• 제목/요약/키워드: Stray currents

검색결과 34건 처리시간 0.016초

펌프장의 흡입수조내 흡입관의 유동특성에 관한 PIV 측정 (A PIV Measurement on Flow Characteristics of Intakes within a Sump in a Pump Station)

  • 이영호;김유택;김정환;최종웅
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.209-215
    • /
    • 2001
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and no stray currents, Hence, flow into the Pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. But various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall and back-wall due to different clearances from back-wall to vertical in take pipe. Moreover, the locations and vorticities of the various types of vortices that were found in the examinations are discussed.

  • PDF

PIV에 의한 흡입수조내 흡입관 주위의 유동특성에 관한 연구 (Study on Flow Characteristics around Intakes within a Sump by PIV)

  • 최종웅;김정환;남청도;김유택;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.563-569
    • /
    • 2001
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and no stray currents, Hence, flow into the pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. But various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall and back-wall due to different clearances from back-wall to vertical in take pipe. Moreover, the locations and vorticities of the various types of vortices that were found in the examinations are discussed.

  • PDF

다중 흡수정을 갖는 펌프장 모델의 유동균일성 해석 (Numerical Analysis on the Flow Uniformity in a Pump Sump Model with Multi Pump Intake)

  • 최종웅;최영도;임우섭;이영호
    • 한국유체기계학회 논문집
    • /
    • 제12권4호
    • /
    • pp.14-22
    • /
    • 2009
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite basin with no close walls or floors and with no stray currents. Therefore, flow into the pump intake is with no vortices or swirling. However, pump station designers relying on these curves to define the operating conditions for the pump selected sometimes meet the reductions of capacity and efficiency, as well as the increase of vibration and additional noise, which were caused by air-entered flow in the pump station. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump of pump station model. Multi-intake sump model with anti-submerged vortex device basin is designed and the characteristics of submerged vortex is investigated in the flow field by numerical simulation. In this study, a commercial CFD code is used to predict the vortex generation in the pump station accurately. The analysed results by CFD show that the vortex structure and effect of anti-submerged vortex device are different at each pump intake channel.

서지전압에 대한 50[A]용 누전차단기의 부동작 특성 (Dead Operation Characteristics of Earth Leakage Circuit Breaker for 50[A] Against Surge Voltages)

  • 이승칠;장석훈;이복희
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권5호
    • /
    • pp.44-52
    • /
    • 1997
  • 반도체와 IC를 포함한 전자회로는 서지 전압 및 전류에 대해 매우 취약하다. 따라서 전자회로와 교류전원선로에 서지보호장치가 널리 사용되고 있다. 이들 서지보호장치의 동작에 의해 누전 차단기가 오동작 할 수 있으며, 누전 차단기의 오동작에 의한 교류전원의 차단은 전자.정보화 시스템의 운전효율 및 신뢰성의 저하와 경제적인 손실 등과 같은 단점을 초래한다. 본 연구의 목적은 서지 전압에 대한 누전 차단기의 오동작 특성을 조사하는 것이다. 10〔kV〕의 1.2/50〔$\mu\textrm{s}$〕서지전압발생기를 제작하였으며, 한국공업규격 KS C 4613의 시험조건과 바리스터를 포함하는 모의 시험회로 조건에 대해 서지 전압을 인가하였을 때 누전 차단기의 오동작 특성을 측정하였다. 그 결과, 서지 전압과 표류정전용량이 증가함에 따라 누전 차단기의 영상전류의 피크값은 증가하였다. 본 연구에서 사용된 모든 누전 차단기는 KS C 4613에 규정된 뇌임펄스 부동작 시험조건에는 적합하였다. 그러나 바리스터를 삽입한 시험회로 조건에서는 단지 1종의 시료를 제외하고 모두 오동작하였다. 서지보호장치를 가지고 있는 교류전원선로에 설치된 누전차단기는 오동작할 가능성이 매우 높다.

  • PDF