• Title/Summary/Keyword: Strengthening Plate

Search Result 256, Processing Time 0.023 seconds

Effects of a 12-week Combined Exercise Program on Gait Parameters in Elderly Women with Osteoarthritis

  • Lee, Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.4
    • /
    • pp.227-236
    • /
    • 2018
  • Objective: The purpose of this study was to investigate the effects of a 12-week combined exercise program on gait parameters in elderly women with osteoarthritis. Method: The subjects of this study were 11 elderly women (age: $67.09{\pm}2.47$, height: $157.35{\pm}4.30cm$, weight: $62.49{\pm}6.36kg$) with knee osteoarthritis. The combined exercise program of this study was divided into aerobic exercise and lower extremity strengthening exercises. The exercises were performed for 60 minutes per session, three times a week, for a total of 12 weeks. The maximum joint moments of the hip, knee, and ankle joints with walking were obtained with 8-3D cameras (MX-T20, Vicon, USA) and 2-force plate (AMTI OR6-7-400, AMTI, USA). SPSS Windows version 23.0 was used for statistical analysis. A paired t-test was used for pre-post comparison. An alpha level of .05 was utilized in all tests. Results: The maximum extension moment was significantly higher in the hip joint after P1 on the X axis. The maximum joint moment of P3 in extension was statistically significantly lower after intervention. On the Z axis, the maximum joint moment was significantly lower after the exercise intervention at P3. There was a statistically significant increase in the extension moment of the left and right knee joints in the X axis after exercise intervention. In the right ankle joint, P1 (plantar flexion moment) showed a statistically significant high moment after exercise intervention. Conclusion: These results suggest that combined exercise, including lower limb and aerobic exercise, may have a positive effect on mobility and walking moments in patients with osteoarthritis of the knee.

Status of Facilities, Equipment, and Environmental Hygiene Management of School Foodservices in Daiyue-district, Taian-city, China (중국 태안시 다이웨구 학교급식소의 시설·기구·환경 위생관리 실태)

  • Cheng, Xiao Xia;Moon, Hye-Kyung
    • Journal of the FoodService Safety
    • /
    • v.2 no.2
    • /
    • pp.59-66
    • /
    • 2021
  • The results of the inspection based on the sanitation checklist and the measurement of refrigerator/freezer temperature, illuminance, and ATP were conducted at 12 school foodservices in Daiyue-district, Taian-city, Shandong Province, China, at the same time, and the results were as follows. Five items of 'Use sterilized cutting boards', 'Use sterilized knives', 'Use worktable after sterilization', 'Use sink after sterilization', 'Sterilize the interior/exterior of the refrigerator regularly' in the checklist inspection were found not to be performed (0%). Two items of 'Disinfect hands after washing', 'Equipped with hand sterilizer' and 'Sterilize the kitchen areas regularly' were investigated as being performed only in one foodservice (8%). The average illuminance of the receiving stand were 373.08±106.35 Lux, 8% when the standard (540 Lux or higher) was complied with, the average refrigerator temperature were 7.06±0.82℃, 38.9% when the standard (-2 to 5℃) was observed 8% of cases complying with the standard (below -18℃) at -8.56±0.76℃ were investigated. As a result of ATP measurement, the surfaces of knife edge, cutting board, refrigerator door handle, worktable, and sink, which are not sterilized at all, were not suitable (accept ratio 0%), sterilized food plate (accept ratio 54.2%) and utensil for preserved food (accept ratio 75%) had a relatively high accept ratio. China's hygiene regulations should be revised in the direction of strengthening disinfection practices for facilities, equipment, and the environment, and hygiene measures such as education on disinfection and preparation of economical disinfection methods should be established.

Bond behavior between concrete and prefabricated Ultra High-Performance Fiber-Reinforced Concrete (UHPFRC) plates

  • Mansour, Walid;Sakr, Mohammed A.;Seleemah, Ayman A.;Tayeh, Bassam A.;Khalifa, Tarek M.
    • Structural Engineering and Mechanics
    • /
    • v.81 no.3
    • /
    • pp.305-316
    • /
    • 2022
  • Externally bonded ultrahigh performance fiber-reinforced concrete (UHPFRC) is commonly used as a strengthening material for reinforced concrete (RC) structures. This study reports the results of an experimental program investigating the bonding behavior between concrete and prefabricated UHPFRC plates. The overall experimental program is consisting of five RC specimens, which are strengthened using the different lengths and widths of prefabricated UHPFRC plates. These specimens were analyzed using the pull-pull double-shear test. The performance of each strengthened specimen is presented, discussed and compared in terms of failure mode, maximum load, load-slip relationship, fracture energy and strain distribution. Specimen C-25-160-300 which bonded along the whole width of 160 mm recorded the highest maximum load (109.2 kN) among all the analysed specimens. Moreover, a 3D numerical finite element model (FEM) is proposed to simulate the bond behavior between concrete and UHPFRC plates. Moreover, this study reviews the analytical models that can predict the relationship between the maximum bond stress and slip for strengthened concrete elements. The proposed FEM is verified against the experimental program and then used to test 36 RC specimens strengthened with prefabricated UHPFRC plates with different concrete grades and UHPFRC plate widths. The obtained results together with the review of analytical models helped in the formation of a design equation for estimating the bond stress between concrete and prefabricated UHPFRC plates.

Cyclic Seismic Testing of Cruciform Concrete-Filled U-Shape Steel Beam-to-H Column Composite Connections (콘크리트채움 U형합성보-H형강기둥 십자형 합성접합부의 내진성능)

  • Park, Chang-Hee;Lee, Cheol-Ho;Park, Hong-Gun;Hwang, Hyeon-Jong;Lee, Chang-Nam;Kim, Hyoung-Seop;Kim, Sung-Bae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.503-514
    • /
    • 2011
  • In this research, the seismic connection details for two concrete-filled U-shape steel beam-to-H columns were proposed and cyclically tested under a full-scale cruciform configuration. The key connecting components included the U-shape steel section (450 and 550 mm deep for specimens A and B, respectively), a concrete floor slab with a ribbed deck (165 mm deep for both specimens), welded couplers and rebars for negative moment transfer, and shear studs for full composite action and strengthening plates. Considering the unique constructional nature of the proposed connection, the critical limit states, such as the weld fracture, anchorage failure of the welded coupler, local buckling, concrete crushing, and rebar buckling, were carefully addressed in the specimen design. The test results showed that the connection details and design methods proposed in this study can well control the critical limit states mentioned above. Especially, the proposed connection according to the strengthening strategy successfully pushed the plastic hinge to the tip of the strengthened zone, as intended in the design, and was very effective in protecting the more vulnerable beam-to-column welded joint. The maximum story drift capacities of 6.0 and 6.8% radians were achieved in specimens A and B, respectively, thus far exceeding the minimumlimit of 4% radians required of special moment frames. Low-cycle fatigue fracture across the beam bottom flange at a 6% drift level was the final failure mode of specimen A. Specimen B failed through the fracture of the top splice plate of the bolted splice at a very high drift ratio of 8.0% radian.

Long-Term Behavior of CFRP Strips under Sustained Loads (지속하중을 받는 탄소섬유판의 장기 거동)

  • You, Young-Chan;Choi, Ki-Sun;Kim, Keung-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.2
    • /
    • pp.139-146
    • /
    • 2009
  • Experimental study was performed to evaluate the long-term behavior of CFRP (carbon fiber reinforced polymer) strips under sustained loads including prestressing force in strengthening RC members with post-tensioned CFRP strips. Two types of CFRP strip such as unidirectional CFRP strip and hybrid CFRP strip which is composed of carbon fiber and steel plate were considered. Also two types of loading scheme were included in this study. Direct sustained loading test had been carried out to estimate the creep deformation and relaxation of CFRP strips including slip deformation at both mechanical anchorages for over 700 days. Also, flexural sustained loading test had been conducted to estimate the initial prestress losses on clamping the CFRP strips at jacking anchorages for over 90 days. From the sustained loading tests, it was observed that stress losses of unidirectional CFRP strips due to the creep deformation and relaxation of material itself and slip deformation at mechanical anchorage were ignorable. On the other hand, significant stress losses caused by the yielding of steel embedded in CFRP strips were found in case of hybrid CFRP strips due to the initial jacking force over steel yielding stress. Also, initial prestress losses during setting of CFRP strips on mechanical anchorage were about 10% of intial jacking force, which must be considered in the design.

Effects of spinal stabilization training on Chronic Low Back Pain in Private Guard and Security (척추안정화 운동이 민간 경호.경비원들의 허리통증에 미치는 영향)

  • Kim, Seong-Ho;Lee, Wan-Hee
    • Korean Security Journal
    • /
    • no.20
    • /
    • pp.71-93
    • /
    • 2009
  • The purpose of this study was to evaluate the effects of using spinal stabilization exercise for the improvement of atrophy of the multifidus and psoas major, of pain and disability with chronic low back pain in private guard and security. For 42 patients diagnosed with CLBP, and divided into spinal stabilization exercise group(SSEG) and general spinal strengthening exercise group(GSSEG). Each exercise was conducted for 10 weeks. Pain and disability were measured before and after exercise using the Visual analogue scale(VAS) and the Oswestry disability index(ODI). Cross section area(CSA) of both the left and right multifidus and the psoas major at the upper end plate of L4 were measured before and after exercise using computed tomography(CT). After 10 weeks of exercise, the both group's pain and lumbar disability were significantly decreased(p<0.01). Also there was significant difference in both group(p<0.05). In addition, the CSA of the left and right multifidus and posas major were significantly increased as compared to the pre-exercise in both group(p<0.01). But SSEG's cross sectional areas of multifidus was more significantly increase than GSSEG(p<0.05). In summary, Spinal stabilization exercise is more effective in improving atrophy in private guard and security patients, in reducing patients' pain and disability. It is an effective treatment to aid rehabilitation in these cases.

  • PDF