• Title/Summary/Keyword: Strap type

Search Result 35, Processing Time 0.021 seconds

Ship Flexure Error Compensation of Transfer Alignment via Robust State Estimation (강인한 상태추정에 의한 전달정렬의 선체유연성오차 보상)

  • Lim, You-Chol;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.2
    • /
    • pp.178-184
    • /
    • 2002
  • This paper deals with the transfer alignment problem of SDINS(StrapDown Inertial Navigation System) subjected to roll and pitch motions of the ship. In order to reduce alignment errors induced by ship body flexure, a linearized error model for the velocity and attitude matching transfer alignment system is first derived by linearizing the nonlinear measurement equation with respect to the dominant y axis component and defining the flexure state of random constant type. And then a robust state estimation scheme is introduced to account for modeling uncertainty of the flexure. By interpreting the simulation results and comparing with the velocity and DCM(Direction Cosine Matrix) partial matching method, it is shown that the proposed method is effective enough to improve the azimuth alignment performance.

Performance of cold-formed steel wall frames under compression

  • Pan, Chi-Ling;Peng, Jui-Lin
    • Steel and Composite Structures
    • /
    • v.5 no.5
    • /
    • pp.407-420
    • /
    • 2005
  • This study presents the strength of braced and unbraced cold-formed steel wall frames consisting of several wall studs acting as columns, top and bottom tracks, and bracing members. The strength and the buckling mode of steel wall frames were found to be different due to the change of bracing type. In addition, the spacing of wall studs is a crucial factor to the strength of steel wall frames. The comparisons were made between the test results and the predictions computed based on AISI Code. The related specifications do not clearly provides the effective length factors for the member of cold-formed steel frame under compression. This paper proposes effective length factors for the steel wall frames based on the test results. A theoretical model is also derived to obtain the modulus of elastic support provided by the bracing at mid-height of steel wall frames in this research.

Subtalar Arthroscopy (거골하 관절의 관절경술)

  • Ahn, Jae-Hoon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.235-241
    • /
    • 2009
  • The development of good quality small-diametered arthroscopes and refined arthroscopic techniques has contributed to the improvement of the subtalar arthroscopy. The therapeutic indications are synovectomy, removal of loose bodies, debridement and drilling of osteochondritis dissecans, excision of subtalar impingement lesions and osteophytes, lysis of adhesions for post-traumatic arthrofibrosis, removal of a symptomatic os trigonum, calcaneal fracture assessment and reduction, and arthroscopic arthrodesis of the subtalar joint. The subtalar arthroscopy can be done in supine position using thigh holder or in lateral decubitus position. The arthroscope generally used is a 2.7-mm 30 degrees short arthroscope. Noninvasive distraction with a strap around the hindfoot can be helpful. Usually anterolateral, middle and posterolateral portals are utilized for inspection and instrumentation within the joint. Twoportal posterior subtalar arthroscopy in prone position can be performed as well with 4.0-mm 30 degrees arthroscope, depending on the type and location of the subtalar pathology. The subtalar arthroscopy is a technically demanding procedure, which requires proper instrumentation and careful operative technique. Possible complications are nerve damage and persistent wound drainage.

  • PDF

The Variations in Gait Parameters and the Muscle Activities on the Non-Affected Side of the Shoulder Girdle According to Arm Sling Type in Patients with Hemiplegia (팔걸이 형태에 따른 편마비 환자의 보행 변수 및 비마비측 견갑대의 근활성도 변화)

  • Lee, Og-Kyung;An, Duk-Hyun;Yoo, Won-Gyu;Oh, Jae-Seop;Yoon, Ji-Yeon
    • Physical Therapy Korea
    • /
    • v.17 no.3
    • /
    • pp.77-86
    • /
    • 2010
  • The purpose of this study was to investigate the variations in gait parameters in terms of the type of arm sling used in hemiplegic patients. Ten patients with hemiplegia and ten healthy adults participated in this study and walked at self-selected speeds on a GAITRite-instrumented carpet. The activities of the opposite shoulder girdle muscle including the latissimus dorsi, anterior deltoid, and posterior deltoid were simultaneously recorded using surface EMG during gait. They were randomly assigned a condition: without an arm sling, a single strap arm sling, a Harris hemi arm sling, a Rolyan humeral cuff arm sling, and a Bobath roll arm sling. The following gait variables were analyzed: the temporo-spatial parameters of velocity, step length, stride length, swing phase, stance phase, single support, step time and toe in/toe out. The statistical analysis was one-way ANOVA with repeated measures to compare the variation of each variable. In comparison of parameters in each trial in the hemiplegia group, the non-affected side stride length, single support, and toe in/toe out resulted in statistically significantly changes (p<.05). But without an arm sling group did not show any gait parameter differences with arm slings. This study found that several arm slings varied gait patterns in patients with hemiplegia and in healthy adults. In the EMG analysis, the Rolyan humeral cuff arm sling and the Bobath roll arm sling were higher muscle activity for the latissimus dorsi muscle than did the single strap ann sling. Further study should examine the problems that appeared in patients who worn arm slings by focusing on a larger number of subjects and by studying the variety of responses in more detail using an assessment tool that measures variation.

Selection of mAs with Using Table Strap in Computed Tomography Scan (전산화단층촬영 시 환자 고정 밴드를 이용한 선량의 선택)

  • Lee, Young-Hyen;An, Hyeong-Theck
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.63-69
    • /
    • 2011
  • Table strapis patient fixture for securing the patient movements and falls. if it designed to measure the abdominal circumference and used as an indicator of dose selection at CT scan. it will prevent the overexposure of dose without degradation of image quality and efficiently manage dose of each type of body to technician to deal with CT. First, in order to compare the dose used in CT image and qualitative characteristics. reference image is obtained by examining the abdominal phantom in same conditions with the hospital 120 kVp, 200 mAs, D-Dom (Dynamic Dose Of Modulation). SNR, PSNR, RMSE, MAE, CTDIvol of CT images are compared with reference image. for comparing with reference image, the image that Umbilicus level image of Abdomen CT is stored in the PACS were used. For comparison, the top 12 o'clock portion of the air drawn from the same ROI was measured. CTDIvol, mAs, etc. In order to analyze the characteristics of the image, by measuring the length of the umbilicus circumference, pattern of the dose was analyzed. by using the analyzed perimeter and dose information, To be identified visually, fixed band that scale marked were produced. Use them, If the length of circumference of less than 60 cm 100 mAs, Case of 61~80 cm 120 mAs, Case of 80~100 cm 150 mAs, more than 100 cm 200 mAs, dose selection based on the perimeter, the image was applied. by compare analyzed with the Reference Image, image quality was assessed. by compare with existing tests that equally 200 mAs applied, How much was confirmed that the dose reduction. 1. Depending on the Abdominal circumference, the average PSNR(dB) of the image that differently dose applied was 45.794. 2. Comparing with existing test. the dose of scan that adjusted the mAs depending on the circumference was decreased about 40%. SNR and PSNR of the image that obtained by adjusting the standard mAs based on dose modulation were not much different. Therefore, By choosing a low mAs. dose reduction can be obtained. and the dose selection method that measured Abdominal circumference using a fixed band can protect the overexposure and uniformly apply dose of each type of body to technician to deal with CT.

  • PDF

A Study on the Analysis and Verification of Evaluation system for the Usability Evaluation of Purpose-Based XR Devices (목적 기반 XR 디바이스의 사용성 평가를 위한 평가체계 분석 및 검증 연구)

  • Young Woo Cha;Gi Hyun Lee;Chang Kee Lee;Sang Bong Lee;Ohung Kwon;Chang Gyu Lee;Joo Yeoun Lee;JungMin Yun
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.20 no.spc1
    • /
    • pp.56-64
    • /
    • 2024
  • This study aims to compare and evaluate the usability of domestic and overseas XR devices. With the recent release of 'Apple Vision Pro', interest in the XR field is increasing rapidly. XR devices are being used in various fields such as defense, medical care, education, and entertainment, but the evaluation system for evaluating usability is still insufficient. Therefore, this study aims to derive improvements in domestic equipment through comparative evaluation of usability for two HMD-type devices and one glasses-type device that are released. In order to conduct the study, 20 participants in their 20s to 30s who were interested in XR devices and had no visual sensory organ-related disabilities were evaluated by wearing VR equipment. As a quantitative evaluation, electromyography through an EMG sensor and the device and body temperature of the device through a thermal imaging camera were measured. As a qualitative evaluation, the safety of wearing, ease of wearing, comfort of wearing, and satisfaction of wearing were evaluated. As a result of comparing the usability of the devices based on the results, it was confirmed that domestic HMD-type device needs improvement in the strap part.

Development of Wireless ECG Clothing for Dogs with Improved Signal Detection (신호 감지성이 향상된 반려견용 무선 심전도 측정 의복 개발)

  • Kim, Soyoung;Lee, Okkyung;Kwon, Eunsun;Lee, Yejin;Min, Seungnam;Lee, Heeran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.5
    • /
    • pp.760-771
    • /
    • 2022
  • This study sought to develop clothing for a companion animal that can provide stable ECG measurements. A pattern for the smart clothing of a companion dog was manufactured using the replica method to select a location and method that best suited the stable measurement of ECG and improved the clothing's fitness. The smart clothing was developed as the following three types: strap type, top type, and combined top and vest type with a detachable wireless ECG monitor. The detection abilities of these were observed using the PQRST rate taken after ECG measurements while the three companion dogs were tested while resting and moving. The results revealed that apart from using an electrode, applying a gel pad is the most effective way to achieve stable ECG measurements, and the central chest region is more reliable than the left armpit for providing steady readings. The combined top and vest type showed the highest average ECG PQRST detection number, meaning that the ECG signal measurement was steady. These results may contribute to the measurement of ECG in smartwear for U-Healthcare to measure other biometric data of a companion dog.

Design and development of fabric-type fitness band (직물형 피트니스 밴드 디자인 및 개발)

  • Jeong, Dawun;Lee, Sojung;Kwon, Chae-Ryung;Park, Ihwa;Heo, Seowon;Kim, Dong-Eun
    • The Research Journal of the Costume Culture
    • /
    • v.26 no.4
    • /
    • pp.632-648
    • /
    • 2018
  • This study aims to contribute to the development of sports wearables. It was conducted by a convergence team of professionals in the fashion industry, kinesiology and sports studies, and computer science and engineering. The purpose of the current study was to design and develop a fabric-type fitness band for a sensor to measure acceleration during jump rope exercises. Computer science and engineering professionals developed the Arduino board and sensor, kinesiology and sports studies provided the necessary exercise protocol, and the fashion industry professionals developed the band. First, a fitness band preference survey was completed by men and women between the ages of 20 and 50. Typical uses of the band included tracking exercise amount as measured by the number of steps taken and calories burned. Strap watch closure, a single color and achromatic color, and soft and smooth touch materials were preferred as band design. Second, two fabric-type fitness bands were designed and developed. Design 1 had a 3-dimensional pocket for the sensor, bright blue color, and stretch binding around the edges and for a loop. Design 2 had a flat pocket for the sensor, achromatic color, mesh binding around the edges and two metal loops. Both designs had Velcro as a closure. Third, wear testing of both bands with the sensor were conducted of 15 women in their 20s. They wore the bands during jump rope exercises. Both bands generally satisfied the participants. The Design 2 band was slightly more satisfying than the Design 1 band.

Shear Strength Evaluation in Masonry Assemblages by Reinforcing Materials in Joint (줄눈 보강을 통한 면내 방향의 조적조 사인장 전단강도 평가)

  • Woo, Jong-Hun;Shin, Kyung-Jae;Lee, Jun-Seop;Han, Seung-Yun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.9
    • /
    • pp.191-198
    • /
    • 2019
  • All over the Republic of Korea, there are many masonry buildings which have been built since 1970s. When the earthquake at Po-Hang occurred, this is the main cause of huge damage because the masonry buildings have not seismic capacity. When masonry buildings are failed, two type of the failure modes can be shown, which are in-plane mode and out-plane mode. In-plane mode can have seismic capacity in masonry so diagonal shear test is performed in this study. The purpose of this study was to find the best way to reinforce the materials through the diagonal shear test. Through the test, shear stress and shear modulus of elasticity will be calculated, referred to the ASTM E 519-02. The variables in this test are ${\phi}3$ wire, three types of wire meshes, polypropylene strap and different types of brick. Each variable is applied to the same condition of the $1.2m{\times}1.2m$ masonry walls which are made by ASTM E 519-02. Compared to each variable with shear stress and shear modulus of elasticity, the best way of reinforcing method to have seismic capacity will be proved in this study.

Rapid Nondestructive Prediction of Multiple Quality Attributes for Different Commercial Meat Cut Types Using Optical System

  • An, Jiangying;Li, Yanlei;Zhang, Chunzhi;Zhang, Dequan
    • Food Science of Animal Resources
    • /
    • v.42 no.4
    • /
    • pp.655-671
    • /
    • 2022
  • There are differences of spectral characteristics between different types of meat cut, which means the model established using only one type of meat cut for meat quality prediction is not suitable for other meat cut types. A novel portable visible and near-infrared (Vis/NIR) optical system was used to simultaneously predict multiple quality indicators for different commercial meat cut types (silverside, back strap, oyster, fillet, thick flank, and tenderloin) from Small-tailed Han sheep. The correlation coefficients of the calibration set (Rc) and prediction set (Rp) of the optimal prediction models were 0.82 and 0.81 for pH, 0.88 and 0.84 for L*, 0.83 and 0.78 for a*, 0.83 and 0.82 for b*, 0.94 and 0.86 for cooking loss, 0.90 and 0.88 for shear force, 0.84 and 0.83 for protein, 0.93 and 0.83 for fat, 0.92 and 0.87 for moisture contents, respectively. This study demonstrates that Vis/NIR spectroscopy is a promising tool to achieve the predictions of multiple quality parameters for different commercial meat cut types.