• Title/Summary/Keyword: Strength evaluation

Search Result 4,864, Processing Time 0.031 seconds

Evaluation of Bond Strength Properties with Changing the Aspect Ratio and Temperature of Concrete (콘크리트의 형상비 및 온도변화에 따른 부착강도 특성평가)

  • Kim, Hyun Seok;Jung, Won Kyong;Oh, Han Jin;Park, Jun Young;Kim, Hyung Bae
    • International Journal of Highway Engineering
    • /
    • v.20 no.3
    • /
    • pp.19-26
    • /
    • 2018
  • PURPOSES : The main purpose of this study is suggest of field bond strength evaluation method for more objective evaluation method through Evaluation of Bond Strength Properties with changing aspect ratio and temperature. METHODS : The evaluation is laboratory bond strength test. Using the core machine, the pull-off test method ; the bond strength test of interface layer the universal testing machine. RESULTS : As a result of the laboratory bond strength evaluation, it was verified that the bond strength by aspect ratio decreases linearly with increasing aspect ratio and the bond strength properties by temperature change existed at high and low temperature condition relative to odinary temperature condition. CONCLUSIONS : According to the results of laboratory bond strength evaluation, the field bond strength evaluation results suggest applying the proposed correction factor (0.8, 1.0, 1.4, 1.9) according to aspect ratio(0.5, 0.1, 1.5, 2.0), For more objective evaluation of the bond strength, it is analyzed that the evaluation value is within $6{\sim}32^{\circ}C$ and the result can be obtained within 5% of the coefficient of variation.

Strength Evaluation of a Doubler Plate of Ship Structure subjected to the In-plane Combined Load and Lateral Pressure Load (면내 조합하중과 횡압을 받는 선박 이중판의 강도 평가)

  • Ham, Juh-Hyeok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.6
    • /
    • pp.37-48
    • /
    • 2003
  • A study for the structural strength evaluation of doubler plates subjected to the in-plane combined load and lateral pressure load has been performed through a systematic evaluation process. In order to properly estimate the static strength of doubler plate, elasto-plastic large deflection analysis is introduced including the contact effect between main plate and doubler. The characteristics of stiffness and strength variation are discussed based on the analysis results. Also, in order to compare the doubler structure with the original strength of main plate without doubler, a simple formula for the evaluation of the equivalent flat plate thickness is derived based on the additional series analysis of fiat plate structure. Using this derived equation, the thickness change of a equivalent flat plate is analyzed according to the variation of various design parameters of doubler plate and some design guides are suggested In order to maintain the original strength of main plate without doubler reinforcement. Finally, correlation between derived equivalent plate thickness formula and the developed buckling strength formulas for intact plates by author et al. is discovered and these relations are formulated for the future development of simple strength evaluation formula of doubler plate structure.

The Effects of Ego Strength, Stress Coping Styles and Fear of Negative Evaluation on Children's Peer Relationships (자아강도, 스트레스 대처방식 및 부정적 평가에 대한 두려움이 아동의 교우관계에 미치는 영향)

  • Kim, Se Young;Choi, Naya
    • Korean Journal of Child Studies
    • /
    • v.34 no.4
    • /
    • pp.37-52
    • /
    • 2013
  • This study was performed to model the effects of ego strength, stress coping styles, fear of negative evaluation, and the effects these concepts have upon children's peer relationships. Data were collected from 580 fifth and six graders in Seoul and Gyeonggi province. In summary, the results indicated the following. Firstly, there were significant correlations between ego strength, stress coping styles, fear of negative evaluation, and peer relationships. Secondly, the ego strength of children was found to have direct influences upon their stress coping styles, fear of negative evaluation and peer relationships. Thirdly, out of stress coping styles of children affected by ego strength, only the negative coping style was found to significantly influence the fear of negative evaluation and peer relationships. Fourth, the fear of negative evaluation on the part of children was affected by ego strength and negative stress coping styles, and in particular, negative stress coping styles influenced peer relationships through the anxiety induced from interpersonal relationships.

Strength Demand Calculation for Retrofitting Unreinforced Masonry Buildings Based on the Displacement Coefficient Method and the Preliminary Seismic Evaluation Procedure (변위계수법 및 약산식 내진성능평가에 기초한 비보강 조적조 건물의 내진보강 요구강도 산정)

  • Seol, Yun Jeong;Park, Ji-Hun;Kwak, Byeong Hun;Kim, Dae Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.31-38
    • /
    • 2022
  • Based on the nonlinear static analysis and the approximate seismic evaluation method adopted in "Guidelines for seismic performance evaluation for existing buildings, two methods to calculate strength demand for retrofitting individual structural walls in unreinforced masonry buildings are proposed." The displacement coefficient method to determine displacement demand from nonlinear static analysis results is used for the inverse calculation of overall strength demand required to reduce the displacement demand to a target value meeting the performance objective of the unreinforced masonry building to retrofit. A preliminary seismic evaluation method to screen out vulnerable buildings, of which detailed evaluation is necessary, is utilized to calculate overall strength demand without structural analysis based on the difference between the seismic demand and capacity. A system modification factor is introduced to the preliminary seismic evaluation method to reduce the strength demand considering inelastic deformation. The overall strength demand is distributed to the structural walls to retrofit based on the wall stiffness, including the remaining walls or otherwise. Four detached residential houses are modeled and analyzed using the nonlinear static and preliminary evaluation procedures to examine the proposed method.

Evaluation of Static Strength on Ceramic /Metal Bonded Joints Considering Stress Singularity (응력특이성을 고려한 세라믹/금속 접합재의 정적강도평가)

  • 김기성
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.1
    • /
    • pp.59-68
    • /
    • 1997
  • Recently, the cases of using bonded dissimiliar materials which have each of the different components tend to increase for the purpose of developing new materials and using the special objects in the field of industry. Among the cases the strength evaluation of the joining materials of vehicle engine and the structural materials with ceramic/metal bonded joints becomes more important. But the residual stress occurs, because the joining of ceramics and metals is performed in extremely high temperature. It becomes a dominant cause to reduce the strength of the ceramic/metal bonded joints. In this paper, strength evaluation method of ceramic/metal bonded joints considering stress singularity was investigated by boundary element method and 4-point bending test. An advanced method of quantitative strength evaluation for ceramin/metal bonded joints is to be suggested.

  • PDF

A Study on the Reinforced Method of Doubler Plate in Ship Hull Structure (선박 이중판의 보강법 연구)

  • HAM JUH-HYEOK
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.5 s.54
    • /
    • pp.39-47
    • /
    • 2003
  • A study of the structural strength evaluation on the doubler plate, considering various load cases that were subjected to in-plane and out of plane combined load, has been performed through the systematic evaluation process. In order to estimate the proper static strength of doubler plate for various load cases, elasto-plastic large deflection analysis is introduced, including the contact effect between main plate and doubler. The characteristics of stiffness and strength variation are discussed, based on the results. In order to compare the doubler structure with the original strength of main plate, without doubler, simple formulas for the evaluation of the equivalent flat plate thickness are derived for each load case, respectively, based on the additional series of analysis of flat plate structure. Using these derived equations, the thickness change of an equivalent flat plate is analyzed according to the variation of various design parameters of doubler platesome design guides are suggested in order to maintain the original strength of main plate without doubler reinforcement. Finally, correlation between derived equivalent flat plate formula and the developed buckling strength formulas are discovered, and these relations are formulated for the future development of simple strength evaluation formula of general doubler plate structure.

The Evaluation of Compressive Strength in Cement Mortar using Electromagnetic Properties (전자기 특성을 이용한 시멘트 모르타르의 압축강도 평가)

  • Kim, Dong-Baek;Kwon, Seung-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.3
    • /
    • pp.51-57
    • /
    • 2008
  • NDT(Non-Destructive Testing Evaluation) using electromagnetic(EM) properties can be used for evaluation of physical performance in cement-based materials. In this study, a technique for strength evaluation in cement mortar is proposed through the measured EM properties(conductivity and dielectric constant). For this research, cement mortar specimens with 5 W/C ratios are made for evaluation of compressive strength and they are also utilized for tests of EM properties in the range of $0.2{\sim}20GHz$ frequency considering exposure condition and curing period. The averaged conductivity and dielectric constant in $5{\sim}20GHz$ frequency are reduced to $83{\sim}93%$ and $81{\sim}87%$, respectively with increasing water to cement ratios. Through the linear regression analysis, relationships between EM properties and results from the compressive strength are obtained, which shows higher correlated factor($0.93{\sim}0.94$) in the specimens exposed to room condition. The gradients in dielectric constant for strength results is measured to be higher than those in conductivity by $3.9{\sim}5.1$ times. The results from dielectric constant in room condition shows the most efficient relation for evaluation of strength.

Structural Safety Evaluation for Static Strength of Thin Plate RC Member with High Strength Concrete (고강도 콘크리트를 적용한 얇은 RC 판부재의 정적 강도 안전성 평가)

  • Hwang, Hoon-Hee;Park, Sung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.69-75
    • /
    • 2017
  • Structural safety evaluation for static strength of thin plate RC member with high strength concrete is conducted in this study. Static strengths were predicted and compared with the experimental values. Predicted values were calculated by the evaluation formula based on the punching shear behavior and the yield line theory which can appear in the plate members. Static load tests were carried out for the specimens with high strength concrete and the test results were compared with the required performance in design. The comparison results show that the specimens with high strength concrete have sufficient structural safety for flexural and punching shear performance required in design. High strength concrete specimens exhibited excellent strength despite their small thickness. The range of concrete strengths applied in this study was about 60 MPa to 100 MPa.

A Study on Comparison and Evaluation of various Strength in Seoul Granite (서울화강암의 암석강도 측정치의 비교 평가 연구)

  • 윤지선;김두영;정흥모
    • Tunnel and Underground Space
    • /
    • v.5 no.2
    • /
    • pp.144-154
    • /
    • 1995
  • In this paper, we make a study on comparison and evaluation of the seoul granite properties, which are unit weight, uniaxial compressive strength, Brazilian tensile strength and, point load strength. The typical result are as follow- 1. From the measured value of point load strength anisotropy index, the seoul granite is considered to be homogeneous. 2. There is a linear relationship between uniaxial compressive strength and size corrected point load strength index. 3. Brazilian tensile strength and size corrected point load strength index are closely tied together.

  • PDF