• 제목/요약/키워드: Stress%0D%0A

검색결과 1,025건 처리시간 0.036초

Hematological Characteristics of the Cultured Eel, Anguilla japonica by Vibration Stress

  • Kim, Dae-Hee;Nam, Myung-Mo;Lee, Si-Woo;Kang, Kyoung Ho;Kang, Yue Jai;Hur, Jun Wook
    • 한국해양생명과학회지
    • /
    • 제3권2호
    • /
    • pp.81-86
    • /
    • 2018
  • The purpose of this study is to determine the effects of vibration on primary (e.g. plasma cortisol), secondary (e.g. plasma glucose, aspartate aminotransferase (AST), alanine aminotransferase (ALT), Na+, K+ and Cl- and tertiary (e.g. mortality) stress responses in cultured eel, Anguilla japonica. For this purpose, three groups (including one control group and two stress groups) were set up. The control group was made exposed to vibration corresponding to 48 decibel (dB, V) (produced using electric vibrators) for 15 minutes per hour every day, and the two stress groups was made exposed to vibration corresponding to 58 and 68 dB (V) (produced using the same electric vibrators), equally, for 15 minutes per hour every day. Blood was sampled at day 0 (before starting vibration stress tests, BS), and days 1, 3, 5, 7, 9 and 11 (after starting vibration stress tests). As a result, plasma cortisol showed trend to continuously rise by consecutive stress from 4.1±0.1 ng/ml in BS. In 48 dB group (control), cortisol showed the highest level with 7.6±0.9 ng/ml after 7 days (p<0.05), but at 9 and 11 days was not significantly compared with BS level. In 58 dB group, the cortisol showed the highest level with 43.1±4.8 ng/ml after 1st day. Cortisol of 68 dB group increased significantly during the experimental period (14.4±2.3~32.0±5.7 ng/ml) (p<0.05). In 58, and 68 dB groups during the experimental period differed significantly compared to 48 group (p<0.05). Glucose in 48 dB were increased from 42.0 ±5.7 (BS) to 52.5±2.1 (1 day), the level was not significantly from 1 to 11 days. Glucose in 58 and 68 dB groups was increased significantly than BS during experimental period (p<0.05). K+ in 68 dB increased significantly (p<0.05) from 2.3±0.2 mE/ql (BS) to 3.3±0.5 mE/ql at 5 days. In 48 and 58 dB groups during the experimental period differed significantly (p<0.05). Na+ and Cl- levels were not differed significantly during the experimental period. AST and ALT in 58 and 68 dB groups showed trend to continuously rise by consecutive stress. At 7 and 9 days in AST, between 48, 58 and 68 dB groups differed significantly (p<0.05). In 48, 58 and 68 dB groups at 1 day, blood hematocrit increased significantly higher than BS. The 11 days after vibration stress, the mortality in 48, 58 and 68 dB groups was 1.1, 5.1 and 5.8%, respectively. The present results have shown that A. japonica exhibited ''typical'' physiological responses when exposed to chronic vibration stress. These data suggested that chronic vibration stress caused substantial stress in the fish; especially the persisting elevated plasma AST and ALT levels observed would be expected to adverse effect. In conclusion, chronic vibration stress could greatly affects the hematological characteristics in A. japonica.

상이한 골질과 제원에 따른 짧은 임프란트의 응력 분포: 3차원 유한 요소 분석 (STRESS DISTRIBUTION PATTERN OF THE DIFFERENT DIAMETER AND LENGTH OF SHORT IMPLANTS ACCORDING TO THE BONE QUALITY : 3-D FINITE ELEMENTS ANALYSIS)

  • 김한구;김창현;표성운
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.116-126
    • /
    • 2009
  • The use of short implants has been accepted risky from biomechanical point of view. However, short implants appear to be a long term viable solution according to recent clinical reports. The purpose of this study was to investigate the effect of different diameter and length of implant size to the different type of bone on the load distribution pattern. Stress analysis was performed using 3-dimensional finite element analysis(3D-FEA). A three-dimensional linear elastic model was generated. All implants modeled were of the various diameter(${\phi}4.0$, 4.5, 5.0 and 6.0 mm) and varied in length, at 7.0, 8.5 and 10.0 mm. Each implant was modeled with a titanium abutment screw and abutment. The implants were seated in a supporting D2 and D4 bone structure consisting of cortical and cancellous bone. An amount of 100 N occlusal load of vertical and $30^{\circ}$ angle to axis of implant and to buccolingual plane were applied. As a result, the maximum equivalent stress of D2 and D4 bones has been concentrated upper region of cortical bone. As the width of implant is increased, the equivalent stress is decreased in cancellous bone and stress was more homogeneously distributed along the implants in all types of bone. The short implant of diameter 5.0mm, 6.0mm showed effective stress distribution in D2 and D4 bone. The oblique force of 100N generated more concentrated stress on the D2 cortical bone. Within the limitations of this study, the use of short implant may offer a predictable treatment method in the vertically restricted sites.

충북지역 일부 고등학생의 수면시간과 스트레스 및 청소년 영양지수와의 관련성 (Association of Sleep Duration with Stress Status and Nutritional Quotient for Korean Adolescents (NQ-A) in High School Students in Chungbuk)

  • 배윤정;김인영;김옥선;최미경
    • 대한영양사협회학술지
    • /
    • 제27권2호
    • /
    • pp.113-123
    • /
    • 2021
  • This study aimed to examine the association between sleep duration, stress levels, and dietary behavior in adolescents. A survey was conducted on 453 students (227 male, 226 female) in high schools in the Chungbuk area. The participants were divided into groups based on daily sleep duration: group I (<5 hrs/d), group II (≥5 hrs/d and <6 hrs/d), group III (≥6 hrs/d and <7 hrs/d), and group IV (≥7 hrs/d). To measure the stress levels of participants, the survey had questions covering a variety of areas, including school life, family life, social relationships, and personal evaluation. To assess the dietary behaviors of participants, the survey included questions encompassing the Nutrition Quotient for Korean adolescents (NQ-A). Among female students, the sleep duration group IV had significantly lower total stress (P=0.022) and significantly lower stress in the personal evaluation area than the sleep duration group I (P=0.004). In the analysis of NQ-A, among female students, the sleep duration group IV showed significantly higher scores in balance (P=0.004), diversity (P=0.016), and total NQ-A score area (P=0.007) compared to other groups. There was a significant negative correlation between sleep duration and stress scores in total students (r=-0.24, P<0.001), while a significant positive correlation was seen between sleep duration and NQ-A scores in female students (r=0.16, P<0.05). To sum up, the longer the sleep duration, the lower the degree of stress, and the quality of meals which can be said to be a significant finding for high school students.

Status of Oxidative Stress and Antioxidant Levels in Smokers with Breast Cancer from Western Nepal

  • Nagamma, T.;Baxi, Jalaj;Singh, P.P.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권21호
    • /
    • pp.9467-9470
    • /
    • 2014
  • Background: Research indicates that oxidative stress induced by smoking plays a role in breast cancer. In view of these reports, we aimed to study th relationship between smoking and oxidative stress in breast cancer patients from the western region of Nepal. Materials and Methods: The study included a control group of 42 females (non-smoking healthy women) and a test group sudivided into Group I consisting of 46 female breast cancer patients who were smokers and Group II consisting of 42 non-smoking breast cancer patients. Detailed history of the patients was collected with the help of pre-test proforma. Plasma levels of malondialdehyde (MDA), total antioxidant activity (TAA) which represents total dietary antioxidants, vitamin C and ${\alpha}$- tocopherol were estimated by standard methods. Statistical analysis was done using SPSS version 16. Results: The plasma MDA, TAA, vitamin C and ${\alpha}$- tocopherol were $1{\pm}1.4nmol/ml$, $918{\pm}207{\mu}mol/L$, $1{\pm}0.24mg/dL$ and $0.94{\pm}0.31mg/dL$ in controls, $5{\pm}1.2nmol/ml$, $458{\pm}166{\mu}mol/L$, $0.64{\pm}0.32mg/dL$ and $0.5{\pm}0.3mg/dL$ in Group-I and $2.56{\pm}1.2nmol/ml$, $663{\pm}178{\mu}mol/L$, $0.78{\pm}0.2mg/dL$ and $0.77{\pm}0.2mg/dL$ in Group- II, respectively. Vitamin C, ${\alpha}$- tocopherol and TAA (p=0.001) were significantly reduced whereas MDA (p=0.001) was significantly raised in Group-I when compared to controls and Group-II. Conclusions: We observed a significant rise in oxidative stress and low levels of antioxidants in breast cancer patients with smoking habit. It is well known that free radicals facilitate the progression of breast cancer, possibly increasing the risk of progression to the next stage.

Al 7075 합금의 크리이프 파단수명에 관한 연구( I ) (A Study on the Creep Fracture Life of Al 7075 alloy( I ))

  • 강대민
    • 한국안전학회지
    • /
    • 제8권4호
    • /
    • pp.27-40
    • /
    • 1993
  • High temperature tensile tests, steady state creep tests, Internal stress tests and creep rupture tests using A17075 alloy( $T_{6}$ ) were performed over the temperature range of 9$0^{\circ}C$~50$0^{\circ}C$ (0.4 $T_{m}$ ~0.85 $T_{m}$ ) and stress range of 0.64~17.2(kgf/$\textrm{mm}^2$). The main results obtained in this paper were as follows. (1) The activation energies for yielding at the temperature of 0.4 $T_{m}$ ~0.75 $T_{m}$ were calculated to be 25.7~36.5kcal/mol, which were nearly equal to the activation energies for creep. (2) At around the temperature of 9$0^{\circ}C$~12$0^{\circ}C$ and under the stress level of 10~17.2(kgf/$\textrm{mm}^2$), and at around the temperature of 200~41$0^{\circ}C$ and under the stress level of 1.53~9.55(kgf/$\textrm{mm}^2$) and again at around the temperature of 470~50$0^{\circ}C$ and under the stress level of 0.62~l.02(kgf/$\textrm{mm}^2$), the applied stress dependence of steady state creep rate $n_{measu}$ measured were, respectively, 3.15, 6.62 and 1.1, which were in good agreement the calculated stress dependence $n_{ealeu}$ obtained by the difference of the applied stress dependence of the Internal stress and the ratio of the internal stress to the applied stress. (3) At the temperature range of 0.4~0.43 $T_{m}$ , and at the temperature range of 0.52~0.75 $T_{m}$ and again at the temperature range of 0.82~0.85 $T_{m}$ , the activation energies $Q_{measu}$ obtained by steady state creep rate, respective, 26. 16, 34.9, 36.2 and 36.1kcal/mol, which were in good agreement with those obtained with the activation energies under constant effective stress and the temperature dependence of Internal stress. (4) At the temperature range of the 0.52~0.73 $T_{m}$ and under the stress level of 1.53~9.55(kgf/$\textrm{mm}^2$), the stress dependence of rupture life(n’) measured was 6.3~6.6, which was in good agreement with the stress dependence of steady state creep rate(n). And at the same condition the activation energy for rupture( $Q_{f}$ ) measured was 32.0~36.9kca1/mol, which was also in good agreement with the activation energy obtained by steady state creep rate ( $Q_{c}$ ). (5) The rupture life( $t_{f}$ ) might be represented by athermal process attributed to the difference of the applied stress dependence of the internal stress and the ratio of the internal stress to the applied stress, and the thermal activated process attributied to the temperature dependence of the internal stress as $t_{f}$ = A'$\sigma$$_{a}$ {n(1-d $\sigma$$_{i}$ /d $\sigma$$_{a}$ )/(1-$\sigma$$_{i}$ / $\sigma$$_{a}$ )}.exp[{ $Q_{c}$ $^{*}$-( $n_{o}$ R $T^2$/ $E_{(T)}$) (d $E_{(T)}$/dT) - ( $n_{0}$ R $T^2$/ $\sigma$$_{a}$ - $\sigma$$_{i}$ ) (d $\sigma$$_{i}$ /dT)}/RT]. (6) The relationship betwween Larson-Miller rupture parameter and logarithmic stress was linearly decreased, so creep rupture life of Al 7075 alloy seemed to be predicted exactly with Larson-Miller parameter.meter.

  • PDF

연약지반 보강을 위한 저유동성 몰탈 개량체의 응력분담비에 관한 연구 (The Study on the Stress Concentration Ratio of Low Slump Mortar Grouting Mixtures for Improving the Soft Ground)

  • 박언상;김병일;박승도
    • 한국지반환경공학회 논문집
    • /
    • 제21권9호
    • /
    • pp.15-24
    • /
    • 2020
  • 본 연구에서는 저유동성 몰탈 주입공법의 개량체에 관한 응력분담비를 복합지반법, 지반아칭이론, 소성각법 및 2차원과 3차원 수치해석, 3차원 모형실험을 통해 평가하였다. 복합지반법으로 계산된 응력분담비는 89.3, 3차원 지반아칭이론을 적용할 경우 3.75~59.0, 3차원 소성각법의 경우 82.8로 이론별 응력분담비의 차이가 나타났다. 2차원 수치해석 결과 응력분담비는 63.0~77.0으로 개량율이 증가할수록 증가하는 것으로 나타났고, 3차원 수치해석 결과 50.0~56.0으로 2차원 해석 결과 대비 작게 예측되었다. 대형 삼축압축셀을 이용한 특수 모형 실험의 경우 하중단계별 응력분담비는 53.0~60.0으로 나타났고, 실험으로 평가한 응력분담비는 2차원과 3차원 수치해석적 예측치 내에서 측정되었다. 본 연구에서는 저유동성 몰탈 주입 공법의 개량체에 대하여 해석 및 실험값을 바탕으로 개량율에 따른 응력분담비에 대한 예측식을 제안하였다.

DMT를 이용한 사질토 정지토압계수 평가방법 (A Method Evaluating K0 of Granular Soil using DMT)

  • 최성근;이문주;배경두;이우진
    • 대한토목학회논문집
    • /
    • 제30권4C호
    • /
    • pp.193-200
    • /
    • 2010
  • 본 연구에서는 사질토의 응력이력 효과를 평가하기 위해 정지토압계수($K_0$)를 추정하는 방법을 제안하였다. 제안된 방법은 사질토의 상태정수(${\psi}$)를 매개로 하여 $K_D/K_{0-\psi}$ 관계와 $E_D/{\sigma_m}^'-{\psi}$ 관계를 조합한 $K_D/K_0=\chi(E_D/{\sigma_m}^')^{\delta}$ 의 형태로 표현된다. 챔버에서 수행된 딜라토미터시험 결과에 의하면 본 연구에서 제안된 관계식은 응력이력에 영향을 받지 않는 것을 알 수 있었다. 제안된 방법은 사질토의 정지토압계수 추정 시 딜라토미터 시험결과 만을 이용하는 간편한 방법이며, 콘관입시험과 딜라토미터 시험 결과를 동시에 이용하는 기존의 방법에 비해 간단하고 신뢰성이 높은 장점이 있다.

유한요소 해석을 이용한 현장 콘크리트 부착강도 측정조건 (Measurement Conditions of Concrete Pull-off Test in Field from Finite Element Analysis)

  • 김성환;정원경;권혁;김현오;이봉학
    • 산업기술연구
    • /
    • 제22권A호
    • /
    • pp.185-192
    • /
    • 2002
  • The performance of old and the new concrete construction depends upon bond strength between old and the new concrete. Current adhesive and strength measurement method ignores the effect of stress concentration from shape of specimens. Therefore, this research calculates stress concentration coefficient as the ratio of drilling depth to drilling diameter($h_s/D$), the ratio of overlay thickness to drilling diameter($h_0/D$), the ratio of steel disk thickness to drilling diameter(t/D), the ratio of overlay elastic modulus to substrate modulus($E_1/E_0$), the distance from core to corner border(L_$_{corner}$) and the distance between cores(L_$_{coic}$) vary. The finite element method is adapted to analysis The results from 'the F.E.M analysis are as follows. The stress concentration effects can be minimized when the ratio of drilling depth to drilling diameter($h_s/D$) is 0.20~0.25, the elastic modulus ratio($E_1/E_0$) is 06~1.0, and the ratio of steel disk thickness to drilling diameter(t/D) is 3.0. The overlay thickness, the distance from specimens to corner border(L_$_{corner}$), the distance between cores(L_$_{coic}$) almost do not affect to the stress concentration.

  • PDF

대각선 병설터널 굴착에 따른 응력과 변위특성 (The Characteristics of Stress and Displacement due to the Diagonal Parallel Tunnel Excavation)

  • 김영수;박송자
    • 한국지반환경공학회 논문집
    • /
    • 제12권11호
    • /
    • pp.39-49
    • /
    • 2011
  • 본 연구는 대각선 병설터널의 건설로 인한 응력과 변위 특성을 연구하였다. 이 연구에서 그 특성들이 터널의 직경(D)는 13m 그리고 지반은 풍화암으로 가정하여 해석하였다. 해석에서 pillar 폭은 2.0D, 2.5D, 3.0D, 토피고는 3D, 4D, 5D, 그리고 대각선 병설터널의 설치각도 $15^{\circ}$, $30^{\circ}$, $45^{\circ}$로 변화시켰다. 그리고 해석에 사용한 프로그램은 지반 공학적 문제해석에 널리 사용되고 있는 FLAC을 사용하여 발생하는 숏크리트 및 록볼트 응력과 주변지반 변위를 대각선 병설터널의 pillar 폭, 토피고, 그리고 설치각도에 따라 구하고 분석하였다. 그 결과 풍화암 지반에서는 pillar 폭 2.0D이상, 토피고 5.0D이상, 그리고 대각선 병설터널의 설치각도가 적을수록 주변 지반에 영향을 덜 미치고 터널의 안정에 유리한 것으로 나타났다.

대형모형실험을 통한 수평 절리암반에서의 병설터널 이격거리 (Pillar Width of Twin Tunnels in Horizontal Jointed Rock Using Large Scale Model Tests)

  • 이용준;이상덕
    • 터널과지하공간
    • /
    • 제20권5호
    • /
    • pp.352-359
    • /
    • 2010
  • 병설터널에서 근접 굴착으로 인한 영향은 터널간 이격거리에 따라 달라진다. 본 논문에서는 수평절리암반에 형성된 병설터널의 이격거리에 따른 영향을 파악하기 위하여 콘크리트 블록으로 균일 수평 절리 모형 지반을 조성하고 이격거리를 변화시키면서 모형터널을 설치한 후에 대형 모형실험을 수행하였다. 병설터널의 이격거리(필라폭)는 터널 폭 D를 기준으로 0.29D, 0.59D, 0.88D, 1.18D로 변화시켰다. 실험중에 필라 응력, 터널변위, 지반 변위를 계측하였다. 측압계수는 1.0을 유지하였다. 실험결과, 터널 및 주변지반의 변위와 필라 응력은 필라 폭이 감소함에 따라 증가하였다. 각 계측항목에서 최대 변화폭이 발생하는 단계는 후행터널의 상반굴착 직후로 나타났다. 병설터널 굴착 시 가장 큰 영향을 받는 위치는 필라부와 맞닿아 있는 선행터널의 어깨부로 확인되었다. 이러한 결과는 병설터널의 안정성은 시공 시 천단변위보다 내공변위 관리를 통해 평가되어야 한다는 것을 보여준다. 또한, 병설터널의 영향권이 양호한 지반조건에 대한 경험이론의 근접시공 영향권(0.8D~2.0D)보다 근접한 0.59D~0.88D 범위에서 형성되었으며 이러한 영향범위 감소는 병설터널의 안정성에 수평절리의 영향이 있는 것으로 판단된다.