• Title/Summary/Keyword: Strength Estimation

Search Result 1,377, Processing Time 0.029 seconds

Static Strength of Ring-stiffened Tubular T-joints (내부 환보강 T형 관이음부의 정적강도)

  • Cho, Hyun-Man;Ryu, Yeon-Sun
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.145-150
    • /
    • 2002
  • Tubular joints having a large diameter in the offshore structure are reinforced using internal ring stiffener in order to increase the load carrying capacity. In this study, the static strengths of internally ring-stiffened tubular T-joints subjected to compressive brace loading are assessed. Nonlinear finite element analyses are used to compute the behavior of unstiffened and ring-stiffened T-joints. From the numerical results, internal ring stiffener is found to efficient in improving the ultimate capacity, and reinforcement effect are calculated. The influence of geometric parameters for members and ring is evaluated. Based on the FE results, regression analysis is performed considering practical sizes of ring stiffener, finally strength estimation formulae for ring-stiffened T-joints are proposed.

  • PDF

Fatigue Strength Analysis of Propulsion Shafting System with Two Stroke Low Speed Diesel Engine by Torsional Vibration in Frequency Domain (주파수 영역에서 비틀림진동에 의한 저속 2행정 디젤엔진을 갖는 추진축계의 피로강도 해석)

  • Kim, S.H.;Lee, D.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.416-422
    • /
    • 2007
  • Prime movers in most large merchant ships adapt two stroke low speed diesel engine which has higher efficiency, mobility and durability. However, severe torsional vibration in these diesel engines may be induced by higher fluctuation of combustion pressures. Consequently, it may lead sometimes to propulsion shafting failure due to the accumulated fatigue stresses. Shaft fatigue strength analysis had been done traditionally in time domain but this method is complicated and difficult in analysing bi-modal vibration system such as the case of cylinder misfiring condition. In this paper authors introduce an assessment method of fatigue strength estimation for propulsion shafting system with two stroke low speed diesel engine in the frequency domain.

  • PDF

Lateral loading test for partially confined and unconfined masonry panels

  • Tu, Yi-Hsuan;Lo, Ting-Yi;Chuang, Tsung-Hua
    • Earthquakes and Structures
    • /
    • v.18 no.3
    • /
    • pp.379-390
    • /
    • 2020
  • Four full-scaled partially confined and unconfined masonry panels were tested with monotonic lateral loads. To study the effects of vertical force and boundary columns, two specimens with no boundary columns were subjected to different vertical forces, while two wing-wall specimens had the column placed eccentrically and in the middle, respectively. The specimens with no boundary columns exhibited ductile rocking behavior, where the lateral strength increased with increasing vertical compression. The wing-wall specimens with columns behaved as strut-and-tie systems. The column-panel interaction resulted in greater strength, lower deformation capacity and differences in failure modes. A comparison with analytical models showed that rocking strength can be accurately estimated using vertical force and the panel aspect ratio for panels with no boundary columns. The estimation for lateral strength on the basis of a panel section area indicated scattered error for wing-wall specimens.

Analysis of Measured Mean Compressive Strength of Ready-Mixed Concrete by Season in Gangwon Area (강원지역 레미콘의 계절별 평균압축강도의 통계특성 분석)

  • Yun, Kyong-Ku;Park, In-Jung;Hong, Young-Ho
    • Journal of Industrial Technology
    • /
    • v.33 no.A
    • /
    • pp.109-116
    • /
    • 2013
  • In this study the compressive strength data were collected from ready­mix concrete plants, and the analysis result showed that when using A­D test the concrete of 24MPa is suitable than that of 21MPa for normal distribution. The prediction formula for average compressive strength were proposed to $f_{cu}=f_{ck}+4(MPa)$. When comparing the proposed equations and existing relationship, the estimation variations of elastic modulus and creep modulus were not significant. The proposed equation confirmed that there was no effect to the influence function for modulus of elasticity and creep. Therefore, it was concluded that the proposed equation could replace the exiting interaction formula.

  • PDF

Analysis of data on mechanical properties and durability of recycled aggregate concrete to develope estimation program of recycled aggregate concrete strength (재생콘크리트 강도 예측 프로그램 개발을 위한 재생콘크리트의 역학적 특성과 내구성에 관한 자료 분석)

  • Choi Hee-Bok;Kang Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • v.y2004m10
    • /
    • pp.15-19
    • /
    • 2004
  • The production of waste concrete is increased continuously by urban renewal, reconstruction, remodeling, and so on. So the positive use of recycled aggregate concrete is needed. Research for recycled aggregate concrete that use recycled aggregate from the mid-80s to solve environmental problem of aggregate insufficiency and waste concrete is consisting vigorously. However, specifications and mix design about waste concrete's use are evading use of recycled aggregate concrete yet in spot being not taken a triangular position. Therefore. it analyze existing research data for recycled aggregate concrete collection to develop strength estimate program in this research. Recycled aggregate concrete's strength estimate program if specifications and mix design about recycled aggregate concrete are taken a triangular position to foundation recycled aggregate concrete's practical use to increase judge.

  • PDF

Temperature and Property Control of High Strength Steel in Hot Strip Mills (열간압연 고강도강의 온도 및 재질제어)

  • Park, Cheol-Jae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.6
    • /
    • pp.817-823
    • /
    • 2011
  • This paper proposes a cooling stop temperature control(CST) and a phase transformation control(PTR) which aim at obtaining the uniform temperature and quality along the longitudinal direction of the high strength steel on the run-out table(ROT) process. The problems of the temperature control are analyzed for the conventional steel and the new control concepts are derived from a time-temperature transformation(TTT) diagram. The proposed control technologies are verified from the simulation results under the temperature prediction model by the heat transfer governing equation, and the temperature estimation simulator. It is shown through the field test of the hot strip mills that the phase transformation ratio of the high strength steel is considerably improved by the proposed temperature controls.

A Stochastic Analysis in Fatigue Strength of Degraded Steam Turbine Blade Steel (열화된 증기 터빈블레이드의 피로강도에 대한 확률론적 해석)

  • Kim, Chul-Su;Jung, Hwa-Young;Kim, Jung-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.262-267
    • /
    • 2001
  • In this study, the Reliability of degraded steam turbine blade was evaluated using the limited fatigue data. The statistical estimation of limited fatigue data implies that some unknown uncertainties which may be involved in fatigue reliability analysis. Therefore, an appropriate distribution in the fatigue strength was determined by the characteristic distribution - linear correlation coefficient, fatigue physics, error parameter. 3-parameter Weibull distribution is the most appropriate distribution to assume for infinite region. The load applied on the blade is mainly tensile. The maximum Von-Mises stress is 219.4 MPa at the steady state service condition. The failure probability($F_p$) derived from the strength-stress interference model using Monte carlo simulation under variable service condition is 0.25% at the 99.99% confidence level.

  • PDF

Estimation of Punching Shear Strength for Ultra High Performance Concrete Thin Slab (강섬유 보강 초고성능 콘크리트 슬래브의 뚫림 전단 성능 평가)

  • Park, Ji-Hyun;Hong, Sung-gul
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.2
    • /
    • pp.95-103
    • /
    • 2015
  • UHPC(Ultra High Performance Concrete) is used widely with its remarkable performance, such as strength, ductility and durability. Since the fibers in the UHPC can control the tensile crack, the punching shear capacity of UHPC is higher than that of the conventional concrete. In this paper, seven slabs with different thickness and fiber volume ratio were tested. The ultimate punching shear strength was increased with the fiber volume ratio up to 1%. The shear capacity of specimens with the fiber content 1% and 1.5% do not have big differences. The thicker slab has higher punching shear strength and lower deformation capacity. The critical sections of punching shear failure were similar regardless of the fiber volume ratio, but it were larger in thicker slab.

Strength Evaluation of Slender Steel Reinforced Concrete Beam-Columns

  • Chung, Jinan;Choi, Seongmo;Kim, Dongkyu
    • Architectural research
    • /
    • v.3 no.1
    • /
    • pp.61-70
    • /
    • 2001
  • The paper is intended to propose design strength of slender steel reinforced beam-columns by using the modified superposed method. The design of composite members is carried out by a superposed strength method in AIJ (Architectural Institute of Japan) design method. The bearing capacities of the steel part and the concrete part have to be determined separately and then added to a combined capacity. Authors have proposed a new superposed method in a modified form for the slender composite beam-columns and reinforced column. The modified superposed method is adopted for the slender steel reinforced beam-columns. Validation of the modified superposed method is undertaken by comparison with analytical results calculated assuming a sine curve deflected shape of the beam-columns, and with the test results conducted in Japan.

  • PDF

Characteristics of Concrete Filled Circular Tubular Stub Columns based on Experiment and Data Analysis (실험 및 데이터 분석에 의한 CFCT 단주 특성)

  • Kang, Hyun-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.1
    • /
    • pp.161-168
    • /
    • 2001
  • The use of composite members to improve the compressive strength of steel structure is a common practice these days and its efficiency has already been proved by several researches and experiments. The result of concrete filled circular tubular(CFCT) stub column tests is introduced in this paper. The main parameter of this test is the ratio of diameter to thickness of circular hollow section. From the test results, the effect of concrete filled in steel tube on the ultimate strength, the deformation capacity and initial stiffness are discussed. The purpose of this paper is to investigate the effect of various parameters and evaluate the compressive strength of confined concrete. It would contribute to a better understanding of CFT structure, further laboratory experimentations are needed for better accurate estimation on its effect.

  • PDF