3. 재료외 불순물이 밀집한 부분이나 결정립계가 부식되어 점차 확대되었다. 4. 외력에 의한 내력(응력)이 산재하거나 가공경화로 사한 공간격자의 변화가 있는 불안전한 조직을 가진 재료는 부식의 응력감소율이 적었다.

  • PDF

산성안개하에서 기계·구조용강의 응력부식균열 거동 (Behavior of Stress Corrosion Cracking in Structural Steel under Acid Fog Environment)

  • 임용호;김민건
    • 산업기술연구
    • /
    • 제17권
    • /
    • pp.291-295
    • /
    • 1997
  • The tests of stress corrosion cracking in structural carbon steel were carried out under the conditions of acid fog and general water. As the result of measurement SCC rupture time under acid fog was observed to be much shorter than that of general water at the same stress level. Therefore, acid fog drops the SCC strength in structural carbon steel due to strong corrosion. In the SCC process by acid fog, crack initiation was caused by pit corrosion and local stress concentration, and distinctive feature of crack growth shows branching since crack grows to the corrosion direction. Moreover, corrosion products were observed by clevage corrosion on the crack surfaces.

  • PDF

Corrosion Fatigue Characteristics in the Weld of Multi-Pass Welded A106 Gr B Steel Pipe

  • Bae, Dong-Ho;Kim, Chul-Han
    • Journal of Mechanical Science and Technology
    • /
    • 제18권1호
    • /
    • pp.114-121
    • /
    • 2004
  • In order to investigate the corrosion fatigue characteristics in the weld of multi-pass welded A 106 Gr B steel pipe, corrosion fatigue tests were performed under the various stress ratios and 3.5 wt% NaCl solution at room temperature. The corrosion fatigue characteristic curves were represented using crack closure concept. The obtained results are as follows : when the load frequency is 1.0 Hz, the crack opening point is transited in the region of $K_{max}$=20∼32 MPaㆍ $m^{1}$2/. In the low stress intensity factor range, the crack opening point is higher than that in air. However, in the high stress intensity factor range, it is lower than that in air. In the cases of 0.1 Hz and 0.01 Hz, the crack opening point gradually decreases to $K_{min}$ with $K_{max}$ increase.rease.

PbSCC of Ni-base Alloys in PbO-added Pure Water

  • Kim, Joung Soo;Yi, Yong-Sun;Kwon, Oh Chul;Kim, Hong Pyo
    • Corrosion Science and Technology
    • /
    • 제6권6호
    • /
    • pp.316-321
    • /
    • 2007
  • The effect of annealing on the pitting corrosion resistance of anodized Al-Mg alloy (AA5052) processed by equal-channel angular pressing (ECAP) was investigated by electrochemical techniques in a solution containing 0.2 mol/L of $AlCl_3$ and also by surface analysis. The Al-Mg alloy was annealed at a fixed temperature between 473 and 573 K for 120 min in air after ECAP. Anodizing was conducted for 40 min at $100-400A/m^2$ at 293 K in a solution containing 1.53 mol/L of $H_2SO_4$ and 0.0185 mol/L of $Al_2(SO_4)_3$. The internal stress generated in anodic oxide films during anodization was measured with a strain gauge to clarify the effect of ECAP on the pitting corrosion resistance of anodized Al-Mg alloy. The time required to initiate the pitting corrosion of anodized Al-Mg alloy was shorter in samples subjected to ECAP, indicating that ECAP decreased the pitting corrosion resistance. However, the pitting corrosion resistance was greatly improved by annealing after ECAP. The time required to initiate pitting corrosion increased with increasing annealing temperature. The strain gauge attached to Al-Mg alloy revealed that the internal stress present in the anodic oxide films was compressive stress, and that the stress was larger with ECAP than without. The compressive internal stress gradually decreased with increasing annealing temperature. Scanning electron microscopy showed that cracks occurred in the anodic oxide film on Al-Mg alloy during initial corrosion and that the cracks were larger with ECAP than without. The ECAP process of severe plastic deformation produces large internal stresses in the Al-Mg alloy; the stresses remain in the anodic oxide films, increasingthe likelihood of cracks. It is assumed that the pitting corrosion is promoted by these cracks as a result of the higher internal stress resulting from ECAP. The improvement in the pitting corrosion resistance of anodized AlMg alloy as a result of annealing appears to be attributable to a decrease in the internal stresses in anodic oxide films

Effect of Additives on the Stress Corrosion Cracking Behavior of Alloy 600 in High Temperature Caustic Solutions

  • Hur, Do Haeng;Kim, Joung Soo;Baek, Jae Sun;Kim, Jung Gu
    • Corrosion Science and Technology
    • /
    • 제3권1호
    • /
    • pp.6-13
    • /
    • 2004
  • The effect of inhibitors on the electrochemical behavior and the stress corrosion cracking resistance of Alloy 600(UNS N06600) was evaluated in 10% sodium hydroxide solution at $315^{\circ}C$. The specimens of a C-ring type for stress corrosion cracking test were polarized at 150 mV above the corrosion potential for 120 hours with and without inhibitors such as titanium oxide, titanium boride and cerium boride. The chemical compositions of the films formed on the crack tip in the C-ring specimens were analyzed using a scanning Auger electron spectroscopy. The cerium boride, the most effective, was observed to decrease the crack propagation rate more than a factor of three compared with that obtained in no inhibitor solution. It was found that the changes of the active-passive transition potentials and the film compositions were related to the resistance to stress corrosion cracking in high temperature caustic solution.

차량용 스프링강재의 압축잔류응력이 부식에 미치는 영향 (The Effect of Compressive Residual Stress of Spring Steel for Vehicle on Corrosion)

  • 박경동;안재필
    • 한국자동차공학회논문집
    • /
    • 제13권1호
    • /
    • pp.159-165
    • /
    • 2005
  • Shot peening can be defined as the process of work hardening of the surface of components by means of propelled stream of spherical shot. Benefits due to shot peening are increase in resistance to fatigue, stress corrosion cracking, fretting, galling, erosion and closing of pores. In this study, the influence of shot peening on the corrosion was investigated on spring steel immersed in $3.5\%\;NaCl$. The immersion test was performed on the two kinds of specimens. Corrosion potential, polarization curve, residual stress and etc. were investigated from experimental results. From test results, the effect of shot peening on the corrosion was evaluated. The important results of the experimental study on the effects of shot peened spring steels on the environment corrosion are as follows; In case of corrosion potential, shot peened specimen shows more activated negative direction as compared with parent metal. Surface of specimen, which is treated with the shot peened, is placed as more activated state against inner base metal. It can cause the anti-corrosion effect on the base metal.

EFFECT OF COMPRESSIVE RESIDUAL STRESS FOR CORROSION PROPERTY OF SUP-9 STEEL USING AS SUSPENSION MATERIAL

  • Park, K.D.;Ki, W.T.;Shin, Y.J.;Ryu, H.J.
    • International Journal of Automotive Technology
    • /
    • 제8권3호
    • /
    • pp.343-349
    • /
    • 2007
  • One of the useful technologies for light-weightening of components required in the automobile and machine industry is to use high strength materials. To improve material properties, the carbonizing treatment, nitrifying treatment, and shot-peening method are representatively applied. However, the shot-peening method is generally used to remove surface defect on steel and to improve the fatigue strength of the surface. Benefits of shot-peening are increasing resistance against fatigue, stress corrosion cracking, fretting, galling, erosion and closing of pores. In this paper, the effect of shot-peening on the corrosion of SUP-9 steel immersed in a 3.5% NaCl solution and corrosion characteristics from heat treatment during the shot peening process has been investigated. The immersion test was performed on four kinds of specimens. Corrosion potential, the polarization curve, residual stress etc. Were analyzed from the experimental results.

Stress corrosion index of Kumamoto andesite estimated from two types of testing method

  • Jeong Hae-Sik;Nara Yoshitaka;Obara Yuzo;Kaneko Katsuhiko
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.221-228
    • /
    • 2003
  • The stress corrosion index of Kumamoto andesite are evaluated by two types of testing method. One is the uniaxial compression test under various water vapor pressures, and the other is the double torsion (DT) test under a constant water vapor pressure. For the uniaxial compression tests, the uniaxial compressive strength increases linearly with decreasing water vapor pressure on the double logarithmic coordinates. As the results, the stress corrosion index obtained is estimated 44. On the other hand, in the DT test, the relaxation (RLX) test and the constant displacement rate (CDR) test were conducted. For the CDR test, as the displacement rate of loading point increases, the crack velocity increases. However, the fracture toughness is constant regardless of the change in displacement rate and the average fracture toughness is evaluated $2.07MN/m^{3/2}$. For the RLX test, the crack velocity-stress intensity factor curves are smooth and linear. The stress corrosion index estimated from the curves is 37. Comparing stress corrosion indexes in the uniaxial compression test and the DT test, there is no significant difference in these values, and they are considered to be in coincident each other regardless of testing methods. Therefore, it is concluded that stress corrosion is one of material constants of rock.

  • PDF

압축잔류응력을 부여한 스프링강의 부식피로 수명평가 (An Evaluation on Corrosion Fatigue life of Spring Steel by Compressive Residual Stress)

  • 박경동;기우태;신영진
    • 한국자동차공학회논문집
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 2007
  • In this study, the influence of compressive residual stress and corrosive condition for corrosion fatigue crack was investigated, after immersing in 3.5%NaCl, $10%HNO_3+3%HF,\;6%FeCl_3$. The immersion period was performed for 90days. The fatigue characterization of a spring steel with processed shot peening were performed by considering the several corrosion environments in the range of stress ratio of 0.05 by means of opening mode displacement. By using the methods mentioned above, the following conclusions have been drawn: The fatigue life shows more improvement in the shot peened material than that in the un peened material. And the fatigue life shows improvement in ambient than in corrosion conditions. Threshold stress intensity factor range of the shot peened materials has higher than of the un peened materials. And the threshold stress intensity factor range was decreased in corrosion environments over ambient.